NL
ATIKA logo
Officiële handleiding

Atika ASP 4

70 pagina's·4 MB·Houtbewerking·PDF·ENITJA
Atika ASP 4
Inhoudsopgave 18 secties 230 V – 240 V · Extent of delivery · Symbols machine · After unpacking, check the contents of the box · … TonenVerbergen
Page 1 of the Atika ASP 4 user manual — Residual risks
Pagina 1 · klik om te vergroten
Pagina 1

Do not operate machine before having read the operating instructions, understood all the notes and assembly the machine as described here. Keep the instructions in a safe place for future use.

Contents Symbols machine / operating manual 9 Extent of delivery 9 Proper use 9 Residual risks 9 Safe working 10 Start-up 11 Working with the log splitter 11 Maintenance and care 13 Guarantee 14 Possible problems 15 Technical data 15 Declaration of Conformity 60 Spare parts 61

230 V – 240 V

Stop! Follow the operating instructions. Open the bleed screw Î Bleeding Page 12

Atika ASP 4 — 230 V – 240 V diagram (page 1)
Afb. 1

Extent of delivery

Symbols machine

After unpacking, check the contents of the box

Read the operating and safety instructions thoroughly before commissioning the machine.

! That it is complete ! Check for possible transport damage

Report any damage or missing items to your dealer, supplier or the manufacturer immediately. Complaints made at a later date will not be acknowledged.

Wear safety shoes when working with the machine to protect the feet from falling logs.

Wear safety gloves when working with the machine to protect the hands from chips and splinters.

Proper use ƒ The log splitter must only be used for splitting logs. ƒ Only straight-cut logs are suitable for use with the log

Wear safety goggles when working with the machine to protect the eyes from chips and splinters.

splitter. ƒ Metal parts (nails, wire etc.) must be removed from logs

before splitting. ƒ Every other form of use is considered improper use. The

Do not remove or modify any protection or safety devices.

manufacturer accepts no liability for any damages resulting from improper use, and any risk is in this case borne solely by the user.

Nobody else should be in the working area of the machine other than the operator. Keep other persons or animals out of the danger area (minimum distance 5 m).

Residual risks

Even if used properly, residual risks can exist even if the relevant safety regulations are complied with due to the design determined by the intended purpose.

Residual risks can be minimised if the “Safety information” and the “Intended usage” as well as the whole of the operating instructions are observed.

Page 2 of the Atika ASP 4 user manual — Electrical safety
Pagina 2 · klik om te vergroten
Pagina 2

Observing these instructions, and taking proper care, will reduce the risk of personal injury or damage to the equipment. ƒ Failure to observe the safety precautions can lead to injury

ƒ Do not overload the machine! You work better and safer in

the given performance range. ƒ Only operate the machine with complete and correctly

attached safety equipment and do not alter anything on the machine that could impair the safety. ƒ Faulty or damaged parts in the device must be replaced

to the operator or damage to property. ƒ Risk from electricity, by using non-standard electrical

immediately. ƒ Do not spray machine with water

connections. ƒ Touching live parts of opened electrical components. In addition, in spite of all the precautionary measures taken, non-obvious residual risks can still exist.

(this is hazardous due to live components). ƒ Do not leave the machine standing in the rain or use

when raining. ƒ Store the unused machine in a dry locked place away

from the reach of children. ƒ Switch the machine off and remove the mains plug from

Safe working

the socket when − carrying out repair works − carrying out servicing and repair works,

Before commissioning this product, read and keep to the following advice. Also observe the preventive regulations of your professional association and the safety provisions applicable in the respective country, in order to protect yourself and others from possible injury. L

removal of faults − Transporting − leaving unattended (even during short interruptions) ƒ Check the machine for possible damage

− Before continuing to use the machine, the protective

Pass the safety instructions on to all persons who work with the machine. L Keep these safety instructions in a safe place.

devices must be inspected to ensure that they work perfectly and with their intended function

− Check whether the parts are damaged. All parts must

be correctly installed and fulfil all conditions to ensure perfect operation of the saw

ƒ Make yourself familiar with the equipment before using it,

− Damaged guards and parts must be properly repaired

by reading and understanding the operating instructions. ƒ Do not use the machine for unsuitable purposes (see

or exchanged by a recognized, specialist workshop; insofar as nothing else is stated in the instructions for use.

