EN Reference Manual.
ACD1 Reference Manual 2 Contents Introduction............................................. 3 About the documentation ................................. 3 Supported amplifiers ......................................... 3 Setup ...........................
ACD1 Reference Manual 3 Intr oduction About the documentation This document explains mainly the operation and specifications of the A CD1 amplifier control de vice itself. When using the A CD1, y ou will also need to consult various manuals other than this document.
ACD1 Reference Manual 4 Introduction T erms This section explains terminology specific to the A CD1. ■ Amp Editor This is computer application software. W ith this software, you can use your computer to monitor and control the A CD1 and the amplifiers connected to the A CD1.
ACD1 Reference Manual 5 Contr ols and Connectors q Display This sho ws information about the scene, the A CD1 itself, or the connected amplifiers. This will light red when an abnormal- ity (a W ARNING or higher alert) occurs. This will also blink blue and white when the Identify operation is performed in Amp Editor.
ACD1 Reference Manual 6 Controls and Connectors y Ground scre w The A C power cord is a 3-wire type. If the A C outlet used is earthed (grounded), this de vice will be properly earthed as well. Also, grounding the scre w sometimes reduces hum and interference noise.
ACD1 Reference Manual 7 Panel operations By pressing b uttons on the panel you can monitor or contr ol various parameters of the A CD1 itself or of the con- nected amplifiers. The f ollowing parameters can be monitor ed/controlled. Category Sub category Operation performed 1.
ACD1 Reference Manual 8 Panel operations The main roles of each b utton are as follo ws. As an example, we’ll explain how to stor e the scene of an amplifier connected to the A CD1.
ACD1 Reference Manual 9 Panel operations 5. Use the [ ▲ INC/YES] / [ ▼ DEC/NO] b uttons to select the ID of the amplifier f or which you want to stor e settings. 6. Press the [NEXT] b utton to move to the scene number . 7. Use the [ ▲ INC/YES] / [ ▼ DEC/NO] b uttons to select the scene number that y ou want to store.
ACD1 Reference Manual 10 Panel operations Here’ s how to r ecall or store scenes for a specified amplifier . ■ Recalling a scene (“1. Scene” ➝ “Recall”) Recalls a scene for the specified amplifier . • If you select “ALL ” as the Amp ID , the scene name will not be displayed.
ACD1 Reference Manual 11 Panel operations These settings allow y ou to control an amplifier connected to the A CD1. ■ Po wer on/standb y (“2. Amp Contr ol” ➝ “Standby”) Switches the po wer of the specified amplifier between On and Standby .
ACD1 Reference Manual 12 Panel operations This indicates the output lev el of the amp connected to the A CD1. ■ Amplifier output (“3. Output Monitor”) Displays the output le vel for each channel of the specified amplifier .
ACD1 Reference Manual 13 Panel operations ■ Identify (“4. Device Setup” ➝ “Identify”) Blinks the “Identify” icon of the corresponding A CD1 in Amp Editor. Here y ou can make overall settings f or the A CD1 and view various types of inf ormation.
ACD1 Reference Manual 14 Panel operations ■ LCD bac klight (“5. Utility” ➝ “LCD Bac klight”) This specifies the lit status of the A CD1’ s LCD backlight. ■ Restricting panel operations (“5. Utility” ➝ “P anel Operation”) Here you can turns panel operation lock on/of f.
ACD1 Reference Manual 15 Panel operations ■ Enabling scene recall operations via EMG commands (“5. Utility” ➝ “EMG Scene Setup”) Specifies whether the EMG scene will be recalled when the EMG (Emer - gency) signal is recei ved. The follo wing three types of EMG signal can be recei ved.
ACD1 Reference Manual 16 Panel operations ■ GPI IN calibration (“5. Utility” ➝ “GPI Calibration”) Calibrates the detected range of the [GPI IN] connector input v oltage. Here y ou can make network settings f or the A CD1. ■ IP Address Mode setting (“6.
ACD1 Reference Manual 17 Panel operations ■ Po rt settings f or an external contr oller (“6. Network Setup” ➝ “IP Ctrl P or t #”) Here you can specify the port number that will be used to control the A CD1 from an external de vice such as an AMX or Crestron unit.
ACD1 Reference Manual 18 Connector wiring This section explains how to wir e the [GPI] and [F A UL T OUTPUT] connectors located on the A CD1’s r ear panel. Be sure to use the supplied Eur oblock connector . If you lose the connector , contact your Y amaha dealer .
ACD1 Reference Manual 19 Connector wiring Connect GPI (General Purpose Interface) de vices (e.g., contr ol- lers) to the rear panel [GPI] connector . Y ou can use GPI to send or r eceive contr ol signals to or from an external de vice. The A CD1 provides 4-port input and 4-port output.
ACD1 Reference Manual 20 Connector wiring Y ou can connect a lamp etc. to the r ear panel [F A UL T OUTPUT] connector to indicate that an abnormality has occurred. The [F A UL T OUTPUT] connector consists of NO (Normally Open), C (Common), and NC (Normally Closed).
ACD1 Reference Manual 21 Appendix Messages that may appear in the A CD1’ s display and the appropriate responses ar e listed below . F or more about alert messages, refer to the Amp Editor o wner’ s manual. The A CD1 allows the f ollowing single-byte characters to be displayed and input.
ACD1 Reference Manual 22 Appendix Tr oubleshooting Symptom P ossible causes Response All scene data sav ed in the ACD1 has disap- peared The power w as tur ned off while the ACD1’ s data was being sa ved Once again synchronize the unit with Amp Editor to transmit the settings from Amp Editor.
ACD1 Reference Manual 23 Appendix *1 Suppor ted models XP7000, XP5000, XP3500, XP2500, XP1000, XM4180, XM4080, XH200 Guaranteed cable length: 50m *2 Suppor ted models T5n, T4n, T3n, PC9501N, PC6501N, .
ACD1 Reference Manual 24 Appendix Unit : mm * Specifications and descr iptions in this owner’ s manual are for inf or mation purposes only . Y amaha Cor p . reserves the right to change or modify products or specifications at any time without prior notice.
U .R.G., Pro Audio & Digital Musical Instrument Division, Y amaha Corporation © 2009 Y amaha Corporation 911-PO-C0.
Een belangrijk punt na aankoop van elk apparaat Yamaha ACD1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Yamaha ACD1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Yamaha ACD1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Yamaha ACD1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Yamaha ACD1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Yamaha ACD1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Yamaha ACD1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Yamaha ACD1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.