Page 1 of the Weil-McLain WJB2 user manual — A C
Pagina 1 · klik om te vergroten
Pagina 1

Water- en stoomketels . Series 2 88

®

Branders voor gas, lichte olie en & Gas/Lichte Olieverbranding

Weil-McLain WJB2 — Water- en stoomketels . Series 2 88 diagram (page 1)
Afb. 1 · Water- en stoomketels . Series 2 88
Weil-McLain WJB2 — Water- en stoomketels . Series 2 88 diagram (page 1)
Afb. 2 · Water- en stoomketels . Series 2 88

Modellen WJB1 & WJ B2 Gasbrander

Gas/lichte oliebrander

Weil-McLain WJB2 — Gas/lichte oliebrander diagram (page 1)
Afb. 3 · Gas/lichte oliebrander
Weil-McLain WJB2 — Gas/lichte oliebrander diagram (page 1)
Afb. 4 · Gas/lichte oliebrander
Weil-McLain WJB2 — Gas/lichte oliebrander diagram (page 1)
Afb. 5 · Gas/lichte oliebrander

E W

Weil-McLain WJB2 — E W diagram (page 1)
Afb. 6

A C

B

D

H

Weil-McLain WJB2 — A C diagram (page 1)
Afb. 7
Page 2 of the Weil-McLain WJB2 user manual — Opmerkingen
Pagina 2 · klik om te vergroten
Pagina 2

