1 - 1 Power supply
Turning on or off
To turn the calculator on, press [ ON ] ; To turn the calculator off, press [ 2nd ] [ OFF ].
Battery replacement
SRP-280 is powered by two alkaline batteries (GP76A). SRP-285 is dual power system which is powered by one alkaline battery (GP76A) and a solar cell. If the display becomes dim and difficult to read (especially when lighting is dim for SRP-285), the batteries should be replaced as soon as possible.
To replace batteries : 1) Remove the screws and the back cover. 2) Replace the old batteries and install new ones with polarity in correct directions, then secure the screws in place and press [ ON ] to turn the power on.
Auto power-off function
This calculator automatically turns it off when not operated for approximately 9~15 minutes. It can be reactivated by pressing [ ON ] key and the display, memory, settings are retained.
Reset operation
If the calculator is on but you get unexpected results, press [ 2nd ] [ RESET ] in sequence. A message appears on the display to confirm whether you want to reset the calculator and clear memory contents.
Move the cursor to “ Y ” by [], then press [ ENTER ] to clear all variables, programs, pending operations, statistical data, answers, all previous entries, and memory; To abort the reset operation without clearing the calculator, please choose “ N ” .
If the calculator is lock and further key operations becomes impossible, please press [ 0 ] [ DMS ] at the same time to release the condition. It will return all settings to default settings.
Pressing the [] or [] following [ MODE ] key can make the contrast of the screen lighter or darker. Holding either key down will make the display become respectively lighter or darker.

The display comprises the entry line, the result line, and indicators.
MAIN Ï 74 – 8 ÷ 7 66.
Entry line SRP-280 displays an entry of up to 76 digits. SRP-285 displays an entry of up to 80 digits. Entries begin on the left ; those with more than 11 digits scroll to the left. Press [] or [] to move the cursor through an entry. Press [ 2nd ] [] or [ 2nd ] [] to move the cursor immediately to the beginning or end of the entry.
Result line It displays a result of up to 10 digits, as well as a decimal, a
negative sign, a “ x10 ” indicator, and a 2-digits positive or negative exponent. Results that exceed the digit limit are displayed in scientific notation.
Indicators The following indicators appear on the display to indicate you the current status of the calculator.
Indicator Meaning M Independent memory – Result is negative, or the entry line is full 2nd 2nd set of function keys is active. MODE Mode selection is active MAIN Main mode is active STAT Statistics mode is active Base-n Base-n mode is active VLE Variable linear equation mode is active QE Quadratic equation mode is active CPLX Complex number mode is active DEGRAD Angle mode : DEGrees, GRADs, or RADs ENGSCI ENGineering or SCIentific notation. TAB Number of decimal places displayed is fixed HYP Hyperbolic-trig function will be calculated BUSY While an operation is executing Í Î There are digits to the left or right of the display Ï Ð There are earlier or later results that can be displayed
Many of the calculator’s keys are used to perform more than one function. The functions marked on the keyboard are printed differently to help you find the one you need quickly and easily.
White Direct input Yellow Press [ 2nd ] and then key Green Press key in Base-n mode

Changing a mode
Pressing [ MODE ] can enter mode menus. You can choose one of six oper- ating modes, including “ 0)MAIN ”, “ 1)STAT ”, “ 2)Base-n ”, “ 3)CPLX ”, “ 4)VLE ”, “ 5)QE ”.
Give “ 2)Base-n ” as an example :
Method 1 : Scroll through the menus using [] or [] until “ 2)Base-n ” is shown, then enter the desired mode by pressing [ ENTER ].
Method 2 : Key in directly the number of the mode, [ 2 ] , to enter the mode immediately.
Selecting an item from display menus
Many functions and settings are available on menus. A menu is a list of options displayed across the entry line.
Give “ Pressing [ DRG ] key displays the menu for choosing the angle setting under MAIN mode ” as an example :
Method : Press [ DRG ] to display the menu, and then move the cursor [] or [] to an item you want. Press [ ENTER ] while the item is underlined.
For menu items followed by an argument value, enter the argument value while the item is underlined. The item and the argument value are displayed in the previous screen.
Using “ 2nd ” keys When you press [ 2nd ], the “ 2nd ” indicator shown in the display is to tell you that you will be selecting the second function of the next key you press. If you press [ 2nd ] by mistake, simply press [ 2nd ] again to remove the “ 2nd ” indicator.
Cursor
Pressing [] or [] key can move the cursor to the left or the right. Hold down any of those keys to move the cursor at high speed. Pressing [] or [] can scroll the display up or down while there are previous entries hidden the display. You can reuse or edit a previous entry when it is on the entry line.
Making corrections during input
To delete a character at the cursor, make the character underlined by using [] or [] to move the cursor, and then press [ DEL ] to delete the character. Besides, holding down [ DEL ] can deletes all characters to the right ; then,

