Atika ALE 800

82 pagina's·7.6 MB·Luchtbevochtiger/-ontvochtiger·PDF·ENJA
Atika ALE 800
Inhoudsopgave 29 secties EC Declaration of Conformity · Contents · Extent of delivery · After unpacking, check the contents of the box for · … TonenVerbergen
Page 2 of the Atika ALE 800 user manual — Residual risks
Pagina 2 · klik om te vergroten
Pagina 2

Symbols in the operating instructions

Safety advices

Before commissioning this product, read and keep to the following advice. Also observe the accident prevention rules of your professional association and the safety provisions applicable in the respective country, in order to protect yourself and others from possible injury. L Pass the safety instructions on to all persons who

Atika ALE 800 — Symbols in the operating instructions diagram (page 2)
Afb. 1 · Symbols in the operating instructions

Potential hazard or hazardous situation. Failure to observe these instructions may lead to injuries or cause damage to property. L

work with the machine. L Keep these safety instructions in a safe place. ƒ Make yourself familiar with the equipment before using it,

User information. This information helps you to use this machine optimally.

Assembly, operation and servicing. Here you are explained exactly what to do.

by reading and understanding the operating instructions. ƒ Only use this machine for the intended purpose for which it

is designed (see “Proper use”). ƒ Only start up this machine with the specified mains

Proper use

voltage. ƒ Within his area of work the operator is responsible for third

This air dehumidifier is only designed for indoor use to dry moist walls damage caused by water or to reduce the air humidity in confined spaces. The intended usage also includes compliance with the operating, servicing and repair conditions prescribed by the manufacturer and following the safety instructions included in the instructions. Follow the relevant accident prevention rules for operation and other generally recognised health and safety at work rules. Any other use is deemed not to be use as prescribed. The manufacturer is not liable for any type of damage resulting from this: the user bears the sole risk. Unauthorised modifications on the air dehumidifier exclude a liability of the manufacturer for damages of any kind resulting from it.

parties. ƒ The machine must not be operated by children or young

people under 16 years of age. They are not aware of the risks associated with the use of these devices. ƒ Keep children away from the device. ƒ Only operate the device with complete and correctly

attached safety equipment and do not alter anything on the device that could impair its safety. ƒ Do not switch on the device if it does not function properly

or was dropped causing damages to the cable or mains powr plug or if another part shows signs of damage. ƒ Only qualified persons are allowed to carry out repair work

on electrical equipment. The user of the device may be severly injured due to improper repair work. ƒ Switch off the device and disconnect the mains plug if you

do not use the device or before you transport or clean it. ƒ Switch off the device in case of faults, disconnect the

mains plug and contact the customer service. ƒ Never dip the device in water or another liquid. ƒ Do not place objects on the device. ƒ Keep foreign objects away from air inlet/outlet openings. ƒ Drain the water container before transporting the device to

Residual risks

Even if used properly, residual risks can exist even if the relevant safety regulations are complied with due to the design determined by the intended purpose.

prevent spills. ƒ Do not tilt the device, otherwise outflowing water may

Residual risks can be minimised if the “Safety advices” and the “Intended usage” as well as the whole of the operating instructions are observed.

cause damages to the air dehumidifier. ƒ Never pour or spray water on the device

Observing these instructions, and taking proper care, will reduce the risk of personal injury or damage to the equipment.

Electrical safety ƒ Use an extension cable in compliance with IEC 60245 (H

  • Risk from electricity when using improper electrical connections.
  • Touching live parts of opened electrical components.

07 RN-F) having a core cross-section of at least:

− 1.5 mm2 for cable lengths up to 25 m

− 2.5 mm2 for cable lengths over 25 m ƒ Long and thin connection lines result in a voltage drop. The

In addition, in spite of all the precautionary measures taken, non-obvious residual risks can still exist.

motor does not reach any longer its maximal power; the function of the device is reduced. ƒ Plugs and coupler outlets on connection cables must be

made of rubber, non-rigid PVC or other thermoplastic material of same mechanical stability or be covered with this material.

