INSTALLATION INSTRUCTIONS • ISTRUZIONI D’INSTALLAZIONE

  • NOTICE D’INSTALLATION
  • INSTALLATIONSANLEITUNGEN INSTRUCCIONES DE INSTALACION
  • INSTRUÇÕES DE INSTALAÇÃO

F

ODHGIES TOPOQETHSHS

D

E

AEI1G42EMX AEI1G50EMX

P

AEI1G50BB GR

Argo AEI1G50BB — F diagram (page 1)
Afb. 1

Split air conditioner system • Condizionatore d’aria split system

  • Climatiseurs split
  • Split-klimagerät Acondicionador de aire de consola partida sistema split
  • Aparelho de ar condicionado-Sistema Split

ΔΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΣΜΟΥ

37.4255.082.04 02/2017

Page 2 of the Argo AEI1G50BB user manual — WARNING
Pagina 2 · klik om te vergroten
Pagina 2

IMPORTANT! Please read before installation

  • Ground the unit following local electrical codes.
  • The Yellow/Green wire cannot be used for any connection different from the ground connection.
  • Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
  • Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.
  • Do not use multi-core cable when wiring the power supply and control lines. Use separate cables for each type of line.

This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently.

  • For safe installation and trouble-free operation, you must:
  • Carefully read this instruction booklet before beginning.
  • Follow each installation or repair step exactly as shown.
  • Observe all local, state and national electrical codes.
  • Pay close attention to all warning and caution notices given in this manual.
  • The unit must be supplied with a dedicated electrical line.

When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers.

WARNING

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

When installing In a ceiling or wall Make sure the ceiling/wall is strong enough to hold the unit-weight. It may be necessary to build a strong wooden or metal frame to provide added support.

... In a room Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors.

CAUTION

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

... In moist or uneven locations Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations.

If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.

... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... In a snowy area (for heat pump-type systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

  • When connecting refrigerant tubing
  • Keep all tubing runs as short as possible.
  • Use the flare method for connecting tubing.
  • Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them; screw by hand and then tighten the nut with a torque wrench for a leak-free connection.
  • Check carefully for leaks before starting the test run.

SPECIAL PRECAUTIONS

  • During installation, connect before the refrigerant system and then the wiring one; proceed in the reverse orden when removing the units.

WARNING

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.

  • When servicing
  • Turn the power OFF at the main power board before opening the unit to check or repair electrical parts and wiring.
  • Keep your fingers and clothing away from any moving parts.
  • Clean up the site after the work, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.
  • Ventilate the room during the installation or testing the refrigeration system; make sure that, after the installation, no gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heat-sources.
  • Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked, to ensure the grounding.
  • Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury and death .

When wiring

Page 3 of the Argo AEI1G50BB user manual — DELAYED FUSE
Pagina 3 · klik om te vergroten
Pagina 3
  • Installation site selection AVOID
  • Heat sources, exhaust fans.
  • Direct sunlight.
  • Damp, humid or uneven locations.
  • To make holes in areas where electrical wiring or conduits are located. DO
  • Choose places as cool as possible and well ventilated.
  • use lug bolts or equal to bolt down the unit, reducing vibration and noise.
Argo AEI1G50BB — SYSTEM WIRING DIAGRAM diagram (page 3)
Afb. 2

Provide a solid base for outdoor unit raised from the ground level. Fix unit to base using 4 anchor bolts.

SYSTEM WIRING DIAGRAM

Argo AEI1G50BB — SYSTEM WIRING DIAGRAM diagram (page 3)
Afb. 3

DELAYED FUSE

220 - 240 V ~ 50 Hz

Main switch for disconnection from the supply line must have a contact separation in all poles that provides full disconnection under category III overvoltage conditions.

EG 10 cm

Page 4 of the Argo AEI1G50BB user manual — TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
Pagina 4 · klik om te vergroten
Pagina 4

LENGTH, SIZE WIRES AND DELAYED FUSE

MODELL ("A") mL ("B") mL ("C") m mm21,50,751,510 A DUAL SPLIT15≤ 25≤ 25 MONO SPLIT15≤ 20≤ 20

Supply power wire A: Multipolar electric wire. Size and length of the suggested electric wire are showed on table “electrical data”. The wire must be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between the fixing point and the terminals allows the straining of the conductors L, N before that of the grounding.