Webster

Boiler Model nummer 88 Series 2BranderinvoerPositieve druk in Firebox In. W.C.Standaard brander ModelaanduidingStandaardverbrandingsregelingStandaardbesturingssysteemBrander Motor 3450 RPM HP.Standaardspanning Nee. 2 Olie GPHGas MBHGasLichte olieGas/lichte olieGasLichte olieGas/lichte olieGasLichte olieGas/lichte olieGas H.P.Lichte olieGas/lichte olie 488R6.99960.68WJB1G-03WJB1O-03WJB1C-03RM7897AR7184ARM7897CAAA1/31/31/3Zie aantekeningen 4887.010100.70WJB1G-03WJB1O-03WJB1C-03RM7897AR7184ARM7897CAAA1/31/31/3Zie aantekeningen 5889.413570.60WJB1G-05WJB1O-05WJB1C-05RM7897AR7184ARM7897CLFSLFSLFS1/21/21/2Zie aantekeningen 68811.817010.58WJB1G-07WJB1O-07WJB1C-07RM7897AR7184ARM7897CLFSLFSLFS3/43/43/4Zie aantekeningen 78814.220460.65WJB1G-07WJB1O-07WJB1C-07RM7897AR7184ARM7897CLFSLFSLFS3/43/43/4Zie aantekeningen 88816.623820.66WJB2G-07WJB2O-10WJB2C-10RM7897ARM7897ARM7897CLFSLFSLFS3/411Zie aantekeningen 988R17.224820.54WJB2G-10WJB2O-10WJB2C-10RM7897ARM7897ARM7897CLFSLFSLFS111Zie aantekeningen 98818.827370.63WJB2G-10WJB2O-10WJB2C-10RM7897CRM7897ARM7897CLFSLFSLFS111Zie aantekeningen 1088R20.028870.68WJB2G-10WJB2O-15WJB2C-15RM7897CRM7897ARM7897CLFSLFSLFS11 1/21 1/2Zie aantekeningen 108821.530820.78WJB2G-10WJB2O-15WJB2C-15RM7897CRM7897ARM7897CLFSLFSLFS11 1/21 1/2Zie aantekeningen 118823.534280.78WJB2G-15WJB2O-15WJB2C-15RM7897CRM7897ARM7897CLFSLFSLFS1 1/21 1/21 1/2Zie aantekeningen 128826.037730.76WJB2G-15WJB2O-15WJB2C-15RM7897CRM7897ARM7897CLFSLFSLFS1 1/21 1/21 1/2Zie aantekeningen 138828.541190.77WJB2G-20WJB2O-15WJB2C-20RM7897CRM7897ARM7897CLFSLFSLFS222Zie aantekeningen 148831.044640.78WJB2G-20WJB2O-15WJB2C-30RM7897CRM7897ARM7897CLFSLFSLFS223Zie aantekeningen 158833.048090.73WJB2G-20WJB2O-30WJB2C-20RM7897CRM7897ARM7897CLFSLFSLFS232Zie aantekeningen 1688R34.549790.68WJB2G-30WJB2O-30WJB2C-30RM7897CRM7897ARM7897CLFSLFSLFS333Zie aantekeningen 168835.551550.74WJB2G-30WJB2O-30WJB2C-30RM7897CRM7897CRM7897CLFSLFSLFS333Zie aantekeningen 178838.054940.82WJB2G-30WJB2O-30WJB2C-30RM7897CRM7897CRM7897CLFSLFSLFS333Zie aantekeningen 188840.558450.80WJB2G-30WJB2O-30WJB3C-50RM7840LRM7897CRM7840LMODLFSMOD335Zie aantekeningen Standaardspanningsaanduidingen: 1/3 PK aanjager motor door 3⁄4 pk
Standaard Gas Componenten en Maten in Inches Modelnummer van de ketelHandbediende handklepLage gasdrukschakelaarGasdrukregelaarDiafragm-luchtklepGemotoriseerd bedrijfsgasventielGemotoriseerd bedrijfsgasventiel met bewijs van sluitingVeiligheidsgasventielHandmatig controleren van gasventielHoge gasdrukschakelaar 488R1-¼Facultatief1-¼1n.v.t.n.v.t.1-¼1Facultatief 4881-¼Facultatief1-¼1n.v.t.n.v.t.1-¼1Facultatief 5881-¼Facultatief1-¼n.v.t.1-¼n.v.t.1-¼1-¼Facultatief 6881-½Facultatief1 ½n.v.t.1-½n.v.t.1-½1-½Facultatief 7881-½Facultatief1 ½n.v.t.2n.v.t.22Facultatief 8881-½Facultatief1 ½n.v.t.2n.v.t.22Facultatief 988R1-½Facultatief1 ½n.v.t.2n.v.t.22Facultatief 9881-½Standaard1 ½n.v.t.2n.v.t.22Standaard 1088R1-½Standaard1 ½n.v.t.2n.v.t.22Standaard 10882Standaard2n.v.t.2n.v.t.22Standaard 11882Standaard2n.v.t.2n.v.t.22Standaard 12882-½Standaard2-½n.v.t.2n.v.t.2-½2Standaard 13882-½Standaard2-½n.v.t.2n.v.t.2-½2Standaard 14882-½Standaard2-½n.v.t.2n.v.t.2-½2Standaard 15882-½Standaard2-½n.v.t.2n.v.t.2-½2Standaard 1688R2-½Standaard2-½n.v.t.2n.v.t.2-½2Standaard 16882-½Standaard2-½n.v.t.22”2-½2Standaard 17882-½Standaard2-½n.v.t.2-½2-½2-½2-½Standaard 18882-½Standaard2-½n.v.t.2-½2-½2-½2-½Standaard

Opmerkingen

Brandercapaciteiten vermeld voor verhogingen tot 2000 voet. Voor hogere verhogingen, raadpleeg lokale Weil-McLain distributeur / agent of verkoopkantoor. 1.

Lichte olie ratings gebaseerd op No. 2 stookolie met een verwarmingswaarde van 140.000 Btu per gallon. 2. Gasemissies op basis van aardgas met een verwarmingswaarde van 1.000 Btu per kubieke voet en de specifieke zwaartekracht van 0,60. Gasbranders voor andere gassen zijn beschikbaar. Raadpleeg lokale 3. Weil-McLain distributeur/agent of verkoopkantoor. Boiler-brander unit te worden aangepast om +0.10 inch WC bereiken druk aan de rookgashals, wat resulteert in positieve druk in brandkast zoals vermeld. 4.

