NL
AEG logo
Officiële handleiding

AEG MD 5613

42 pagina's·2.8 MB·Elektrische tandenborstel·PDF·ENJA
AEG MD 5613
Inhoudsopgave 15 secties English 22 · Instruction Manual · General Safety Instructions · Special safety instructions for this device · … TonenVerbergen
Page 1 of the AEG MD 5613 user manual — Special safety instructions for this device
Pagina 1 · klik om te vergroten
Pagina 1

English 22

Instruction Manual

  • Do not use it outdoors. Keep it away from sources of heat, direct sunlight, humidity (never dip it into any liquid) and sharp edges. Do not use the appliance with wet hands. If the appliance is humid or wet, unplug it immediately.
  • When cleaning or putting it away, switch off the appliance and always pull out the plug from the socket (pull the plug itself, not the lead) if the appliance is not being used and remove the attached accessories.
  • Do not operate the machine without supervision. If you leave the room you should always turn the device off. Remove the plug from the socket.
  • The device and the mains lead have to be checked regularly for signs of damage. If damage is found the device must not be used.
  • Do not try to repair the appliance on your own. Always contact an authorized technician. To avoid the exposure to danger, always have faulty cable be replaced only by the manufacturer, by our customer service or by qualified person and with a cable of the same type.
  • Use only original spare parts.
  • In order to ensure your children’s safety, please keep all packaging (plastic bags, boxes, polystyrene etc.) out of their reach.

Thank you for choosing our product. We hope you will enjoy using the appliance.

Symbols in these Instructions for Use Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:

General Safety Instructions

Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the warranty, the receipt and, if possible, the box with the in- ternal packing. If you give this device to other people, please also pass on the operating instructions.

  • The appliance is designed exclusively for private use and for the envisaged purpose. This appliance is not fit for commercial use.
  • Pay careful attention to the following “Special Safety Instructions”.

Special safety instructions for this device

  • WARNING:
  • This device can be used by children over the age of 8 and by persons with reduced physical, sensory or mental capabilities or lack of experience and/or knowledge if they are supervised.
  • Children may not play with the device.
  • The device may only be used with cold or lukewarm water.
  • Only use the device for the cleaning of the mouth.
  • Empty the water container after each application to prevent an accumulation of bacteria.
Page 2 of the AEG MD 5613 user manual — Application instructions
Pagina 2 · klik om te vergroten
Pagina 2

English 23

  • When using braces, find out whether the usage of an oral irrigator is possible. We do not assume any liability for possible damages.
  • In case of diseases in the mouth and throat area, you should ask your doctor whether the use of an oral irrigator is advisable.
  • Ensure that the water tube (connection of device and oral irrigator) is not stuck or kinked.

Overview of the control elements

Level I: low water pressure Level II: medium water pressure Level III: high water pressure

1 Single jet nozzle 2 Water stop switch 3 Handle 4 Water hose 5 Water pressure regulator 6 On/Off switch 7 Unit base 8 Water container 9 Handle for opening the lid / Handle for water container

Water stop switch (2) You can use this switch to momentarily interrupt the applica- tion. The shut-off is done mechanically. The pump of the device will continue to be in operation.

Position I of the switchWater is flowing Position 0 of the switch: Water is stopping

Nozzles (1) 4 nozzles with different color markings are contained in the scope of delivery. These can be assigned to different users.

Unpacking the Device

1. Take the device out of its packaging. 2. Remove all packaging materials, such as foils, filler material, cable brackets and cardboard packaging. 3. Check the scope of delivery.

When the gums are bleeding . . . It is normal for a normal bleeding to occur when using the oral irrigator the first few times. Should your gums bleed continually, please consult your dentist.

Initial operation

1. Remove the water container (8) from the unit base by the handle. Open it with the lever (9). 2. Fill the water container with water. Observe the marking MAX. Close the water container. Set it back onto the unit base. 3. Turn on the device with the On / Off switch (6). 4. Remove the handle (3) of the unit base. Hold the opening above a wash basin. 5. Switch the regulator (5) to level III. 6. Unlock the water stop switch (2) by sliding it to position I. 7. Let the water run directly into the wash basin to remove possible residues. Then lock the water stop switch by slid- ing it to the position 0. 8. Turn off the device. 9. Briefly rinse off the nozzles under running water.

Application instructions

Electrical connection 1. Check whether the mains voltage that you want to use matches the one of the device. You will find the informa- tion about it on the type plate. 2. Connect the mains cable to a properly installed ground- ed socket.

On / Off switch (6) Switch setting 0: The device is turned off Switch setting I: The device is turned on

Water pressure regulator (5) With the water pressure regulator, you can set three different power levels.

Your oralirrigator is now ready for use.

Page 3 of the AEG MD 5613 user manual — Disposal
Pagina 3 · klik om te vergroten
Pagina 3

English 24

Usage

Noise development

Before using the water jet you should clean your teeth with a toothbrush.

The emisssion value referred to the place of work is below 70 dB (A).

1. Insert the nozzle onto the handle as far as possible. Turn the nozzle so that its opening points to the water stop switch. Ensure that the nozzle is fixed firmly in position. 2. Fill the water container with water which is hand warm. Do not fill it with hot water! 3. In order to clean the nozzles, allow water to flow through the nozzle head (at maximum water pressure) into the wash basin before and after each time the device is used. 4. Then use the water pressure regulator to select the desired water pressure. Begin on the smallest setting, es- pecially if you have problems with bleeding of the gums or when the water jet is used by children. 5. Unlock the water stop switch on the handle. 6. Lean over the wash basin. Guide the water jet along the gums, around the teeth. 7. Lock the water stop switch after the application. Set the water pressure regulator to level I. 8. Turn off the device. 9. Please clean the device as described under “Cleaning and Care”.

The noise that you perceive during use occur by the water flow. Operating noises

These noises are unavoidable due to the high performance,

but make no shortage represents.

Technical Data

Model: MD 5613 Power supply: 230 V~ ; 50 Hz Power consumption: max. 46 W Protection class: II (IPX 7) Net weight: 1.3 kg

The right to make technical and design modifications in the course of continuous product development remains reserved.

This device has been tested according to all relevant current CE guidelines, such as electromagnetic compatibility and low voltage directives, and has been constructed in accordance with the latest safety regulations.

Cleaning and Care

  • WARNING:
  • Pull the mains plug from the socket before each cleaning.
  • Do not immerse the unit base and the mains plug in water.

Disposal

Meaning of the “Dustbin” Symbol Protect our environment: do not dispose of electrical equip- ment in the domestic waste.

  • CAUTION:
  • Do not use any wire brush or other abrasive objects.
  • Do not use any sharp or abrasive cleaners.

Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.

1. Pour out the remaining water from the water container. 2. Pull the nozzle off the handle. Clean the nozzles under warm running water. Dry the nozzles and place them onto the unit base. 3. If you have used water additives, rinse the water con- tainer with clear water. Then let ca. 300 ml clear water run through the device as described under “Initial opera- tion”. 4. Dry the handle before you place it back onto the unit base. 5. Dry off the water container. 6. Clean the unit base with a moist towel. Then wipe it dry.

This helps avoid the potential eff ects of incorrect dispsal on the environment and human health.

This will contribute to the recycling and other forms of reutili- sation of electrical and electronic equipment.

Information concerning where the equipment can be dis- posed of can be obtained from your local authority.

Vraag stellen over de AEG MD 5613

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de AEG MD 5613

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

AEG MD 5613 handleiding-pdf

42 pagina's·2.8 MB·Elektrische tandenborstel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…