Page 1 of the Bosch OR80 OT user manual — Wall Hung Boiler Room Thermostat OR80 OT Thermostat
Pagina 1 · klik om te vergroten
Pagina 1
Bosch OR80 OT diagram (page 1)
Afb. 1

Wall Hung Boiler Room Thermostat OR80 OT Thermostat

6 720 812 419 (2014/07) en

Operating Instruction

Page 4 of the Bosch OR80 OT user manual — 1.1 Key to symbols
Pagina 4 · klik om te vergroten
Pagina 4

4 Symbols and safety precautions

1 Symbols and safety precautions

1.1 Key to symbols

  • The following keywords are defined and can be used in this document:
  • NOTICE indicates a situation that could result in damage to property or equipment.
  • CAUTION indicates a situation that could result in minor to medium injury.
  • WARNING indicates a situation that could result in severe injury or death.
  • DANGER indicates a situation that will result in severe injury or death.

This symbol indicates important information where there is no risk to people or property.

SymbolExplanation ▶Step in an action sequence Cross-reference to another part of the document •List entry –List entry (second level)

Additional symbols

Page 5 of the Bosch OR80 OT user manual — 1.2 Safety instructions
Pagina 5 · klik om te vergroten
Pagina 5

Symbols and safety precautions | 5

1.2 Safety instructions

Thanks for using our room thermostat, please read the following content before using:

▶Please operate this product according to the instruction. ▶Follow the manual to ensure complete functionality. ▶Install and use heaters and other accessories according to the manual. ▶Accessories only can be installed by authorized installer. ▶Before installing the accessories:

Interrupt power supply of heaters and other members of bus (220~240V AC). ▶Please inform the working way of the accessories, and guide customers to

operate. ▶Heater is switched on when freezing danger occurs, and comply with anti-freezing

▶The accessories must not be connected to power supply of 220~240V. ▶Users should learn the product default setting (refer to “ 2.2 electric

parameters”).Don’t change default setting if not necessary. ▶Mount the thermostat refer to “ 5.1 mounting position” ▶HRT-196WT is powered by OT 3.3V low voltage. ▶If the product breaks down within 12 months, we will fix it free of charge. ▶There will be an extra charge under the follow situation even if it is within the

warranty expires: – The fault is caused due to misuse or not follow the instruction; – The destruction due to flood, fire, lighting strike; – The damage caused during product dismantling and modification by the user

or mountainer not authorized by our company; – Immersion in water, damp, collisions, extrusion which destroy the product. ▶If you have any questions, please contact our manufacturer and agents.

General safety instructions

Page 6 of the Bosch OR80 OT user manual — 2.2 Electric parameters
Pagina 6 · klik om te vergroten
Pagina 6

Damage caused by operational errors

Operational errors may cause personal injury and/or property damage. ▶Ensure that children should not operate and/or play with the equipment under

unattended circumstances. ▶Ensure that the equipment only can be touched by personnel who can operate the

equipment correctly.

2 Product instruction

OR80 room thermostat has the advantages of easy operation and practicality.

2.1 Proper use

Please carefully read this manual before using, and operate according to requirements specified in the manual.

When communication between OT controller and wall-hung boiler is abnormal, hint "Error E1" will appear, and other failures please refer to error code introduction of wall hung boiler.

2.2 Electric parameters

Temperature setting range5~35 °C Measurement precision0.1 °C Hysteresis temperature± 1 °C DisplayLCD Dot matrix Temperature sensorNTC Power supplyOT low voltage

6 Product instruction

Page 7 of the Bosch OR80 OT user manual — 2.4 Cleaner
Pagina 7 · klik om te vergroten
Pagina 7

Product instruction | 7

2.3 Main functions and features

  • 24H Custom program function
  • Recycle control temperature from Sunday to Monday
  • Setting temperature in multi period per day
  • Menu operation mode
  • Temperature calibration
  • 128*64 dot matrix display screen
  • Display current temperature/time/week/working condition
  • 1 user program function,7 fixed modes
  • Program preview
  • Fault display function
  • Reset, quit operation function

2.4 Cleaner

▶Use wet cleaning cloth to wipe the housing of controller. Must not use irritant or

corrosive detergent.

