RS-1612 User ’ s Gu id e Version 1.0 JiH5< A CCESSING I NTERNET & I NTRANET.
ii Zy X EL Li m ite d Wa r r a nty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workmanship for a period of up to two (2) years from the date of purchase.
iii legal rights, and you may also have other rights which vary from state to state. Copyright © 1997 by ZyXEL The contents of this book may not be reproduced (in any part or as a whole) or transmitted in any form or by any means without the written permission of the publisher.
iv and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio/television rece.
v installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly. The customer should be aware that the compliance with the above conditions may not prevent degradation of service in some situations.
vi with ITU-TSS recommendation. This product complies with the following directives: 1. The Council Directive 89/336/EEC of 3 May 1992 on the approximation of the laws of the member states relation to Electro Magnetic Compatibility. (EMC Directive) 2.
vii • Technical support : support@zyxel.com in North America. support@zyxel.hinet.net outside North America. • Product information : Visit our site on the World Wide Web: http://www.zyxel.com. • FTP : Information , such as ZyXEL software and ROM updates for North America can be found at this FTP address: ftp.
viii Con te n t s ZyXEL Limited Warranty i i FCC Part 15 Information i i i Information for Canadian Users iv The declarations of CE marking: v Contacting ZyXEL vi 1 Introduction 1 What This Manual Cov.
ix Control Card 10 3 Installation 11 Setting up the RS-1612 Rack 11 Modem Card 11 Phone Lines 12 Connecting to Computers 12 Hooking Up Power 12 NMS Overview 13 Configuring the RS-1612 rack 13 Setting .
x.
1 Intr odu cti on Congratulations on your purchase of the RS-1612 series rack system, one of ZyXEL’s premier high performance products. The RS-1612 chassis is a 19-inch wide and 4U high metal frame modem chassis. Up to 16 U-336R/RE rack mountable modem cards run at speeds up to 33.
2 Other Resources For more information about the RS-1612 series rack system check the following sources: • U-336R/RE User's Guide The U-336R/RE User's Guide contains complete information about modems used in the RS-1612 rack.
3 • One Menu Tree Guide • One Warranty Registration Card.
4.
5 Prim a ry C om p onen ts Most operations you will perform with your RS-1612 rack system will involve the primary components. This chapter gives you an overview of the primary components and details on the use of their sub-components. Control Panel The control panel is to the right of the modem card slots.
6 LCD P a ne l The LCD panel shows the current operating status for the rack or various configuration menus. M e nu Key The Menu Key is used to choose which display or configuration menu appears on the LCD panel. Sometimes, the Menu Key doubles as an Up key for moving about in a particular display.
7 panel. For racks with redundant power supplies, turning both power supplies on ensures the rack remains energized if one power supply fails. Fuse The fuse protects the power supply card from an over current condition. The fuse for the AC power supply is a 250VAC 3A fuse.
8 Figure 2-2 RS-1612 Rear Panel D TE RS- 232 P o rt s The RS-1612 rack has sixteen DTE RS-232 ports. Each port corresponds to a modem card slot on the front. Connecting an RS- 232 cable between a modem port and a computer serial port allows two-way data transfer between the modem and the computer.
9 6 RX For use on four-wire leased line systems receiving line (R model only). 7 TX Transmits for four-wire leased lines, transmits and receives for two-wire leased lines (R model only). 8 TX Transmits for four-wire leased lines, transmits and receives for two-wire leased lines (R model only).
10 10B as e2, 10B as e5, 10B as e-T These connectors are used to connect the RS-1612 to a LAN. ZyView can manage the RS-1612 via the LAN. Only one of the three connectors can be used at any time. Control Card An internal control card is installed to monitor and control the modems.
11 Ins ta llat ion This chapter gives detailed instructions for installing one or more modems into the rack. Setting up the RS-1612 Rack Setting up the RS-1612 rack consists of plugging in modem cards, connecting phone lines, connecting to computers, and establishing power.
