4 Symbols and safety precautions
This symbol indicates important information where there is no risk to people or property.
Additional symbols

Symbols and safety precautions | 5
Thanks for using our room thermostat, please read the following content before using:
▶Please operate this product according to the instruction. ▶Follow the manual to ensure complete functionality. ▶Install and use heaters and other accessories according to the manual. ▶Accessories only can be installed by authorized installer. ▶Before installing the accessories:
Interrupt power supply of heaters and other members of bus (220~240V AC). ▶Please inform the working way of the accessories, and guide customers to
operate. ▶Heater is switched on when freezing danger occurs, and comply with anti-freezing
▶The accessories must not be connected to power supply of 220~240V. ▶Users should learn the product default setting (refer to “ 2.2 electric
parameters”).Don’t change default setting if not necessary. ▶Mount the thermostat refer to “ 5.1 mounting position” ▶HRT-196WT is powered by OT 3.3V low voltage. ▶If the product breaks down within 12 months, we will fix it free of charge. ▶There will be an extra charge under the follow situation even if it is within the
warranty expires: – The fault is caused due to misuse or not follow the instruction; – The destruction due to flood, fire, lighting strike; – The damage caused during product dismantling and modification by the user
or mountainer not authorized by our company; – Immersion in water, damp, collisions, extrusion which destroy the product. ▶If you have any questions, please contact our manufacturer and agents.
General safety instructions

Damage caused by operational errors
Operational errors may cause personal injury and/or property damage. ▶Ensure that children should not operate and/or play with the equipment under
unattended circumstances. ▶Ensure that the equipment only can be touched by personnel who can operate the
equipment correctly.
OR80 room thermostat has the advantages of easy operation and practicality.
Please carefully read this manual before using, and operate according to requirements specified in the manual.
When communication between OT controller and wall-hung boiler is abnormal, hint "Error E1" will appear, and other failures please refer to error code introduction of wall hung boiler.
6 Product instruction

Product instruction | 7
▶Use wet cleaning cloth to wipe the housing of controller. Must not use irritant or
corrosive detergent.


[1] + (increase)/ Up key [2] Boiler working condition [3] Mode/Return key [4] – (decrease)/ Down key [5] Current mode [6] Week date [7] Current room temperature [8] Program preview [9] Heating working condition [10] DHW water working condition [11] Left key
8 Product description

Product appearance dimensions | 9
[12] 24H Display [13] Main menu/confirm/set key [14] Current time [15] Right key

The back plate of room thermostat is a standard 86*86 design and can be mounted in standard junction box or fixed on the wall.

Avoid installing the thermostat close to fridge, radiator, kitchen, computer, window, doorway or other over-cooling, over-heating and temperature changed frequently areas. The best position to install the thermostat is a dry place which can precisely reflect room temperature, and has low interference.
▶Plug flathead screwdriver into recesses at product bottom, and move up to open
back cover, as shown in Fig. 3.

10 Installation

▶Drill two holes from cable entries on the wall (space between hole centers is
60~80mm),fill the fitting expansion pipes, and then use fitting screws(PA4*30mm) to fix the back cover, (see Fig. 4).

▶Connect wire to wire holder of PCB, and align four positioning buckles with four
square holes, then fix product onto the back cover, as shown in Fig. 5.

Installation | 11

There are 6 function keys on OR80 OT room thermostat. Press the Prog key to enter into main menu, press “+” and “-” key to choose function, and press “Prog” key to set this function.
The item “temperature setting” in main menu is used for setting temperature in three modes: “+” and “-” key is for adjusting temperature, LEFT and RIGHT key is for moving operation point position, and “Prog” key is used to save setting and return to last menu.
Defrost temperature 5 °C
Economy temperature 17 °C
Comfortable temperature 20 °C

Fig.6 Temperature setting
12 Operation instruction · Default setting

Operation instruction | 13
Set current time and week under “Time/week”.
Setting temp.
User prog. Hour Sys settings 12 ˖00 MON Weekly prog. Holiday mode Boiler Info Exit
Fig. 7 Time setting
“System Set” includes “Language”, “Temperature calibration”, “Sensor setting”, “Boiler function” and “Restore factory defaults”.
Main menu · Time/week Set time/week


Fig. 8 Function setting
14 Operation instruction

Operation instruction | 15
This function is used for setting temperature mode. These modes include: office worker, comfort, economy, outing, morning shift, middle shift, night shift and user-defined. User-defined mode is a custom program mode (see part 7), other modes are set as follows:
08:00-12:00 Frost temperature
12:00-13:30 Comfort temperature
13:30-17:30 Frost temperature
17:30-08:00 Comfort temperature
office worker · Time period Temperature

00:00-00:00 Comfort temperature
00:00-00:00 Economy temperature
00:00-00:00 Frost temperature

Operation instruction | 17
07:30-16:00 Frost temperature
16:00-07:30 Comfort temperature
15:30-00:00 Frost temperature
00:00-15:30 Comfort temperature
23:30-08:00 Frost temperature
08:00-23:00 Comfort temperature
Fig. 9 Weekly program

There are as many as 48 programmable time zones per day of this thermostat, and user can set any temperature among the setting ranges in this 48 programmable time zone. Following is a 6 programmable time zone example:
Time period Temperature setting
06˖00-11˖30 Economy temperature
11˖30-13˖00 Comfort temperature
13˖00-18˖00 Economy temperature
18˖00-23˖30 Comfort temperature
23˖30-03˖00 Economy temperature
03˖00-06˖00 Comfort temperature

