Gebruiksaanwijzing /service van het product CMS-16 van de fabrikant Western Telematic
Ga naar pagina of 62
[ Home | User's Guide Archive | NetReach Products | DataReach Products | PollCat Products | Contact WTI ] WTI Part No. 13027 Rev. B CMS-16 Console Management Switch User's Guide 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9514 www.
Warnings and Cautions: No Serviceable Parts Inside; Authorized Service Personnel Only Do not attempt to repair or service this device yourself. Internal components must be serviced by authorized personnel only.
When mounting the unit in an enclosed rack with a ventilation fan at the top of the rack, note that excessive heat generated by devices at the bottom of the rack can be drawn upward and into the ventilation slots of units located at the top. Make certain to provide adequate ventilation for equipment installed at the bottom of the rack.
4.1.2. DC Powered Units ■ 4.2. Configure Option Switches 4.2.1. Default Baud Rate (Sw1, Sw2, Sw3) ■ 4.2.2. Default Handshake (Sw4, Sw5) ■ 4.2.3. Default Response Message Format (Sw6) ■ 4.2.4. Default Command Echo (Sw7) ■ ❍ 4.3. Initialize Unit to Default Settings ❍ 4.
7.1.1.2. Disconnecting Ports ■ 7.1.2. Defining Hunt Groups ■ 7.2. Passive Mode ❍ 7.3. Buffer Mode 7.3.1. Reading Data from Buffer Mode Ports ■ 7.3.2. Port Buffers ■ ❍ 7.4. Modem Mode ❍ 8. Saving and Restoring Configuration Parameters 8.1.
5.4. IP Security Menu ● 5.5. The Copy Port Parameters Menu ● 6.1. The Port Status Screen (Supervisor Mode, Defaults Shown) ● 6.2. The Port Diagnostics Screen (Defaults Shown) ● 6.3. The Network Status Screen ● 6.4. The Port Parameters Screen (RS232 Port Shown) ● A.
Once you have configured the CMS to fit your application, parameters and options can be saved to an ASCII text file on your PC. This allows you to quickly restore user-selected parameters if the unit configuration is accidentally altered or deleted. Saved parameters can also be uploaded to other CMS units.
button, wait for the Port LEDs to flash, and then release the SET button. Note: During initialization, all port LEDs will flash ON three times. ● During initialization, all command-selected parameters will be cleared, and the CMS will revert to the default parameters specified by the Option Switches.
Ports 1 and 2 are System Setup Ports, which are used for communication during set-up and configuration. Note that Supervisor Level command access cannot be disabled at these ports. ● Ports 1 and 2 can either be connected to a PC or modem. Connection to a modem allows control by a remote PC.
3.2. Apply Power to the CMS Connect the CMS to an appropriate power source. Press the Power Switch ON. The ON LED should light, and the RDY LED should begin to flash. When connecting power to a DC unit, please refer to the additional instructions in Section 4.
Perform the following procedure to access the CMS Command Mode, explore basic features, and check for proper operation. Start your communications program (e.g. ProComm) and set it to 9600 bps, 8 bits, no parity, 1 stop bit. 1. Press [Enter] to access the CMS Command Mode.
/T Reset Network Interface +-----------------------+ /D, /E, /I, /T Commands: Add /Y to bypass "Sure (Y/N)?" Figure 3.1: The Supervisor Level Help Screen Port Status Screen: Type /S [Enter] to display the Port Status Screen ( Figure 3.2 ), which summarizes conditions at all Ports.
create a connection between two other ports. To connect Port 2 to Port 3, type /C 2 3 [Enter] . i. While Ports 2 and 3 are connected, Port 1 will still recognize CMS commands. Type /S [Enter] to display the Port Status Screen. The "STATUS" column should now list Ports 2 and 3 as connected, and Port 1 as "Free".
