The SA-19/1 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-19/1 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.


INSTALLATION INFORMATION: Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is not recommended for smoke detection. Put the 9V block battery in the smoke detector. Then put the detector to the ceiling plate and, twist clockwise to lock it in place. Perform a first test by holding the test key for two seconds. Also see the paragraph: “Testing”.
USING, TESTING AND MAINTENANCE: Using: The smoke detector works if the 9V battery has been placed and the SA-19/1 has been mounted to the ceiling. The unit can only be mounted to the plate if the battery has been installed. The LED underneath the test button will now flash ± every 45 se conds. Once smoke is detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop automatically
Time-out function: With this function the sensitivity of the alarm is reduced for about 10 minutes. This function can be switched on by pressing the “TEST/HUSH” button once. The sensitivity of the smoke detector is automatically reduced and the indicator light will briefly light up ± every 10 seconds to indicate that the sound is temporarily muted. The alarm is re activated after 10 minutes. If there is still smoke, the alarm sound will be heard again. This function can be used repeatedly.
Test: Hold the test key for at least 2 seconds. The operation is still correct if you hear 2 or three signal tones. Check the smoke detectors weekly. In alarm status the smoke de tector will generate about 85dB(A). Do not use candles, open fire or cigarettes to test the smoke detector.

Maintenance: The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
REPLACING THE BATTERIES: The detector is supplied using a 9Volt blok battery. Only use the recommended type Pairdeer 6F22. Under normal conditions the battery will last at least one year. If it is about to need replacement, the smoke detector will make a chirping sound every 30 to 40 seconds for at least 30 days. Pay attention to the polarity when replacing batteries. Test the detector after every battery replacement. If the smoke detector does not func tion, please contact your supplier.
ENVIRONMENT: Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.