Gebruiksaanwijzing /service van het product AK6000 van de fabrikant Zephyr
Ga naar pagina of 21
2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%, AK2000,AK6000,AK9800 )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE : $51,1* 725('8&(7+(5,6.
)MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS G 8VHDQH[WLQJXLVKHU21/ <LI < RXNQRZRXKDYHD&ODVV$%.
PRODUCT OVERVIEW WHIRLWIND SERIES HURRICANE SERIES CYCLONE SERIES 1 Model number: AK2000, 2036 QuattroVent Air Curtain Dual “Thrust-Fore" Self Clean Blowers Digital Touch Pad Controls Clock, Timer, 3 stage Delay Shutoff. Model number: AK9 8 00 Dual Self Clean Blowers Independent Rocker Controls w/ High, Low speed Slim Line Design Overview 1.
CONTROLS HURRICANE SERIES 2 Controls Overview 1. Set Time 2. Digital Display 3. Set Hours 4. Set Minutes 5. Set Timed Delay Shut Off 6. Light On-Off 7. Left Blower: On-High-Low-Off 8. Right Blower: On-High-Low-Off 9. Operations: On-Off 10. Right Blower Low Speed Indicator 11.
Blower Controls You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once. During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button.
CONTROLS 4 Setting Timer (Alarm) Press " hr " and " min " button to set desired timer countdown. Once timer is set, countdown will start in 7 seconds as delay indicator light flashes. When countdown reaches 0, 10 short beeps will sound.
MAINTENANCE 5 Self Clean Feature All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function.
Hurricane Series: Remove light shield by turning counter- clockwise. Clean in dishwasher under normal wash cycle. Whirlwind Series: Remove light shield by unscrewing Philips screw. Clean in dishwasher under normal wash cycle. Cleaning Tip: Fill residue containers ¼ full with water before cleaning or during regular use.
MAINTENANCE 7 QuattroVent Channels The QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly.
INST ALLA TION 8 REQUIREMENTS ACCESSORIES WARNING Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified background.
INST ALLA TION 9 MIN. 18” MAX 30” net width DUCT OPENING CLEARANCES Front Rear Front Rear Wall Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency.
INST ALLA TION 10 STEP 1 STEP 3 STEP 5 STEP 2 STEP 4 STEP 6 (also refer notes on pg. 16) 1. Remove all contents from box 2. Unscrew and remove bottom grease splash shield 1. Locate electrical connection box knock out from left rear of hood and pry open with screwdriver 1.
INST ALLA TION 11 STEP 7 STEP 9 (also refer notes on pg. 16) STEP 11 STEP 8 STEP 10 STEP 12 (also refer notes pg. 16) 1. Lift hood to bottom of cabinet 1. Support hood to place, fasten both rear with screws and washers provided. 1. Fasten front of hood.
INST ALLA TION 12 STEP 13 STEP 15 STEP 17 STEP 14 STEP 16 STEP 18 1. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. Turn on electrical supply or plug into receptacles. 1. Reinstall electrical box cover. 1. Next, fasten the 3 front screws and begin tightening all screws from rear to front.
INST ALLA TION 13 CONVERTIBLE OPTIONS 3-1/4 x 10“ Vertical Discharge 1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place. 3. Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws.
INST ALLA TION 14 3-1/4 x 10“ Rear Discharge 4. At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket. 6. Remove 2 arch blocks through top opening. Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket.
INST ALLA TION 15 3-1/4 x 10“ Rear Discharge Option 2: (for flush cabinet base) Mount rectangular transition piece at opening with gasket as shown. Mount rectangular cap (previously removed) on top of transition adaptor.
INST ALLA TION 16 INSTALLA TION NOTES Step 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call our service line to order.
TROUBLE SHOOTING 17 1. Upon completion of installation, nothing works. 2. Light is on but blowers are not turning at all or seems to be scraping on something. 3. When blowers are on, something seems to be loose and spinning around inside. 4. Vibration when blowers are on 5.
TROUBLE SHOOTING 18 11. Cooking fumes and smoke dissipates before it reaches the blower. Use a damper type sidewall cap. Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed and taped. Check if unit is installed at the recommended height (page 9).
www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of c harge, service lab or to repair any failed parts or components due to manufacturing defects.
Een belangrijk punt na aankoop van elk apparaat Zephyr AK6000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zephyr AK6000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zephyr AK6000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zephyr AK6000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zephyr AK6000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zephyr AK6000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zephyr AK6000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zephyr AK6000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.