This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference.

1.1 Important notes 1. Do not operate unit without the air filter. 2. Do not operate unit near any heat source or open fire. 3. Do not expose the unit outside to direct sunlight and rain. 4. Always store or move the unit in an upright position. 5. Do not cover the appliance when in operation or immediately after use. 6. Always drain condensation before storing unit.



PLEASE NOTE: CHECK THE PLATE FOR THE TYPE OF REFRIGERANT GAS USED IN YOUR APPLIANCE.
Specific information regarding appliances with R290 refrigerant gas.

See transport regulations.
See local regulations.

See national regulations.
The storage of equipment should be in accordance with the manufacturer’s instructions.
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

competence to handle refrigerants safely in accordance with an industry recognised assessment specification. • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable refrigerants. • The working temperature range of the air conditioner is 16-35
oF) under cooling mode; 5-27
oF) under heating mode.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions may cause harm or damage. The seriousness is classified by the following indications:
Meanings of symbols used in this manual are shown below:
This symbol indicates never to do this.
This symbol indicates always do this.
2.2 Warning during usage
This symbol indicates the possibility of death or serious injury.
oC (60-95 · oC (41-80





Room air outlet 3
Carrying handle (both sides) 5


In the Cool Mode the appliance must be placed close to a window or opening so that the warm exhaust air can be ducted outside. First position unit on a flat floor and make sure there’s a minimum of 50cm clearance around the unit, and is within the vicinity of a single circuit outlet power source.


The hose can be extended from its original length of 38cm up to 150cm, but it is the best to keep the length to minimum required. Also make sure that the hose does not have any sharp bends or sags. (Fig. 6)
The adaptor A already be screwed to the hose for this unit.


1. Press the “mode” button until the Cool mode indicator is lit. 2. Press the “fan speed” button to choose the fan speed according to the illumination of the fan speed indicator. You can choose the fan speed as following sequence: “auto” → “hi” → “med” → “low” → “auto”. 3. Press the “ ” or “ ” button to choose the temperature you want. 1. ”t a e H “ e h t lit n u n o tt u b ” e d o m “ e h t s s e r P indicator is lit. 2. Press the “fan speed” button to choose the fan speed according to the illumination of the fan speed indicator. You can choose the fan speed as following sequence: “auto” → “hi” → “med” → “low” → “auto”. 3. Press the “ ” or “ ” button to choose the temperature you want. 4. Connected drain hose. See 7.4 Drainage section.
Some of the following instructions can only be used by using the Control Panel.
Heating mode (on some models)
In this mode the exhaust adaptor hose MUST be used.
It is not necessary to use the drainage hose in the “cool” mode.
Press the “mode” button until the Dry mode indicator is lit. The screen displays the room temperature. At the same time, the “low” fan indicator lights.
In this mode, there is no need to use the exhaust hose or drainage hose.
In this mode the exhaust adaptor hose MUST be used.
Dry mode · Fan mode · Cooling mode

and press the button again to quit the function. You can also cancel the setting by pressing the “on/off” button. After cancel the setting, the timer indicator will switch off.
How to delay shutdown You can delay shutdown when the unit is on. Press the “timer” button, then the Timer indicator will switch on and the number of hours on the screen will show “0.0”. Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay stop timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. Press the “timer” button again within 5 seconds, you will quit the timer setting directly. After 5 seconds, the timer function is enabled, the display will show the temperature back. The control will count down the time remaining until shuts down. To cancel the setting, press the “timer” button again will show the remaing time and press the button again to quit the function. You can also cancel the setting by pressing the “on/off” button. After cancel the setting, the timer indicator will switch off.
Always have the exhaust hose attached in this mode. When you set the air conditioner in Auto mode, it will automatically select cooling, heating (inapplicable for cooling only models), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. Under AUTO mode, you can not select the fan speed. 1. Press the “mode” button until the “Auto mode” indicator lights. After the “Auto mode” is selected the unit will run automatically according to the actual room air temperature.
The timer facilitates the user to delay the unit startup or shutdown.
Active this feature will give you a comfortable temperature and help save energy. Only when the unit is in Cool, Heat or auto mode, you can press the “sleep” button to make the unit run in Sleep mode. Note: Please refer to page 17 for the details about “Sleep” mode.
How to delay startup
Plug in the unit, so the unit turns to standby. Press the “timer” button, then the Timer indicator will switch on and the number of hours on the screen will show “0.0”. Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay start timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. Press the “timer” button again within 5 seconds, you will quit the timer setting directly. After 5 seconds, the timer function is enabled, the display will show the temperature back. The control will count down the time remaining until startup. The unit will start up in the mode as previously set. To cancel the setting, press the “timer” button again will show the remain time
Press the “swing” button to enable louver swing function, the louver on the top panel will swing up and down. Press this button again to disable the louver swing function.
Press the “ ” and “ ” button the same time for more than 3 seconds to switch between degree Fahrenheit and degrees Celsius. Under Dry/Fan mode, you can not select °F/°C.

Insert the provided batteries correctly (see the instructions inside the battery compartment). Close up the cover. To replace the old batteries (which have been used up) with two new R03P “AAA” 1.5V batteries, repeat the steps above.
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The filter indicator will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “filter reset” button, then the “filter” indicator will go off.


If the remote control unit is replaced or discarded, the batteries must be removed and disposed of in accordance with local legislation as they do harm to the environment. Do not mix old and new batteries. Do not mix alkaline, standard (carbon- zinc) or rechargeable (nickel-cadmium) batteries. Do not dispose of batteries in fire. Batteries may explode or leak. If the remote control is not used for a long time, remove the batteries from the remote control. The remote control must be handled with extreme care. Do not drop it or expose it to direct sunlight or sources of heat. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Point the remote control at the location of the signal receiver. The remote control must be no more than 16 ft (5 meters) away from the unit (without obstacles between the remote control and the unit).

