Contents Safety information 2 Electrical requirements 3 Installing dehumidifier 4 Operating dehumidifier 5 Removing and emptying water bucket 6-7 Water level float and automatic shutoff 8 Caring for your dehumidifier 9 If you need assistance or service 10-11
Part No. 1182965 Rev. A

Your safety and the safety of others
are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or ‘“WARNING.” These words mean:
You can be killed or seriously injured if you don’t immediately follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
It is your responsibility to:

WARNING Grounding instructions:
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
For your personal safety, this dehumidifier must be grounded.This dehumidifier is equipped with a power supply cord having a 3-prong ground plug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15- or 20-ampere fused and properly grounded electrical supply is required. A time-delay fuse or time-delay circuit breaker is recommended. Use a separate circuit to connect only the dehumidifier.

Installing dehumidifier
Good air circulation is needed for best performance—allow at least 12-18 inches (30.5 - 45.7 cm) of air space on all sides of the dehumidifier.
Keep all outside doors, windows and other openings closed when operating dehumidifier. Humid outdoor air will increase dehumidifier workload.
12-18" (30.5 - 45.7 cm)
12-18" (30.5 - 45.7 cm)
Install dehumidifier on a level floor strong enough to support the dehumidifier with a full bucket of water.
65° (18.3°C)
65° (18.3°C)
If ice forms on coils, some dehumidifiers will continue to run. Some dehumidifiers have a de-icer feature that will automatically shut the compressor off when ice forms. (Fan continues to run.) Unplug either type of dehumidifier until ice melts and room temperature rises.
Install your dehumidifier in an area where the temperature will not fall below 65°F (18.3°C). Lower temper- atures will cause ice to form on coils.
❤ · ❤

EMPTY/ADJUST BUCKET light:
DRYNESS CONTROL: This controls the amount of moisture in the room.Turn the control knob clockwise for more drying.Turn the control knob counterclockwise for less drying.Turn control knob to “NORMAL” to maintain average humidity conditions. NOTE: For the first few days of use, turn the Dryness Control clockwise to “DRYEST”to remove extra moisture from the furnishings as well as the room air.
O
R
MA
HIGH
EMPTY/ADJUST
BUCKET
D
R
Y
S
E
LOW
T
OFF CONTINUOUS
FAN SPEED
DRYNESS CONTROL
FAN SPEED:
Some models: this controls fan operation. Use desired setting. HIGH - for faster moisture removal. LOW - for slower moisture removal.


Sickness Hazard Do not drink water collected in water bucket. Doing so can result in sickness.

Drain hose connection method: (to drain water from bucket continuously)
Do Not damage outside or connection will leak.
center of drain hose connector
drain hose connector cover (not on all models)
If your dehumidifier has a drain hose connector cover, use a flat- blade screwdriver to remove cover from drain connector.Turn cover counterclockwise. Discard cover. It cannot be reused. Go to Step 2.
To use the bucket without the garden hose: For bucket style 1: Use a garden hose cap to seal the drain hose connector.
For bucket style 2: Use a garden hose cap to seal the drain hose connector. Replace drain hose connector cover.

For models with adjustable Water Level Float:
All dehumidifiers have automatic shutoff and a water level float. Some dehumidifiers feature an adjustable Water Level Float.The bucket must be properly aligned for the Water Level Float to work.
You can set the adjustable Water Level Float at the “high”or “low”position. Both settings will turn off the dehumidifier automatically.
The Water Level Float will shut off the dehumidifier automatically.
“High”setting: Water Level Float is preset to the “high”position—left side of opening.The dehumidifier will shut off automatically when bucket is 3/4 full.
“Low”setting: Slide Water Level Float to “low”position—right side of opening — to make the bucket lighter to carry. The dehumidifier will shut off automatically when bucket is 1/2 full.


General cleaning and maintenance 1. Dust the front grille and side panels with a soft brush or the dusting attachment of your vacuum. 2. If cabinet paint chips, you can touch up the paint with a good grade enamel paint to prevent rust.
Every few weeks,rinse the inside of the water bucket with a mild detergent to prevent growth of mold,mildew and bacteria.
Have an authorized servicer clean and service the interior coils of your product annually.

If you need service or call with a question, have this information ready:
Store Model and serial numbers are located on the wall behind the water bucket.
Unit runs but does not dehumidify: • Is unit in defrost cycle? (Provided on some models.)
Consumer Assistance Center c/o Correspondence Dept. 2000 North M-63 Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.

If you need further assistance, you can write to:
Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga, Ontario L5N 3A7
Please include a daytime phone number in your correspondence.
Contact your nearest direct service branch or authorized servicing outlet to service your appliance. (See list below.)
ONTARIO Ottawa area 1-800-267-3456 (except 807 area code) Outside the Ottawa area 1-800-807-6777
MANITOBA, SASKATCHEWAN and 807 area code in ONTARIO 1-800-665-1683
QUEBEC Montreal (except South Shore) 1-800-361-3032 South Shore Montreal 1-800-361-0950 Quebec City 1-800-361-1523 Sherbrooke 1-800-567-6966

Part No. 1182965 Rev. A 2/02 ©2002 All rights reserved Printed in U.S.A.

Contenido Información de seguridad 2 Requisitos eléctricos 3 Cómo instalar el deshumidificador 4 Instrucciones de operación 5 Cómo sacar y vaciar el balde de agua 6-7 Flotador de nivel del agua y desconexión automática 8 Cuidado de su deshumidificador 9 Si necesita ayuda o servicio técnico 10-11
Parte No. 1182965 Rev. A
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.