Gebruiksaanwijzing /service van het product KK825 van de fabrikant Viking
Ga naar pagina of 14
SECTION TSM 845 P AGE 1 Of 14 ISSUE f VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA TECHNICAL SER VICE MANUAL INTRODUCTION Introduction .
SECTION TSM 845 ISSUE F P AGE 2 OF 14 DO NOT OPERA TE PUMP IF: – The front cover is not installed correctly . – Any guards are missing or incorrectly installed.
SECTION TSM 845 ISSUE F P AGE 3 OF 14 Series 823, 825 and 827 pumps are designed for long, trouble-free service life under a wide variety of application conditions with a minimum of maintenance. The points listed below will help provide long service life.
SECTION TSM 845 ISSUE F P AGE 4 OF 14 CLEANING PUMP: Keep pump as clean as possible. This will facilitate inspection, adjustment and repair work. STORAGE: If pump and coupling are to be stored, drain pump and pour non-detergent SAE 30 weight oil into the pump port.
SECTION TSM 845 ISSUE F P AGE 5 OF 14 4. Remove head from pump. Do not allow idler to fall from idler pin. T ilt top of head back when removing to prevent this. Avoid damaging head gasket set, all gaskets are required to maintain end clearance. 5. Remove idler and bushing assembly .
SECTION TSM 845 ISSUE F P AGE 6 OF 14 ITEM NAME OF P ART ITEM NAME OF P ART ITEM NAME OF P ART 1 Capscrews 5 Ball Bearing (2 Req’d) 9 Bracket 2 External Snap Ring 6 Internal Snap Ring 10 Canister 3 Bearing Housing 7 Key 11 Inner Magnet Assembly 4 Bearing Spacer 8 Outer Mag Assembly 12 Hand Knobs FIGURE 6 MD-C SERIES COUPLING 1.
SECTION TSM 845 ISSUE F P AGE 7 OF 14 4. Insert a brass bar through a port between two rotor teeth and loosen the capscrew holding the inner magnet to the shaft (See Figure 1 1). Do not forget, this is a very strong magnet. If pump disassembly is required, remove the external retaining ring.
SECTION TSM 845 ISSUE F P AGE 8 OF 14 DISASSEMBL Y & ASSEMBL Y OF MD-C SERIES BEARING HOUSING DISASSEMBL Y The bearing housing features two sealed ball bearings along with an outer magnet assembly . If further disassembly of this unit is required, proceed as follows: 1.
SECTION TSM 845 ISSUE F P AGE 9 OF 14 Use a suitable lubricant compatible with the fluid being handled when reassembling the pump. Inspect all parts, especially drilled holes in casing for the suck back system to make sure they are not plugged. Replace any worn parts and polish any burrs; clean all parts; assemble pump.
SECTION TSM 845 ISSUE F P AGE 10 OF 14 INST ALLA TION OF BUSHINGS CARBON GRAPHITE: SILICON CARBIDE ASSEMBL Y COUPLING: SERIES MD-C80 COUPLING When installing carbon graphite bushings, extreme care must be taken to prevent breaking. Carbon graphite is a brittle material and easily cracked.
SECTION TSM 845 ISSUE F P AGE 11 OF 14 ADJUSTING HEAD GASKET END CLEARANCE PUMP ROT A TION Use either of the following procedures to properly adjust the end clearance when replacing gaskets: PROCEDURE A: With balance plate in position, slide rotor and shaft into casing.
SECTION TSM 845 ISSUE F P AGE 12 OF 14 V AL VE - AS, AK AND AL SIZES V AL VE - LIST OF P ARTS 1. V alve Cap 6. V alve Body 2. Adjusting Screw 7. V alve Spring 3. Lock Nut 8. Poppet 4. Spring Guide 9. Cap Gasket 5. Bonnet 10. Bonnet Gasket DANGER ! Before opening any Viking pump liquid chamber (pumping chamber , reservoir , etc.
SECTION TSM 845 ISSUE F P AGE 13 OF 14 Some of the following may help pinpoint the problem: Pump does not pump: ► Lost its prime from air lead or low level in tank. ► Suction lift too high. ► Rotating in wrong direction. ► Strainer clogged. ► Bypass valve open, pressure relief valve set too low or pressure relief valve poppet stuck open.
SECTION TSM 845 P AGE 14 OF 14 ISSUE F VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA © 3/2013 Viking Pump Inc. All rights reserved W ARRANTY Viking warrants all prod.
Een belangrijk punt na aankoop van elk apparaat Viking KK825 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Viking KK825 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Viking KK825 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Viking KK825 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Viking KK825 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Viking KK825 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Viking KK825 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Viking KK825 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.