deletes 1 character to the left of the cursor each time you press [ DEL ].
To replace a character, make the character underlined by using [] or [] to move the cursor, and then enter a new entry to replace the character.
To insert a character, move the cursor to the position of the character where you want to insert, it will be inserted in the front of the character after pressing [ 2nd ] [ INS ] and entering a new character.
On the contrary, the blinking cursor is displayed as “_” and it means the calculator is in overwrite mode.
To clear all characters, clear all input character by [ CL ] key.
Replay function
(Note) :The replay function isn’t cleared even when [ CL ] is pressed or
power is turned off, so contents can be recalled even after [ CL ] is pressed. However, replay function is cleared when mode or opera- tion is switched.
Error position display function
Memory calculation
* [ P/V RCL ] recalls all variables.

* [ SAVE ] lets you store values to variables. * [ 2nd ] [ RECALL ] recalls the value of variable. * [ 2nd ] [ CL-VAR ] clears all variables except PROG. * [ 2nd ] [ CL-PROG ] clears the contents of PROG.
Order of operations
Each calculation is performed in the following order of precedence :
1) Expression inside parentheses. 2) Coordinates transformation, and Type B functions which are required pressing the function key before entering, for example, sin, cos, tan, sin –1, cos –1, tan –1, sinh, cosh, tanh, sinh –1, cosh –1, tanh –1, log, ln, 10 X , e X, √, NEG, NOT, X ’( ), Y ’( ). 3) Type A functions which are required entering values before pressing the function key, for example, X 2, °‘ “ , !, X –1, %, r, g. 4) Exponentiation ( ^ ), X√ 5) Fractions 6) Abbreviated multiplication format in front of variables, π, RAND. 7) ( – ) 8) Abbreviated multiplication format in front of Type B functions 2√3, Alog2, etc. 9) nPr, nCr 10) x , ÷ 11) +, – 12) AND, NAND 13) OR, XOR, XNOR 14) Conversion (A b/c d/e, FD, DMS) • When functions with the same priority are used in series,
execution is performed from right to left.
priority.
Accuracy and Capacity
SRP-285 → 14 digits
In general, every reasonable calculation is displayed up to 10 digits mantissa, or 10-digits mantissa plus 2-digits exponent up to 10 ± 99.
Numbers used as input must be within the range of the given function as follow :


Error conditions
Error massage will appear on the display and further calculation becomes impossible when any of the following conditions occur.
DOMAIN Er When specifying an argument to a DOM function outside the valid range. Error
DOMAIN Er FREQ value ( in 1-VAR stats) < 0 FREQ DOMAIN or non-integer. Error
DIVIDE BY O You attempted to divide by 0. DIVIDE BY O
OVERFLOW Er When result of function calculations OVERFLOW exceeds the range specified. Error
Error

STAT Er When not in STAT mode, pressing [ DATA ] or [ STATVAR ].
SYNTAX Er (1) Input errors are made. SYN (2) When improper arguments are used Error in commands or functions that require arguments.
NO SOL There is no solution or infinite to NO SOL MULTI SOLS the simultaneous equation under MULTI SOLS VLE mode.
NO REAL SOL There is no real solution to quadratic NO REAL SOL equation under QE mode.
LENGTH Er An entry for SRP-280 exceeds 84 digits IMP LENGTH (The limit for SRP-285 is 88 digits) after Error implied multiplication with auto-correction.
To release the above errors, please press [ CL ] key.
2 - 1 Arithmetic calculation

the mantissa can have up to three digits left of the decimal, instead of only one, and the exponent is always a multiple of three. It is useful for engineers to convert units based on multiples of 10 3.
of all functions, except memory variables, left parenthesis, type B functions.

