Vertical, floor-standing water heater with a
ceramic element and an "impressed current anode”

Thermal insulation (injected polyurethane
Internal enamel coated protection
D.C. generator
Ceramic element, enamel plated sheath and housing
Handles are built into both ends to facilitate handling. Several attachment types are possible depending on the nature of the wall : A) Thin walls (plasterboard partition). ø 10 mm threaded rods passing through the wall connected by sections or plywood panels. B) Thick hard walls (concrete, stone, brick) Grout in ø 10 mm bolts or drill holes to fit ø 10 mm MOLY type inserts. C) Vertical wall-mounted water heaters may be placed on a tripod when the partition can- not support the weight of the heater. An additional upper stirrup attachment is compulsory. Use the tripod recommended by the manufacturer.
Use the attachment template printed on the packaging box for both types of walls
and check the centre distance of the holes.



HM on the floor

except for 75 l

Water connections must be made to the water heater in accordance with standards and regu- lations in force in the country in which it will be installed (for France, use D.T.U. 60.1).

CONNECTION DIAGRAM EXAMPLE OF A VERTICAL WALL-MOUNTED WATER HEATER
Cast iron or steel coupling or insulating fitting
Safety unit to be operated twice/month
cold water network
This safety unit includes: 1 stop valve 1 manual drain valve 1 non-return valve (to pre- vent water in the water hea- ter from flowing back into the cold water network) 1 safety valve set to 7 bars 1 non-return valve inspection plug Hot water

bars.
Pressure reducer if P > 5 bars on the main water inlet
pressure reducer
that will be located
on the water inlet
inlet Siphon with funnel end and air trap Drain pipe
after the meter.
Our heaters are in conformity with stan- dards in force and consequently have all necessary safety features. The electrical connection shall comply with installation standard (France) NF C 15-100 and recom- mendations in force in the country in which the water heater will be installed (Certifying Label, etc.).
The electronic generator for water heaters with "impressed current anode" has been designed
for a permanent power supply or of the type operating in off-peak hours, 8 h or 6 h + 2 h.
Make sure that the installation respects one of these two power supply options,
the guarantee conditions will not be applicable for shorter off-peak times.
Stop valve · outlet · Cold water

prohibited in all circumstances because it is dangerous, since there is no control
over the water temperature anymore.
3% of the capacity of the tank when it warms up from cold. Check the tightness of the connections and the door seal once again.
If the check result is positive and if your electrical panel is equipped with an Off- peak hours (low night rate) servocontrol relay, put the switch to the "automatic" posi- tion. You will see 3 positions in this switch :
This phenomenon is normal; it is due to expansion of water due to heating. Consequently, the safety valve will allow a certain amount of water to escape so that internal pressure in the tank does not exceed 7 bars. This flow may be about 2 to
- Off or "0" position - Automatic or "AUTO" position - Forced operation or "1" position.
After switching on the water heater check the indicator light on the casing.
- When operating normally, it should be permanently lit (24 hours a day):

A water heater requires little maintenance for the user : operating the safety valve regularly (refer to the manufacturer's instructions).
Check periodically if the pilot light is on. If not, contact your local installer.
To make the performances of your heater last for many years it is necessary to have the
equipment inspected every two years by a specialist, who shall proceed as follows :
To reduce the risk of scalding: - In toilet facilities, the maximum tempe- rature of the hot water is restricted to 50°C at the outlet points; - In other facilities, the temperature of the hot water is restricted to 60°C at the outlet points.