CAUTION: This device should only be operated with the type of power source indicated on the instrument nameplate. If you are not sure of the type of power service available, please consult your local power company.
when communicating with the CMS. This will ensure access to command functions, even if the unit is initialized to default parameters. Note: If the Option Switch configuration is changed, new parameters will not take effect until the unit is initialized as described in Section 4.
Up Down XON/XOFF Down Up Both Up Up None * = Factory Setting 4.2.3. Default Response Message Format (Sw6) When commands are invoked, the CMS can respond with either verbose (English text) or terse (numeric / abbreviated) messages. Response messages are summarized in Section 10.
4.4. Connecting Devices to the CMS Access the Command Mode. 1. Determine which port will be used for connection to the new device (e.g. Port 3). 2. Check Buffer: Type /S [Enter] to display the Port Status Screen. Check the "Buffer Count" column, which lists the amount of data stored in the buffer for each port.
Figure 4.2: CMS Application Example (Not to Scale) The example in Figure 4.2 shows one of many possible installation configurations for the CMS. In this example, ports have been configured as follows: Network Port: The Network Port allows telnet access by remote Supervisors and/or Users.
configuration, connect to any port, or review unit status. Users are only allowed to review status and connect to the ports allowed by their Port Password. Ports 5, 7, and 9 (User Ports): The Port Password "COLOCATION1" has been assigned to these three ports.
Modem Access: To access the command mode via modem, proceed as follows: Dial the number for the external modem connected to the CMS. i. If you have defined the Supervisor Password, a prompt will be displayed. Key in your Supervisor or Port password and press [Enter] .
5.3. Password Functions The CMS features two different types of passwords; the Supervisor Password and the Port (User) Passwords. The Supervisor Password allows system administrators to invoke unit co.
Supervisor Level Commands. In this case, the only way to access the Supervisor Mode, is to reinitialize the CMS to default values as described in Section 4.2 . 5.3.2. The Port Passwords The Port Passwords (or User Passwords) allow system administrators to restrict access to a specific group of ports.
display the System Parameters Menu. Site ID Message: (Up to 32 characters; Default = undefined) Type 1 and press [Enter] , the Site I.D. Prompt will appear. Key in the desired text and press [Enter] . To display the Site I.D., type /J [Enter] . The Site ID is also listed on the Port Status and Port Diagnostic Screens.
To exit a menu or prompt without changing its current value, press [Esc] . ● Passwords and port names are case sensitive. When defining passwords and port names, note the exact text, including the case of each character. ● The "Who" command (/W) can be used to display currently selected parameters for your resident port.
Parameters selected via these menus will stay in effect until the unit is initialized or the /P command is used to reconfigure the port. After initialization, parameters will revert to the defaults specified by the Option Switches. To select port parameters, proceed as follows: Access the Command Mode.
Note: The Port Password is not displayed by the Port Parameters menu. When the Port Password has been defined, the field for this item will read "defined". To display Port Passwords, invoke the /SP or /WP commands as described in Section 6 .
Enter: "<" Previous Port, ">" Next Port, <ESC> Exit ... Figure 5.2: Port Configuration Menu (Modem Mode) When Port Mode (menu Item 7) is set to Modem Mode, the menu will include additional prompts (see Figure 5.2 ), which are used to define the following: 71.
When a Resident Connection is initiated, the CMS will send a message which lists the connected ports, and displays the one character or three character disconnect command that will be required in order to terminate the connection.
contact your network administrator for appropriate settings, and then assign parameters as described in this section. NETWORK PARAMETERS 1. IP Address: (undefined) 2. Subnet Mask: (undefined) 3. Gateway Address: (undefined) 4. IP Security: Off TELNET PORT PARAMETERS 11.
disconnect from a second port (Resident Disconnect). When defining the Logofff Character, note the following: The default Logoff Character is " + ".
Accept Break: Determines whether the port will accept breaks received from the attached device, and pass them along to a connected port. When enabled, breaks received at this port will be passed to any port that this port is connected to, and sent along to the device connected to the other port.