Page 8 of the Bosch OR80 OT user manual — 7 5 6 9 10 8
Pagina 8 · klik om te vergroten
Pagina 8

3 Product description

Bosch OR80 OT — 3 Product description diagram (page 8)
Afb. 2 · 3 Product description

7 5 6 9 10 8

[1] + (increase)/ Up key [2] Boiler working condition [3] Mode/Return key [4] – (decrease)/ Down key [5] Current mode [6] Week date [7] Current room temperature [8] Program preview [9] Heating working condition [10] DHW water working condition [11] Left key

8 Product description

Page 9 of the Bosch OR80 OT user manual — 4 Product appearance dimensions
Pagina 9 · klik om te vergroten
Pagina 9

Product appearance dimensions | 9

[12] 24H Display [13] Main menu/confirm/set key [14] Current time [15] Right key

4 Product appearance dimensions

Bosch OR80 OT — 4 Product appearance dimensions diagram (page 9)
Afb. 3 · 4 Product appearance dimensions

The back plate of room thermostat is a standard 86*86 design and can be mounted in standard junction box or fixed on the wall.

Page 10 of the Bosch OR80 OT user manual — 5.2 Installation steps
Pagina 10 · klik om te vergroten
Pagina 10

5 Installation

5.1 Mounting position

Avoid installing the thermostat close to fridge, radiator, kitchen, computer, window, doorway or other over-cooling, over-heating and temperature changed frequently areas. The best position to install the thermostat is a dry place which can precisely reflect room temperature, and has low interference.

5.2 Installation steps

▶Plug flathead screwdriver into recesses at product bottom, and move up to open

back cover, as shown in Fig. 3.

Bosch OR80 OT — 5.2 Installation steps diagram (page 10)
Afb. 4 · 5.2 Installation steps

10 Installation

Page 11 of the Bosch OR80 OT user manual — 5 Installation
Pagina 11 · klik om te vergroten
Pagina 11

▶Drill two holes from cable entries on the wall (space between hole centers is

60~80mm),fill the fitting expansion pipes, and then use fitting screws(PA4*30mm) to fix the back cover, (see Fig. 4).

Bosch OR80 OT — 5 Installation diagram (page 11)
Afb. 5 · 5 Installation

▶Connect wire to wire holder of PCB, and align four positioning buckles with four

square holes, then fix product onto the back cover, as shown in Fig. 5.

Bosch OR80 OT — 5 Installation diagram (page 11)
Afb. 6 · 5 Installation

Installation | 11

Page 12 of the Bosch OR80 OT user manual — 6.1 Temperature setting
Pagina 12 · klik om te vergroten
Pagina 12

6 Operation instruction

There are 6 function keys on OR80 OT room thermostat. Press the Prog key to enter into main menu, press “+” and “-” key to choose function, and press “Prog” key to set this function.

6.1 Temperature setting

The item “temperature setting” in main menu is used for setting temperature in three modes: “+” and “-” key is for adjusting temperature, LEFT and RIGHT key is for moving operation point position, and “Prog” key is used to save setting and return to last menu.

Defrost temperature 5 °C

Economy temperature 17 °C

Comfortable temperature 20 °C

Bosch OR80 OT — 6.1 Temperature setting diagram (page 12)
Afb. 7 · 6.1 Temperature setting

Fig.6 Temperature setting

12 Operation instruction · Default setting

Page 13 of the Bosch OR80 OT user manual — 6.3 Function setting
Pagina 13 · klik om te vergroten
Pagina 13

Operation instruction | 13

6.2 Time setting

Set current time and week under “Time/week”.

Setting temp.

User prog. Hour Sys settings 12 ˖00 MON Weekly prog. Holiday mode Boiler Info Exit

Fig. 7 Time setting

6.3 Function setting

“System Set” includes “Language”, “Temperature calibration”, “Sensor setting”, “Boiler function” and “Restore factory defaults”.

  • “Language” option includes CHINESE and ENG LISH;
  • “Temperature calibration” is for correcting temperature;
  • “Sensor setting” option is for selecting indoor temperature sensor and outside temperature sensor;
  • “Boiler function” option is used for setting “CH” and “DWH” working condition;
  • “Restore factory defaults” can restore all temperatures and functions to default values.

Main menu · Time/week Set time/week

Page 14 of the Bosch OR80 OT user manual — 6.2 Time setting
Pagina 14 · klik om te vergroten
Pagina 14
Bosch OR80 OT — 6.2 Time setting diagram (page 14)
Afb. 8 · 6.2 Time setting

Fig. 8 Function setting

14 Operation instruction

Page 15 of the Bosch OR80 OT user manual — 6.4 Weekly program
Pagina 15 · klik om te vergroten
Pagina 15

Operation instruction | 15

6.4 Weekly program

This function is used for setting temperature mode. These modes include: office worker, comfort, economy, outing, morning shift, middle shift, night shift and user-defined. User-defined mode is a custom program mode (see part 7), other modes are set as follows:

