✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
2 Dear Customer , Thank you for having pur chased and given your pr efer ence to our pr oduct. The safety pr ecautions and r ecommendations r eported below are for your own safety and that of others. They will also pr ovide a means by which to make full use of the featur es offer ed by your appliance.
3 IMPORT ANT PRECAUTIONS AND RECOMMENDA TIONS ✓ After having unpacked the appliance, check to ensure that it is not damaged. If you have any doubts, do not use it and consult your supplier or a professionally qualified technician. ✓ Packing elements (i.
4 COOKING POINTS 1. Auxiliary burner (AUX) - 3.500 BTU/hr 2. Semirapid burner (SR) - 6.000 BTU/hr 3. T riple ring bur ner (TC) - 11.500 BTU/hr CONTROL P ANEL DESCRIPTION 4. Auxiliary burner (AUX) control knob (1) 5. Right semirapid burner (SR) control knob (2) 6.
5 CHOICE OF BURNER (fig. 2.3) The symbols printed on the panel beside the gas knobs indicate the correspondence between the knob and the burner . The most suitable burner is to be chosen according to the diameter and volume capac- ity of the container to be warmed.
6 Do not use steam jet cleaners because the humidity could infiltrate into the appliance making it dangerous. GENERAL RECOMANDA TION ✓ Before you begin cleaning you must ensur e that the hob is switched off. It is advisable to clean when the appliance is cold.
7 CORRECT REPLACEMENT OF THE BURNERS It is very important to check that the burner flame spreader “ F ” and the cap “ C ” have been correctly positioned (see figs. 3.1 and 3.2 ). Failure to do so can cause serious problems. In appliances with electric ignition, check that the electrode “ S ” (fig.
8 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier .
9 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition.
10 installation to the cabinet min 22” 7/16 (570 mm) 30” (762 mm) 18” (457 mm) min 4” (102 mm) from cut-out max 13” (330 mm) 30” (762 mm) min 20” (508 mm) from cut-out max 13” (330 m m) 18” (457 mm) min 22” 7/16 (570 mm) Fig. 4.
11 20 mm min. 40 mm max. B C A Fig. 4.3 Fig. 4.4 F ASTENING THE COOKTOP (fig. 4.3 - 4.4) ✓ Each cooker top is provided with an installation kit including brackets and screws for fastening the top to fixtur e panels from 2 to 4 cm thick.
Gas supply line Shutoff valve “open” position To cooktop Fig. 5.1 12 All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Pr opane gas.
13 PRESSURE REGULA TOR INST ALLA TION To cooktop UNLOCK LOCK LOCK To cooktop LOCK Arrow STEP 1 The elbow connection can be turned in the direction requir ed after the manifold female pipe fitting has been slackened by using a wrench.
14 To mains connection To cooktop Manifold test point pressure 1/8” NPT 1/2” G cylindrical (ISO 228-1) male Cooktop manifold Manifold female pipe fitting Elbow connection Connector Pressure re.
15 b) Any conversion requir ed must be performed by your dealer or a qualified licensed plumber or gas service company . Please pr ovide the service person with this manual before work is started on the cooktop. (Gas conversions ar e the r esponsibility of the dealer or end user .
16 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A SETTING THE PRESSURE REGULA TOR (fig. 5.5) 1. Unscrew the r egulator cover; 2. Unscrew the A component, r everse and screw it according to the LP/PROP ANE r egulation. CONVERSION TO LP/PROP ANE GAS Every cooktop is provided with a set of injectors for the various types of gas.
17 REGULA TING THE BURNER MINIMUM SETTING When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. The adjustment is performed with the burner lit, as follows: –T urn the knob to the minimum position.
18 If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the cooktop is prop- erly grounded. Do Not ground to a gas pipe.
19 Wiring diagram key A Ignition coil PA Ignition switches group M Te r m inal block CA Igniter Fig. 6.2 A NL PA M CA CA CA CA WIRING DIAGRAM .
Cod. 1103614-ß1 The manufacturer cannot be held r esponsible for possible inaccuracies due to printing or transcription errors in the present booklet.
Een belangrijk punt na aankoop van elk apparaat Verona VEGCT424F (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Verona VEGCT424F heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Verona VEGCT424F vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Verona VEGCT424F leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Verona VEGCT424F krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Verona VEGCT424F bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Verona VEGCT424F kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Verona VEGCT424F . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.