Gebruiksaanwijzing /service van het product 2467 van de fabrikant Vermont Castings
Ga naar pagina of 28
INST ALLER / CONSUMER SAFETY INFORMA TION 30002008 3/06 Rev . 6 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPER- TY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
2 Dutchwes t N atur al V ent Gas H ea ter 30002008 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 Dutchwes t N atur al V ent Gas H eater 30002008 The Dutchwest Natural V ent Room Heater , Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Al - titudes.
4 Dutchwes t N atur al V ent Gas H eater 30002008 C L V alve Inlet C L V alve Inlet 2008 Dutchwest NV dimensions 6/23/03 17" (419 mm) 23" (584 mm) 28 " (721 mm) 4 &q.
5 Dutchwes t N atur al V ent Gas H eater 30002008 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt.
6 Dutchwes t N atur al V ent Gas H eater 30002008 V enting Requirements and Options The Dutchwest must be properly connected to a listed 4” (102 mm) T ype B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney sys- tems is required.
7 Dutchwes t N atur al V ent Gas H eater 30002008 Passing Through a Combustible W all or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceil- ing. Check with the maker of the vent system for the correct listed devices that are available.
8 Dutchwes t N atur al V ent Gas H eater 30002008 ST194 attach fan to shroud 1 1/99 Outer Shroud Slot Inner Shroud Slot ST194 Fig. 1 1 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. ST720 attach snapstat 8/02 Left Air Duct Fan Inner Shroud ST720 Fig.
9 Dutchwes t N atur al V ent Gas H eater 30002008 ST671 attach snapstat Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however , access is available through the rear when installing fan before gas line connection.
10 Dutchwes t N atur al V ent Gas H eater 30002008 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Dutchwest may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 23.
1 1 Dutchwes t N atur al V ent Gas H eater 30002008 Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Corporation Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model.
12 Dutchwes t N atur al V ent Gas H eater 30002008 Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body .
13 Dutchwes t N atur al V ent Gas H eater 30002008 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 25. Follow the lighting instructions on Page 14 exactly .
14 Dutchwes t N atur al V ent Gas H eater 30002008 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
15 Dutchwes t N atur al V ent Gas H eater 30002008 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
16 Dutchwes t N atur al V ent Gas H eater 30002008 Conversion Precautions Conversion must be completed only by qualified per- sonnel. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance.
17 Dutchwes t N atur al V ent Gas H eater 30002008 CO105a gas conv ersion Pilot 1/28/00 djt Pilot Hood Pilot Bracket CO105a Fig. 31 Remove pilot hood. CO106a D V360/580 Gas Con v ersion Pilot2 1/28/00 djt Index T ab Snap Ring Allen Wrench CO106a Fig.
18 Dutchwes t N atur al V ent Gas H eater 30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .
19 Dutchwes t N atur al V ent Gas H eater 30002008 Maintenance Y our Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician.
20 Dutchwes t N atur al V ent Gas H eater 30002008 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
21 Dutchwes t N atur al V ent Gas H eater 30002008 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIV ALENT .
22 Dutchwes t N atur al V ent Gas H eater 30002008 Dutchwest Natural V ent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Assembly 20003458 1a. Rear Log 20003459 1b. Right Log 20003460 1c. Left Log 20003461 2. Small Lava Rock Package 57897 3.
23 Dutchwes t N atur al V ent Gas H eater 30002008 Dutchwest Natural V ent Gas Heater (continued) Models 2467, 2468 Ref. Description Part Number 8. End, Rt - DW Gas 30001927 9. End, Lt - DW Gas 30001926 10. Gasket, Glass Med. Knit - RDV40 1203702 1 1.
24 Dutchwes t N atur al V ent Gas H eater 30002008 Decorative Rings 4” brass or black rings are available to add a decorative touch to the exposed stove pipe.
25 Dutchwes t N atur al V ent Gas H eater 30002008.
26 Dutchwes t N atur al V ent Gas H eater 30002008.
27 Dutchwes t N atur al V ent Gas H eater 30002008 BASIC W ARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2467 51.4 2468 51.4 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .
Een belangrijk punt na aankoop van elk apparaat Vermont Castings 2467 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Castings 2467 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Castings 2467 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Castings 2467 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Castings 2467 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Castings 2467 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Castings 2467 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Castings 2467 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.