De minimale gasdruk is afhankelijk van de arbeidsomstandigheden. Gasbranders voor andere gasdruk zijn beschikbaar. Raadpleeg lokale Weil-McLain distributie 5. Tor/agent of verkoopkantoor. De getoonde gasopeningsdruk is bedoeld voor het starten van de installatie. De einddruk moet worden bepaald na controle van de werkelijke gasstroom en verbrandingswaarden. 6.

Page 3 of the Weil-McLain WJB2 user manual — Branderspecificatie en -gegevensblad
Pagina 3 · klik om te vergroten
Pagina 3

Branderspecificatie en -gegevensblad

Gasregelsystemen: 7. A (OO): Aan-uit operatie, lage brandstart, hoge vuurloop. Enkel geplaatste lucht, regelbare openingsgasklep. Aan-uit operatie, lage brand start, hoge vuurloop. Twee-positie lucht bestuurd door demper arm op gemotoriseerde gasklep. H (LHL): Laag-hoog-laaguitbranden. Twee-positie lucht bestuurd door demper arm op gemotoriseerde gasklep. M (MOD): Uit bedrijf genomen, met bewezen lage brandstart en volledige modulerende vuuromstandigheden met verbrandingsluchtregeling. Evenredige motor drijft brandstofmeetklep en verbrandingsluchtklep volgens de brandomstandigheden. Vaste demper voor-purge op 488-988R, open klep vóór-pure op 988-1888.

Modelnummer van de ketelDruk daling door middel van gastrein Inches W.C.Gas opening druk Inches W.C.Gasdruk vereist bij gascontrole Inlaat-inches W.C.Beginwaarde van de inkepingsafstand (Oil)Initiële damperinstellingsinches (Gas)Beginwaarde van de inkepingsafstand (Gas/lichtolie)OliesnoeienOliedruk PSIGBrandstofeenheid Burner-Moto Gedreven 3450 RPM Min.Max.Lage brandHoog vuurHoog vuurHoog vuur (Gas)Hoog vuur (olie)Aantal.GPH @ 100 PSIGMerkSproeihoekHoog vuurLage brandG type G 488R2.32.45.5141/411-1/41-5/16114.00Hago P45º30010022R220D 4 4882.32.55.7141/41-13/161-7/161-9/161-3/1614.00Hago P45º30510022R220D 4 5883.72.87.0281/213/161-7/81-7/81-3/1615.50Hago P45º29010022R220D 4 6882.73.26.2287/167/81-3/161-5/16117.00Hago P45º29010022R220D 4 7882.92.85.1281/21-3/81-13/161-7/81-1/224.25Hago P60º28010022R221D 7 8882.551.84.5285/81-1/211-3/41-1/2110.00Hago P45º28010022R221D 7 988R3.151.74.9285/81-3/41-1/81-7/81-3/4110.00Hago P45º30010022R221D 7 9883.81.85.8281-3/161-5/161-1/41-1/21-3/16111.00Hago P45º29010022R221D 7 1088R4.42.26.6285/81-1/81-3/81-1/41-1/826.00Hago P45º28010022R221D 7 10883.22.46.0283/41-5/161-7/161-7/161-5/1626.50Hago P45º28010022R221D 7 11884.02.06.4283/41-3/41-13/161-7/81-3/427.00Hago P45º28010022R221D 7 12883.02.46.02813/162-1/162-5/162-5/82-1/827.50Hago P45º30010022R221D 7 13883.82.06.3283/41-1/22-1/22-1/21 7/828.50Hago P60º29010022R322D 1 14884.62.67.72815/162-3/162-1/82-1/4229.00Hago P60º30010022R322D 1 15885.12.88.72812-1/83-3/83-1/42-1/4210.00Hago P60º28010022R322D 1 1688R4.62.99.2281 1/162-1/21-7/82-1/41-1/2210.00Hago P60º30010022R623D 1 16886.13.19.82812-5/82-1/42-1/22-1/8210.50Hago P60º29510022R623D 1 17885.254.59.1289/162-1/43-1/43-1/43211.00Hago P60º30010022R623D 1 18885.76.010.428131-3/41-7/81-7/838.0Delevan60º30065SG0550 1 Standaard oliepomp Locatie: 488R tot 1488 Gas / Olie

Lichte oliecontrolesystemen: 8.

