Gebruiksaanwijzing /service van het product and 734CG van de fabrikant Belshaw Brothers
Ga naar pagina of 42
Gas Fryer Models 718LCG, 724CG, and 734CG Operator’s Manual Serial # W 06060001 - on If you accept the machine from the shipping company, you are, in effect, saying that the machine is in good condition, and you must pay for the machine.
EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by _____________________________________________________________________ Installed by __.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN iii Contents Sections 1 Installation 1 Confor.
B Donut-Making Helps B-1 Tips on Making Quality Cake Donuts B-1 Calculating Correct Water Temperature B-2 Ratios of Plunger Sizes to Donut Weights B-2 Temperature Conversion B-2 C Parts Lists C-1 Limi.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN v Preface The 718LCG, 724CG, and 734CG Gas Fryers are designed to fry cake and yeast-raised donut products.
Contact Belshaw Brothers at 1-800-578- 2547 to obtain necessary parts and instructions..
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 1 1 Installation In a prominent location, post instructions to be followed in the event the user smells gas.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers The workstation should allow at least 2”/5 cm clearance between the machine and all construction, whether combustible or noncombustible.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 3 3. Put the heat shield and splash shield on the fryer. They slide over the flue stack, and the back of the kettle slides between the heat shield and the splash shield.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers gas supply line on the fryer itself is 1/2”/1.3 cm I.P.S.) b. Connect the fryer to the building’s gas supply.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 5 Operation 2 Taking Safety Precautions In a prominent location, post information about what to do if there is a gas leak.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 4. Move the on/off switch to the OFF position. 5. Rotate the gas control knob counterclock- wise to the ON position.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 7 CAUTION To avoid damaging the machine, do not operate the conveyor until all the shortening has melted.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 8 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 3 Cleaning For your safety, observe the following warnings throughout the entire cleaning process.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 9 WARNING Do not allow the shortening to overflow the containers. Shortening will get on the floor, and if the shortening is not cool enough, you may be burned.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 10 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers WARNING Do not allow the cleaning solution to overflow the containers. Cleaning solution will get on the floor, and if the solution is not cool enough, you may be burned.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 11 Maintenance 4 SB-0308 rev 3 AFFECTS: OPEN KETTLE FRYERS PURPOSE: PROGRAMMING THE OGDEN ETR-9000 TEMPERATURE CONTROLLER NOTE: Use Rev.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 12 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Menu Overview: There are three main menus that contain parameters that require programming; they are User Menu, Setup Menu, and Calibration Mode.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 13 Open Kettle Fryer Parameter Settings Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory settings.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 14 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 1 - Parameter Descriptions Set to 37.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 15 Table 2 - Parameter Descriptions Set to .
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 16 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 3 - Parameter Descriptions Set to.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 17 5 Troubleshooting If you have a problem with your fryer that you cannot solve, call your dealer or another qualified technician.
.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-1 A Pilot Module This appendix contains supplemental information about the Honeywell S8600 Intermittent Pilot Module.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers module will not energize the second main valve, and the main burner will not light.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-3 Figure A-1. Normal Operating Sequence. ST A R T TRIAL FO R IGN ITIO N MA I N BUR NE R OP E R A T ION T her mos tat c al l s for heat.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Step 5: Check Normal Operation 1. Set the fryer’s thermostat above 200°F/93°C. 2. Watch to see whether the pilot lights smoothly when the gas reaches the pilot burner.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-5 A common ground, usually supplied by the pilot burner bracket, is required for the module and the pilot burner/igniter-sensor.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers c. Make sure the electrical connections are clean and tight. Replace damaged wire with moisture-resistant #18 wire rated for continuous duty up to 221°F/105°C.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN B-1 B Donut-Making Helps Tips on Making Quality Cake Donuts • Use the correct batter temperature.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 B-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Calculating Correct Water Temperature The following is an example of how to calculate the correct water temperature to use.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-1 C Parts Lists The following pages contain lists of the parts that make up the 718LCG, 724CG, and 734CG Gas Fryers.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 718LCG PARTS LIST.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-3 718LCG PARTS LIST (CONT’D) ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 724CG PARTS LIST.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-5 734CG PARTS LIST.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 0080A 5.
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-7 734FG PARTS LIST ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC.
.
Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 1 US/Canada/Mexico Limited Warranty and Return Policy Belshaw Brothers Inc.
Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 2 Exclusions This warranty excludes from its coverage and does not apply to: (a) solenoid and relay coils; (b) lamps; (c) “O” rings; (d) belts; and (e) impellers.
Een belangrijk punt na aankoop van elk apparaat Belshaw Brothers and 734CG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Belshaw Brothers and 734CG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Belshaw Brothers and 734CG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Belshaw Brothers and 734CG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Belshaw Brothers and 734CG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Belshaw Brothers and 734CG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Belshaw Brothers and 734CG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Belshaw Brothers and 734CG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.