Connecting wire B (SHIELDED): Bipolar electric shielded wire; size and length of the suggested electric wire are showed on table “electrical data”. The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).

Connecting wire C (with ground conductor): Multipolar electric wire; size and length of the suggested electric wire are showed on table “electrical data”. The wires have not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22).

ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

● Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene (min. thickness 8mm). MODEL (INDOOR UNIT)NARROW TUBELARGE TUBE OUTER DIAMETERMIN. THICKNESSOUTER DIAMETERMIN. THICKNESS A6,35 mm0,8 mm9,52 mm0,8 mm B - C6,35 mm0,8 mm12,7 mm0,8 mm
  • PVC pipe for condensate drain pipe (ø int.18mm) in length suitable to let the condensate flow into the outside drainage.
  • Anti-freeze oil for flare connections (about 30g.).
  • Electric wire: use insulated copper wires of size and length as shown at paragraph “SYSTEM WIRING DIAGRAMS”.

TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS

AT SHIPMENTADDITIONAL REFRIGERANT L Tot. (m)L n (m)L Tot. (m)L n (m) AEI1G42EMX AEI1G50EMX/BBMONO SPLIT12-20- DUAL SPLIT15123025

L Tot. = Total tubing length (L1 + L2 + L3...) Ln = Maximum tubing length of a single indoor unit (n=1,2,3...)

REQUIRED AMOUNT OF ADDITIONAL REFRIGERANT For tubing 1/4 “ - 3/8” = 15g/m For tubing 1/4 “ - 1/2” = 20g/m For tubing Emix (3/8”) = 15g/m

LIMIT OF ELEVATION DIFFERENCE - OUTDOOR UNIT/INDOOR UNIT: 10m (H1, H2, H3, H4,H5, H6) LIMIT OF ELEVATION DIFFERENCE BETWEEN INDOOR UNITS: 5m (H) No additional charge of compressor oil is necessary.

Page 5 of the Argo AEI1G50BB user manual — DECLARATION OF CONFORMITY
Pagina 5 · klik om te vergroten
Pagina 5

OPERATING LIMITS

Cooling Maximum conditions

Heating Maximum conditions

Outdoor temperature : 43°C D.B. Room temperature : 32°C D.B. / 23°C W.B.

Outdoor temperature : 24°C D.B. / 18°C W.B. Room temperature : 27°C D.B.

Cooling Minimum conditions

Heating Minimum conditions

Outdoor temperature : –15°C D.B. Room temperature : 10°C D.B. / 6°C W.B.

Outdoor temperature : –15°C D.B. Room temperature : 5°C D.B.

Outdoor - Indoor unit combination table

system typeoutdoor unitIndoor unit - circuit aIndoor unit - circuit b mono splitAEI1G42EMXA B mono splitAEI1G50EMX/BBB C dual splitAEI1G42EMXAA dual splitAEI1G50EMX/BBAA AB

A - B - C = indoor unit size (see catalogue)

Power Supply220 - 240 V ~ 50 Hz

Tools required for installation (not supplied) REGULATION (EU) No. 517/2014 - F-GAS

1.Standard screwdriver

19. Hammer

The unit contains R410A, a fluorinated greenhouse gas with a global warming potential (GWP) of 2087.50. Do not release R410A into the atmosphere.

2.Phillips head screwdriver

10. Drill

3.Knife or wire stripper

11. Tube cutter

4.Tape measure

12. Tube flaring tool

5.Level

13. Torque wrench
R410A1.30 kg / 2.71 Tonn.CO 2

6.Sabre saw or key hole saw

14. Adjustable wrench

7.Hacksaw

15. Reamer (for reburring)
8. Core bits ø 5
16. Hex. key

DECLARATION OF CONFORMITY

This product is marked as it satisfies Directives:

– Low voltage no. 2006/95/EC (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 +

A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011). – Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)

+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009), EN 61000-3-3 (2008) – RoHS2 no.2011/65/EU. – Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air

conditioners and fans. – Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air

conditioners. This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or operating instructions.

(go on page 6)

Vraag stellen over de Argo AEI1G50BB

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Argo AEI1G50BB

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Argo AEI1G50BB handleiding-pdf

44 pagina's·2.5 MB·Klimaatbeheersing diversen·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…