“Normal intended use” and “Working with the log splitter”). ƒ Ensure that you have stand in a secure standing

− Damaged or illegible safety warning labels should be

position and maintain your balance at all times. ƒ You should take up a working position behind the ram in

replaced immediately.

the area of the operating handles. Never stand in the area of the splitting wedge. ƒ Never stand on top of the machine. ƒ Pay attention at all times. Take care with what you are

Electrical safety

ƒ Electrical connections must conform to IEC 60245 (H 07

RN-F) with a cable cross-section of at least ⇒ 2.5 mm² for a maximum cable length of up to 10 m ƒ Never use the machine with a power supply cable of over

doing, and approach the work sensibly. Do not use the machine: − when you are tired. − under the influence of drugs, alcohol or medications

10 m in length. Longer power supply cables will cause a drop in voltage. The motor will not be able to provide its maximum performance and the operation of the machine will be impaired. ƒ When laying the connecting attachments, be sure that

that may impair your powers of judgement. ƒ When working with the machine, always wear

− protective goggles or face mask − safety gloves − hearing protection − safety shoes with steel toe-caps ƒ Wear suitable work clothing:

they do get crushed or bent, and that the plug-and-socket connection does not get wet. ƒ Do not use the cable for purposes for which it is not

meant. Protect the cable against heat, oil and sharp edges. Do not use the cable to pull the plug from the socket. ƒ Regularly check the extension cables and replace them if

− do not wear any loose-fitting clothing or jewellery,

since these may be caught or trapped by moving parts ƒ Within his area of work the operator is responsible for

third parties. ƒ The machine may not be operated by children or young

they are damaged. ƒ Do not use any defective connection cables. ƒ When working outdoors, only use extension cables

people under the age of 18. ƒ Keep children away form machine. ƒ Never operate the machine if other persons are in the

especially approved and appropriately labelled for outdoor use. ƒ Do not set up any provisional electrical connections. ƒ Never bypass protective devices or deactivate them.

immediate vicinity. ƒ Never leave the saw unattended. ƒ Keep your workplace in an orderly condition!

Untidiness can result in accidents.

Page 3 of the Atika ASP 4 user manual — Working with the log splitter
Pagina 3 · klik om te vergroten
Pagina 3

The electrical connection or repairs to electrical parts

ƒ Never try to split logs containing nails, wire or other similar

of the machine must be carried out by a certified electrician or one of our customer service points. Local regulations – especially regarding protective measures – must be observed.

objects. ƒ Already split wood and wood chips create a dangerous

working area. The operator may stumble, slip or fall. Always keep the working area neat and tidy. ƒ Never place the hands on or near any moving parts of the

Repairs to other parts of the machine must be carried

machine when it is switched on. Maintain a safe distance from the log, the ram ƒ and the wedge in order to protect your hands from injury. ƒ The machine should only be used for splitting logs with a

out by the manufacturer or one of his customer service points.

Use only original spare parts, accessories and special

accessory parts. Accidents can arise for the user through the use of other spare parts. The manufacturer is not liable for any damage or injury resulting from such action.

maximum length of 370 mm.

Positioning Position the log splitter on a work surface at a height of about 60 – 75 cm, this will create an comfortable working position.

Start-up ƒ Check that the machine is completely and correctly

Place chocks under the wheels to prevent the machine rolling during operation.

Ensure that the working area meets the following conditions:

assembled. ƒ Before using the shredder, make sure each time that

− no danger of slipping − level − free of obstacles − sufficiently well lit

− there are no faulty connections (tears, cuts, etc.)

