Congratulations on your purchase of this Dik Geurts fire. DRU Verwarming, a fire manufacturer, develops and produces products that comply with the highest quality, performance and safety requirements. This will enable you to enjoy using this product for many years to come. This fire is provided with a CE mark. Wood burning fires that comply with the essential requirements for safety, environment and energy consumption, etc. of the European Construction Products Directive, are entitled to carry the CE mark. The Dik Geurts wood burning fire has an ingenious burning system which ensures effective and clean combustion combined with optimum efficiency. The combustion air is regulated by means of the air supply slide. In this user manual you can read how it works. This appliance is supplied with two manuals: the installation manual and the user manual. The user manual will give you the information you need to operate the appliance in a proper, safe and environmentally friendly way. Carefully read this user manual, before you take this fire into operation. The figures can be found in the appendix at the back of this booklet. Keep the user manual AND the installation manual in a safe place. As a user you are only entitled to perform the work described in the user manual. All other work should be performed by a recognized installer. In case of questions or doubts, please contact your supplier. The following symbols are used in the manual to indicate important information: Ø Work to be performed
!Tip Suggestions and recommendations
!Caution These instructions are necessary in order to prevent possible problems during use
!CAUTION You need these instructions to prevent fire, personal injury or other serious damages

2.2 Precautions / safety instructions Carefully observe the following measures/regulations:
!CAUTION Your fire must be installed by a skilled, recognized installer of wood burning appliances.
!CAUTION Have the fire installed in accordance with the applicable national, local and constructional (installation) regulations.
!Caution The flue duct must be assessed in advance concerning its suitability for the appliance, and should be inspected and/or cleaned by a recognized specialist. Due to the utilisation of new, innovative techniques, the combustion temperature is higher than it was in the past. Have the flue duct inspected and cleaned by a specialist, at least once or twice per year. Only with a good duct, your fire will perform in a safe and faultless way.
!Caution In case of a combustible floor, you must place a fireproof floor plate under the appliance, which will be available at your supplier as an accessory.
!Caution Do not make any changes to the fire yourself.
!Caution Only replace parts by original parts.
!CAUTION Do not perform any work when the fire is still hot, wait at least 24 hours after use.
!Caution Only burn the fire with the recommended fuel (see section 5.1).
!Caution Do not use the fire as a waste incinerator.
!CAUTION The minimum distance between the fireplace/chimney pipes and combustible objects/materials stated on the data
plate should be taken into account.
!CAUTION Do not place combustible materials under the appliance.
!CAUTION Do not allow clothes, towels etc. to dry on and/or near the appliance, in order to prevent fire.
!CAUTION Avoid contact with a burning fire in order to prevent burns and/or clothes catching fire.
!CAUTION During use, the outside of the fire will become very hot. Therefore, you should use the supplied oven glove when
operating the fire.
!CAUTION Never leave children and persons who are unable to judge the consequences of their actions by themselves near a
burning fire.
!CAUTION Avoid working with solvents, glue, PUR foam, etc. in the room during use of the fire.
!Caution The fire is intended as atmospheric heating and is not developed for continuous use as main heating.
!Caution The fire is not suitable for use as a barbecue.
!Caution Make sure that there is an adequate supply of fresh air; if possible, this air may be supplied via an EA/RS connection.
!CAUTION In case of a fire in the chimney, close the air supply, extinguish the wood fire with sand and call the fire brigade.
!Caution Carefully read chapter 3 ‘Taking into operation’, before you start to burn.

2.3.1 Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the Environment respectively.
Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements.
The Dik Geurts Instyle 400, 500, 550, 600, 650 and 700, Dik Geurts Instyle Corner Slim 660/495, Dik Geurts Prostyle 500, 550, 600, 650 and 700, Dik Geurts Keld 5 LowEA and Keld 5 HighEA, Dik Geurts Ivar 5 LowEA and Ivar 5 HighEA, Dik Geurts Jannik Medium LowEA, Dik Geurts Aste 5 LowEA/RS, Dik Geurts Odin FrontEA, Dik Geurts Ivar 5 storeEA, Dik Geurts Ivar 8 StoreEA, Dik Geurts Ivar 8 LowEA wood burning stove , Dik Geurts Modivar 5 EA/RS and OlafEA wood burning stove have been recommended as suitable for use in smoke control areas when burning wood logs.
The Ivar 8 StoreEA and Ivar 8 LowEA wood burning stove must be fitted with a permanent stop to prevent closure of the primary air control beyond the 6.0cm open position. OlafEA wood burning stove must be fitted with a permanent stop to prevent closure of the primary air control beyond the 5.3cm open position.
Exemption details can be found at: https://smokecontrol.defra.gov.uk/appliances.php Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/smoke-control-area-rules
2.3.2 Exempt appliances Exempt appliances are appliances (ovens, wood burners and stoves) which have been exempted by Statutory Instruments (Orders) under the Clean Air Act 1993 or Clean Air (Northern Ireland) Order 1981. These have passed tests to confirm that they are capable of burning an unauthorised or inherently smoky solid fuel without emitting smoke.
Appliances which are authorized for use in Smoke Control Areas: http://smokecontrol.defra.gov.uk/appliances.php

2.4.2 Extractor fan There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room.
2.4.3 Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air. This air vent should not under any circumstances be shut off or sealed.
2.4.4 Chimney cleaning The chimney should be swept at least twice a year. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period. If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove.
2.4.5 Periods of prolonged non-use If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open.
2.4.6 Use of fireguard When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 8423:2002 (Replaces BS 6539).
2.4.7 Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
2.4.8 Aerosol sprays Do not use an aerosol spray on or near the stove when it is alight.
2.4.9 CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions given under “Warning Note” above.