08:00-12:00 Frost temperature

12:00-13:30 Comfort temperature

13:30-17:30 Frost temperature

17:30-08:00 Comfort temperature

office worker · Time period Temperature

Page 16 of the Bosch OR80 OT user manual — 6.4 Weekly program
Pagina 16 · klik om te vergroten
Pagina 16

00:00-00:00 Comfort temperature

00:00-00:00 Economy temperature

00:00-00:00 Frost temperature

Show 7 more labels / short text on this page
16 Operation instruction · Comfort · Time period Temperature · Economy · Time period Temperature · Outing · Time period Temperature
Page 17 of the Bosch OR80 OT user manual — 6.4 Weekly program
Pagina 17 · klik om te vergroten
Pagina 17

Operation instruction | 17

07:30-16:00 Frost temperature

16:00-07:30 Comfort temperature

15:30-00:00 Frost temperature

00:00-15:30 Comfort temperature

23:30-08:00 Frost temperature

08:00-23:00 Comfort temperature

Fig. 9 Weekly program

Show 4 more labels / short text on this page
Morning · Time period Temperature · Middle shift · Night shift
Page 18 of the Bosch OR80 OT user manual — 7 Program
Pagina 18 · klik om te vergroten
Pagina 18

7 Program

There are as many as 48 programmable time zones per day of this thermostat, and user can set any temperature among the setting ranges in this 48 programmable time zone. Following is a 6 programmable time zone example:

Time period Temperature setting

06˖00-11˖30 Economy temperature

11˖30-13˖00 Comfort temperature

13˖00-18˖00 Economy temperature

18˖00-23˖30 Comfort temperature

23˖30-03˖00 Economy temperature

03˖00-06˖00 Comfort temperature

Bosch OR80 OT — 7 Program diagram (page 18)
Afb. 9 · 7 Program

Fig. 10 Program

▶Press “Prog” to enter main menu; ▶Press ( - ) to select “User prog.”and press “Prog” to enter interface;

18 Program

Page 19 of the Bosch OR80 OT user manual — 7 Program
Pagina 19 · klik om te vergroten
Pagina 19

▶When the cursor is at 00:00, setting start time to 06:00 with ”>/

Bosch OR80 OT — 7 Program diagram (page 19)
Afb. 10 · 7 Program

▶Press “Mode” key to move the cursor to “comfort temperature”; ▶Move the cursor to “start” -6:30 with “>”, repeat the above two steps to set the

temperature for the second time period as “comfort temperature”; ▶Repeat the above operation to set the temperature of other time periods. ▶Press “+” and “-” key to copy the temperature mode of last 30 minutes, for

instance: if the temperature mode of 06:00 and 06:30 are required the same, users can easy set by directly pressing “+”. ▶Save the last step and press “prog” to quit program. All program points will be

automatically save in “User Prog”; ▶End programming.

Program | 19

Page 20 of the Bosch OR80 OT user manual — 8 Basic operation procedure
Pagina 20 · klik om te vergroten
Pagina 20

20 Basic operation procedure

8 Basic operation procedure

For initial operation, please take the following steps:

▶Please connect the room thermostat according to “section 5.1”. ▶After thermostat is connected, LCD display board is shown as below:

Press “Prog” to enter main menu.

▶Choose “Setting temp” and press “Prog” key to enter temperature setting. User

can set temperature value for three modes: anti-frost mode, economy mode and comfort mode : – De-Frost temperature: This temperature is suitable for the situation when

people stay out for a long time (such as: on vacation). And this mode will not only save energy but also can assure boiler’s and pipeline’s safety. Setting temperature range: 5-35 °C Default: 5 °C. – Economy temperature: this mode is suitable for the situation when user can

come home in a short time (such as: working hours).Setting temperature range:5-35 °C.Default point: 17 °C. – Comfort temperature: this temperature is suitable for the situation when

people stay at home. Setting temperature range:7-35 °C.Default point: 20 °C.

Page 21 of the Bosch OR80 OT user manual —
Pagina 21 · klik om te vergroten
Pagina 21

Basic operation procedure | 21

▶Press “Prog” key to save settings and return to main menu.

Main menu

Setting temp. Setting temp.

Time/week defrost 07.0㷄 User prog. economy 15.0㷄 Sys settings comfort 20.0㷄 Weekly prog Holiday mode Boiler Info

exit

▶Press “-”key (P10) to start time &week setting, move cursor with “left” and “right”

keys, and set current time and week with “up” and “down” key. Press “Prog” key to save settings, and return to main menu.