LF (FALFS): Aan-uit werking, vaste lucht, verminderde brandstof lage brandstart, hoge vuurloop. Enkel geplaatste lucht, olie met twee posities.

Aan-uit operatie, lage brandaanval, hoge vuurloop. Twee-positie lucht, twee-positie olie.

H (LHL): Laag-hoog-laaguitbranden. Twee-positie lucht, twee-positie olie.

M (MOD): Aan-uit werking, met bewezen lage brandstart en volledige modulerende vuuromstandigheden. Proportioneel motor aangedreven brandstofmeetklep en luchtdemper voor de verbranding. Vaste demper voor-purge op 488-1088R, open klep vóór-pure op 1088-1888.

Gas/lichtoliecontrolesystemen: 9.

A/LF (OO/FALFS): Combineert de hierboven vermelde kenmerken van gas en lichte olie.

L/L (LHO/LHO): Combineert de hierboven vermelde kenmerken van gas en lichte olie.

H/H (LHL/LHl): Combineert de hierboven vermelde kenmerken van gas en lichte olie.

M/M (MOD/MOD): combineert de hierboven vermelde kenmerken van gas en lichte olie.

120/60/1 regelcircuit wordt gebruikt voor alle branders. 10.

De Besturingsschakeling transformator is als optie beschikbaar. 11.

Motor starter contact zal worden ingericht voor alle eenheden. 12.

Verbrandingsregelaars: 13.

a) R8184G-verbrandingscontrole gebruikt cadmiumcel voor vlamdetectoren om de oliebrandervlam te controleren, zorgt ook voor intermitterende ontsteking.

b) RM7897 vlambeveiligingscontrole maakt gebruik van ultraviolette elektronische vlamdetector om gas- of oliebrandervlammen te monitoren en biedt prepurge programmering.

c) RM7840M, E110/EPD390 vlambeveiliging controleert de olie- of gasbrandervlam en zorgt voor prepurge en postpurge programmering. Getimede laagbrandstart wordt geleverd door middel van de timing ingebouwd in controle. De besturing wordt gebruikt met UL-aan-uit (lage brandstart) systemen. Ultraviolet gevoelige elektronische vlamdetector is standaard met infrarood detector beschikbaar.

d) RM7840L, E110/EPD170 vlambeveiliging controleert de olie- of gasbrandervlam, zorgt voor het programmeren van vóór en na de reiniging; biedt schakelmogelijkheden die nodig zijn om een brandsnelheidsmotor zowel in lage als hoge vuurstanden te laten rijden, voorkomt opstarten indien er zich vooraan ontstekingsgrendels openen en met weinig ontsteekbare belichtingscircuit is uitgerust. In het geval dat voorontstekingsschakeling of loopcircuit niet .verbeteren, systeem zal afsluiten op veiligheid. Ultraviolet gevoelige elektronische vlamdetector is standaard met infrarood detector beschikbaar.

Page 4 of the Weil-McLain WJB2 user manual — Opmerkingen
Pagina 4 · klik om te vergroten
Pagina 4

Webster

Opmerkingen

e) RM7800L, E110/EP170 vlambeveiligingscontrole bewaakt de olie- of gasbrandervlam met digitaal uitleesbesturingssysteem, zorgt voor prepurge en postpurge programmering, biedt schakelmogelijkheid die nodig is om het brandsnelheidsvermogen van een motor zowel laag vuur als hoge brandpositie te laten bereiken, voorkomt opstarten indien er voorontstekingssloten open zijn en een lage ontsteekingscircuit heeft. In het geval dat voorontstekingsschakeling of loopcircuit niet .verbeteren, systeem zal afsluiten op veiligheid. Ultraviolet gevoelige elektronische vlamdetector is standaard met infrarood detector beschikbaar.