Fig. 10 Program
▶Press “Prog” to enter main menu; ▶Press ( - ) to select “User prog.”and press “Prog” to enter interface;
18 Program

▶When the cursor is at 00:00, setting start time to 06:00 with ”>/

▶Press “Mode” key to move the cursor to “comfort temperature”; ▶Move the cursor to “start” -6:30 with “>”, repeat the above two steps to set the
temperature for the second time period as “comfort temperature”; ▶Repeat the above operation to set the temperature of other time periods. ▶Press “+” and “-” key to copy the temperature mode of last 30 minutes, for
instance: if the temperature mode of 06:00 and 06:30 are required the same, users can easy set by directly pressing “+”. ▶Save the last step and press “prog” to quit program. All program points will be
automatically save in “User Prog”; ▶End programming.
Program | 19

20 Basic operation procedure
For initial operation, please take the following steps:
▶Please connect the room thermostat according to “section 5.1”. ▶After thermostat is connected, LCD display board is shown as below:
Press “Prog” to enter main menu.
▶Choose “Setting temp” and press “Prog” key to enter temperature setting. User
can set temperature value for three modes: anti-frost mode, economy mode and comfort mode : – De-Frost temperature: This temperature is suitable for the situation when
people stay out for a long time (such as: on vacation). And this mode will not only save energy but also can assure boiler’s and pipeline’s safety. Setting temperature range: 5-35 °C Default: 5 °C. – Economy temperature: this mode is suitable for the situation when user can
come home in a short time (such as: working hours).Setting temperature range:5-35 °C.Default point: 17 °C. – Comfort temperature: this temperature is suitable for the situation when
people stay at home. Setting temperature range:7-35 °C.Default point: 20 °C.

Basic operation procedure | 21
▶Press “Prog” key to save settings and return to main menu.
Setting temp. Setting temp.
Time/week defrost 07.0㷄 User prog. economy 15.0㷄 Sys settings comfort 20.0㷄 Weekly prog Holiday mode Boiler Info
exit
▶Press “-”key (P10) to start time &week setting, move cursor with “left” and “right”
keys, and set current time and week with “up” and “down” key. Press “Prog” key to save settings, and return to main menu.
Setting temp.
User prog Hour Sys settings 12 ˖00 MON Weekly prog Holiday mode Boiler Info
Main menu · Time/week Set time/week · exit

22 Basic operation procedure
▶Choose “boiler function” item in “system setting” and press “Prog” key to enter CH
and DWH function setting.
CH allowed Start up boiler’s CH function
CH not allowed Shut off boiler’s CH function
Selecting“√/×” with “left”and “right” key, and“√” means startup boiler’s CH function. Press “Prog” key to save settings and return main menu.
Setting temp. Sys setting
Time/week language
User prog. Temp calibrate
Sys setting Sensor setting
Weekly prog Boiler function Boiler func Holiday mode Boiler Info
CH √
Factory set Return Exit
Exit

Basic operation procedure | 23
▶Choose “weekly program” and press “Prog” key to enter mode setting. Select week
date from Monday to Sunday with “left” and “right” key, and choose different modes by pressing “mode” key. All setting periods can be previewed at the top of the LCD screen.
▶Press “Prog” key to return main display interface or automatically exit after 10
seconds.

Because of different regional, environment and electrical measuring tolerance, some deviation will exist. User can adjust the temperature through “temperature calibration”. Press “Prog(P2)” key to enter main menu – sys setting – temperature calibration. Press “up” and “down “key to set temperature point, press “Prog” to save settings and return main menu when this operation is finished.
Temp setting Sys setting Time/week language User prog Temp calibrate Sys setting Sensor setting Temp cali Weekly prog Holiday mode Boiler- Info Exit
Cur Temp
29.0 㷄
The operation of “Temp calibrate” is not suggested if deviation of room
thermostat is not obvious.
24 Temperature calibration

Holiday mode | 25
This mode is selected for the situation when people stay out for a long time (such as:
on vacation).
Temp setting Holiday length Time/week Time User prog 00 day00 hour Sys setting Weekly prog Holiday mode Boiler- Info

Main menu Set Temp
Temp setting Boiler Info Tmax 85.0㷄 Time/week Set Temp Tmin 05.0 㷄
Weekly prog Holiday -
Exit View temp
DWH 00.0 㷄
mode BoilerInfo
Exit CH 00.0 㷄
Outdoor 00.0 㷄
12 Safety instructions
This room thermostat is driven by low voltage, please be free.
26 Boiler information · Sys setting

Applicable models | 27
Boiler mode Boiler No. Serials
Eurosmart MINI L1P18 ˄WBN6000-16C ˅ 7716482002
L1P20-WBN6000 -18CRN S5500 0T1010044700023338
N1P20-WBN6000 -18HRN S5500 0T1010044700023332
L1P27-WBN6000 -24CRN S5500 0T1010044700023339
N1P27-WBN6000 -24HRN S5500 0T1010044700023333
L1P31-WBN6000 -28CRN S5500 0T1010044700023340
N1P31-WBN6000 -28HRN S5500 0T1010044700023334
“New” Eurostar


Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.