Gebruiksaanwijzing /service van het product 081310 van de fabrikant WhisperKool
Ga naar pagina of 34
SPLIT SY STEM OWNER’ S MANU AL To b e u s ed w iT h y ou r sys T em’s uNiT specific iNsT alla TioN Guide The Coolest Thing In Wine Stor age.
P age 2 GSM-01 081310 Copyright © 2010. WhisperKOOL. All rights reserved. This manual, the pr oduc t design, and the design conc epts are copyrighted by WhisperKOOL, with all rights r eser ved.
P age 1 Introduction ............................................................................................................. Receiving & Inspec ting The Unit................................................................................. Pr eparing the W ine Cellar .
P age 2 GSM-01 081310 Cust omer S ervice Thank you f or purchasing a WhisperKOOL split sy stem. We striv e to provide the highest quality products and the best possible customer service. If you have an y questions about your WhisperKOOL unit, please call us at 1(800) 343-9463 or visit ww w .
P age 3 Cust omer W arranty Registration PLEASE C OMPLE TE AND RETURN THE W ARRANT Y CARD UPON RECEIPT OF THE UNIT . By completing the Pr oduc t Registration C ard, you will be conrmed in our cust omer database ensuring that your inf or mation is on le to help y ou obtain ecient warranty ser vice.
P age 4 GSM-01 081310 The per f or mance and lif e of your WhisperKOOL sy stem are contingent upon the steps y ou take in preparing the wine cellar . Note: Improperly preparing your enclosur e or incorrectly installing your WhisperKOOL syst em may cause unit failure , leak ing of condensation, and other negative side e ects.
P age 5 Unobstructed Air ow Unobstructed air ow to and from both the ev aporator and condenser is a critical factor in the system ’ s over- all per formance . Make sure there is a 3 ft. horizontal clearance in the fr ont of both units. This will assure that the air can circulate in an ecien t manner .
P age 6 GSM-01 081310 General Installation Guidelines and Instructions WhisperK OOL requires that a certied HV AC technician install and char ge all split systems. Please take a moment to review sta te and city building codes to ensure the safe and pr oper installation of the system.
P age 7 Installing the Condensing Unit The condensing unit can be mount ed inside a utilit y area of the home or outside utilizing the r equired outdoor condensing unit housing . The condenser requires a dedica ted 20 amp circuit, non-GFI. Make sure there is a minimum three-foot horizontal clearanc e in front and rear of the unit.
P age 8 GSM-01 081310 Installing the Evapor ator Unit Please ref er to the supplied Unit Specic Installation Guide for detailed ev aporator installation guidelines . Head Pressur e Control , Low Ambient C ontrol S witch, F an C ycling Switch: These switches ar e used to c ycle the condenser fan a t low ambient temperature c onditions.
P age 9 If you have a sy stem with a remote keypad, please r eview this sec tion for installa tion. Note: 50 f eet of communication line is included, the keypad can be installed up to 300 line feet a way . Lon- ger lengths of communication line can be order ed by calling 1-800-343-9463 ext.
P age 10 GSM-01 081310 Ducting the supply and return air to the cellar creat es a vir tually silent cellar space and also maximizes cellar capacity . I t is absolutely crucial to only use insula ted duc t work as it minimizes c ooling loss, prevents sw eat- ing, and r educes noise.
P age 11 LIQUID MEASURING THERMOMETER Most WhisperKOOL syst ems come equipped with a liquid temperature measuring thermometer pr obe . This self calibrating probe c ontains a sensor chip, which actually communicates back and f or th to the thermostat.
P age 12 GSM-01 081310 Initial Start-Up When pow er is applied to the unit, the control will briey display all symbols, and the Sno w Flake symbol will be displayed (if unit is calling f or cool- ing).
P age 13 C ONTROL P ANEL OPER A TION Button Normal F unc tions ON/OFF • The ON/OFF button allow s the customer the convenienc e of turning the refrigeration system ON or OFF , from the contr ol panel. This fea ture does not disconnect power from the unit , and the condenser fan will continue t o run in the OFF position.
P age 14 GSM-01 081310 Energy Reduc- tion (ER) 1. The ER fea ture can be used to save ener gy and aids in ex tending the lif e of the system. 2. The ER button is locat ed at the top L/H side of the control . The ER feature is activated b y pressing the ER button one time , and the ER logo will appear on the digital display .