Masks are listed in order of ascending priority; Mask 1 has the lowest priority, and Mask 5 has the highest priority. b. Masks have a cumulative effect; high priority masks supersede the effect of lower priority masks. c. Each IP Address consists of a series of four eight bit numbers.
When using the wild card address "255.255.255.255" to block access by all IP addresses, make certain that at least one higher priority mask permits access by your IP address.
(Note: Ports 1 & 2 will NOT have restricted values changed.) Enter: Parameter # <CR> to define parameter value to copy to all ports, -<CR> to remove all values set, X<CR> to exit WITHOUT copy, <ESC> to copy to all ports and exit .
RS-232 ports. To display the Port Status Screen, access the command mode and type /S [Enter] , the screen will appear as shown in Figure 6.1 . Although both Supervisors and Users can display the Port .
currently connected to the CMS Network Port. Mode: The user-selected Port Mode. This column will read Any (Any-to-Any), Modem, Passive, or Buffer, depending on the configuration selected for the port. ● Buffer Count: Lists the amount of data (in bytes) stored in the buffer for this port.
Port: The Port Number. Note that if this column contains a plus sign ( + ), this indicates that the port will be allowed to access the Supervisor Mode if the appropriate Supervisor Password is entered at login. ● Name: The user-defined name for each port.
NETWORK STATUS LAN STATUS NIC Installed: Yes MAC Address: 00-40-05-6d-a3-ed TELNET PORT STATUS Name: (undefined) Telnet Connection: No Port Connection: Free Buffer Count: 0 CMS> Figure 6.3: The Network Status Screen (Defaults Shown) As shown in Figure 6.
PORT PARAMETERS #03: 1. Port Name: (undefined) 2. Password: (undefined) 3. Baud Rate: 9600 4. Bits/Parity: 8-None 5. Stop Bits: 1 6. Handshake Mode: RTS/CTS 7. Port Mode: Any-to-Any 74. DTR Output: Pulse 8. Supervisor Mode: Permit 9. Logoff Character: + 10.
(User) password, the /W command will only display the Sequence Disconnect, Logoff Character, and the status of the Accept Break item. 7. Operation 7.1. Any-to-Any Mode Any-to-Any Mode Ports can be connected to other Any-to-Any, Passive, Buffer, or Modem Mode Ports by accessing Command Mode and issuing the /C Command.
Invoke the /C command to connect the desired ports. Resident Connect: To connect your resident port to another port, type /C xx [Enter] . Where xx is the number or name of the port you want to connect. The CMS will display the numbers of the connected ports, along with the command sequence that will be required in order to disconnect the two ports.
Character Format (for more information, please refer to Section 5.5.3. ): Three Characters (Default): Uses the format " [Enter] LLL [Enter] ", where L is the selected Logoff Character. The Default Resident Disconnect Sequence is [Enter] +++ [Enter] .
Network Port: To configure the Timeout Feature for the Network Port, invoke the /N command to display the Network Port Configuration Menu as described in Section 5.
Ports 1 and 2 are Modem Mode ports, and modems are installed at both ports. Port 1 is named "MODEM1" and Port 2 is named "MODEM2". 1. Your resident port is Port 4. To connect to the first available Modem, access the Command Mode and type /C MODEM* [Enter] .
Buffer Mode Ports cannot access the Command Mode. ● In order to ensure supervisor access to important command functions, the Buffer Mode is not available to Ports 1 and 2 (SetUp Ports). ● The Buffer Mode is not available at the Network Port. ● 7.
7.3.2. Port Buffers The Status Screen lists the amount of Buffer Memory currently used by each port. The CMS uses buffer memory in two different ways, depending on the user-selected port mode.
8. Saving and Restoring Configuration Parameters After the CMS has been properly configured, parameters can be downloaded and saved as an ASCII text file. Later, if the configuration is accidentally altered, the file with the saved parameters can be uploaded to automatically reconfigure the unit without the need to manually assign each parameter.
name and directory path. Your terminal emulation program will send the ASCII text file to the CMS. When the terminal program is finished with the upload, make certain to terminate the Upload mode. 4. Notes: If the CMS detects an error in the parameters file, it will respond with the "Invalid Parameter" message.