12 2. Holding both screw knobs, pull the card straight out. P hone Li ne s Sixteen terminal blocks correspond to the sixteen modem card slots in the rack.
13 2. Replace the control panel. 3. Make sure all other hardware installations are complete. 4. Switch the power source selector on the back panel to AC or DC according to the type of power supply(s) you are using. 5. Plug one end of the power cord into the socket on the back panel.
14 3. Power on the rack and wait until you see the Press ENTER to continue… prompt. 4. Press Enter and the following message is displayed: Enter Password: 5. Key in the default password 1234 , to enter into the CI command mode. 6. From the ras> prompt type: sys ether type and press Enter to view the current Ethernet interface setting.
15 or nms mask add <IP address> [mask] and press Enter . Mask, as given in this command, is a 16-bit value. Each bit corresponds to a modem slot. The most significant bit corresponds to slot 16, while the least significant bit corresponds to slot 1.
16 IP address configuration: Command Description sys ip <addr> [netMask] Defines IP address and subnet mask. sys ip gateway <addr> Defines default gateway. sys ip display Displays IP address. sys ip save Saves IP address. ip ping <addr> Pings a system.
17 Command Description <new passwd> sys password save Saves password. Change Baud rate of RS-232: Command Description sys baud x Changes and saves baud rate of RS-232 x 1: 38.
18.
19 Oper ation This chapter gives information on day to day use of the RS-1612 rack system. Most of what you will do with the rack involves configuring or setting modems or network administration. These topics are covered in detail in the U-336R/RE and ZyViewII User's Guides.
20 • Contrast Menu - The Contrast menu lets you adjust the contrast of the LCD display. • Modem Reset Menu - This menu allows you to reset the modem without interrupting power to the rack or unplugging the modem.
21 modem you are about to configure occupies, some key modem settings, major configuration categories, and the type of modem. Refer to the Menu Tree Guide for further details.
22 ZyXEL RS-1612 >> VER : 1.0 IP = 203.66.113.10 Figure 4-3 Main Display M e ssa ge D i sp l a y The message display shows brief messages sent by the supervisor to the rack. Pressing the Right Arrow Key from the Main Display accesses the Message Display.
23 << LCD CONTRAST >> 0 1 2 3 4 5 6 7 ^ Figure 4-5 Contrast Menu M ode m Re se t M e nu The Modem Reset Menu lets you reset the modem without interrupting power to the rack. To reset the modem: 1. From the Main Display press the Left Arrow Key .
24 Se tting the Di s pla y Contra st Changing the display contrast makes it easier to read the display. 1. From the Main Display, press the Right Arrow Key twice. 2. The Contrast Menu appears. Press the Left or Right Arrow Keys to set the contrast to the desired level.
25 1 stop bit 3. Turn on the RS-1612 rack to reboot the system. Type in any character to enter debug mode. 4. Change the data rate to 115200 bps using the atba5 command. 5. Type atur and press Enter to upload the firmware. 6. Wait for the following prompt characters: $$$ 7.
26 Se tting M ode m s w ith the Control P ane l Each modem card in the RS-1612 series chassis can be configured through the control panel. To access the modem control screens follow the steps listed below: 1. From the Main Display , press the Menu Key .
27 Changing Modem Cards When the rack is powered up, the control card reads each modem card's settings in the rack and stores the modem settings, It also stores all setting changes afterward. After changing a card the rack automatically recalls the previous settings and configures the new card accordingly.
Een belangrijk punt na aankoop van elk apparaat ZyXEL Communications RS-1612 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ZyXEL Communications RS-1612 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ZyXEL Communications RS-1612 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ZyXEL Communications RS-1612 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ZyXEL Communications RS-1612 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ZyXEL Communications RS-1612 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ZyXEL Communications RS-1612 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ZyXEL Communications RS-1612 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.