P age 15 CPSM Mode (C ont.) C CS – Cellar Pre- Chill Set P oint: This parameter is set at 52°f , but can be adjusted to a set point between 45°f - 67°f . bLL/Act – Compressor O or On for L ow (bLL) or High (Act) T emperature Alarm: These param- eters are set at “n ” .
P age 16 GSM-01 081310 MAINTENANCE SCHEDULE Monthly 1. Check lters 2. Check for unusual noise or vibr ation Quar terly Clean lters: 1. Remov e grille/duc ting on the evapora tor 2. Remov e the lter cov ering the coil 3. W ash with warm wat er 4.
P age 17 TROUBLESHOO TING F ault Cause Solution W ater leaking from unit 1. Condensat e drain clogged Clear out drain 2. Evaporat or coil froz en Clean the coil and / or fan wheel 3. Drain line impr operly installed Call a CERTIFIED HV AC service technician.
P age 18 GSM-01 081310 If the breaker remains set, check to see if c ompressor is running and condenser fan turns on. After compressor runs a f ew minutes, check the refrigeran t “ sight glass” in the ¼” copper tubing. L ook for bubbles. If no bubbles are present and compr essor is running, refrigerant sy stem is running OK .
P age 19 7. System lo w on refrigerant. Check refrigerant “ sight glass” in 1/4” tubing. Check for bubbles after system has run f or several minutes. If bubbles presen t, call a CER TIFIED HV AC service technician. If sight is clear of bubbles, r efrigerant level is OK.
P age 20 GSM-01 081310 Compr essor runs, but evapora tor does not 1. F ault y blower motor or broken wir e connection • Evaporat or coil probably froz en • Shut o power t o condensing unit • Call a CERTIFIED HV AC service technician for repair 2.
P age 21 5. Evaporat or blower not running • F ault y blower mot or or broken wire connection. • Call a CERTIFIED HV AC service technician 6. Obstruction to air ow Check for obstruction to air ow and r epair 7.
P age 22 GSM-01 081310 WIRING DIA GRAMS Platinum Split 4000 & 8000 E vaporator T erminal B oard Ser v es Color Line 1 Black Neutral Whit e Solenoid Valv e Blue Evap B Black Remote to K eypad - Black + Red /Users/Mark eting/Mark etingDept/M anuals/Generic Split Manual 12 12 packaged/Links/Mini Split W iring .
P age 23 Platinum Split 4000 & 8000 C ondenser T erminal B oard.
P age 24 GSM-01 081310 Mini-Split Evapor ator T erminal Board.
P age 25 Mini-Split Condenser T erminal B oard.
P age 26 GSM-01 081310 TECHNICAL ASSIST ANCE WhisperK OOL Customer Ser vice is available Monday thr ough Friday fr om 8:00 am to 4:00 pm PST . The Cust omer S ervice representativ e will be able to as.
P age 27 INST ALLA TION TERMS AND C ONDITIONS WhisperK OOL Split Sy stem PLEASE READ THESE TERMS AND C ONDITIONS CAREFULL Y BEFORE INST ALLING Y OUR WhisperK OOL Split System.
P age 28 GSM-01 081310 REP AIR OR REPLACEMENT PURSU ANT T O THE LIMITED W ARRANT Y IS THE EX CLUSIVE REMEDY OF THE C ONSUMER FOR ANY DEFEC TS IN WHISPERKOOL PRODUC TS.
P age 29 the unit, WhisperKOOL will co ver the costs of the evaluation by the certified HV AC technician. If the product is malfunc tioning due to the improper installation or some other act or omissi.
P age 30 GSM-01 081310 Any disputes ar ising out of or in connection with the installation and warranty of the Split System shall be referred to and finally resolved by a WhisperK OOL approv ed Independent Certified HV AC T echnician.
NO TES.
WhisperK OOL 1738 E. Alpine A ve Stockton, CA 95205 1(800) 343-9463 ww w .whisper kool.c om.
Een belangrijk punt na aankoop van elk apparaat WhisperKool 081310 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen WhisperKool 081310 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens WhisperKool 081310 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding WhisperKool 081310 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over WhisperKool 081310 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van WhisperKool 081310 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de WhisperKool 081310 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met WhisperKool 081310 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.