ww w .zeph yronline .com La y ers W all ALA - M90ABX ALA - M90A WX ALA - E42ABX ALA - E42A WX Edge W all AED - M90ASX Sur face W all ASU - M90ASX ASU - E42ASX Duo W all ADU - M90ASX RANGE HOOD - Insta.
ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 27 CAMP ANA EX TRA CTORA - Manual de utilización ...P ag. 53 CAPP A ASPIR ANTE - istruzioni per l’uso .
C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS .............................................................................................
ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUC TIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspec tors use . INST ALLER : Please leave these Instructions with this unit for the owner .
settings. B. Always turn hood ON when c ook ing at high heat or when ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or lter .
ww w .zeph yronline .com through the ue (chimney) of fuel burning equipment to prev ent back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those.
Models: ALA-M90ABX / ALA-M90A WX / ALA-E42ABX / ALA-E42A WX Duct Covers Electrical Junction Box Duct Cover Bracket Glass Light Bulbs Decorative Mesh F ilters Range Hood Body List of Materials TYPE DES.
ww w .zeph yronline .com Models: ASU-M90ASX / ASU-E42ASX Duct Cover Bracket Cont rol Duct Covers Blower Housing Range Hood Body Glass Electrical Junction Box Light Bulbs Decorative Mesh F ilters List .
Models: AED M90ASX Duct Cover Bracket Cont rol Duct Covers Light P anel Light Bulbs Decorative Mesh F ilters List of Materials Range Hood Body TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 1.
ww w .zeph yronline .com Model: ADU-M90ASX Light Bulbs Cont rol Decorative Mesh F ilters Range Hood Body Light P anel Blower Housing Electrical Junction Box Duct Cover Bracket Duct Covers List of Mate.
Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet. - 11 -.
ww w .zeph yronline .com front of hood side of hood top of hood Models: ALA-M90ABX / ALA-M90A WX / ALA-E42ABX / ALA-E42A WX Hood Speci cations - 12 -.
Models: ASU-M90ASX / ASU-E42ASX front of hood side of hood top of hood Hood Speci cations - 13 -.
ww w .zeph yronline .com Models: AED-M90ASX 35-3/8" 11-1/4" 12-1/16" 10-1/16" 19-11/16" W ood T rim Dimensions 5/8" Thick ness Hood Speci cations front of hood side of.
Models: ADU-M90ASX 35-3/8" 11-1/4" 12-1/16" 10-1/16" 19-11/16" W ood T rim Dimensions 1-5/8" Thick ness Hood Speci cations front of hood side of hood top of hood - 15 .
ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of re and electric shock, install this range - hood only with internal blow er models MT -020 provided with the kit cod CBI-600A.
6. Attach the 6 pin male molex connector from blo wer wire to the 6 pin f emale molex connec tor located inside the blower housing . See Fig .6 7. Install blower and blow er plate into blo wer housing by f ollowing the rev erse instruc tions from step 2 then use the screws pr ovided to complete installa- tion.
ww w .zeph yronline .com The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of re and electric shock, install this rangehood only with r emote blow ers ra ted maximum 6.
6. Inser t the 6 pin female molex connector into the junction box. See F ig . 6 A. Secure r emote blower junction box to top of blo wer housing using (2) screws . S ee F ig. 6B 7. F eed remote blo wer wir e harness through r emote blower junction box c ov er and Connect the wires with those inside the junction box.
ww w .zeph yronline .com W ARNING FIRE HA ZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only .
Installation - Moun ting the R ange Hood MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61cm) from the cooking sur face. If a connecting duct work composed of two par ts is used, the upper part must be placed outside the low er par t.
ww w .zeph yronline .com GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y CONNECTION F or connec tion to the po wer supply ref er to the follo wing: 1.
MOUNTING THE DUCT CO VER Models: ALA-M90ABX / ALA-M90A WX / ALA-E42ABX / ALA-E42A WX / AED- M90ASX / ADU-M90ASX 1. Install the elec trical wiring and test hood f or functions prior to installing the duc t co vers . 2. If using hood in air recirculating mode make sur e to install the air diverter plate prior to mounting the duct covers .
ww w .zeph yronline .com Models: ASU-M90ASX and ASU-E42ASX 1. Install the elec trical wiring and test hood f or functions prior to installing the duct covers . 2. If using hood in air recirculating mode make sur e to install the air diverter plate prior to mounting the duct cov ers.
Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the r egularity of maintenance.
ww w .zeph yronline .com List of P ar ts and A cc essories DESCRIPTION HOOD P ART# REPLA CEMENT P ARTS Light Bulb GU4, 20W (each) ALA, ASU Z0B0030 Light Bulb G4, 20W (each) ADU , AED Z0B0013 OPTIONAL .
3LIK0482.
Een belangrijk punt na aankoop van elk apparaat Zephyr Edge Wall AED - M90ASX (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zephyr Edge Wall AED - M90ASX heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zephyr Edge Wall AED - M90ASX vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zephyr Edge Wall AED - M90ASX leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zephyr Edge Wall AED - M90ASX krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zephyr Edge Wall AED - M90ASX bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zephyr Edge Wall AED - M90ASX kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zephyr Edge Wall AED - M90ASX . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.