OPERATING INSTRUCTIONS CONTROL PANEL 3010 613

Please read these instructions carefully before using the boiler. For Operating and Installation Instructions of boiler, please see separate instruction. These instructions are for the Alde Compact 3010 boiler fitted in vehi- cles, boats and buildings in accordance with CE no. 0845 BP0003, installation in vehicles e500 00005 and EMC e5 03 261.Installation and repairs may only be carried out by a professional. National regulations must be adhered to.

1. Starting the boiler

2. To start the boiler, press the On/Off button and the start-up display is displayed. The boiler starts with the last selected setting.
1. The control panel and the boiler are switched off.
Alde 3010 Control panel - Touch-Screen Colour 613 — 1. Starting the boiler diagram (page 1)
Afb. 1 · 1. Starting the boiler
Alde 3010 Control panel - Touch-Screen Colour 613 — 1. Starting the boiler diagram (page 1)
Afb. 2 · 1. Starting the boiler

A green LED comes on beside the On-/Off button when the panel/boiler is on.

2. The control panel in standby mode

NB. if “Standby Brightness” is set to Off, the display goes out when it enters standby mode, but lights up if you press the screen. See settings under 9.12.

D

E F

A. Clock

E. LPG bottle full/empty

The clock shows day and time. The clock is set under section 9 point 2.

This symbol is displayed when the sensor on the cylinder changeover is connected and activated in accordance with section 9 point 8.

Alde 3010 Control panel - Touch-Screen Colour 613 — D diagram (page 1)
Afb. 3

B. Outdoor temperature

The outdoor temperature is displayed only if an outdoor temperature sensor is fitted.

F. 230 volts

B

This symbol is displayed when 230V is connected to the boiler.

A

Fri 18.30

C. Indoor temperature

The indoor temperature is displayed automatically.

G. MENU button

Button for setting menu.

D. Circulation pump

H. On/Off button

H G

This symbol is displayed when circula- tion of the central heating is called for.

Shut down / turn on the boiler.

3. From standby mode to setting menu When on standby, the indoor temperature is displayed, and the outdoor temperature is displayed if an outdoor tem- perature sensor has been connected. The background lights up when you press the screen or the MENU button. Start the setting menu by pressing the MENU button. The background lights up and those functions which can be set are displayed. The settings are automatically saved after 10 seconds. The control panel reverts to standby automatically after 30 seconds if no buttons are pressed (or if the MENU button in the setting menu is pressed).

2. The control panel in setting menu. 1. The control panel in standby.

NB. if “Standby Brightness” is set to Off, the display goes out when it enters standby mode, but lights up if you press the screen. See settings under 9.12.

Fri 18.30

ON

2 kW · Off · On

Page 2 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — ON
Pagina 2 · klik om te vergroten
Pagina 2
4. Set the required temperature The temperature can be set from +5°C to +30°C in steps of 0.5°C. Warm water is always available (50°C) when the boiler is on and running on LPG and/or electricity. During summer, when only warm water is required, adjust the temperature setting to well below the surrounding temperature so that central heating circulation is not called for.
1. The temperature displayed is the temperature which is set at present (in this case 22.0°C).
2. Raise the temperature by pressing the + button. Lower the temperature by pressing the – button.

ON

3. The settings are ready and the central heating will circulate at the set temperature.
5. Hot water boost If you need more warm water, you can raise the water temperature temporarily from 50°C to 65°C. After 30 minutes, the boiler reverts to normal operation. While hot water boost is activated, the circulation pump is stopped.
1. Increase the quantity of warm water by pressing the + button. When activated the plus symbol changes colour to green.
2. The settings are ready.

ON

If you wish to revert to the basic warm water settings before 30 minutes have expired.

1. Reset the warm water by pressing the – button.
2. The settings are ready.

ON

Show 9 more labels / short text on this page
2 kW · Off · On · 2 kW · Off · On · 2 kW · Off · On
Page 3 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — ON
Pagina 3 · klik om te vergroten
Pagina 3
6. Heating with electricity Do as follows to active heating with electricity. The greater the power, the better the heating performance. In choosing between electricity and gas, electricity is given priority.
1. Start and step between the various power steps (Off, 1kW, 2kW or 3kW) with the + button or – button. The set value is displayed on the screen. When activated the plus symbol changes colour to green. (Certain boilers are equipped with max 2 kW, selecting 3kW is not possible in these cases.)
2. The settings are ready and the boiler is working at set temperature.
3. To switch off the electrical operation, step with the – button to Off.

ON

7. Heating with gas Do as follows to activate heating with gas. If both electricity and gas are selected, electricity is given priority.
1. Start the gas operation by pressing On. The On symbol is activated and changes colour to green.
2. The settings are ready and the boiler is working at set temperature.

ON

3. In order to switch off gas operation, press Off.
8. Unlocking the tool menu It is possible to go from the setting menu to the tool menu. Under the tool menu you can access the other functions of the control panel, described in section 9.
1. The control panel in setting menu. Press the unlock symbol.
2. The control panel in unlocking menu. Press on open padlock, then OK or MENU to unlock the tools menu. When activated the symbol changes colour to green.
3. The control panel in setting menu with unlocked tool menu. In order to get to the tool menu, press the symbol.

