NL
Animo logo
Officiële handleiding

Animo Alumo

44 pagina's·7.2 MB·Kachel·PDF·ENITJA
Animo Alumo
Inhoudsopgave 23 secties CONTENTS · GENERAL INFORMATION SAFETY INSTRUCTIONS AND WARNINGS · The packaging is designed · GENERAL INFORMATION · … TonenVerbergen
Page 2 of the Animo Alumo user manual — before installation!
Pagina 2 · klik om te vergroten
Pagina 2

GENERAL INFORMATION SAFETY INSTRUCTIONS AND WARNINGS

The packaging is designed

GENERAL INFORMATION

as a matter of principle to provide fully adequate protection against damage.

Be careful to ensure that the stone cladding is not damaged on unpacking. The material is easily scratched. Natural stone is not included in the gu- arantee.

of easily at your local community waste collection and recycling centre.

Use approved transport aids only with an adequate lifting capacity for transporting your heating device.

You should check the stove carefully, however,

Our tip: The wood used for packaging is not surface treated and you can thus burn it in your stove. The carton and PE sheeting can be disposed

after you have received it for any damage and to

be sure it is complete. If you have any complaints contact your stove specialist

dealer immediately.

SAFETY INSTRUCTIONS AND WARNINGS

Observe all national and European standards and all local regulations applicable

ONLY BURN APPROVED FUEL! The burning of readily combustible or explosive materials, such as e.g. empty spray cans, or storing these items in the vicinity of the stove is strictly pro- hibited because of the explosion risk. Your ANIMO® billet firewood stove may only be operated with a closed firebox door. Use only the tools supplied for opening the doors! The firebox door must be kept closed when not in operation.

ally the front wall of the heating device to heat up intensively. These should never be touched without appropriate protection. Warn other people, in par- ticular children, about this danger!

CAUTION WITH OBJECTS THAT ARE NOT HEAT RESISTANT! Placing any objects that are not heat resistant on or near the heating device is prohibited. Stands for drying laundry or similar items must be set up at an adequate distance from the device because of the acute fire risk! When your stove is in use for heating the processing of easily combustible and explosi- ve materials in the heated room or neighbouring rooms is prohibited.

for the operation of heating

appliances and contact your local chimney sweep

THE SURFACES OF THE BILLET FIREWOOD STO- VE HEAT UP VERY INTENSIVELY! Heat is released by the burning of fuel and this cau- ses the doors, the door handle and other operating handles, the door glass, the stovepipe and potenti-

before installation!

Animo Alumo — before installation! diagram (page 2)
Afb. 1 · before installation!
Page 3 of the Animo Alumo user manual — FLUE GAS VALUES
Pagina 3 · klik om te vergroten
Pagina 3
Animo Alumo — TECHNICAL DATA diagram (page 3)
Afb. 2

TECHNICAL DATA

with original angled pipe

DIMENSIONS

Body depth 475 mm

Weight without mantle 127 kg

Weight with steatite mantle 242 kg

Weight with sandstone mantle 216 kg

Stovepipe outlet diameter 130 mm

Nominal heat output to EN 13240 8 kW

Minimal heat output 4 kW

Room heating capacity in dependence on the building insulation 90-210 m³

Fuel throughput 2,2 kg/h

CO2 content 8,6 %

CO emission or 13% O 851 mg/Nm³

Dust emissions 19 mg/Nm³

FLUE GAS VALUES

Flue gas values for connection of the flue to DIN 4705, or in accordance with the chimney dimension to DIN 4705.

