Thank you for choosing our product. We hope you will enjoy using the appliance.
Symbols in these Instructions for Use Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:
Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the warranty, the receipt and, if possible, the box with the in- ternal packing. If you give this device to other people, please also pass on the operating instructions.

Level I: low water pressure Level II: medium water pressure Level III: high water pressure
1 Single jet nozzle 2 Water stop switch 3 Handle 4 Water hose 5 Water pressure regulator 6 On/Off switch 7 Unit base 8 Water container 9 Handle for opening the lid / Handle for water container
Water stop switch (2) You can use this switch to momentarily interrupt the applica- tion. The shut-off is done mechanically. The pump of the device will continue to be in operation.
Nozzles (1) 4 nozzles with different color markings are contained in the scope of delivery. These can be assigned to different users.
When the gums are bleeding . . . It is normal for a normal bleeding to occur when using the oral irrigator the first few times. Should your gums bleed continually, please consult your dentist.
1. Remove the water container (8) from the unit base by the handle. Open it with the lever (9). 2. Fill the water container with water. Observe the marking MAX. Close the water container. Set it back onto the unit base. 3. Turn on the device with the On / Off switch (6). 4. Remove the handle (3) of the unit base. Hold the opening above a wash basin. 5. Switch the regulator (5) to level III. 6. Unlock the water stop switch (2) by sliding it to position I. 7. Let the water run directly into the wash basin to remove possible residues. Then lock the water stop switch by slid- ing it to the position 0. 8. Turn off the device. 9. Briefly rinse off the nozzles under running water.
Electrical connection 1. Check whether the mains voltage that you want to use matches the one of the device. You will find the informa- tion about it on the type plate. 2. Connect the mains cable to a properly installed ground- ed socket.
On / Off switch (6) Switch setting 0: The device is turned off Switch setting I: The device is turned on
Water pressure regulator (5) With the water pressure regulator, you can set three different power levels.
Your oralirrigator is now ready for use.

Noise development
Before using the water jet you should clean your teeth with a toothbrush.
The emisssion value referred to the place of work is below 70 dB (A).
1. Insert the nozzle onto the handle as far as possible. Turn the nozzle so that its opening points to the water stop switch. Ensure that the nozzle is fixed firmly in position. 2. Fill the water container with water which is hand warm. Do not fill it with hot water! 3. In order to clean the nozzles, allow water to flow through the nozzle head (at maximum water pressure) into the wash basin before and after each time the device is used. 4. Then use the water pressure regulator to select the desired water pressure. Begin on the smallest setting, es- pecially if you have problems with bleeding of the gums or when the water jet is used by children. 5. Unlock the water stop switch on the handle. 6. Lean over the wash basin. Guide the water jet along the gums, around the teeth. 7. Lock the water stop switch after the application. Set the water pressure regulator to level I. 8. Turn off the device. 9. Please clean the device as described under “Cleaning and Care”.
The noise that you perceive during use occur by the water flow. Operating noises
These noises are unavoidable due to the high performance,
but make no shortage represents.
Model: MD 5613 Power supply: 230 V~ ; 50 Hz Power consumption: max. 46 W Protection class: II (IPX 7) Net weight: 1.3 kg
The right to make technical and design modifications in the course of continuous product development remains reserved.
This device has been tested according to all relevant current CE guidelines, such as electromagnetic compatibility and low voltage directives, and has been constructed in accordance with the latest safety regulations.
Meaning of the “Dustbin” Symbol Protect our environment: do not dispose of electrical equip- ment in the domestic waste.
Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.
1. Pour out the remaining water from the water container. 2. Pull the nozzle off the handle. Clean the nozzles under warm running water. Dry the nozzles and place them onto the unit base. 3. If you have used water additives, rinse the water con- tainer with clear water. Then let ca. 300 ml clear water run through the device as described under “Initial opera- tion”. 4. Dry the handle before you place it back onto the unit base. 5. Dry off the water container. 6. Clean the unit base with a moist towel. Then wipe it dry.
This helps avoid the potential eff ects of incorrect dispsal on the environment and human health.
This will contribute to the recycling and other forms of reutili- sation of electrical and electronic equipment.
Information concerning where the equipment can be dis- posed of can be obtained from your local authority.