ON

OK

ON

Show 12 more labels / short text on this page
2 kW · Off · On · 2 kW · Off · On · 2 kW · 2 kW · Off · On · Off · On
Page 4 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — A
Pagina 4 · klik om te vergroten
Pagina 4
9. The tool menu - functions When you are in the tool menu (see section 8), you can use the tools described below. Step between the various tool fields by pressing the up or down arrow symbols. You can always leave the tool menu with the MENU button. NOTE! Functions marked with * indicate that the symbol for the function is displayed on the control panel even if the accessory is not installed!

A

1. Arrow symbols Step between the various tool fields by pressing the up or down arrow symbols. You can always leave the tool menu with the MENU button.
5. Constant pump operation Cont.: With this function selected the pump is permanently on. (NB., this function limits the supply of hot water, particularly when there is a low heating requirement) Therm: With this function selected the pump is controlled by the panel/room sensor. This is the normal operating mode for heating the vehicle and obtaining a normal supply of hot water. Factory setting is Therm.
2. Clock The clock must be set if automatic nighttime mode or automatic start is to be used. If 12V voltage is lost, the clock will be reset and correct time will no longer be displayed. This is prevented with an optional AA battery backup.
6. *Pump Auto / 12V In the Auto mode, the 230V pump operates, and when 230V is disconnected, the 12V pump starts. In 12V mode, the 12V pump is used even if 230V is connected. The Auto function is activated in the factory setting.

A

3. Automatic night-time mode This function is used when you want to programme the central heating to automatically lower the temperature at night and raise the temperature in the morning.
7. *Pump speed The circulation pump’s capacity can be remote controlled from the panel. NOTE! A pump with remote control must be installed in order that this function can be used (see the manual for the vehicle, boat or building).
4. Starting the boiler automatically This function is used to start the boiler automatically at a later point of time. With automatic start, the boiler works for 24 hours and then stops. After that, it repeats the automatic start once a week; at the same day and time, as long as the function is activated. For automatic start to function, the On/Off button must be set in the OFF position.
8. *LPG bottle full/empty This function is used in combination with the cylinder changeover (DuoComfort or DuoControl) and indicates if the LPG bottle is full or empty. This function can also be used to control defroster heating of the cylinder changeover using an EisEx defroster. NOTE! The cylinder changeover (DuoComfort or DuoControl) must be installed in order for this function to work (see the manual for the vehicle, boat or building).

Lan · Ext · Amp

Page 5 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — Ext
Pagina 5 · klik om te vergroten
Pagina 5
9. Automatic anti-bacterial mode (legionella) At 02.00 at night (if the clock is set) the boiler starts and works according to “Hot water boost” (see section 5). This is in order to reduce the risk of legionella. The function is deactivated in the factory setting.

*230 V This function is used in connection with starting the boiler when connection of 230 V to vehicle takes place from outside. When the 230 V function has been activa- ted the control panel’s on/off button must be turned off, but 12 V must be connected (the vehicle’s main switch is on). Before turning off the control panel with the on-/ off button set the parameters/functions that you want the boiler to have when it starts (230 V is connected).

10. Offset (temperature adjustment) Using this function, you can calibrate the temperature on the panel if you notice that the temperature (the stabilised room temperature) is not the same as the temperature shown on the panel. This also applies to outdoor temperature.

Amp

16. *Load monitor This function is used to prevent the 230V fuses being overloaded. If the total power consumption of the vehicle, boat or build- ing exceeds the set value, the boiler’s power will be automatically reduced. On account of voltage variations and toler- ances, different setting levels can be selected (for example, for 6A fuse, one can choose 6 or 7 Amp setting). If the fuse does not hold, choose a lower set value. The function is deactivated in the factory setting. NOTE! The load monitor has to be installed for the function to be used (see the manual for the vehicle, boat or building).

11. Button sound With this function, you can activate or deactivate the button sound. The button sound is activated in the factory setting.
12. Screen Brightness Brightness: The brightness of the display (working mode) can be adjusted from 1 to 10. Factory setting is 5. Standby brightness: Off: Used to turn the display’s backlighting off so that the display is turned off (becomes dark) in standby mode (the LED is still active). On: Used to activate the backlighting in the display (low lighting) in standby mode (the LED is still active). Factory setting is On.
13. Language This function is used to reset the screen between different languages. Available languages are: English, French and German. On the other hand, the service menu is only in English (see section 10.1).

