Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: SEP07.0101 © Zephyr Corporation Roma Island ZRM-E36AS ZRM-E42AS.
www .zephyronline.com.
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance .
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a.
Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION 7 RUHGXFHULVNRI¿UHDQGWRSURSHUOH[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV attics, crawl spaces or garages.
List of Materials 4 www .zephyronline.com MODEL: ZRM-E36AS, ZRM-E42AS 2 Top Duct Covers 1 Top Support Frame 2 Bottom Duct Covers 1 Bottom Support Frame 2 Thin Trim Pieces 2 Thick Trim Pieces 1 Hood 4 Halogen Light Bulbs (pre-installed) 2 Metal Filters ( 3 - ZRM-E42AS) 3 Wire Nuts 4 ø14 OD / ø6.
5 Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 F t. x ( ) = Ft. 8” Round, straight 1 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 F t. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 F t. x ( ) = Ft.
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4 x 10” rectangular GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ HI¿FLHQF Always use rigid type metal ducts only .
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only .
8 www .zephyronline.com Installation – +RRG6SHFL¿FDWLRQV 3/4” 7 1/8 ” 10 3/4 ” 7 7/8 ” 10 1/8 ” 12 3/8 ” 8 3/4 ” FRONT 36” or 42” 27” 12” 14” 4” T op Support Frame (cei.
9 $GGDQGVHFXUHZRRGEORFNLQJ minimum 2 x 4 RQWRFHLOLQJMRLVWV 2. Fasten top support frame to desired location on ceiling using 4 2” wood screws with washers. The wider section of the support bracket faces the front of the hood.
10 www .zephyronline.com 7 8 10 9 11 Top Duct Covers Top Support Frame Bottom Duct Covers Bottom Support Frame Thin Trim Piece Thick Trim Piece $VVHPEOHWRSGXFWFRYHUV With louv.
11 Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood.
12 www .zephyronline.com Blower Off Lights On/Off Blower On/Speed Selection Blower Off Blower On/Speed Selection Lights On/Off The blower will be switched off by pressing: Switch blower on and select .
13 SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface.
14 www .zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot.
T roubleshooting 15 TROUBLESHOOTING PROCEDURES FOR ROMA Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly .
16 www .zephyronline.com DESCRIPTION P ART# Replacement Parts /LJKW%XOE05*8:HDFK =%6 0HWDO)LOWHUHDFK .
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to .
Een belangrijk punt na aankoop van elk apparaat Zephyr ZRM-E36AS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zephyr ZRM-E36AS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zephyr ZRM-E36AS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zephyr ZRM-E36AS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zephyr ZRM-E36AS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zephyr ZRM-E36AS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zephyr ZRM-E36AS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zephyr ZRM-E36AS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.