Page 3 of the Atika ALE 800 user manual — L Water vapours move easily and unhindered through the
Pagina 3 · klik om te vergroten
Pagina 3

ƒ When installing the power supply cable observe that it

Location of the air dehumidifier

does not interfere, is not squeezed, bended and the plug connection does not get wet. ƒ Wind off completely the cable when using a cable drum. ƒ Do not use the cable for purposes for which it is not meant.

Location If possible, the air dehumidifier should be placed in the middle of the room in order to have a good air circulation in the whole room. If this is not possible, locate the air dehumidifier so that air can be sucked and discharged unhindered. Keep a minimum distance of 10 cm to walls.

Protect the cable against heat, oil and sharp edges. Do not use the cable to pull the plug from the socket. ƒ Check the extension cable on a regular basis and replace

it if it is damaged. ƒ Do not use any defective connection cables. ƒ Do not set up any provisional electrical connections. ƒ Never bypass protective devices or deactivate them. ƒ Only hook up the machine by means of a fault-current

Place the air dehumidifier ⇒ horizontally to ensure that the condensed water can flow

circuit breaker (30 mA).

off unhindered ⇒ away from a heat source (e.g. a radiator). L Make sure that windows and doors of the room to be

The electrical connection or repairs to electrical parts of

the machine must be carried out by a certified electrician or one of our customer service points. Local regulations – especially regarding protective measures – must be observed.

dehumidified are closed. Electric supply

Repairs to other parts of the machine must be carried out

Compare the voltage listed on the device’s type plate, e.g. 230 V / 50 Hz, with the mains voltage and connect the air dehumidifier to a suited and and properly earthed electrical socket.

by the manufacturer or one of his customer service points.

Use only original spare. Accidents can arise for the user

through the use of other spare parts. The manufacturer is not liable for any damage or injury resulting from such action.

Use an electrical socket with a rated voltage of 230 V with a fault-current circuit breaker (30 mA). Power system fuse protection 10 A

Function principle

This air dehumidifier works on the basis of the condensation principle.

Start-up

Room air is sucked through a filter and a refrigerating element where water vapour in the air condense as water droplets. Then, the water droplets flow into a condensation water bowl and further into the water container while the dried cold air is piped through the condenser of the device, heated and blown again into the room. The temperature of the blown out air is approx. 2-5 °C above the room temperature. This increase of heat is caused by power introduced in the compressor and fan and by heat which is released by the condensation of the water vapour.

Before starting up Did you transport the air dehumidifier in horizontal position or at an angle large than 45°? L Allow the device to stand in vertical position for at least

one hour. L Notes 1. The air dehumidifier will not work if the set humidity value is higher than that of the environment. 2. Only use the air dehumidifier at a room temperature between 5 °C and 32 °C. The air dehumidifier will not function out of this range. 3. Do not operate the air dehumidifier in heavily dust-laden or chloric atmospheres. 4. Once the compressor has been started the fan motor and the compressor must run for at least 3 minutes during dehumidification. To prevent damages to the compressor, you should wait for 3 minutes after a shut-down of the air dehumidifier before you restart the device. 5. If the room temperature is under 10 °C and the relative humidity of the ambient air is rather low an operation of the air dehumidifier will not be necessary.

The relative humidity of air is gradually reduced thanks to continuous recirculation of the room air through the device resulting in a quick and gentle drying of the room.

L Water vapours move easily and unhindered through the

air. Therefore, it is essential to “seal” the room as tight as possible. That means doors and windows must kept closed and entering and leaving the room should be restricted if possible. Otherwise the drying efficiency of the device is considerably impaired.

