Gebruiksaanwijzing /service van het product CPA-E48ASX van de fabrikant Zephyr
Ga naar pagina of 27
Use, Care, and Inst allation Guide Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ N.
2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local Electrical Inspector ’ s use. INST ALLER: Please leave these Instructions with this unit for the owner .
3 www .zephyronline.com T able of Content s Important Safety Notice .................................................................... 5 Electrical & Installation Requirements ............................................ 6 Electrical requirements .
4 Installation - Installing the Duct Covers ......................................... 18 Installation - Hanging the Hood onto the Wall .............................. 19 Installation - Electrical Connection & Final Installation Steps ..... 20 Electrical connection .
5 www .zephyronline.com Import ant Safety Notice CAUTION FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE T O EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR V APORS. W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
6 Electrical & Inst allation Requirement s ELECTRICAL REQUIREMENTS IMPORT ANT Observe all governing codes and ordinances. It is the customer’s responsibility: T o cont act a qualified electrical inst aller .
7 www .zephyronline.com List of Materials P ARTS SUPPLIED • Hood body , with st ainless steel baf fle filter a nd halogen light bulbs and incandescent lamp already inst alled • T wo telescopic duct covers and support bracket • Hardware Packet: - 24x53 T1T2 "L" Male monkey spanner (1 piece) - 3.
8 Dimensions and Clearances Only for version with top discharge feature: * Hood with external motor: Over this measurement a hole may be made on the rear section for the passage of the discharge pipe for connection to the external motor. Consult the template for the passage of pipes under this measurement .
9 www .zephyronline.com Ducting Options and Examples Closely follow the instructions set out in this manual. All responsibility , for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.
10 Inst allation - Ductwork Calculation Sheet 3 1/4 ” x 10” Rect., straight 6 ” Round,, straight 7", 8” Round,, straight 3 1/4 ” x 10” Rect.90° elbow 3 1/4 ” x 10” Rect.45° elbow 3 1/4 ” x 10” Rect.90° flat elbow 3 1/4 ” x 10” Rect.
11 www .zephyronline.com Inst allation - Preliminary Operations Attention! The installation requires several steps where is asked to temporarily remove some particulars and screws, We recommend to record and keep all of these components in a safe place ready to be used as required.
12 Inst allation - Internal Blower Note: for External blower installation disregard the instruction in this page and step ahead on page 14. TOP DISCHARGE (V ertical discharge) The hood is ready to be used for vertical discharge, proceed to install the internal blower (See next page).
13 www .zephyronline.com INTERNAL BLOWER INST ALLA TION • Fit the blower inside the hood. • Install the blower to the support with 4 screws (Provided), check that the rectangular outlet of the blower matches with the rectangular slot of the support.
14 • Install the supplied round transition collar to the previously installed cover/round transition support plate from inside the hood. Align and att ach with 2 screws securely .
15 www .zephyronline.com • Install the supplied round transition collar to the previously installed cover/round transition support plate. Align and att ach with 2 screws securely . EXTERNAL BLOWER ELECTRICAL CONNECTION - PRELIMINAR Y OPERA TIONS Installing the external blower junction box • Remove the electrical knock out on the upper panel.
16 • T o att ach front p anel to hood body , align the 8 threaded studs through the front bodies corresponding holes. Use 8 wing nuts to attach and secure. See diagrams below 2 3 1 4 6 5 8 7 1 2 3 4 5 6 7 8 3 4 Inst allation - Front Panel NOTE: The front p anel is not supplied with the range hood and must be purchased sep arately .
17 www .zephyronline.com Inst allation INST ALLING THE HOOD ONT O THE W ALL 1. Disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Use a thick, protective covering over countertop, cooktop or range to protect from damage and debris.
18 13. Optional duct cover installation: a. Remove the support bracket from the Duct Cover assembly and attach it to the ceiling with 2 drywall anchors and screws Note: The printed index on the bracket must match the center line previously drawn (See installation step 2 ).
19 www .zephyronline.com Inst allation - Hanging the Hood onto the W all 14. For internal blower inst allation ONL Y : a. Horizontal (Rear) discharge: Install from the outside the 3 1/4 ” x 10” Rect. transition on the outlet hole of the blower with 3 screws.
20 Inst allation - Electrical Connection & Final Inst allation S tep s 18. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off power circuit at the service p anel before wiring this unit. 120 V AC, 15 or 20 Amp circuit required.
21 www .zephyronline.com Description of the Hood 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover 6 2 2 3 3 4 1 5.
22 Features & Controls - T ouch Controls & Features Use the high suction speed in cases of concentrated kitchen vapors. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes after terminating cooking.
23 www .zephyronline.com Filter Clean Reminder (Standard Baffle Filters fitted): A set of baf fle filters are fitted by the factory . These Baf fle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
24 Maintenance BAFFLE FIL TER This must be cleaned once a month using non abrasi- ve detergent s, either by hand or in the dish-washer , which must be set to a low temperature and a short cycle. When washed in a dish-washer , the baf fle filter may discolor slightly , but this does not af fect it s filtering cap acity .
25 www .zephyronline.com Maintenance REPLACING THE MOOD LIGHTING BULB: T o replace mood lighting bulb, remove baf fle filter from hood. T o access lamp area, remove the two threaded knobs that fix the cover . Unscrew mood lighting bulb counter-clockwise and replace with a st andard max.
26 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal filter is vibrating. 1. The power source is not turned ON.
27 www .zephyronline.com List of Part s and Accessories Part Description Part# Internal Blower 600 CFM External Blower 1000 CFM Halogen Bulb, 120V 50 W Filter Baffle Z0B0020S EBI-600B CBE-1000 Front P.
Een belangrijk punt na aankoop van elk apparaat Zephyr CPA-E48ASX (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zephyr CPA-E48ASX heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zephyr CPA-E48ASX vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zephyr CPA-E48ASX leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zephyr CPA-E48ASX krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zephyr CPA-E48ASX bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zephyr CPA-E48ASX kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zephyr CPA-E48ASX . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.