Flue gas mass flow rate 7,2 g/s

Flue gas temperature 180 °C

Minimum output pressure on a nominal heat output of 12 Pa

Height 1070 mm · Width 530 mm · Efficiency 85,7 %

Page 4 of the Animo Alumo user manual — SAFETY DISTANCES AND SAFETY MEASURES
Pagina 4 · klik om te vergroten
Pagina 4
Animo Alumo — SAFETY DISTANCES AND SAFETY MEASURES diagram (page 4)
Afb. 3

SAFETY DISTANCES AND SAFETY MEASURES

Minimum distance to non-combustible objects Y > 400 mm X > 100 mm

Minimum distance to combustible objects Y > 800 mm X > 200 mm

SAFETY DISTANCES AND SAFETY MEASURES

CHECK THE FLOOR LOAD-BEARING CAPACITY AND CONNECTIONS Make very sure before setting up that the floor structure is strong enough to bear the weight of the stove. Changes must not be made to the fireplace appliance. Apart from anything else this will result in a loss of your guarantee and warranty. Observe the appropriate installation instructions when ins- talling your stovepipe to the chimney if it is in the area of walls that have wooden panelling.

HOW TO AVOID FLUE GAS FORMATION AND WHAT TO DO IF IT DEVELOPS:

Watch the development of flue gas closely in dif- ficult weather conditions (atmospheric inversi- on) and check the draught conditions. Inadequate draught can cause smoke to blow back into the li- ving room or cause smoke to escape from the sys- tem. Damaging deposits can build up in the stove and in the chimney as a result.

BEWARE OF CONDENSATION Wet fuel material and operating the stove when it is too intensively damped down can lead to condensa- tion in the chimney, i.e. to the build-up of deposits of materials that are easily combustible, such as soot and tar and which could result in a chimney fire. Should this ever happen, call the fire department and bring everyone in the building to safety.

When smoke comes out of the oven let the fire go out and then check if all air inlets and smoke outlets are clear and clean. If in doubt call the chimney sweep.

Page 5 of the Animo Alumo user manual — ASSEMBLY
Pagina 5 · klik om te vergroten
Pagina 5

ASSEMBLY

The assembly must be carried out by authorised specialists only. The following points must be taken into account:

ASSEMBLY

Fresh air • Connection of a pipe to the intake (diameter: 125 mm, e.g.: Steel spiral – or HT pipe) fixed using pipe clamps (not provided in the scope of delivery!)

  • The air pipe and shutoff flap must be positioned close to the stove ( < 4 m and < 3 pipe bends)
  • Pipes leading from the outdoors must be provided with a windshield hood.
  • The intake pipe must be in gas-tight implementation (stick with heat-resistant silicon at the pipe junctions) observe the appropriate county regulations!

Depending on the version you use ANIMO® billet firewood stoves can be used independent of the ambient air. An air supply independent of the air in the room must be established, however, in these cases. Different country regulations must be complied with when this is done. Your chimney sweep or stove specialist dealer will provide you with the information you need.

The chimney provider must ensure that the com- bustion air resistance of the chimney is 2 Pa maximum even in the most difficult circumstances. Please observe all local rules and regulations.

It must be ensured for this stove that the chim- ney draught is at least equal to the specified value (10 Pa). If you have any problems with this contact your chimney sweep.

Page 6 of the Animo Alumo user manual — as low as possible!
Pagina 6 · klik om te vergroten
Pagina 6
Animo Alumo — Operation diagram (page 6)
Afb. 4 · Operation

Operation

Follow the heating guide below without fail in order to keep polluting emissions

OPERATION

When you first use your stove the special enamel coating is not yet fully hardened. It will only be ful- ly hardened after heating powerfully (!) several times. You should not touch the stove surfaces du- ring heating for this reason. The coating is harm- less, but you should air the room well after the first heating.

Placing fresh wood on a bed of glowing embers that has shrunk too small can result in excessive smoke development. The result: an explosive gas and air mixture forms. A new heating up process is recom- mended in this situation for safety reasons.

as low as possible!

ASH PAN The draw-out ash pan should be emptied regularly to prevent excessive heat stress to the grate. Hea- ting without using the ash pan results in the risk of over-heating and the loss of the guarantee. Caution: The ashes can contain red hot heat nests. For this reason the ashes should only be emptied into non- inflammable containers and the ash pan should ne- ver be put down on inflammable surfaces.