− there are no damage at the machine

− all screws are tight

− check the hydraulic system for any possible leaks L Mains connection ƒ Compare the voltage given on the machine model plate

Do not operate the machine in the direct vicinity of gas or petrol pipes or containers, or any other easily inflammable materials. What type of logs can I split?

e.g. 230 V with the mains voltage and connect the machine to the relevant and properly earthed plug. ƒ Only use connection cables with sufficient diameters. ƒ Connect the machine via a 30 mA fault current safety

Size of logs Length: max. 370 mm Diameter: 50 – 250 mm The log diameter is a recommended guideline figure, because: − thin logs can be difficult to split if they contain knots or if

switch. L Fuse protection: 16 A L Hydraulics ƒ Never operate the machine in the event of any possible

the fibres are too strong. − logs with a diameter of over 250 mm can be split if the

fibres are smooth and open. Do not try to split green logs. Dry logs are much easier to split, and do not cause jams as often as green (damp) wood.

free of oil. Danger of slippage or fire! ƒ Check the hydraulic reservoir regularly to ensure that it

contains enough hydraulic oil (see “Care and maintenance”) Capacity: 2.6 litres

Operation

Two-hand operation 1. Press the ON/OFF switch on the electric motor. Wait a few moments until the motor has reached its operating revolutions and the required pressure has been built up in the hydraulic pump – Fig. 1. 2. Press both operating handles down simultaneously – Fig. 2. Î The log ram pushes the log against the splitting wedge, and the log will be split. 3. Release the operating handles. The log ram will now return to its original starting position – Fig. 3.

Working with the log splitter

additional SAFETY INSTRUCTIONS ƒ The log splitter may only be operated by a single person. ƒ The machine may only be operated by persons over the

age of 18 years, and who have read and understood these operating instructions. ƒ Wear protective equipment (safety goggles/mask, gloves,

safety shoes) to protect yourself from possible injury.

Page 4 of the Atika ASP 4 user manual —  Special instructions for splitting logs:
Pagina 4 · klik om te vergroten
Pagina 4

ON/OFF switch

Bleed screw

Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 2 · ON/OFF switch
ƒ Splitting logs¾ Always place the logs lengthwise and flat on the main
Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 3 · ON/OFF switch
Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 4 · ON/OFF switch

frame of the log splitter. The log must be enclosed by the log guide plates. Fig. 5

Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 5 · ON/OFF switch
Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 6 · ON/OFF switch

¾ Never place the log on the frame at an angle. Fig. 6

Atika ASP 4 — ON/OFF switch diagram (page 4)
Afb. 7 · ON/OFF switch

Special instructions for splitting logs:

¾ Always ensure that the splitting wedge and the log ram

contact the ends of the log at right-angles. ¾ Never try to split two logs at once. ¾ Never try to remove or replace the log during the splitting

ƒ Preparations: The logs to be split should be cut to the maximum dimensions (370 mm long, ∅ 50 – 250 mm). Ensure also that the logs are cut straight and square. Place the log properly on the log splitter, so as not to cause any risk of stumbling or falling to the operator.

process. L Never try to force the splitting of the log by maintaining the pressure for several seconds. This can lead to damage to the machine. Reposition the log on the main frame and repeat the splitting process, or put the log to one side. How to release a jammed log? 1. Release both operating handles so that the log ram can return to its starting position.

Bleeding Open the bleed screw 3 – 4 complete turns – Fig. 4. Close the bleed screw again when you are finished splitting logs.

open · tighten

Page 5 of the Atika ASP 4 user manual — J
Pagina 5 · klik om te vergroten
Pagina 5
2. Place a triangular wooden chock under the log, then move the log ram forward so that it pushes the chock under the jammed log. 3. If the log is not released, keep repeating this procedure, using larger chocks, until the log is released.

Care and maintenance Remove the plug from the power socket before starting any maintenance or cleaning work.

Never use a hammer to release a jammed log, and keep your hands away from the log. Do not enlist the aid of a second person - this is a one-man job. Do not try to release the log by using a hammer, since this may break the motor block.

