Gebruiksaanwijzing /service van het product YM-W9001FL van de fabrikant Yeoman
Ga naar pagina of 35
Fr eestanding Stove INSTRUCTIONS FOR USE, INST ALLA TION AND SERVICING For use in GB & IE (Great Britain and the Republic of Ireland). This appliance has been certified for use in countries other than those stated.
COVERING THE FOLLOWING MODELS: YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YM-W9001ERLC / YM-W9101FL / YM-W9101LC / YM-W9101ERFL /YM-W9101ERLC / YM-W9102FL/YM-W9102LC / YM-W9102ERFL /YM-W9102ERLC / YM-W9.
3 3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information. In the unlikely event of a problem, contact your installer or dealer for assistance.
4 4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.
5 5 USER INSTRUCTIONS AIRWASH & PRIMARY AIR CONTROLS 1.14 Use a gloved hand to operate air controls. The opposite end of the door tool can be used to operate Airwash controls.
6 6 USER INSTRUCTIONS 3. RECOMMENDED FUELS 3.1 Wood Logs: • Burn only seasoned timber with a moisture content of less than 20% Wood Length Appliance Wood Length Exmoor 250mm Exe 300mm Devon 350mm Co.
7 7 USER INSTRUCTIONS • Leave the door slightly open as the fire establishes and the glass warms to avoid the build-up of condensation • Add larger pieces of wood Too many logs may smother the fire. Do not load fuel above the log guard and the secondary combustion holes at the back of the firebox.
8 8 Secondary Air: Fully Closed Primary Air: Adjust Secondary Air: Fully Closed Primary Air: Adjust Air Wash: 25% Open Air Wash: 25% Open 5.7 De-ash the fire bed before re-fuelling, see Section 7 Ash Removal.
9 7. ASH REMOVAL Do not allow ash to build up in the appliance as it will not burn properly and may cause damage. 7.1 Wood : • Open the door • Remove drop-in front plate, Diagram 10 PR7535 10 • .
10 c) It is repaired as required before re-use. Use only genuine Stovax replacement parts to keep your appliance in safe and efficient working order. 11. GENERAL CLEANING 11.1 Clean and inspect your appliance regularly, especially in periods of heavy use.
11 13. CHIMNEY SWEEPING 13.1 To maintain safe and efficient use of the appliance the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep.* If the appliance is used continuously throughout the year or it is used to burn wood, more frequent sweeping is recommended.
12 USER INSTRUCTIONS • Lift out the riddling mechanism and remove all ash • Replace riddling mechanism when cleaning is complete 16.3 Glass cracking: Do not over tighten the screws on the glass clips when replacing the glass as this causes stress and the intense temperature changes can cause the glass to crack.
YEOMAN EXMOOR/EXE/DEVON/COUNTY 13 TECHNICAL SPECIFICATION MODEL: Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC YM-W9102FL.
14 SITE REQUIREMENTS YEOMAN STOVE DIMENSIONS PR7509 Description A B C D E F G H (dia) Exmoor FT 523 437 290 100 407 324 89 125 Exmoor LC 667 447 309 100 407 324 89 125 Exe FT 517 595 307 115 402 351 8.
15 1. FLUE & CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks.
16 2.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in the diagram opposite. 2.2 The building must have a suitable load-bearing capacity for the hearth and appliance.
17 SITE REQUIREMENTS WALLS NEXT TO HEARTH Solid, non-combustible material e.g. masonry or concrete Thickness W H C C 150mm minimum 150mm minimum PR7511 Position of Appliance & Hearth in relation t.
18 PRE-INSTALLATION CHECKS MODEL: Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC YM-W9102FL / YM-W9102LC / YM-W9102ERFL / .
19 PRE-INSTALLATION CHECKS 3.1 This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm 2 per kW of appliance rated output above 5kW.
20 INSTALLATION INSTRUCTIONS LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations and standards*, along with any local regulations and working practices that may apply.
21 INSTALLATION INSTRUCTIONS Typical Top Flue Installation PR7515 600mm minimum 1000mm maximum unsupportable weight To chimney connection as detailed in building regulations Flue Pipe 915mm (3ft) Size Stovax Part No. 5" 4502 6" 4602 135 Elbow Size Stovax Part No.
22 INSTALLATION INSTRUCTIONS PR7525 Baffle Extension Tubes Support Pin Rear Lip 3.2 The front lip of the baffle should point downwards. • Lift the baffle and slide the two baffle extension tubes off of the support pins on the sides of the firebox.
23 • Place the ashpan under the grate • Refit the drop in front plate • Check that the door closes and seals correctly County Model Rear Grate Front Grate Ashpan 5.
24 COMMISSIONING COMMISSIONING 1.1 To commission: • Replace the firebricks, baffle, and log retainer • Check the door alignment and catch operation, adjust if required, see Maintenance & Servicing Section 8&9. Adjusting Door hinges • Check the soundness of door seals, castings and joints • C heck the operation of the air controls 1.
25 25 1. ANNUAL SERVICE 1.1 At the end of the heating season strip, inspect and clean the appliance as detailed: • Allow appliance to cool • Remove all of the following internal parts; drop in front, log guard, baffle, firebricks. For Multi-fuel versions remove the complete grate and ash pan.
26 26 MAINTENANCE and SERVICING 2. REMOVAL OF THE LOG GUARD 2.1 See Section 2 Fitting & Removal of Log Guard in Installation section. 3. FITTING AND REMOVAL OF THE BAFFLE 3.1 See Section 3 Fitting & Removal of The Baffle in Installation section.
27 27 MAINTENANCE and SERVICING PR7531 Seal 12x3 Seal 14mm 2 Door 7.3 Remove the old rope and scrape old glue from the locating grooves. Clean the locating groove with a clean dry cloth to remove all old dust and debris. 7.4 Squeeze a generous bead of fresh Stovax Thermic Seal glue into the rope locating groove (part no.
28 County only Exmoor, Exe & Devon Exmoor only 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 13 B 13 A1 9 25 24 22 17 18 19 20 22 23 21 23 28 BASIC SPARE PARTS LIST Exmoor, Exe, Devon, County S e e a S S e.
29 BASIC SPARE PARTS LIST D i A g r A m N o D e s c r i p t i o N e x m o o r p r o D u c t c o D e e x e p r o D u c t c o D e D e v o N p r o D u c t c o D e c o u N t y p r o D u c t c o D e 1 Flue.
30 BASIC SPARE PARTS LIST D i A g r A m N o D e s c r i p t i o N e x m o o r p r o D u c t c o D e e x e p r o D u c t c o D e D e v o N p r o D u c t c o D e c o u N t y p r o D u c t c o D e 1 Glas.
31 BASIC SPARE PARTS LIST Exe, Devon, County Double Door 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 21 9 D i A g r A m N o D e s c r i p t i o N e x e p r o D u c t c o D e D e v o N p r o D u c t .
32 32 SERVICE RECORDS 1st SERVICE Date of Service: ..................................... Next Service Due: ................................... Signed: ............................................ Dealer’s Stamp/HETAS Registration Number 3rd SERVICE Date of Service: .
33 33.
34 34 Greg T aylor T echnical Director.
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.
Een belangrijk punt na aankoop van elk apparaat Yeoman YM-W9001FL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Yeoman YM-W9001FL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Yeoman YM-W9001FL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Yeoman YM-W9001FL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Yeoman YM-W9001FL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Yeoman YM-W9001FL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Yeoman YM-W9001FL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Yeoman YM-W9001FL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.