The SA-300 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-300 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.


INSTALLATION INFORMATION: Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is not recommended for smoke detection. Then put the de- tector to the ceiling plate and, twist clockwise to lock it in place. It will emit a beep and be ready for use. Perform a first test by holding the key for three seconds. Also see the paragraph: “Testing”.

USING, TESTING AND MAINTENANCE: Using: The smoke detector works if the smoke detector has been mounted to the ceiling. A red LED will light up and the smoke detector will beep briefly to let you know that it has been activated, because the ceiling plate has switched a lever on the inside. The red LED will now flash every 40 seconds. Once smoke is detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop automatically.
Test: Hold the button for at least 3 seconds. The operation is still correct if you hear 2 or three signal tones. Check the smoke detectors weekly. In alarm status the smoke de- tector will generate about 85dB(A). Do not use candles, open fire or cigarettes to test the smoke detector.
Time-out function: This function will deactivate the alarm for about 5 minutes. This function can be enabled by pushing the HUSH/TEST button very shortly. The LED will now blink once every 8 seconds to indicate the deactivated smoke alarm. After 5 minutes, the alarm will be fully active once again. If there is (still) any smoke in the environment, the alarm will go off again. This function can be used repeatedly.

Maintenance: The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
REPLACING THE BATTERIES: The detector is supplied using a built-in lithium battery. Under normal conditions the battery will last at least ten years. If the detector is about to need replacement, the smoke detector will make a chirping sound every 40 seconds for at least 30 days. If the smoke detector does not function, please contact your supplier.
ENVIRONMENT: Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.
EU DECLARATION OF CONFORMITY: Hereby, Hesdo declares that the radio equipment type SA-300 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://DOC.hesdo.com/SA-300-DOC.pdf