SOURCES OF DANGER DURING ARC WELDING Arc welding results in a number of sources of danger. It is therefore particularly important for the welder to com- ply with the following rules so as not to place himself or others in danger and to avoid endangering people and equipment. 1. Have all work on the mains voltage system, for ex- ample on cables, plugs, sockets, etc., performed only by trained electricians. This particularly applies to confi guring intermediate cables. 2. If an accident occurs, disconnect the welding power source from the mains immediately. 3. If electric touch voltages occur, switch off the weld- ing set immediately and have it checked by an ex- pert. 4. Always check for good electrical contacts on the welding current side. 5. Wear insulating gloves on both hands for welding. These offer protection from electric shocks (idling voltage in the welding circuit), harmful radiation (Heat and UV radiation) and from glowing metal and slag spatter. 6. Wear fi rm, insulated footwear. Your shoes should also protect you in wet conditions. Open- toed foot- wear is not suitable since falling droplets of glowing metal will cause burns.
Please note

7. Wear suitable clothing, do not wear synthetic clothes. 8. Do not look into the arc with unprotected eyes, use only a welding safety shield with the proper safety glass in compliance with DIN standards. In addition to light and heat, which may cause dazzling and burns, the arc also gives off UV radiation. Without proper protection, this invisible ultraviolet radiation causes very painful conjunctivitis, which will only be noticeable several hours later. In addition, UV radiation will cause sunburn-type symptoms on un- protected parts of the body. 9. Personnel or assistants in the vicinity of the arc must also be notifi ed of the dangers and provided with the required protection; if necessary install safety walls. 10. Ensure adequate ventilation for welding, particular- ly in small rooms since the process causes smoke and harmful gases. 11. Do not carry out any welding work on tanks that have been used to store gases, fuels, mineral oil or the like, even if they have been empty for a lengthy period of time, since any residue will result in a dan- ger of explosion. 12. Special regulations apply in areas where there is a potential risk of fi re and/or explosion. 13. Welds that are exposed to large stresses and must comply with safety requirements may only be com- pleted by specially trained and approved welders. Examples of such welds include pressure vessels, rails, trailer hitches, etc. 14. Only use a power source (with earthing contact) that is protected with a slow-blow fuse, a slow-triggering circuit breaker and a residual current device. The fuses must comply with the relevant regulations (VDE 0100). To comply with these regulations, only fuses or circuit breakers suitable for the cross- section of the cables may be used. The use of too high a fuse may result in the cable burning and fi re damage to the building. This appliance is not designed for commercial use.
PROTECTION FROM RADIATION AND BURNS 1. Provide information about the risk to eyes at the working site in the form of a poster with the wording «Caution - do not look at the fl ames». Workplaces are to be screened off wherever possible so that personnel in the vicinity are protected. Unauthorized persons are to be kept away from the welding work. 2. The walls in the immediate vicinity of stationary workplaces should not have a light color or a sheen. Windows up to head height are to be protected against radiation passing through them or refl ecting off them, for example by coating them with a suitable paint.
50 Hz Mains frequency
U1 Mains voltage
I1 max Rated maximum mains current
Fuse with rated value in A
U0 Rated idling voltage
I2 Welding current
Ø mm Electrode diameter
nc/nc1 Number of welding electrodes that can be melted. a) from a cold state up to the trip point of the temperature monitor (nc) and b) within the fi rst hour from the cold state (nc1)
CONSTRICTED AND WET AREAS When working in constricted, wet or hot areas, use insulating supports and intermediate layers as well as slip-on gloves made of leather or other non-conductive materials to insulate your body against the fl oor, walls, conductive parts of the machine and the like. If you use small welding transformers for welding in places with an increase electrical risk, for example in constricted areas with conductive walls, (tanks, pipes, etc.), in wet areas (which make work clothes wet) and in hot areas (perspiration on work clothes), the output voltage of the welding set when idling must not exceed 42 V (effective value). Therefore, the appliance may not be used for these purposes because its output volt- age is higher than this. Safety clothing 1. While working, the welder must protect his entire body from radiation and burns by wearing suitable clothing and a face guard. 2. Slip-on gloves made of a suitable material (leather) must be worn on both hands. They must be in per- fect condition.
nh/nh1 Number of welding electrodes that can be melted a) in a hot state between the temperature monitor switching on and off (nh) and b) over a period of one hour in a hot state from being switched on again (nh1)
Symbol for falling characteristic curve
Symbol for manual arc welding with sheathed rod electrodes
IP 21 Protection type
Single-phase transformer

X Duty Cycle (measured in % from standard 5 min cycle). For in-stance, 10% means that each 30 seconds use shall be followed by 4 min 30 sec break. Stick to this to prolong the service life of your welding machine.
The set is interference-suppressed in compliance with EC Directive 89/336/EEC
Important! Do not dab the workpiece with the electrode since it could be damaged, making it more diffi cult to ignite the arc. As soon as the arc has ignited, attempt to keep it a distance from the workpiece equivalent to the diameter of the electrode. This distance should be kept as constant as possible during the welding process. The angle of the electrode in the direction in which you are working should be 20/30°.
6. WELDING PREPARATIONS Important! Always make sure the device is unplugged before connecting or disconnecting the welding cable! Connect the welding cables as shown in (fi g. 3 ). To do so, connect the cable with the electrode holder to the positive pole quick-lock coupling and the ground terminal to the negative pole quick-lock coupling. Lock the connectors in place by turning them in a clockwise direction. Connect the earth terminal direct to the part to be welded or to the support on which the part is resting. Ensure that the earth terminal is in direct contact with the part to be welded. You should therefore avoid coat- ed surfaces and/or insulated materials. The electrode holder cable has a special clamp at one end, which is used to secure the electrode. The welding safety shield must be used at all times for welding. It protects your eyes from the radiation emitted by the arc and never- theless enables you to watch the welding process.
Important! Always use tongs to remove spent electrodes and to move parts that you have just welded. Please note that the electrode holder must always be put down so that it is insulated after you have completed the weld- ing work. Do not remove the slag until the weld has cooled. If you want to continue a weld after an interruption, the slag from your initial attempt must fi rst be removed. Switch off and unplug the machine after operation.
7. WELDING After you have made all the electrical connections for the power supply and for the welding circuit, you can proceed as follows: Insert the unsheathed end of the electrode into the electrode holder and connect the earth terminal to the part you wish to weld. Ensure that a good electric contact is made. Switch on the welding set at the switch and set the welding current using the hand wheel to suit the electrode you wish to use. Hold the safety shield in front of your face and rub the tip of the electrode on the part you wish to weld as if you were striking a match. This is the best method of igniting the arc. Check that you have the correct electrode and current strength on a test part.
H Insulation class
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.