Page 4 of the Atika ALE 800 user manual — Powering up
Pagina 4 · klik om te vergroten
Pagina 4

6. The device’s air dehumidification performance depends on room design, room temperature and relative humidity of the room air. 7. Drain the container when it is full. Then, reinsert the empty water container so that the device can work again. 8. Tranport this device only in upright (vertical) position. 9. If the device does not work or if the operation is suddenly interrupted for unknown reasons, ¨ see “Possible faults“. 10. When the air dehumidifier is in operation the compressor generates waste heat and the room temperature slightly increases. This is considered a normal process. Control panel

Powering up

button to switch on the power to the air dehumidifier. The display 2 ¨ “RH of air” indicates the factory-set humidity of air of 60 %. After 5 seconds the display indicates the actual humidity of air. The “RH” display indicates the humidity of air in a range between 30 % and 90 %. Shutting down

button again to switch off the power to the air dehumidifier. Setting the humidity value

Atika ALE 800 — Powering up diagram (page 4)
Afb. 2 · Powering up

(Reduce the RH setting) to set your desired relative humidity of air. If the set RH value is lower than 30 %, the device will continuously dehumidify and the indicator 2 displays “CO”. Hint: Normally, a relative humidity of air between 50 %

button (Increase the RH setting) or

and 60 % is sufficient to have a convenient indoor climate and to prevent condensation on structural components and furnishing. L If your desired RH value is lower than the actual RH by

1 ¨ ON/OFF button 2 ¨ Relative humidity (in %) or fault display 3 ¨ “Increase RH” button 4 ¨ Operating hour counter 5 ¨ “Reduce RH” button 6 ¨ Defrosting icon 7 ¨ “Fan ON” icon 8 ¨ “Water container full” icon 9 ¨ “Dehumidification mode” icon Continuous display = dehumidfication is running

3 %, the air dehumidifier will automatically start (compressor). The

icon (dehumidification) is continuously displayed. If your desired RH value exceeds the actual RH by 3 %, the air dehumidifier will automatically shut down (compressor). The

icon (dehumidification) is flashing. Automatic defroster At a room temperature under 20 °C not only condensation water is generated on the cold evaporator surface, but also ice. This ice blocks the heat exchanger so that the air flow is impeded. The built-in automatic defroster removes the ice from the evaporator. This allows a dehumidification operation down to a temperature of +5 °C.

(compressor and fan on) Flashing display = dehumidification is not running (compressor off - fan on) Fault code If the fault codes E3 – E4 – E5 are indicated in the “RH display” ¨ see “Possible faults”. Start-up L An acoustic signal will sound if you connect the power

icon is displayed on the display, the compressor continues to run, the fan is automatically stopped.

Once the defrosting process is finished the air dehumidifier returns to the dehumidification mode and the

icon turns off. Operating hour counter The air dehumidifier is equipped with an operating hour counter.

cable to an electrical socket. A fault has occurred when this acoustic signal does not sound. Check the power supply cable, the electrical socket and the fuse.

The number of hours during which the device was in operation in the past is displayed after the dehumidifier is turned on. The amount of time during which the device remains on will be added to the already elapsed time.

Show 4 more labels / short text on this page
Press the · Press the · Press the · During defrosting, the
Page 5 of the Atika ALE 800 user manual — Removing the water collecting container
Pagina 5 · klik om te vergroten
Pagina 5
4. Re-insert the container. When inserting put the draining hose (3) into the water collecting container. Make sure that the container is correctly positioned.

Water outlet

The water collecting container of the air dehumidifier is equipped with a float switch which turns off the device when the collecting container is full. L After 45 seconds, compressor and fan will automatically

Atika ALE 800 — Water outlet diagram (page 5)
Afb. 3 · Water outlet

icon and the fault code E4 will be displayed. Another acoustic signal will sound every 5 minutes if the water collecting container is not immediately emptied.

stop, and an acoustic signal will sound. The

Removing the water collecting container

1. Turn off the device. 2. Press on the hinged cover (1)
5. Close the hinged enclosure cover. 6. Restart the air dehumidifier. The

and open it then

Atika ALE 800 — Removing the water collecting container diagram (page 5)
Afb. 4 · Removing the water collecting container

icon and the fault code E4 should no longer be displayed. Icon and fault code are further displayed? Remove the container again and re-insert it properly. Continuous or extended operation In the case of a high humidity of air it is recommended to operate the air dehumidifier in continuous mode. In continuous mode it is not needed to empty the water collecting container.

