Gebruiksaanwijzing /service van het product UL-ES-RichboroSE-WH06 van de fabrikant Westinghouse
Ga naar pagina of 24
UL-ES-RichboroSE-WH06 MR OWNER'S MANUAL MANUAL DEL USUARIO Richboro SE TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: Net W eight: 12.
2 UL-ES-RichboroSE-WH06 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer .
3 UL-ES-RichboroSE-WH06 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1996), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga.
4 UL-ES-RichboroSE-WH06 FEA TURES CARACTERÍSTICAS DOWNROD INST ALLATION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLATION INST ALACIÓN.
5 UL-ES-RichboroSE-WH06 COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor , or change the style with just a flip of the blade. NOTE: Combo-Blade finishes vary , depending upon model.
6 UL-ES-RichboroSE-WH06 Unpack and inspect fan carefully to be certain all contents are included. T urn off power at fuse box to avoid possible electrical shock.
7 UL-ES-RichboroSE-WH06 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remove) the screws in the mating slots (2) on the canopy .
8 UL-ES-RichboroSE-WH06 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir .
9 9 UL-ES-RichboroSE-WH06 FLUSH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS 6 Guide motor wires through the base of the canopy as shown and attach canopy directly to top of motor housing with flush mount screws and lock washers provided. Tighten screws securely .
10 UL-ES-RichboroSE-WH06 8 2 1 3 Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place.
11 UL-ES-RichboroSE-WH06 EXTENDED DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL MÁS LARGA 10 Slide downrod ball (1) off of downrod and remove pin (2). Deslice la esfera de la varilla vertical (1) hasta separarla de la varilla vertical y quite el pasador (2).
12 UL-ES-RichboroSE-WH06 12 Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place.
13 UL-ES-RichboroSE-WH06 MOUNTING MONT AJE 14 With bracket holding fan assembly , make electrical connections using the following step for wiring instructions. Con la pieza de montaje sujetando el conjunto del ventilador , haga las conexiones eléctricas de acuerdo a las siguientes instrucciones de cableado.
14 UL-ES-RichboroSE-WH06 WIRING OPTIONS OPCIÓN DE CABLEADO 16 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan.
15 UL-ES-RichboroSE-WH06 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIELORRASO SECURE TO CEILING ASEGURE EL VENTILADOR AL CIELORRASO 1 The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3).
16 UL-ES-RichboroSE-WH06 Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided. Tighten screws securely . NOTE: Some models do not utilize motor gaskets, washers, or stabilizer tabs.
17 UL-ES-RichboroSE-WH06 20 21 22 Install light bulbs (not included). Slide fan pull chain through hole in glass bowl and metal cap. Instale las bombillas de luz (no incluidas). D eslice la cadena de tiro a través del agujero de la esfera de vidrio y la tapa de metal.
18 UL-ES-RichboroSE-WH06 Operation T urn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
19 UL-ES-RichboroSE-WH06 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
20 UL-ES-RichboroSE-WH06 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart.
21 UL-ES-RichboroSE-WH06 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos.
22 UL-ES-RichboroSE-WH06 UL_RichboroSE 1/20/06 9:31 AM Page 22.
23 UL-ES-RichboroSE-WH06 P AR TS LIST LIST A DE REPUESTOS # Description 1 . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . .
UL-ES-RichboroSE-WH06 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, P A 19154 U.S.A. Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registere.
Een belangrijk punt na aankoop van elk apparaat Westinghouse UL-ES-RichboroSE-WH06 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Westinghouse UL-ES-RichboroSE-WH06 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Westinghouse UL-ES-RichboroSE-WH06 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Westinghouse UL-ES-RichboroSE-WH06 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Westinghouse UL-ES-RichboroSE-WH06 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Westinghouse UL-ES-RichboroSE-WH06 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Westinghouse UL-ES-RichboroSE-WH06 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Westinghouse UL-ES-RichboroSE-WH06 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.