MODEL: PRS2 PRSD2 Operating Instructions (USA) Mode d’emploi (FR) Bedienungsanleitung (GER) Instrucciones de Funcionamiento (SPA) MODEL: PRSIFB2 PRSDIFB2 PRSIFE2 PRSDIFE2 PRSIFA2 PRSDIFA2 IPX4 98902 08/19/04 G Read instructions before operating the machine.
MACHINE DATA LOG/OVERVI EW PRSIF2/ PRSDIF2 98902 12/2 8/01 2 For the name and address o f your dealer contact: Windso r Industries YOUR DE ALER Name: _____________________________________________ ____.
TABLE OF CONTENTS PRSIF2/ PRSDIF2 98902 06/28/03 3 Machine Data Log/Overview. ......................... 2 Table of Contents ........................................... 3 HOW TO USE THIS MANUAL How to use this Manual. ................................ 1-1 SAFETY Important Safety Instructions .
PRSIF2/ PRSDIF2 98902 12/2 8/01 4 THIS PAGE LEFT BLANK INTENTIONALLY.
HOW TO USE THIS MANUAL PRSIF2/ PRSDIF2 98902 02/01/03 1-1 This manual contains the following sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
PRSIF2/ PRSDIF2 98902 12/2 8/01 2-1 IMPORTANT SAFETY INSTRUCTIONS When using an el ectrical applianc e, basic prec aution must alw a y s be follow ed, includi ng the foll owing: READ ALL INSTRUCTIONS BEFORE USING THIS M A CHINE. To reduce the risk of fire, electric shock , or injury : Use only in doors.
HAZARD INTENSITY LEVEL PRSIF2/ PRSDIF2 98902 12/2 8/01 2-2 The follow ing symbo ls are used thro ughout this gu ide as in dicated in their descr iptions: HA ZARD IN TENSITY LEVEL There are three lev els o f hazard inte nsity ide ntified by signal w ords - WA RNI NG an d CA UTION an d FOR SAFETY .
GROUNDING INSTRUCTI ONS PRSIF2/ PRSDIF2 98902 12/2 8/01 2-3 THIS PRODUCT IS FOR COMM ERCIAL USE ONLY . ELECTRICA L: The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
MACHINE OPERATIONS PRSIF2/ PRSDIF2 98902 12/2 8/01 3-1 SET UP AND OPERATION 1. Upon rem oving your new m ini-extr actor fr om the box, loosen the latch at bac k end of the mac hine that secures the reco ver y tank to the s olution tank. Rem ove the rec overy tank from the solution tank .
MAINTENANCE PRSIF2/ PRSDIF2 98902 12/2 8/01 4-1 DA ILY MAINT ENA NC E : Follo w same proc edure for Shut Do wn and Stor age. PER IODIC MA INTENA NCE : 1. Twice a month, flush a wh ite vin egar solut ion (one quart vineg ar to tw o gallons water) or anti- browning s olutio n (m ixed as dir ected) through the extractor.
TROUBLESHOOTING/WIRING DIAGRAM PRSIF2/ PRSDIF2 98902 02/08/03 4-2 TROUBLESHOOTING PROBLEM . CAUSE SOLUTION Little or no solution flow Clogged spray jet on cleaning tool Remove and clean jets Faulty pump Check and replace pump.
RECOVERY TANK PARTS PRSIF2/PRSDIF2 98902 06/28/03 5-1 3 4 PARTS INSIDE PORTAL CAP 14 13 2 1 8 6 5 7 12 9 11 5 10.
RECOVERY TANK PARTS LIST PRSIF2/PRSDIF2 98902 08/19/04 5-2 REF PART NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 05160 1 ASM, ACCESS COVER 2 70546 6 SCR, 8 X ¾ PFHT/S BLK ZINC 3 34391 1 FLOAT ASM SPO.
SOLUTION TANK PARTS PRSIF2/PRSDIF2 98902 02/01/03 5-3 * *.
SOLUTION TANK PARTS LIST PRSIF2/PRSDIF2 98902 02/01/03 5-4 REF PART NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 75367 1 TANK, SPOTTER SOL DK GRY 2 40066 3 HOSEBARB, 1/8NPT X 3/8 90D PLASTIC 3 270-11A.
LABELS & PARTS LIST PRSIF2/ PRSDIF2 98902 12/2 8/01 5-5 RE F PA RT N O. QTY DESCRIPTION SER IAL NO. FROM NOT ES: 1 500009 1 LABEL, W ARNING 2 500528 2 LABEL, P REST O MAIN 3 500529 2 LABEL, W INDSOR LOGO 6 X 1.
PRESTO HAND TOOL & PARTS LIST PRSIF2/ PRSDIF2 98902 12/12/02 5-6 REF PART NO. DESCRIPTION SERIAL NO. FROM NOTES: 1 41422 HOUSING, HANDTOOL SPOTTER 2 20053 CLAMP, DHT VALVE 3 39593 HOSE ASM, HOSE/C.
PRESTO CART & PARTS LIST PRSIF2/ PRSDIF2 98902 12/28/01 5-7 REF PART NO. DESCRIPTION SERIAL NO. FROM NOTES: 1 78310 TUBE, CART HANDLE 2 70010 SCREW, 1/4-20 X 1.
PRESTO DELUXE HAND TOOL ASSEMBLY PRSIF2/ PRSDIF2 98902 06/28/03 5-8 REF PART NO. DESCRIPTION SERIAL NO. FROM NOTES: 1 04007 ADAPTOR, 1/8 MPT X 1/8 FPT BR 2 12509 BRUSH, DDH 3 22026 COUPLER, 1.
SUGGESTED SPARE PARTS PRSIF2/ PRSDIF2 98902 06/28/03 5-9 PART NO. DESCRIPTION SERIAL NO. FROM NOTES: 44074 JET ASM W/O-RING 44060 JET, 8002 MINI-QUICK REPLACEMENT 330-13 SWITCH, DPST ROCKER 20A 53802 .
NOTES PRSIF2/ PRSDIF2 98902 06/28/03 5-10.
PRSIF2/ PRSDIF2 98902 12/28/01 5-11.
Een belangrijk punt na aankoop van elk apparaat Windsor PRS2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Windsor PRS2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Windsor PRS2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Windsor PRS2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Windsor PRS2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Windsor PRS2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Windsor PRS2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Windsor PRS2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.