1. If the stove/chimney is cold, or during low pressure weather conditions burn some paper first.
2. Place about half a kg of softwood chips on some uncoated paper (not glossy paper) and 1 kg of firewood (3 small billets/logs) on top and turn the regulator button at the front fully to the right in the heating position.
3. Light the paper

SLIDE DAMPER CONTROL • Since the performance of your stove is also de- pendent on the chimney draught, the control knob on the rear wall must be used for adjus- ting to this on an individual basis.

4. As soon as the softwood chips are burning well turn the regulator to the middle position and a few minutes later turn it to the ideal setting (see the sketch above).
  • Use the heating position for heating or a couple of minutes after putting on some fresh wood!
5. After first lighting the fire (or after each additional start ) place about 1.6 kg of wood (2 logs) on the fire and parallel to this set the regulator at the front to the “heating position” again and leave it until the wood is burning well! Then continue as above.
  • Use the heat glove provided for operating the slide damper control.
  • Use the vibrating riddle grate with the riddle hook supplied to shake out the ash from the firebox into the ash pan.

The ash is a completely natural product and an outstandingly good fertiliser for all garden plants. It should first be stored and “quenched” with water.

  • The air regulator can be sealed 100 %. Complete closing of the air regulator (zero position on the slide damper control) during operation brings the risk of deflagration and is strictly prohibited.
Page 7 of the Animo Alumo user manual — MAINTENANCE AND CLEANING:
Pagina 7 · klik om te vergroten
Pagina 7

Fuel and fuel quantity maintenance and cleaning

Animo Alumo — Fuel and fuel quantity maintenance and cleaning diagram (page 7)
Afb. 5 · Fuel and fuel quantity maintenance and cleaning

The ANIMO® billet firewood stove is designed for the burning of dry billet wood. You can also heat with fuels such as wood briquettes. The right wood fuel provides long-lasting warmth and cosiness depending on the moisture content and the fuel quantity.

FUEL AND FUEL QUANTITY:

Different types of wood have different calorific va- lues. Deciduous wood is very well suited as a fuel, because it burns with a steady flame and a long sustained glow. Conifer softwoods burn faster and have a tendency to produce sparks.

  • IMPORTANT POINTS FOR CLEAN COMBUSTION:
  • Dry, untreated firewood
  • 14-18 % relative wood moisture
  • From 2-3 year, dry and well-ventilated storage
  • The correct firewood quantity and dimen sions (zuviel bewirkt Überheizen und schlechte Rauchgaswerte, zu wenig oder zu große Scheite bewirkt, dass die optimale Betriebstemperatur nicht erreicht wird)
  • 1.6 kg (2 wooden logs 25 cm in length or 2 wood briquettes) per fuel addition to the fire.

The burning of waste materials of all kinds (plastics, textiles, particle board, coal etc.) will damage to stove and the chimney and is also prohibited under law.

Alle Wartungs- und Reinigungsarbeiten sind ausschließlich bei vollständig ausgekühltem Ofen vorzunehmen.

MAINTENANCE AND CLEANING:

The ANIMO® billet firewood stove was designed for minimal maintenance and for a very long service life. Some cleaning activities and checking the seals will be necessary, however, from time to time. The periods between inspection intervals will depend on the quality of firewood used and also on the fre- quency of use.

CLEANING THE CONVECTION OPENINGS• Vacuum clean dust deposits regularly

Clean the stove thoroughly before the start of a new heating season.

  • CLEANING THE DOOR GLASS:
  • Use a special glass cleaner!
  • No caustic acids or solvents
  • Otherwise there is a risk of damaging the glass surface or the printing
  • Very sooty glass can result from moist firewood.
  • CLEANING THE FLUE GAS PIPES:
  • 1 x annually
  • To do this, remove the stovepipe
  • Brush/vacuum clean soot and dust deposits in the stove and the stovepipe
  • CLEANING THE STOVE SURFACES:
  • Clean extremely heat resistant stove surfaces with a (damp) cloth only!
  • Use original enamels only to repair any damage
  • Never clean the enamel before the first heating!

Check the seals on the firebox door and the ash pan before the start of the heating period and replace any seals that are damaged or worn!

