Please read these instructions carefully before using the boiler. For Operating and Installation Instructions of boiler, please see separate instruction. These instructions are for the Alde Compact 3010 boiler fitted in vehi- cles, boats and buildings in accordance with CE no. 0845 BP0003, installation in vehicles e500 00005 and EMC e5 03 261.Installation and repairs may only be carried out by a professional. National regulations must be adhered to.


A green LED comes on beside the On-/Off button when the panel/boiler is on.
NB. if “Standby Brightness” is set to Off, the display goes out when it enters standby mode, but lights up if you press the screen. See settings under 9.12.
E F
A. Clock
E. LPG bottle full/empty
The clock shows day and time. The clock is set under section 9 point 2.
This symbol is displayed when the sensor on the cylinder changeover is connected and activated in accordance with section 9 point 8.

B. Outdoor temperature
The outdoor temperature is displayed only if an outdoor temperature sensor is fitted.
F. 230 volts
This symbol is displayed when 230V is connected to the boiler.
Fri 18.30
C. Indoor temperature
The indoor temperature is displayed automatically.
G. MENU button
Button for setting menu.
D. Circulation pump
H. On/Off button
This symbol is displayed when circula- tion of the central heating is called for.
Shut down / turn on the boiler.
3. From standby mode to setting menu When on standby, the indoor temperature is displayed, and the outdoor temperature is displayed if an outdoor tem- perature sensor has been connected. The background lights up when you press the screen or the MENU button. Start the setting menu by pressing the MENU button. The background lights up and those functions which can be set are displayed. The settings are automatically saved after 10 seconds. The control panel reverts to standby automatically after 30 seconds if no buttons are pressed (or if the MENU button in the setting menu is pressed).
NB. if “Standby Brightness” is set to Off, the display goes out when it enters standby mode, but lights up if you press the screen. See settings under 9.12.
Fri 18.30
2 kW · Off · On

If you wish to revert to the basic warm water settings before 30 minutes have expired.

OK
ON

Lan · Ext · Amp

*230 V This function is used in connection with starting the boiler when connection of 230 V to vehicle takes place from outside. When the 230 V function has been activa- ted the control panel’s on/off button must be turned off, but 12 V must be connected (the vehicle’s main switch is on). Before turning off the control panel with the on-/ off button set the parameters/functions that you want the boiler to have when it starts (230 V is connected).
16. *Load monitor This function is used to prevent the 230V fuses being overloaded. If the total power consumption of the vehicle, boat or build- ing exceeds the set value, the boiler’s power will be automatically reduced. On account of voltage variations and toler- ances, different setting levels can be selected (for example, for 6A fuse, one can choose 6 or 7 Amp setting). If the fuse does not hold, choose a lower set value. The function is deactivated in the factory setting. NOTE! The load monitor has to be installed for the function to be used (see the manual for the vehicle, boat or building).


Activated Functions · deact/act deact/act deact/act


Battery too low: If the vehicle, boat or building has a battery voltage of less than 10.5V, the boiler stops. It is automatically reset when the voltage reaches 11V.
Fan failure: Faulty fan speed. In order to reset, disconnect 12V from the boiler and reconnect (automatic reset after 5 minutes).
Gas failure: Gas finished. Reset by switching off and restarting the boiler in accordance with item 1.
Overheat red fail: Overheating protection (red cable) triggered. To reset, disconnect 12V from the boiler and reconnect.
Overheat blue fail: Overheating protection (blue cable) triggered. To reset, disconnect 12V from the boiler and reconnect.
Window open: Window open, the boiler stops for gas. Gas operation in the boiler starts again when the window is closed. The electrical opera- tion remains in function. Check the vehicle, boat or building manual to see whether this function is installed.
Connection failure: There is a connection fault between boiler and panel. To reset, disconnect 12V from the boiler and reconnect.
Connection fail ext: Communication error between Alde’s panel and external panel.
Panel failure 1: Panel fault.
Panel failure 2: Panel fault.
Art. No. 3010 218


panel Fuse 3,15 A (-) Fuse 3,15 A (+) 12 V DC 230 V pump 12 V pump
Gas failure · Control

INSTALLATION INSTRUCTIONS CONTROL PANEL 3010 613 Control panel 3010 613 is intended for the Alde Compact 3010 boiler.
The control panel should be located at least 1 metre above the floor, but not too close to the ceiling. Nor should it be enclosed, located on an outer wall or close to objects which radiate heat, for example, CD players, refrigerator and lamps, as this can give incorrect temperature. The area behind the panel should be well ventilated. If the room tem- perature on the panel is affected nevertheless, an external sensor should be connected to the panel. Make a hole for the panel as shown in figure C. Screw down the panel and push the front part on. Clip on the cables to avoid wear on the terminal strip of the panel.
C. B. A.

CABLE CONNECTION BETWEEN BOILER COMPACT 3010 AND CONTROL PANEL 3010 613 Connect accessories to the control panel as shown in the diagram below. N.B. Do not cramp 12 V cables or sensor cables together with 230 V cables. It is preferable not to place the cables close to each other. If the cables are bund- led, the risk of shutdown increases.
Back of control panel

Battery Back-up (3V DC) (H)
Heating of reduction valve (Eis Ex) (J)
Window breaker (I) · blue