Proceed as follows: 1. Remove the water collecting container from the device. 2. Put the draining hose (3) through the hole

in the enclosure and pull it out of the device on the other side

3. Remove the container (pos. 2) and empty is immediately.
Atika ALE 800 — Removing the water collecting container diagram (page 5)
Afb. 5 · Removing the water collecting container
Atika ALE 800 — Removing the water collecting container diagram (page 5)
Afb. 6 · Removing the water collecting container
3. Re-insert the collecting container in the device. 4. Close the hinged enclosure cover. 5. Place a large collecting container below the water draining. Or: Extend the water draining using a garden hose to pipe the water into a drain channel.
Page 6 of the Atika ALE 800 user manual — Cleaning and maintenance
Pagina 6 · klik om te vergroten
Pagina 6

L Pay attention to the following:

Removing the filter 1. Remove the enclosure door (4).

@ Make sure that the water can flow out

unhindered. @ Pipe the water preferably to a drain which is

Atika ALE 800 — @ Make sure that the water can flow out diagram (page 6)
Afb. 7 · @ Make sure that the water can flow out

positioned at a lower level. @ Make sure that the hose remains in its position,

is routed with a descending gradient, is not kinked or wound up.

Transport

Power off the device and disconnect the mains plug before each transport.

2. Pull out the three fixing bars (5)

Always transport the air dehumidifier in upright (vertical) position to prevent compressor damages. Hint: If you have transported the air dehumidifier in

. Remove the filter (6) from the enclosure door for cleaning

Atika ALE 800 — Transport diagram (page 6)
Afb. 8 · Transport

another than upright position (horizontal or tilted), allow the air dehumidifier to stand in upright position for at least one hour before starting it up.

Cleaning and maintenance

Turn off the device and disconnect the power plug before each cleaning and maintenance work. Maintenance and repair work other than those described in this chapter is only allowed to be carried out by service staff. Only use genuine spare parts. Other than genuine parts may result in unpredictable damages and injury. Cleaning Air filter A contaminated filter @ deteriorates the performance of the air dehumidifier, @ results to contamination inside the device. L Clean the filter in regular intervals depending on the

Slight contamination Use a vacuum or slightly knock off the filter to clean it. Bad contamination Carefully wash the filter in luke-warm soapy solution (max. 40 °C) and then allow it to dry well. Do not expose the filter to sunlight or other heat sources to dry it. Inserting the filter 1. Place the filter in the enclosure door and secure it using the three fixing bars. 2. Re-mount the enclosure door. Device cleaning Clean the device’s external surfaces using a wet cloth and a mild cleaning solution (soapy) on a regular basis. Make sure that no water enters the interior of the device. Do not use detergents or solvents for cleaning because such may attack parts of the device. Have the interior of the air dehumidifier inspected for contamination by service staff once in a year or more frequently depending on the operating conditions.

operating conditions.

Page 7 of the Atika ALE 800 user manual — Possible faults
Pagina 7 · klik om te vergroten
Pagina 7

Maintenance The air dehumidifier is designed for a trouble-free operation and a minimum of maintenance. All movable parts are permanently lubricated. Inside the device, there are no other parts to be maintained.

Storage

Store unused equipment in a dry, locked place out of the reach of children. Note the following to extend the service life of your air dehumidfier and to ensure a perfect function: @ Drain the water collecting container and dry it carefully. @ Clean the filter. @ Thoroughly clean the device. @ Check the air dehumidifier for perfect condition to ensure

a safe use of it after a longer period of storage. @ Carefully cover the air dehumidifier.

Possible faults

Power off the device and disconnect the mains plug before each troubleshooting.

Fault Possible cause Corrective action No power supply. Check fuses. Mains cable defective. Have it checked (electrician). Water collecting container full. Drain the water collecting container.

Motor does not start

Humidity of the room air lower than the set value.

Check the set humidity value and set another value if required. Room temperature or humidity of air out of the working range.

Only little condensation or no water

a) Check the room temperature (5 °C to 32 °C). b) Check the humidity of air (at least 30% RH). c) Check the set humidity value and set another

value if required. Air filter contaminated. Clean the air filter (see “Cleaning and Maintenance”). Air supply or exhaust air outlet blocked. Check. Place the device on another location of required (adhere to the minimum distance to walls (10 cm)). a) Interior of the device heavily

Contact the manufacturer or customer service.

contaminated. b) Refrigerant circuit defective.