Note: When the upgrade is performed via the Network Port, the CMS will not default the IP Address, Subnet Mask, or Gateway Address. This allows the telnet connection to be re-established after the upgrade procedure is complete. Abort Upload: To cancel the upgrade and return to the command prompt, type 3 and press [Enter] .
Slash Character: Most CMS commands begin with the Slash Character ( / ). ● Apply Command to All Ports: When the asterisk character is entered as the argument of the /D command (Disconnect Port), or the /E command (Erase Buffer) the command will be applied to all ports.
The table below summarizes the various response messages for both the Terse and Verbose modes. Terse Verbose 0 OK 0 RAM Test Passed 1 Connected * 2 Busy 3 Disconnected 4 Invalid Command 5 Are You Sure.
Display Port Status /S[P] [Enter] X (1) (2) X (1) Display Port Diagnostics /SD [Enter] X (1) X (1) Display Network Status /SN [Enter] X Display Port Parameters (Who) /W[P] [n] [Enter] X (2) X (3) Set .
10.4. Command Set This Section provides more detailed information on all CMS commands, sorted alphabetically by name. [Enter] Enter Command Mode In order to set parameters or connect ports, you must first access the command mode as described in Section 5.
Establishes a bi-directional connection between two ports. For more information and command line examples, please refer to Section 7.1 . There are two different types of port connections: Resident Connect: If the /C command specifies one port name or number, your resident port will be connected to the specified port.
Resident Disconnect Sequence or wait for the Timeout Period to elapse (if enabled). Availability: Supervisor Only Format: /D[/Y] <x> [x] [Enter] Where: /Y (Optional) suppresses the "Sure?" prompt. x Is the number or name of the port(s) to be disconnected.
access to command mode. For more information, refer to Section 5.4 . Note: Make certain to record your Supervisor Password for future reference. If the Supervisor Password is lost or forgotten, you will not be able to access Supervisor Level commands.
Format: /J [Enter] Response: Displays Site I.D. Message /N Set Network Port Parameters Displays a menu which is used to define communication parameters for the Network Port. Also allows access to the IP Security function, which is used to restrict network access by unauthorized IP addresses.
/SD Display Port Diagnostics Provides more detailed information regarding the operational status of each port. Note that in User Mode, this screen will only display parameters for the ports that are allowed by the Port Password that was entered at log in.
/UF Upgrade Firmware When new versions of the CMS operating firmware become available, this command is used to update the existing firmware as described in Section 9 . Note that this command will only function at the Network Port and at Setup Ports One and Two.
Availability: Supervisor / User Format: /X [Enter] Response: Disconnected Appendix A. RS232 Port Interface Figure A.1: RS232 Port Interface DCD and DTR hardware lines function as follows: When connected: If either port is set for Modem Mode, the DTR output at either port reflects the DCD input at the other end.
RS232 Port Interface: 16 RS232 serial inputs use DB9 connectors configured as DTE ports. ● Network Interface: 10Base-T Ethernet, RJ45 ● Coding: Asynchronous, 7/8 bits ASCII. ● Parity: Even, Odd, None ● Stop Bits: 1 or 2. ● Data Rate: 300 to 115.
Trademark and Copyright Information WTI and Western Telematic are trademarks of Western Telematic Inc.. All other product names mentioned in this publication are trademarks or registered trademarks of their respective companies. Information and descriptions contained herein are the property of Western Telematic Inc.
Een belangrijk punt na aankoop van elk apparaat Western Telematic CMS-16 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Western Telematic CMS-16 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Western Telematic CMS-16 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Western Telematic CMS-16 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Western Telematic CMS-16 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Western Telematic CMS-16 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Western Telematic CMS-16 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Western Telematic CMS-16 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.