Lan

14. Tools / Key Under Tools / Key you can lock or unlock access to the tool menu.

Ext

15. *External start This function is used when starting the boiler from the outside, for example, with GSM. When external start has been activated, the control panel’s On/Off button must be switched off (see the assembly setting manual for external start). NOTE! To use this function, an external start installation is required (see the manual for the vehicle, boat or building).
Page 6 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — RPM A
Pagina 6 · klik om te vergroten
Pagina 6

10. Service and Resetting the system

Alde 3010 Control panel - Touch-Screen Colour 613 — 10. Service and Resetting the system diagram (page 6)
Afb. 4 · 10. Service and Resetting the system
1. Service With this function, you can see certain values of the boiler on the screen. The values are updated once a second
3. Translator This function is used to enable an external main panel to operate the boiler. If a main panel is connected to the Alde panel, it is activated with the On button, otherwise it must always be set at Off. Factory setting is Off.
2. Resetting the system With this function the panel can be reset to factory setting. After resetting, the panel is set as follows: the boiler in Off mode, electrical operation 1kw, LPG heating in On mode and indoor temperature 22°C.Other functions are disconnected.
4. OK To leave the tool menu, press OK or Menu.

10:1 Service menus

Heater tempSanitary temp:
Fan rotationCurrent: Current: Overheat: Window switch: Extern start:

RPM A

Soft Rev. HeaterPanel: Cl Version:

Activated Functions · deact/act deact/act deact/act

Page 7 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — 10. Service and Resetting the system
Pagina 7 · klik om te vergroten
Pagina 7
11. Fault messages If an error occurs in the system, the display will show the reason. This is only displayed when the panel is on standby.
Alde 3010 Control panel - Touch-Screen Colour 613 — 10. Service and Resetting the system diagram (page 7)
Afb. 5 · 10. Service and Resetting the system

Battery too low: If the vehicle, boat or building has a battery voltage of less than 10.5V, the boiler stops. It is automatically reset when the voltage reaches 11V.

Fan failure: Faulty fan speed. In order to reset, disconnect 12V from the boiler and reconnect (automatic reset after 5 minutes).

Gas failure: Gas finished. Reset by switching off and restarting the boiler in accordance with item 1.

Overheat red fail: Overheating protection (red cable) triggered. To reset, disconnect 12V from the boiler and reconnect.

Overheat blue fail: Overheating protection (blue cable) triggered. To reset, disconnect 12V from the boiler and reconnect.

Window open: Window open, the boiler stops for gas. Gas operation in the boiler starts again when the window is closed. The electrical opera- tion remains in function. Check the vehicle, boat or building manual to see whether this function is installed.

Connection failure: There is a connection fault between boiler and panel. To reset, disconnect 12V from the boiler and reconnect.

Connection fail ext: Communication error between Alde’s panel and external panel.

Panel failure 1: Panel fault.

Panel failure 2: Panel fault.

  • 12. Emergency start
  • Disconnect the 12V cable and the cable to the panel on the boiler.
  • Connect a cable between 2 and 9 in the connector on the boiler.
  • Reconnect 12V to the boiler Now the boiler starts with gas and 1kW. Adjustment of the room temperature is not working. Constant pump operation is set.

Art. No. 3010 218

Alde 3010 Control panel - Touch-Screen Colour 613 — 10. Service and Resetting the system diagram (page 7)
Afb. 6 · 10. Service and Resetting the system
Alde 3010 Control panel - Touch-Screen Colour 613 — 10. Service and Resetting the system diagram (page 7)
Afb. 7 · 10. Service and Resetting the system

panel Fuse 3,15 A (-) Fuse 3,15 A (+) 12 V DC 230 V pump 12 V pump

Gas failure · Control

Page 8 of the Alde 3010 Control panel - Touch-Screen Colour 613 user manual — 76 mm
Pagina 8 · klik om te vergroten
Pagina 8

INSTALLATION INSTRUCTIONS CONTROL PANEL 3010 613 Control panel 3010 613 is intended for the Alde Compact 3010 boiler.

The control panel should be located at least 1 metre above the floor, but not too close to the ceiling. Nor should it be enclosed, located on an outer wall or close to objects which radiate heat, for example, CD players, refrigerator and lamps, as this can give incorrect temperature. The area behind the panel should be well ventilated. If the room tem- perature on the panel is affected nevertheless, an external sensor should be connected to the panel. Make a hole for the panel as shown in figure C. Screw down the panel and push the front part on. Clip on the cables to avoid wear on the terminal strip of the panel.

C. B. A.

76 mm

Alde 3010 Control panel - Touch-Screen Colour 613 — 76 mm diagram (page 8)
Afb. 8 · 76 mm

CABLE CONNECTION BETWEEN BOILER COMPACT 3010 AND CONTROL PANEL 3010 613 Connect accessories to the control panel as shown in the diagram below. N.B. Do not cramp 12 V cables or sensor cables together with 230 V cables. It is preferable not to place the cables close to each other. If the cables are bund- led, the risk of shutdown increases.

Back of control panel

Alde 3010 Control panel - Touch-Screen Colour 613 — 76 mm diagram (page 8)
Afb. 9 · 76 mm

Battery Back-up (3V DC) (H)

Heating of reduction valve (Eis Ex) (J)

Window breaker (I) · blue

Vraag stellen over de Alde 3010 Control panel - Touch-Screen Colour 613

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Alde 3010 Control panel - Touch-Screen Colour 613

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Alde 3010 Control panel - Touch-Screen Colour 613 handleiding-pdf

76 pagina's·23.5 MB·Verwarming·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…