Doors and/or windows open. Close doors and/or windows. a) Drain hose kinked or wound up. b) Not enough descending gradient.

Re-route the drain hose to allow the water to flow out unhindered. Device shuts down in continuous operation with drain hose

Water frozen in the hose. Take precautions to avoid water freezing.

Fault Possible cause Corrective action Water flows out of the device Leakage of the water collecting container.

a) Check the water collecting container. b) Replace the water collecting container. Device is placed on an uneven floor. Place the device on an even floor. Unusual noise or vibrations.

Screws, nuts or other parts loosened. Tighten the parts. If the parts cannot be tightened, are in the interior of the device or the noise persists: Contact the manufacturer or the responsible customer service respectively L Please contact the manufacturer or the customer service if you cannot eliminate a fault although you have carried out all

functional tests. L Immediately put the device out of operation if it does not function properly.

Page 8 of the Atika ALE 800 user manual — Technical specifications
Pagina 8 · klik om te vergroten
Pagina 8

Fault code Following fault codes can be indicated in the display 2 “Relative humidity of air”:

Fault code Fault E3 Humidity sensor defective. E4 Water collecting container full. E5 Refrigeration circuit sensor defective. L Please contact the manufacturer or customer service of the fault codes E3 or E5 appear.

Technical specifications

Type HT 600 HT 800 Model ALE 600 ALE 800 Air flow rate 680 m³/h 680 m³/h Rated power 1000 W 1200 W Rated current consumption 4.6 A 5.3 A Max. power 1200 W 1410 W Max. current consumption 5.4 A 6.4 A Power, fan 50 W 50 W Electrical power supply 230 V~ / 50 Hz 230 V~ / 50 Hz Power system fuse protection 10 A 10 A Temperature range 5 – 32 °C 5 – 32 °C Humidity of air range 30 – 90% rel. humidity of air 30 – 90% rel. humidity of air Dehumidification performance at 30 °C / 80% RH 60 l / 24 h 80 l / 24 h Degree of protection IP X0 IP X0 Freezing pressure 2.5 MPa 2.5 MPa Vapour pressure 1.0 MPa 1.0 MPa Refrigerant R 407 C R 407 C Refrigerant quantity 0.6 kg 0,78 kg Container volume, max. 5.8 l 5.8 l “Tank full” LED comes up at 3.9 l 3.9 l Room volume (at a ceiling height of 2.5 m) 150 – 200 m³ 250 – 300 m³ Room area 60 – 80 m² 100 – 120 m² Sound power level LWA < 70 dB (A) < 70 dB (A) Sound power pressure LPA 53 dB (A) 53 dB (A) Weight 51.5 kg 53.5 kg

Page 9 of the Atika ALE 800 user manual — Refrigerant circuit
Pagina 9 · klik om te vergroten
Pagina 9

Wiring diagram

Atika ALE 800 — Wiring diagram diagram (page 9)
Afb. 9 · Wiring diagram

Refrigerant circuit

Atika ALE 800 — Refrigerant circuit diagram (page 9)
Afb. 10 · Refrigerant circuit
Page 10 of the Atika ALE 800 user manual — Guarantee
Pagina 10 · klik om te vergroten
Pagina 10

Spare part list

Pos. Spare part

1 417659 Hinged cover 2 417610 Water collecting container with stopper and float switch 3 417660 Water draining hose 4 417661 Enclosure door 5 417655 Fixing bar 6 417656 Air filter 7 417657 Wheel 8 417658 Instruction label for control panel 9 417622 Float switch cpl. 10 417618 Safety label Always indicate the following when ordering spare parts: Air dehumidifier type, year of fabrication and spare part number.

Otherwise, no delivery is possible!

Atika ALE 800 — Spare part list diagram (page 10)
Afb. 11 · Spare part list

Guarantee

Please note the attached guarantee declaration.

Denomination · number

Vraag stellen over de Atika ALE 800

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Atika ALE 800

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Atika ALE 800 handleiding-pdf

82 pagina's·7.6 MB·Luchtbevochtiger/-ontvochtiger·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…