Gebruiksaanwijzing /service van het product W4GH6 van de fabrikant Whirlpool
Ga naar pagina of 20
H EA T P UM P INSTALLATION INSTRUCTION S HEAT PUMP SAFETY INSTALLATION RE QUIREMENTS These inst ructions are intend ed as a general guide only for use by qualified persons and do not su persede any na tional or local codes in any way .
2 To o l s a n d P a r t s Gat her the r equ ir ed to ols and pa rts bef or e star tin g instal lati on. Read and fol low the instruction s provided with an y tools listed here.
3 Minimum Clearances Line Set Isolation The follow ing illustrati ons demonstrate procedures which ensure proper refrigerant line set i solation. Installing Horizontal Runs This sh ows how to instal l line se ts on horizon tal runs .
4 Ele ct rica l R equir em ents NOTE : All outdoor wiri ng must be suitable for outdoor u se. Use copper conductors only . ■ All field w iring must be don e in accordance with National Electrical Code requirements, ap plicable requirements of UL, or local codes, where applicable.
5 1. Discon nect powe r . 2. Remove the refriger ant from the existing system per the manufacturer’ s in structions provided with the recovery system bei ng used.
6 17. Inst all the val ve cores. 18. Install the R-410A thermal exp ansion valv e specified for t his system in the indoor coil. NOTE : R-410A s ystems use only thermal ex pansion valv es. 19. Pressurize the line s and indoor coil with a pressure not to exceed 20 ps ig.
7 6. Tighten to 20 to 3 0 ft lbs. Use backup wrench on all wr ench flats. NOTE : Overti ghtening may c rush the T eflon ® seal and c ause a leak. 7. Connect the ext ernal equal izer line to the equa lizer port on the suct ion line. 8. Tighten to 8 ft lbs.
8 Normal Op erating Pressures NOTE : V alues p r ovided in ch art are typical pressures. Indoor un it matchup, ind oor air quality and indoor load will cause pressures to vary .
9 Suction Line Sizes Installa tions exceed ing 100 ft are not recommended. Liquid Line Si zes Installa tions exceed ing 100 ft are not recommended . Make Elect rica l Connectio ns IMPORTANT: ■ Electrical wiring, disconnect means and over -current pr otec tio n ar e to be su ppli ed by the i nst aller .
10 4. Connect grou nd wire to groun d lug. 5. Connect lo w voltage circuit. T yp ical Wiring Connection (low voltag e circuit) 6. Replace control box c over . 7. Reconnect pow er . A. Ground lug B. Field supply ground w ire C. 208/230 volt field supply wires T1 T2 L1 L2 L1 L2 C A B A.
11 Outdoor Unit T ypical Wiring Diagram Complete Installat ion 1. Operate the heat pu mp for a period of at leas t 15 minutes to allow for pressures and te mperatures to stabil ize. 2. If heat pump doe s not appear to be fu nctioning correctly , have heat pu mp checked by a person cert ified by the EP A to handle refrig erant.
12 SEQUENCE OF OPERATION Cooling C ycle Upon cooling demand, the the rmostat closes circuit R to O an d Y . Closing R to O and Y ener gizes the reversing valve for cooling operation and closes the heat pump cont actor , starting the compressor and outdoor fan.
13 Time Delay The time d elay is 5 minut es long. The delay helps to p rote ct the compressor from short cycling in case the power to t he heat pump is int errupted or a pressure switch opens. The d elay is bypassed by placing the t imer select jumper across th e TEST pins f or 0.
14 2. Remove the heat er compartment acc ess panel. 3. Adjust the time period between defrost cycle s by placing t he defrost time plu g in t he proper positio n. See “ Defrost Control Board.” ■ For 30-minute intervals betw een defrost cycles, connect the Defrost Time Settin g Plug to the pins corr esponding to 30.
15 TROUBLESHOOTING Heat Pump Fails to Operate Properly Review “Sequ ence of Operatio n” and visuall y inspect th e heat pump befor e troubleshooting: System Diagnostic Module W4GH6 heat pumps c ontain a diagno stic module for troubleshootin g heat pump system fail ures.
16 24 V AC Power Wiring The di agnost ic module r equires a const ant nomin al 24 V AC power supply . The wiring to the module’ s R and C terminals must be directly from the indoor unit or thermost at. The module cannot be pow er ed by R an d C te rminals o n the defr ost b oar d wi thout experienci ng nuisance ale rts.
17 Incorrectly Wired Module Codes Depending on the s ystem configuration, some Alert flash codes may not be act ive. The presence of safet y switches affects how the syst em alerts are display ed by the module. Incorrectly wiri ng the diagnostic modu le will cause false LED codes.
18.
19 Keep this book an d your sales s lip together for futur e ref erence. Y ou must pr ovide pro of of pur chase o r installation date for in-warranty service. Wr ite d own the f ollow ing in format ion ab out y our Spl it Syst em Heat Pump—Outd oor Section to better help you obtain assistanc e or service if you ever nee d it.
48488 A006 © 200 6. All rights reserved. ® Registe red Tradem ark/TM T rademark of W hirlpool, U .S.A., Manufactur ed under license by Tradewin ds Distributi ng Compan y, LLC.
Een belangrijk punt na aankoop van elk apparaat Whirlpool W4GH6 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Whirlpool W4GH6 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Whirlpool W4GH6 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Whirlpool W4GH6 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Whirlpool W4GH6 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Whirlpool W4GH6 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Whirlpool W4GH6 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Whirlpool W4GH6 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.