20003447 6/03 Rev . 6 Jef ferson ® V ent Free Gas Heater Models: JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 Homeowner ’ s Installation and Operation Manual INST ALLER: DO NOT DISCARD THIS MANUAL - LEA VE FOR HOMEOWNER D E S I G N C E R T I F I E D 410 Admiral Blvd.
2 2 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Installation and Operating Instructions ....................................................................................... 3 JUVS Dimensions ............................................
3 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified.
4 4 Vermont Castings Jefferson Vent Free Gas Heater 20003447 JUVS Dimensions 28 ¹⁄₂ " (724mm) 24" (610mm) 3" (76mm) 14 ¹⁄₂ " (368mm) C L 8" (203mm) V alve Inlet 3447 Fig.
5 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus- tible materials and the heater as specified below for the appropriate firebox shell being installed.
6 6 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Firebox weight / shipping 1 10 lbs. The installation of your Vermont Castings stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.
7 Vermont Castings Jefferson Vent Free Gas Heater 20003447 V ent Free Features The JUVS Gas Heater is an unvented gas appliance tested and listed to the ANSI standard Z21.1 1.2a.2001. The V ent Free Gas Heater is configured to use Natural Gas, (JUVSRN, JUVSMN ) or Propane (JUVSRP , JUVSMP).
8 8 Vermont Castings Jefferson Vent Free Gas Heater 20003447 2. Divide the volume of space by 50 cubic feet. The result is the maximum BTU/hour the space can support.
9 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Unpack the Stove Remove the stove assembly from the shipping carton and inspect it for loose or damaged parts. Do not install this appliance if any parts are loose or if there is any visual or suspected damage resulting from shipping or handling.
10 10 Vermont Castings Jefferson Vent Free Gas Heater 20003447 MO T OR SNAPST A T ON/OFF RHEOST A T WHT WHT BLK BLK BLK GRN BLK ST236 Fig. 1 1 Fan wiring diagram. ST347a Fig. 10 Attach rheostat to control panel. V alve may look different. Rheostat Retaining Nut Control Knob Pinch Grommet to Remove Snapstat Bracket Snapstat Module ST468 Fig.
11 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Decorative Grate ST223 Fig. 14 Install back, left and right logs. 1 2 3 Thermostat Wire / Gauge Maximum Run 18 40 feet 20 25 feet 22 16 feet Thermostat Connection (optional) (R Models only) 1.
12 12 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Install the Stove Front The Front Plate attaches to the stove by four steel tabs that engage with corresponding cast ribs on the sides and bottom of the stove body .
13 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Operation Y our First Fire Read these instructions carefully and familiarize yourself with the burner controls of this heater . The JUVSR uses a Honeywell control valve that allows thermostatic, on/off switch regulation and has a sepa- rate Piezo ignition button.
14 14 Vermont Castings Jefferson Vent Free Gas Heater 20003447 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
15 Vermont Castings Jefferson Vent Free Gas Heater 20003447 T roubleshooting Follow these procedures in the order presented. W ARNING TURN OFF HEA TER AND ALLOW TO COOL COMPLETEL Y BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated.
16 16 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-of f valve is not fully open.
17 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Maintenance W ARNING Dust and debris accumulation can result in poor performance. Inspect the valve compartment, burner parts and log set frequently and clean these parts monthly or as often as accumulation warrants.
18 18 Vermont Castings Jefferson Vent Free Gas Heater 20003447 1a 1b 1c 1d 1e PILOT O N O F F PILOT ADJ L O H I TPTH TH TP 2 3 6 9 8 7a,b 4 15a 10 13 14 16a,b 17 11 12 18 19a,b c,d 15b 20 H I O FF PIL.
19 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Jefferson V ent Free Gas Heater (JUVS) (continued) Models 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 31 10, 31 1 1, 31 12 Ref. Description JUVS 1. Gas Log Set - JUVS 20003482 1a. Log Rear JUVS 20003483 1b.
20 20 Vermont Castings Jefferson Vent Free Gas Heater 20003447 Optional Accessories Fan Kits FK28 Fan Assembly The FK28 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature.
21 Vermont Castings Jefferson Vent Free Gas Heater 20003447 BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your new.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www .vermontcastings.com Ve r mont Castings, Majestic Products © V ermont Castings, Majestic P.
Een belangrijk punt na aankoop van elk apparaat Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.