Battery Installation and Important Instructions
Remove the cover at the back of the remote control.
Filter reset

How to Use the Remote Control
“high”, “mid” or “low” by pressing the Fan speed button and referring to the diagram. Note: In this mode, the air exhaust hose does not need to be connected.

Plug in the unit, then press the “on/off” button (when turned on, the unit will operate as the last setting before shutdown. To switch the unit off, press “on/off” button again, then remove the plug. Always switch the unit off by pressing the “on/off” button and wait for few minutes before removing the plug.
Press the “mode” button until the left side of LCD screen displays “cool”. Press the “fan speed” button to choose the fan speed “auto”, “high”, “mid”, and “low”. Press the “ ” and “ ” button to choose the temperature you want.
Heat mode (For Heat & Cool models only)
Press the “mode” button until the left side of LCD screen displays “heat”. Press the “fan speed” button to choose the fan speed “auto”, “high”, “mid”, and “low”. Press the “ ” and “ ” button to choose the temperature you want.

Press the “mode” button until the upper side of LCD screen displays “auto”. Under AUTO mode, you can not select the fan speed. Press the “ ” and “ ” button to choose the temperature you want.

Press the “mode” button until the left side of LCD screen displays “dry”. At the same time, the “low” fan symbol appears on the screen. Note: In this mode, fan speed cannot be selected.

When the unit is in Cool, Heat or auto mode, you can press the “sleep” button to make the unit run in Sleep mode. In this mode, the fan speed will be set as “auto” automatically, which cannot be changed. In Cool/Heat mode the selected temperature will increase/decrease by 1°C 30 minutes after the mode is selected. The temperature will then increase/decrease by another 1°C
Press the “mode” button until the left side of LCD screen displays “fan”. In this mode, you can select fan speed

after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the “Sleep” mode and the unit will shut down automatically. The “Sleep” mode program can be cancelled at any time during operation by pressing the “Sleep”, “mode” or “fan speed” button. Note: In Fan or Dry mode, Sleep mode cannot be set.
Press the “ ” and “ ” button the same time for more than 3 seconds to switch between degree Fahrenheit and degrees Celsius. Under Dry/Fan mode, you can not select °F/°C.
How to delay startup
Plug in the unit, so the unit turns to standby. Press the “timer” button, the screen will display “timer”and “h”, and the “on” will flashing. Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay start timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the setting will be memorized. The control will count down the time remaining until startup. You can also press the “timer” button again directly and the “on” will stop flashing immediately, then the unit will start up in the mode as previously set. You can set up the mode and the unit will start up as you preferred after “on” stop flashing. To cancel the setting, press the “timer” button again.

Press the “swing” button to enable louver swing function, and the upper side of screen will display “ ”. The louver on the top panel will swing up and down. Press this button again to disable the louver swing function.


How to delay shutdown
You can delay shutdown when the unit is on. Press the “timer” button, the screen will display “timer”and “h”, and the “off” will flashing. Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay stop timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. After 3 seconds, the setting will be memorized, and the display will show the time remaining until the unit shuts down.You can also press the “timer” button again directly and the “off” will stop flashing immediately.

Timer mode · Louver Swing Function · °F/°C function

7.4 Drainage instruction To cancel the setting, press the “timer” button again.

During the DRY mode or heat pump model, you will need a garden hose (sold separately) or drain hose to drain the condensate from the unit. Follow the steps below:

If the display reads “AS”, “CS” and “ES”, the temperature sensor has failed. Contact your Authorized AEG Service Center.
If the display reads “L3”, the condenser DC fan motor has failed. Contact your Authorized AEG Service Center.
If the display reads “P1”, bottom tray is full. Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Restart the machine until the “P1” symbol disappears. If error repeats, call for service.
If the display reads “E4”, the communication between display PCB and main control PCB is faulty. Contact your Authorized AEG Service Center.
Continuous Drainage

Replace the drain cap to the continuous drain outlet when no condensate flows out. Put the drip tray under the bottom drain outlet, then remove the rubber stopper from the drain outlet, to allow the condensate to flow into the drip tray. If your drip tray can’t hold all the condensate, a number of fills will be needed. Replace the drain cap to the bottom drain outlet when no condensate flows out.
%RWWRP 'UDLQ2XWOHW
'ULSFDS
)LJ
'ULSWUD\
Emptying the condensate residue inside the unit during winter storage.
Put a drip tray (not supplied) under bottom drain outlet, then pull out the drain cap to allow the condensate to flow into the drip tray.
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
Take out the upper air filter and the lower air filter.
The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
To keep your air conditioner working efficiently, you should clean the filters every two weeks of operation.

Before using the air conditioner again:
Be sure filter is thoroughly dry before replacing.
If the air conditioner will not be used for an extended period of time:
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Air from unit does not feel cold enough.
Air conditioner will not operate.
Air conditioner cooling, but room is too warm - NO ice forming on cooling coil behind decorative front.

Air conditioner cooling, but room is too warm - ice forming on cooling coil behind decorative front.
Air conditioner turns on and off rapidly.
Room too cold.
Recycle the materials with the symbol.
appliances. Do not dispose appliances marked with the symbol with the household waste. Return the product to your local recycling facility or contact your municipal office.
Put the packaging in applicable containers to recycle it. Help protect the environment and human health and to recycle waste of electrical and electronic