Wear protective gloves in order to avoid injury to the hands. L Observe the following in order to keep the log splitter in

good working orderƒ Clean the machine thoroughly after you have
ƒ Finishing work¾ Before switching off the machine at the ON/OFF switch on

finished using it. ƒ Remove any resin remains on the machine. ƒ Oil the piston rod (Fig. 7) regularly with an

the electric motor, ensure that the log ram has been allowed to return to its starting position. ¾ Then remove the plug from the power socket. ¾ Close the bleed screw. Fig. 4 ¾ Follow the care and maintenance instructions.

environmentally friendly spray oil. ƒ Check the oil level and change the oil as necessary. Sharpening the splitting wedge After extended periods of use, or if the splitting performance is reduced, sharpen the splitting wedge with a file (and remove any burrs). Fig. 9

Atika ASP 4 — Sharpen wedge diagram (page 5)
Afb. 8 · Sharpen wedge

A

B

Atika ASP 4 — A diagram (page 5)
Afb. 9

Sharpen wedge

D

G

F

E

Atika ASP 4 — Sharpen wedge diagram (page 5)
Afb. 10 · Sharpen wedge

H I

How do I check the oil level? 1. The log ram must be in its starting position. 2. Stand the log splitter on end, with the filler opening at the top. Fig 10

A second person will be required to up-end and hold the log splitter. 3. Unscrew the dipstick – Fig. 11. Do not drop or lose the oil seal when removing the dipstick. 4. Clean the dipstick and the oil seal. 5. Replace the dipstick fully into the oil reservoir. 6. Now remove the dipstick again, and read off the oil level. If the oil level is between the two marking on the dipstick, there is sufficient oil in the reservoir. If the oil level is below the lower marking, more oil should be added with the aid of a clean funnel.

J

A Log ram F Electric motor B Bleed screw G ON/OFF switch C Piston rod H Splitting wedge D Dipstick I Log guide plates E Cylinder cover J Operating handles

lower marking upper marking

Atika ASP 4 — J diagram (page 5)
Afb. 11
Page 6 of the Atika ASP 4 user manual — When should I change the oil?
Pagina 6 · klik om te vergroten
Pagina 6
7. Check the oil seal and replace it if it is damaged in any way.
4. Now tip the machine to empty the oil into the container. 5. Stand the log splitter on end, with the filler opening at the top. Fig 10.

A second person will be required to up-end and hold the log splitter. 6. Pour in the new hydraulic oil (2.6 litres) using a clean funnel. 7. Clean the dipstick and the oil seal. 8. Check the oil seal and replace it if it is damaged in any way. 9. Replace the dipstick and screw it firmly into place. Caution! Do not tighten the screw too tightly, since this may damage the oil seal or the thread in the cylinder cover. Dispose of the old oil properly (local oil disposal point). The old oil must not be poured into the ground or drainage system, or mixed with other waste. L Hydraulic oil We recommend the following hydraulic oils for the hydraulic cylinder:

8. Replace the dipstick and screw it firmly into place. Caution! Do not tighten the screw too tightly, since this may damage the oil seal or the thread in the cylinder cover.
Atika ASP 4 — Guarantee diagram (page 6)
Afb. 12 · Guarantee

¾ Shell Tellus T 22 ¾ Aral Vitam Gf 22 ¾ BP Energol HLP 22 ¾ Mobil DTE 11 ¾ or equivalent Do not use any other types of oil. The use of any other type of oil will adversely affect the operation of the hydraulic cylinder.

Atika ASP 4 — Guarantee diagram (page 6)
Afb. 13 · Guarantee

Guarantee

  • The machine is guaranteed for a period of 2 years from the date of purchase/delivery against faults due to material or manufacturing errors.
  • The guarantee is rendered invalid in the event of any damage caused due to improper use or handling, improper packaging when returning the machine or failure to observe the operating instructions.
  • Faulty parts must be returned to our works carriage-paid. The decision on free replacement of faulty parts will be made at our discretion.

When should I change the oil?

  • The guarantee does not cover normal wear and tear to the splitting wedge, hydraulic oil, guide plates, seals or wheels.

The first oil change should be carried out after 50 operating hours, and then every 250 operating hours or 1x per year. Changing the oil: 1. The log ram must be in its starting position. 2. Place a container under the log splitter to catch the old oil. The container should have a capacity of at least 4 litres. 3. Unscrew the dipstick. Do not drop or lose the oil seal when removing the dipstick.

  • Any guarantee work will be carried out by the manufacturer. Our express approval must be obtained before having any such work carried out by another company.
  • The guarantee only remains valid provided that original replacement parts are used.
  • We reserve the right to make technical changes in the course of technical progress.

