T rapeze C TP-E 4 8SX C TP-E54SX C TP-E 6 0SX Model number: Serial number: U s e , C a r e , a n d I n s ta l la tion G u id e MAY07.0101 © Zep h yr Corpo ration.
www .zephyronline.com.
T able of Contents 1 SAFET Y NO TICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance .....
www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R ED U C E T H E R I S K O F F I R E O R E L E C TR IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L I D-S T ATE SP E E D CONTRO L DE V I C E . TO R E DUC E T H E R I S K O F F I R E, E L E C T R IC SH O C K, O R I NJ U R Y TO P E R S ON S, O B S E RVE T H E F O L LO W I N G: a.
Li s t o f M a t e r ia l s 3 MODEL: CTP-ExxS 1 - Hood 2 - Bae Filters 4 - G U-10, 120V 50 W , halogen bulbs 2 - Utensil Rails 2 - T elescopic Duct Covers 4 - T elescopic Rods Sets 4 - Angle Bra c .
www .zephyronline.com 4 I n s t a lla t io n - Duct wo rk C a lcula t io n S h e e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t . x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect.
5 I n s ta lla tion - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 9" 36" Min 98"-Max 124” Min 28"-Max 36" Min 34"-Max 52" Minimum mount height between range top to hood b ot- tom should be no less than 28".
www .zephyronline.com 6 I n s t a lla t io n - Du ct ing WARNING FIRE HAZARD N EV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork onl y .
15 3/4” 9“ “ 6 “ 9 ” 2 5 x a M - “ 4 3 n i M 26 5/8” 32” 48” , 54” , 59 1/8” Min 21” - Max 40” 12 1/8” 7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 2” 2” 7/6.
www .zephyronline.com I n s t a lla t io n - In t er n a l B l ow er 8 The internal blower kit consists of the blower and capacitor box with wiring. A TTE NTI O N The following are intructions for installing internal blower model CB I-600. F or instructions on preparing for external blower model CB E-1000 please turn to page “10” .
I n s t a lla t io n - In t er n a l B l ow er 9 6. Attach junction box to internal ange using provided 1/2” self tapping screws and 4mm internal diameter washers. 7 . Att ac h grounding wires from junction box and motor to grounding screw as shown.
www .zephyronline.com 10 I n s t a lla t io n - P re p a rin g H o o d fo r E xt e rn a l B lo we r The external blower kit consists of an 8” collar , external ange and external blower wiring box.
11 In s ta l l at i o n - M o unt i ng t he H o o d All Electrical work must by performed by qualied electrician or person with similar technical know how and bac kgr ound. F or personal saf ety , remove house fuse or open circuit breaker before beginning installation.
12 I n s t a lla t io n - M o u n ti n g th e H o o d 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle brac ket.
13 I n s t a lla t io n - M o u n ti n g th e H o o d 5. Lift assembled unit and atta ch all (4) angle bra ckets to ceiling bra cket. Make sure the tabs on eac h angle bra ckets are facing the outside. T he angle brackets will t between the slots on the ceiling bra cket.
I n s t a lla t io n - M o u n ti n g th e H o o d 14 Utensil Rail Installation 1. A ttach utensil rail to long side of hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post.
18 F ea t u r e s & C on t r ol s - T ou c h C on t r ol s & F e a t u r es The standard Bae Filters are required to be cleaned frequently and as recommended in order to maintain blower eciency .
16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
www .zephyronline.com 17 M a int e n a nce - C le aning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface.
18 Ma i n t e n an c e - Lights R eplacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T touch bulbs until switc hed o and cooled. T ouching hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot.
www .zephyronline.com T r ou b le S h oot in g 19 After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating.
20 www .zephyronline.com Halogen Bulb G U-10, 120V, 50W Z0B-0020 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00TP List of Parts and Accessories Par.
www.zephyronline.com Warranty One Y ear Service Repair W arr anty: F or one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects.
Een belangrijk punt na aankoop van elk apparaat Zephyr CTP-E 60SX (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zephyr CTP-E 60SX heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zephyr CTP-E 60SX vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zephyr CTP-E 60SX leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zephyr CTP-E 60SX krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zephyr CTP-E 60SX bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zephyr CTP-E 60SX kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zephyr CTP-E 60SX . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.