Setting temp.

User prog Hour Sys settings 12 ˖00 MON Weekly prog Holiday mode Boiler Info

Main menu · Time/week Set time/week · exit

Page 22 of the Bosch OR80 OT user manual — Main menu
Pagina 22 · klik om te vergroten
Pagina 22

22 Basic operation procedure

▶Choose “boiler function” item in “system setting” and press “Prog” key to enter CH

and DWH function setting.

OR80 OT

CH allowed Start up boiler’s CH function

CH not allowed Shut off boiler’s CH function

Selecting“√/×” with “left”and “right” key, and“√” means startup boiler’s CH function. Press “Prog” key to save settings and return main menu.

Main menu

Setting temp. Sys setting

Time/week language

User prog. Temp calibrate

Sys setting Sensor setting

Weekly prog Boiler function Boiler func Holiday mode Boiler Info

CH √

Factory set Return Exit

Exit

Page 23 of the Bosch OR80 OT user manual — 8 Basic operation procedure
Pagina 23 · klik om te vergroten
Pagina 23

Basic operation procedure | 23

▶Choose “weekly program” and press “Prog” key to enter mode setting. Select week

date from Monday to Sunday with “left” and “right” key, and choose different modes by pressing “mode” key. All setting periods can be previewed at the top of the LCD screen.

▶Press “Prog” key to return main display interface or automatically exit after 10

seconds.

Page 24 of the Bosch OR80 OT user manual — Boiler-func Factory-set Return Exit
Pagina 24 · klik om te vergroten
Pagina 24

9 Temperature calibration

Because of different regional, environment and electrical measuring tolerance, some deviation will exist. User can adjust the temperature through “temperature calibration”. Press “Prog(P2)” key to enter main menu – sys setting – temperature calibration. Press “up” and “down “key to set temperature point, press “Prog” to save settings and return main menu when this operation is finished.

Main menu

Temp setting Sys setting Time/week language User prog Temp calibrate Sys setting Sensor setting Temp cali Weekly prog Holiday mode Boiler- Info Exit

Boiler-func Factory-set Return Exit

Cur Temp

29.0 㷄

The operation of “Temp calibrate” is not suggested if deviation of room

thermostat is not obvious.

24 Temperature calibration

Page 25 of the Bosch OR80 OT user manual — Exit
Pagina 25 · klik om te vergroten
Pagina 25

Holiday mode | 25

10 Holiday mode

This mode is selected for the situation when people stay out for a long time (such as:

on vacation).

Main menu

Temp setting Holiday length Time/week Time User prog 00 day00 hour Sys setting Weekly prog Holiday mode Boiler- Info

Exit

Page 26 of the Bosch OR80 OT user manual — User prog View temp return
Pagina 26 · klik om te vergroten
Pagina 26

11 Boiler information

Main menu Set Temp

Temp setting Boiler Info Tmax 85.0㷄 Time/week Set Temp Tmin 05.0 㷄

User prog View temp return

Weekly prog Holiday -

Exit View temp

DWH 00.0 㷄

mode BoilerInfo

Exit CH 00.0 㷄

Outdoor 00.0 㷄

12 Safety instructions

This room thermostat is driven by low voltage, please be free.

26 Boiler information · Sys setting

Page 27 of the Bosch OR80 OT user manual — N1P17 ˄ WBN6000-15S ˅ 7716482003
Pagina 27 · klik om te vergroten
Pagina 27

Applicable models | 27

13 Applicable models

Boiler mode Boiler No. Serials

Eurosmart MINI L1P18 ˄WBN6000-16C ˅ 7716482002

N1P17 ˄ WBN6000-15S ˅ 7716482003

L1P20-WBN6000 -18CRN S5500 0T1010044700023338

N1P20-WBN6000 -18HRN S5500 0T1010044700023332

L1P27-WBN6000 -24CRN S5500 0T1010044700023339

N1P27-WBN6000 -24HRN S5500 0T1010044700023333

L1P31-WBN6000 -28CRN S5500 0T1010044700023340

N1P31-WBN6000 -28HRN S5500 0T1010044700023334

“New” Eurostar

Page 28 of the Bosch OR80 OT user manual — 13 Applicable models
Pagina 28 · klik om te vergroten
Pagina 28
Bosch OR80 OT — 13 Applicable models diagram (page 28)
Afb. 11 · 13 Applicable models

Vraag stellen over de Bosch OR80 OT

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Bosch OR80 OT

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Bosch OR80 OT handleiding-pdf

28 pagina's·1.5 MB·Thermostaat·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…