INS T ALL A TION & OPER A TION MANU AL GAS 2/3 JACKETE D S TA TIO NAR Y AND TI L TING KETTLES MODELS K20GL ML - 136090 K40GL ML - 136091 K60GL ML - 136092 K20G L T ML - 136094 K40G L T ML - 136095.
G AS K ETTLES — 2 — IMPORT AN T FOR YOUR SAFETY THIS M AN U AL H AS BEEN PRE P AR E D FOR PERSONNEL Q UALIFIED T O INS T ALL GA S EQUIPMEN T , WH O SHOUL D PERFOR M TH E I NITI A L FIE L D ST AR T -U P AND A DJUSTMENTS OF THE EQUIPM ENT CO VERE D BY THIS M AN U AL .
G AS K ETTLES — 3 — CONTENT S GENERAL ................... .......... ............... .......... ............... .......... ............... ............... .......... ............... .... . 4 INS T ALL A TION ..................... .......... ......
G AS K ETTLES — 4 — INS T A LLA T ION , OPER A TION AND MAINTE NANCE OF KGL A ND KG L T SERIES GAS KETTLES SA VE THESE INSTRUCTIONS FOR FUTURE USE GENERAL V ulcan gas 2/3 jack eted kettles are produced wit h qualit y workmanship and mat erial. Proper installation, usage and maintenance will result in many y ears of satis factory performance.
G AS K ETTLES — 5 — INS T ALL A TIO N UN P A CKING This k ettle wa s inspec ted bef ore leaving the factor y . The transportation company assumes full responsibility for safe deliv er y upon acceptance of the shipment. Immediately aft er unpac king, check for possibl e shippi ng da mag e.
G AS K ETTLES — 6 — G AS CONNECTIONS Gas supply connections and any pipe joint compound must be res istant to the action of propane gases. Codes require that a gas shuto f f valve be installe d in the gas line ahead o f the ke ttle. Connect the gas s upply line to the gas val ve on t he kettle.
G AS K ETTLES — 7 — Gas Connection Data FLEXIBLE G AS CONNEC T ORS BTU/h r . FLO W CA P AC I T Y 1, 2 LEN GTH 3 L ENG TH 3 End Fittings - ( 1) Q ui ck Disconnect & (1) Threade d End Fittings -.
G AS K ETTLES — 8 — G AS AN D A L TITUDE CONVERSI ON The kettle can be f ield converted to propane gas or for operat ion at altitudes above 2 000f t elevation . A manomet e r tha t r ead s in 1/100 " W C an d port abl e comb usti o n analyze r ar e req uire d.
— 9 — G AS K ETTLES A lti tude: 1. Remove the right side controls compartment side panel. 2. Locate the gas combination valv e located in the bottom of the controls compartment. 3. T urn S2 screw (Fi g. 1) (using 5/64” Allen wrench), ½ turn cl ock w ise 4.
— 10 — G AS K ETTLES LOC A TION Position the ke ttle in it s final locat ion. Check tha t there are s uff ic ie nt clearanc es for operating and servicing the k et tl e, and f or proper clearance of t he cover when raised. Keep the ke ttle f ree and clear from all combustible substances.
— 11 — G AS K ETTLES T ilting Kett le "Q" "P" "E" "F" "M" ADD 2" FOR PLUG VALVE "L" "K" "B" "N" "A" 12.0 [305] 9.3 [235] 4.1 [104] ELEC SHOW N W ITH OPTIONAL DRA W - OFF VALVE ( 2" PLUG VALVE) "R" 17.
— 12 — G AS K ETTLES the kettle. OPERA TION The kettle and its parts are hot. Use care w hen operat ing, cleaning or serv icing CONTROLS AND INDIC A T ORS Contro l Functio n V acuum/Pr essure Gaug e Indicates t he vacuum (in inches) and pr essure (in PSI) inside the kettle jacket.
— 13 — G AS K ETTLES BEFORE OPER A TION 1. Check G aug e Pressu re – should read 20 - 30 In . Hg . below zero wh e n cold. ( Higher r eadin g indicates air in jacket. See V enting instructions.) 2. Check to make sure gas supply valve is turned on.
— 14 — G AS K ETTLES VENTING W hile the kettle is cold, check the vacuum/pressure gauge. The ga uge sho uld be in the v acuum zone measuring between 20 to 30 in. Hg (84 to 100kPa). If n ot, t her e is air in the j ack et and it m ust be removed by venting f or pr oper heating.
— 15 — G AS K ETTLES ST A INLESS ST EEL EQUIPMENT C AR E A N D CLE A NING (Supplied courtesy of NAF EM. For more i nformatio n, vi sit their w eb site at ww w .nafem.org) Contrary to popular belief, sta inless steels A R E suscepti ble to rusting.
— 16 — G AS K ETTLES 4. T reat your w at e r . Though this is not always pr actical, sof te ni ng hard water can do much to reduce deposits. T here are certain f ilters th at can be installed to remove distasteful and corrosive elements. T o insure proper water treatment, call a treatment specialist.
— 17 — G AS K ETTLES CLE A NING The kettle and its parts are hot. Use care w hen operat ing, cleaning or serv icing the kettle. Disconnect the electrical po w er to the machine and fo llo w lockout / t agout procedure, before cleaning or servicing.
— 18 — G AS K ETTLES PLUG V A L VE CL EANING INSTRUCTIO NS Daily A fter Use Remove draw -of f valve plug for cleaning (Fig. 3). 1. Unscrew the retaining ring and remove it and the bottom w ashe r . 2. Pull t he va lve plug s tr aig ht up to remove from valve bod y .
— 19 — G AS K ETTLES M AI N T E N AN C E The kettle and its parts are hot. Use care w hen operat ing, cleaning or serv icing the kettle. VENTING W hen c old, the pressure gauge vacuum measuring z one should be between 20 to 30 I n. Hg (84 t o 100kPa).
G AS K ETTLES F- 35461 ( June 2012) — 20 — PRINTED IN U.S. A. TROUBLE SHOOTI NG Prob lem Possible Causes / Sug gested Co rr ect i ve A cti on W ill Not T urn On, no pow er light Kett le is not plugged i n / Plug in power cord. Power switc h is o ff / T urn on power sw itch.
Een belangrijk punt na aankoop van elk apparaat Vulcan-Hart ML-136090 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vulcan-Hart ML-136090 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vulcan-Hart ML-136090 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vulcan-Hart ML-136090 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vulcan-Hart ML-136090 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vulcan-Hart ML-136090 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vulcan-Hart ML-136090 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vulcan-Hart ML-136090 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.