Oil seal · Dipstick

Page 7 of the Atika ASP 4 user manual — Guarantee
Pagina 7 · klik om te vergroten
Pagina 7

Possible problems Problem possible cause remedy Logs are not being split properly (insufficient splitting performance)

⇒ The log is not positioned correctly ⇒ The log exceeds the maximum dimensions or the wood is too hard for the performance of the machine ⇒ The splitting wedge is not working

⇒ Reposition the log correctly ⇒ Cut the log to the required dimensions ⇒ Sharpen the splitting wedge, and check

properly ⇒ Oil leak ⇒ Hydraulic pressure too low ⇒ Incorrect connecting lead (longer than

for any burrs or notches ⇒ Place a sheet of cardboard under the

log splitter in order to locate the leak. To correct the problem, refer to the manufacturer or other approved service centre. ⇒ Check the oil level and add more oil if

necessary. If the problem cannot be rectified, refer to the manufacturer or other approved service centre. ⇒ Use the correct connecting lead

10 m or too small cable cross-section)

Log ram travels out jerkily or under heavy vibration

⇒ Air in the circuit ⇒ Open the bleed screw ⇒ Check the oil level and add more oil if

necessary. If the problem cannot be rectified, refer to the manufacturer or other approved service centre. Log ram will not move out ⇒ Hydraulic pump defective ⇒ To correct the problem, refer to the

manufacturer or other approved service centre. Motor will not start ⇒ No electrical power ⇒ Connection cable defective ⇒ Electric motor defective

⇒ Check the fuse (16 A). ⇒ Replace the connection cable or have

it checked by an electrician. ⇒ To correct the problem, refer to the

manufacturer or other approved service centre. Oil leak at the dipstick ⇒ Oil seal at the dipstick not sealing ⇒ Replace the oil seal.

Technical data Splitting force 40 kN (4 t) Log length 370 mm Log diameter 50 – 250 mm Stroke 300 mm Piston rod diameter 30 mm Hydraulic oil (max.) 2.6 litres Electric motor performance (power consumption) P1 = 1500 W ( S1-100 % ) Power supply 230 V ~ 50 Hz Revolutions 2850 rpm Dimensions Length 1115 x Width 320 x Height 470 mm Weight 45 kg

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Logs are not being split properly (insufficient splitting performance)⇒ The log is not positioned correctly ⇒ The log exceeds the maximum dimensions or the wood is too hard for the performance of the machine ⇒ The splitting wedge is not working properly ⇒ Oil leak ⇒ Hydraulic pressure too low ⇒ Incorrect connecting lead (longer than 10 m or too small cable cross-section)⇒ Reposition the log correctly ⇒ Cut the log to the required dimensions ⇒ Sharpen the splitting wedge, and check for any burrs or notches ⇒ Place a sheet of cardboard under the log splitter in order to locate the leak. To correct the problem, refer to the manufacturer or other approved service centre. ⇒ Check the oil level and add more oil if necessary. If the problem cannot be rectified, refer to the manufacturer or other approved service centre. ⇒ Use the correct connecting lead p.7
Log ram travels out jerkily or under heavy vibration⇒ Air in the circuit⇒ Open the bleed screw ⇒ Check the oil level and add more oil if necessary. If the problem cannot be rectified, refer to the manufacturer or other approved service centre. p.7
Log ram will not move out⇒ Hydraulic pump defective⇒ To correct the problem, refer to the manufacturer or other approved service centre. p.7
Motor will not start⇒ No electrical power ⇒ Connection cable defective ⇒ Electric motor defective⇒ Check the fuse (16 A). ⇒ Replace the connection cable or have it checked by an electrician. ⇒ To correct the problem, refer to the manufacturer or other approved service centre. p.7
Oil leak at the dipstick⇒ Oil seal at the dipstick not sealing⇒ Replace the oil seal. p.7

Vraag stellen over de Atika ASP 4

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Atika ASP 4

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Atika ASP 4 handleiding-pdf

70 pagina's·4 MB·Houtbewerking·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…