14. De luchtstroomveiligheidsschakelaar is standaard voor alle gas- en combinatiegas/lichtolieeenheden. 15. Branders worden volledig gemonteerd en bekabeld (behalve gastrein) en in de fabriek getest. 16. Burners opgenomen door Underwriters Laboratories, Inc., State of Connecticut, Fire Marshal staat Massachusetts, stad van New York MEA en anderen.
17. Er kunnen speciale controles worden uitgevoerd om te voldoen aan andere niet vermelde codevereisten. Raadpleeg uw lokale Weil-McLain distributeur/agent of verkoopkantoor.
18. De elektrische-gaspilot is standaarduitrusting voor alle gas- en combinatiegassen/lichtolieeenheden en op olie-units 1688R-1888. De directe vonkontsteking is standaard op lichte olie eenheden 488R-1588. Directe ontsteking met vonk is facultatief op combinatie gas/lichte olie eenheden 488R-1588. Raadpleeg uw lokale Weil-McLain distributeur/agent of verkoopkantoren. 19. Beschikbaar voor lage NOx-toepassingen. Raadpleeg uw lokale Weil-McLain distributeur/agent of verkoopkantoren.
Vlambeveiligingen voorzien van controlesystemen die op de lijst staan per code GASBRANDERS Modelnummer van de ketelULFMCSD-1IRI OOLHOLHLMODOOLHOLHLMODOOLHOLHLMODOOLHOLHLMOD 488R-488RM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897CRM7897CRM7897C RM784 588-988R– –RM7897ARM7897ARM7897A– –RM7897ARM7897ARM7897A– –RM7897ARM7897ARM7897A– –RM7897CRM7897C RM784 988-1888– –RM7897CRM7897CRM7840L– –RM7897CRM7897CRM7840L– –RM7897CRM7897CRM7840L– –RM7897CRM7897C RM784 LICHTBRANDERS Modelnummer van de ketelULFMCSD-1IRI FALFSLHOLHLMODFALFSLHOLHLMODFALFSLHOLHLMODFALFSLHOLHLMOD 488RR8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GRM7897CRM7897CRM7897C RM784 488-588R8184GR8184GR8184GR8184GR8184GR8184GR8184GR8184GRM7897ARM7897ARM7897ARM7895ARM7897CRM7897CRM7897C RM784 688-988R– –R8184GR8184GR8184GR8184GR8184GR8184GR8184G– –RM7897ARM7897ARM7895A– –RM7897CRM7897C RM784 988-1088R– –R8184GR8184GR8184GR8184GR8184GR8184GRM7840L– –RM7897ARM7897ARM7895A– –RM7897CRM7897C RM784 1088-1888– –RM7896CRM7896CRM7840L– –RM7896CRM7896CRM7840L– –RM7897CRM7896CRM7840L– –RM7896CRM7896C RM784 GAS-/LICHTOLIEBRANDERS Modelnummer van de ketelULFMCSD-1IRI OO/FALFSLHOLHLMODOO/FALFSLHOLHLMODOO/FALFSLHOLHLMODOO/FALFSLHOLHLMOD 488R-488RM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897ARM7897A RM784 588-988R– –RM7897ARM7897ARM7897A– –RM7897ARM7897ARM7897A– –RM7897ARM7897ARM7897A– –RM7897ARM7897A RM784 988-1888– –RM7897CRM7897CRM7840L– –RM7896CRM7896CRM7840L– –RM7896CRM7896CRM7840L– –RM7896CRM7896C RM784
Weil-McLain WJB2 — Opmerkingen diagram (page 4)
Afb. 8 · Opmerkingen

Vraag stellen over de Weil-McLain WJB2

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Weil-McLain WJB2

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Weil-McLain WJB2 handleiding-pdf

4 pagina's·1.1 MB·Boiler·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…