be used for further calculation. See Example 21.
Answer memory retains its current value.
Fraction value display is as follow :
5 /12 Display of 12 5
56 ∪ 5 / 12 Display of 56 12 5
180 ° =πrad = 200 grad Angle conversations ( See Example 28.) :

angle unit you want.
angle unit you want.
Rectangular Coordinates Polar Coordinates
Y
x + y i= r (cos θ + i sin θ)
unit you want.
r · y · 0 X θ

nPr Calculates the number of possible permutations of n item taken r at a time. nCr Calculates the number of possible combinations of n items taken r at a time. ! Calculates the factorial of a specified positive integer n , where n≦69.
< SRP-280 > RANDM Generates a random number between 0 and 1.
< SRP-285 > RAND Generates a random number between 0 and 1.
Symbol Meaning Value c Speed of light 299792458 m / s g Acceleration of gravity 9.80665 m.s – 2
G Gravitational constant 6.6725985 x 10 – 11 N.m 2 kg – 2
Vm molar volume of ideal gas 0.0224141 m 3 mol – 1
NA Avagadro’s number 6.022136736 x 10 23 mol – 1
e Elementary charge 1.6021773349 x 10 –19 C

me Electron mass 9.109389754 x 10 –31 kg
mp Proton mass 1.672623110 x 10 –27 kg h Plank’s constant 6.626075540 x 10 –34 J.s k Boltzmann’s constant 1.38065812 x 10 –23J.K –1
To insert a constant at the cursor position ( See Example 37.) :
There are three menu operation in statistics menu : 1 -VAR ( for analyzing data in a single dataset), 2 - VAR ( for analyzing paired data from two datasets ) and CLR- DATA ( for clearing all datasets). See Example 38.
To enter data for statistical analysis :
To analyze data you have entered :
1. Press [ STATVAR ]. A range of statistical variables (see table below ) is displayed on the statistical result menus. The first variable ( n ) is underlined and its value is on the result line. 2. Press [] to scroll through the statistical results menu. The value of each variable is displayed on the result line. 3. To use a value in a calculation, press [ ENTER ] when the values is displayed. The values is copied to the entry line. 4. To predict a value for x ( or y ) given a value for y ( or x ), select the x ’ ( or y ’ ) variable, press [ ENTER ], enter the given value, and press [ ENTER ] again. Variable Meaning n Number of x values or x-y pairs entered. _ _ x or y Mean of the x values or y values Sx or Sy Sample standard deviation of x values or y values.
σ x or σ y Population standard deviation of x values or y values Σ x or Σ y Sum of all X values or y values
Σ x 2 or Σ y 2 Sum of all x 2 values or y 2 values

Σ x y Sum of (x x y) for all x-y pairs a Linear regression y-intercept b Linear regression slope r Correlation coefficient x ’ Predicted x values given a, b, and a y values y ’ Predicted y value given a, b, and x value.
just pressing [] or [] can continue viewing next statistical vari- able value.
To view or change data :
(Note) : Even you exit STAT mode, all data in 1 - VAR and 2 - VAR mode
are still retained unless you clear all data by selecting CLR - DATA mode.
4 - 1 Bases conversions
(Note) : The total range of numbers handled in this mode is 0, 1, 2, 3, 4, 5,
6, 7, 8, 9, A, B, C, D, E, F. If values not valid for the particular number system are used, attach the corresponding designator (d, h, b, o), or an error message will appear.
Binary base ( b ) : 0, 1 Octal base ( o ) : 0, 1, 2, 3, 4, 5, 6, 7 Decimal base ( d ) : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 Hexadecimal base ( h ) : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F
] can use block function to display a result in octal or binary base which exceeds 8 digits. The system is designed to display up to 4 blocks. See Example 40.

Re Real value Im Imaginary value ab Absolute value ar Argument value
Variable linear equations (VLE) mode can solve a set of simultaneous equations with two unknowns as follows :
a x + b y = c d x + e y = f, where x and y are unknown.
Quadratic equations (QE) mode can solve a equations as follows :
a x 2 + b x + c = 0, where x is unknown.


Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.