Thank you for choosing our product. We hope you enjoy using the appliance.
Symbols in these Instructions for Use Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid acci- dents and prevent damage to the machine:
Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the warranty, the receipt and, if possible, the box with the internal

1 Air outlet 2 Handle 3 Control panel with display 4 Air inlet and filter
5 Mains cable 6 Rated breaking point for hose connection 7 Water collection tank 8 Water hose
Button Function Indicator lamp
FULL Without function for this unit
Water collection tank full
POWER Turning the unit on and off
SETTING Setting the air humidity level
TIMER Activating the timer
SPEED Setting the power of the fan
Initial operation
1 Unit 1 Water hose, 10 mm
Mains connection 1. Make sure the mains voltage you want to use corresponds to the voltage of the unit. Please check the rating label for de- tailed specifications. 2. Connect the unit to a properly installed grounded socket. A signal will sound indicating that the unit is ready for use.
slowly · fast

indicator lamp indicates that the unit is ready for use. • If the SPEED
indicator lamp lights up, the previous operation had been stopped due to power failure. The unit will start immediately with the previously selected settings (except for timer function).
Emptying the water tank (see figure C on page 4) The water collection tank (7) collects the water from the air humid- ity. When this tank is full, the unit will emit several beeps. The unit will automatically switch into STANDBY mode. The
indicator lamp lights up. You must empty the water tank in order to continue operation.
Setting the humidity level Press the SETTING button to select the desired air humidity level. Select a setting between 40% and 80% in increments of 5%.
Fan settings Press the SPEED button to switch between slow and fast power setting of the fan.
Timer (Automatic timer) Use the timer function to set the power-on and power-off times of the unit. Select a time between 1 and 24 hours.
Using the timer function for automatic power-on 1. Press the POWER button to turn on the unit. 2. Select the desired air humidity level. Then select the fan power setting to be used when the unit starts operation when pow- ered on. 3. Press the POWER button to turn off the unit. 4. Press the TIMER button repeatedly to set the hour as desired. When performing the setting, the hours flash in the display.
Terminating operation 1. Press the POWER button to turn off the unit. The SPEED indicator lamp and possibly the TIMER indicator lamp will also turn off. 2. Disconnect the mains plug from the wall socket. The POWER indicator lamp turns off.
When the time has elapsed, the unit will turn on automatically.
Using the timer function for automatic power-off 1. Press the POWER button to turn on the unit. 2. Press the TIMER button repeatedly during operation to set the hours as desired. The hours after which the unit will power off automatically, will briefly flash.
or

Filter (see figure D on page 4) Clean the filter every 2 weeks if using the unit daily. If dust inside the filter blocks air circulation, the efficiency of the unit can no longer be guaranteed. 1. Remove the grid from the air inlet (4) by pressing down the snap tabs. 2. Remove the filter. 3. Vacuum the rear side of the unit at the location of the air inlet. 4. Clean the filter under running water. If necessary, use a mild detergent. 5. Let the filter air-dry in a shady place. 6. Reinstall the filter after it has dried completely. 7. Then reattach the grid to the unit.

Close any windows or doors. The filter is dirty. Clean the filter. The air inlet or air outlet is blocked.
Remove the blockage. Keep the ventilation openings free from obstructions. Unit too noisy during opera- tion.
Place the unit on a flat surface. Avoid vibra- tions.
Model: LE 3612 Net weight: approx. 10.5 kg Power supply: 220 - 240 V~, 50 Hz Power consumption: 245 W Protection class: I Refrigerant: R 134 A Dehumidification capacity: 10 liters / 24 hours
The right to make technical and design modifications in the course of continuous product development remains reserved.
When not using the unit for a long period of time, proceed as follows: 1. Press the POWER button to turn off the unit. Disconnect the mains plug from the wall socket. 2. Empty the water tank as described above. 3. If necessary, remove the water hose. 4. Clean the water tank, filter and unit as previously instructed. 5. Cover the unit with foil. 6. Always store the unit out of the reach of children in a dry, well ventilated place.
This device has been tested according to all relevant current CE guidelines, such as electromagnetic compatibility and low voltage directives, and has been constructed in accordance with the latest safety regulations.
Troubleshooting
Meaning of the “Dustbin” Symbol Protect our environment: do not dispose of electrical equipment in the domestic waste.
Problem Possible cause Solution Unit does not function.
No power supply. Check the power con- nection. Timer function is acti- vated.
Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.
Press the POWER but- ton to turn on the unit. The
This helps avoid the potential effects of incorrect disposal on the environment and human health.
indicator lamp lights up.
Empty the water tank. You may then restart the unit again. Is the room tempera- ture lower than 5°C or higher than 35°C?
This will contribute to the recycling and other forms of reutilisation of electrical and electronic equipment.
The protection mech- anism has been acti- vated. The unit cannot start at such tempera- tures.
Information concerning where the equipment can be disposed of can be obtained from your local authority.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Insuffci ient dehumidifci a- tion. | Windows or doors are open. | Close any windows or doors. | p.4 |
| Insuffci ient dehumidifci a- tion. | The fliter is dirty. | Clean the fliter. | p.4 |
| Insuffci ient dehumidifci a- tion. | The air inlet or air outlet is blocked. | Remove the blockage. Keep the ventilation openings free from obstructions. | p.4 |
| Unit too noisy during opera- tion. | The unit is not in an upright position. | Place the unit on a fal t surface. Avoid vibra- tions. | p.4 |