The maintenance or repair work must be done exclusively by a professional.
This water heater has a protection system against dry heating: if the water heater is not full of water, this protection system is activated and disables power supply to the heating element.
Check if the water heater is full of water by opening a hot water tap.
✔ No hot water
No power supply to the water hea- ter: day/night contact out of order…
Switch to forced operation and check if there is any power on the power sup- ply terminal of the electronic thermo- stat.
Check if there is any power on the connector of the heating element, bet- ween blue and red wires. Circuit of the impressed current anode (ICA) is open: its wires are wrongly connected or out of order.
Heating element or its wiring out of order.
✔No heating ✔ No hot water
Visually check the connection of the impressed current anode wires.
Bad position of the water heater (HM)
Check the position of the water heater and place it in the right position. Replace the sensor.
Heat sensor missing or wrongly connected.
Check the presence and the right connection of the sensor.
Thermostat setting too low. Turn the potentiometer (refer to the connection label inside the cover). Power supply time of the water hea- ter insufficient: day/night contact out of order.
Check the good working order of the day/night contact.
✔ Water not warm enough
Heating element or its wiring partial-
Check the 3 resistances of the heating ele- ment on the connector of the element bundle and the condition of the wire bundle.
ly out of order.
Short-circuit on ICA wiring: no ICA protection.
Pilot light always off: contact the BIP Service.
✔ Pilot light always off
At the first start-up or after being switched off for a long period (secondary residence) a few minutes are needed before the light goes on.
✔ In the case of an electricity power
Storage battery out of order Note: the storage battery is recycla- ble and must not be thrown away.
Pilot light off when the water heater receives no power supply: replace the storage battery.
Contact your import sailer for any other failure. Refer to the last page of the manual for details.

ICA wiring plastic base

heating element wiring connector
supply terminal (not polarized)

The following water heater parts can be
Only use spare parts referenced by ATLANTIC.
replaced :
Whenever you order parts, specify the exact
type of the water heater, its capacity, the equipment type (TC or single phase, immersion
or ceramic), and the date of manufacture. All this information is printed on the identifica-
tion plate of the water heater, glued close to
Please call us for special parts.
the electrical switch.
Any work on electrical parts must be done by a specialist.
regulations, standards and standard practi- ce, and particularly : ● New safety valve missing or not installed according
The water heater must be installed by a qualified professional in accordance with standard practice, standards in force and the instructions in our tech- nical manuals. It must be used normally, and be regularly serviced by a specialist. Under these conditions, our guarantee includes the replacement or supply of parts recognized as being originally defective by our services, or possi- bly of the entire heater, free of charge to our distri- butor, excluding labour and transport costs and any indemnities and extension to the guarantee. Our guarantee comes into force starting from the installation date (as marked on the installation invoice). If there is no justification, the date assu- med will become the date of manufacture marked on the nameplate of the water heater, plus six months. The provisions specified in these guaran-
tee conditions do not exclude the purchaser bene- fit of the legal guarantee against hidden vices and defects, which is applicable in all cases according to the conditions of articles 1641 and subsequent articles in the civil code.
In no case the failure of a part shall justify the repla- cement of the water heater. ATLANTIC holds all the spare parts at your disposal.
A heater that is presumed to have caused damage must be left in place for inspection by experts, and the injured party must inform his insurance company.

Recommendations approved by the GIFAM ( French Interprofessional Group of Household Appliances Manufacturers) for a correct installation and use of the product.
ELECTRICAL HAZARDS : - While making the connections, follow the instructions and diagrams supplied by the manufacturer. In particular, be careful not to neutralize the thermostat (straight connection prohibited). - Be sure to use the cable type and section specified in the installation manual to prevent overheating of the power supply cable. Respect the regulations in force in any case. - Make sure an electrical protection system is provided between the heater and the power supply source protecting both the water heater and the user (example for France, a differential 30 mA circuit breaker). - Check if the connections are sufficiently tight. - It is imperative to connect the water heater to a correct earthing system. - Make sure that the current-carrying parts stay inaccessible (presence of covers in their original state). Cable passa- ges must be adapted to the diameter of these cables.
MAINTENANCE : - Check regularly if the hydraulic safety unit is still correctly working by following the instructions of the manufacturer. - All maintenance operations must be done with the water heater disconnected from the power supply.
TRANSFORMATION : - All modifications to the equipment are prohibited. Replacement of components is only allowed when done by pro- fessionals and with suitable parts.
DISCARDING : - Disconnect the power supply and drain the tank before disassembling the water heater. - Combustion of certain components may give off poison gas. Do not incinerate the water heater.