Page 8 of the Animo Alumo user manual — Help
Pagina 8 · klik om te vergroten
Pagina 8

Help

The ceramic glass pane is becoming sooty too quickly

As a matter of principle: All stove glass windows will need to be cleaned with glass cleaner from time to time (depending on sue).

Poor draught Check with chimney sweep if draught is poor (the chimney height may need to be increased)

Wrong regulation When the regulation is wrong set the slide damper control without fail as in the Operator’s Manual (when the secondary air regulator is closed the glass window soots-up very quickly but when properly dealt with and operated the stove can burn itself clean)

Wrong regulation See“Fuel and fuel quantity” for dealing with wrong regulation

Damp wood See: “Fuel and fuel quantity” for dealing with damp wood if necessary wood briquettes should be used (these are evenly dried)

Stove does not draw properly Chimney draught is inadequate See: “Operation” (slide damper control)

Stove is sooted-up internally See“Maintenance and cleaning”

Fire in stove does not light properly

Influence of weather See“Operation”
Wrong fire lighting procedure See“Operation”

Stove smells and smokes into the room

Burning-in phase See“Operation” (hardening of the enamel coating)
Stove is dusty/dirty See”Maintenance and cleaning”

Enamel coating does not harden Burning-in phase has not been properly completed

See“Operation” (hardening of the enamel coating)

Smoke comes into the room when putting fresh wood on the fire and during the heating phase

Inadequate chimney draught, stovepipe connection is not properly sealed

Check to link points and seal again if necessary

If you are still unable to deal with your problem after going through this problem guide, contact your specialist dealer or chimney sweep.

Problem Reason Solution

Page 9 of the Animo Alumo user manual — SPARE PARTS LIST
Pagina 9 · klik om te vergroten
Pagina 9

SPARE PARTS LIST

Animo Alumo — SPARE PARTS LIST diagram (page 9)
Afb. 6
Page 10 of the Animo Alumo user manual — SPARE PARTS LIST
Pagina 10 · klik om te vergroten
Pagina 10

SPARE PARTS LIST

Animo Alumo — SPARE PARTS LIST diagram (page 10)
Afb. 7

65 RLS air control with air intake adapter 1000099

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
The ceramic glass pane is becoming sooty too quicklyAs a matter of principle: All stove glass windows will need to be cleaned with glass cleaner from time to time (depending on sue). p.8
The ceramic glass pane is becoming sooty too quicklyPoor draughtCheck with chimney sweep if draught is poor (the chimney height may need to be increased) p.8
The ceramic glass pane is becoming sooty too quicklyWrong regulationWhen the regulation is wrong set the slide damper control without fail as in the Operator’s Manual (when the secondary air regulator is closed the glass window soots-up very quickly but when properly dealt with and operated the stove can burn itself clean) p.8
The ceramic glass pane is becoming sooty too quicklyWrong regulationSee: “Fuel and fuel quantity” for dealing with wrong regulation p.8
The ceramic glass pane is becoming sooty too quicklyDamp woodSee: “Fuel and fuel quantity” for dealing with damp wood if necessary wood briquettes should be used (these are evenly dried) p.8
Stove does not draw properlyChimney draught is inadequateSee: “Operation” (slide damper control) p.8
Stove does not draw properlyStove is sooted-up internallySee: “Maintenance and cleaning” p.8
Fire in stove does not light properlyInfluence of weatherSee: “Operation” p.8
Fire in stove does not light properlyWrong frie lighting procedureSee: “Operation” p.8
Stove smells and smokes into the roomBurning-in phaseSee: “Operation” (hardening of the enamel coating) p.8
Stove smells and smokes into the roomStove is dusty/dirtySee: ”Maintenance and cleaning” p.8
Enamel coating does not hardenBurning-in phase has not been properly completedSee: “Operation” (hardening of the enamel coating) p.8
Smoke comes into the room when putting fresh wood on the frie and during the heating phaseInadequate chimney draught, stovepipe connection is not properly sealedCheck to link points and seal again if necessary p.8

Vraag stellen over de Animo Alumo

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Animo Alumo

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Animo Alumo handleiding-pdf

44 pagina's·7.2 MB·Kachel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…