!Tip Touch up any damages to the paint before taking the fire into operation for the first time. This will prevent colour variations.
!Tip Do not touch the fire during hardening in order to prevent damaging the paint.
!Caution Vent the room properly because of the evaporation of heat resistant paint.
!CAUTION Remove pets from the room because of the released vapours when hardening the paint.
3.2 Fastening the cold (door) handle If your appliance is provided with a stainless steel, detachable (door) handle (see Appendix 2, Fig. 2), you will also be able to fasten it.
To do this proceed as follows: Ø Open the door. Ø Place the stainless steel handle in the correct position in the door (see Appendix 2, Fig. 2). Ø Rotate the (door) handle in such a way, that the head of the adjusting screw points in your direction. Ø Use an Allen key to fasten the adjusting screw (be careful, overtightening will cause breakage). Now the (door) handle is locked to the door.
If you want to disassemble the (door) handle you should perform the above-mentioned steps in opposite order.
3.3 Protection In order to prevent unsafe situations, you must carefully observe the following measures/instructions.
3.4 Discolouration of walls and ceilings A brown discolouration is annoying and it is a problem that is difficult to solve. Brown discolouration can be caused by the combustion of dust as a result of the materials used, too little ventilation, smoking, the burning of candles, oil lights, etc. Smoke from cigarettes and cigars contains tar substances that can be deposited on colder and/or moist walls.

4.1 Instructions Observe the following instructions for a good and safe operation of your fire:
!CAUTION Have your flue duct checked by a recognized specialist for blockage and contamination if you have not burned the
fire for some time.
4.2 Lighting Observe the following steps for lighting and burning your fire: Ø If necessary, remove a part of the ash with the supplied ash scoop (see section 5.4). Ø If necessary, clean the glass pane (see section 6.6). Ø If applicable, open the flue valve. Ø Fully open the air supply using the air supply slide (with indication closed/open, see Appendix 2, Fig. 3a and 3b); Ø Place 2 small wood blocks in the combustion chamber, lengthwise (see Appendix 2, Fig. 4); Ø Stack kindlings crosswise on the 2 wood blocks and place a firelighter on top of it (see Appendix 2, Fig. 5). Ø Make sure that sufficient air is able to flow through the stack of wood, so that the wood will easily ignite. Ø Light the firelighter and, if applicable, a ball of paper. Ø Close the fire door, it may be left open a little bit, if necessary, until the kindlings have caught fire. Ø Allow the fire to burn through properly in order to heat up the flue duct. In this way, a good draught is created. Ø To keep the glass pane clean, allow the fire to burn hot until it burns out.
4.3 Burning Ø Allow the fire to continue burning on small wood blocks until a properly burning fire is created with a glowing ember bed. Ø In case of a wide fire: now distribute the glowing fire bed over the fire's width and place a few more small wood blocks on top of it. Ø Control the output with the air supply slide only after approx. 15-20 minutes when there is a properly burning fire with ember bed. Simply allow the appliance to continue burning using the air supply slide. Ø Then fill the fire with larger wood blocks (see table 2 in Appendix 1 for the amount) after the small wood blocks have been burnt for a large part. If necessary, further open the air supply slide for a moment, to allow the fire to burn properly again.
!CAUTION Make sure that wood blocks do not fall/lie against the glass pane.
!CAUTION For good combustion and optimal ease of use, always heat the appliance to capacity.

!Tip A steadily burning fire stimulates combustion.
Ø Refill the fire before the flames have gone out of the fire. This will be approximately every 30 to 45 minutes. Ø Close the door and open the air supply slide all the way until the new wood blocks are burning well. See Table 2 for the recommended quantities of wood. Ø Using the air supply slide, adjust the draught until a steady flame pattern is achieved. Ø Always allow the fire to burn empty when you stop burning. Smoke Light coloured (white or colourless) smoke indicates that suitable wood is used and that there is a good combustion. Grey, blue or even black smoke is created in case of incomplete combustion, e.g. as a result of moist or excess wood.
4.4 Fire with oven (if applicable) If your fire is provided with an oven, you can use it to heat or cook dishes.
You can close the oven, using the valve (see Appendix 2, Fig. 6 (K)). You will usually suspend it at the side of the fire, because air for glass pane aeration is supplied by the oven. Use the oven glove for this. When used, you must always place aluminium foil in the oven in order to avoid fat from getting on the oven surface and burning into it. Only use the oven after the fire's paint has hardened (see section 4.1).
4.5 Fire with fan(s) Appliances that are made with fans will heat a room more quickly and increase comfort. As soon as the fan is switched on you will be able to feel a pleasant warm air flow.
4.5.1 How the fan(s) work The fans are operated by means of the switch on the appliance.
We distinguish three positions (see Appendix 2, Fig. 8): Position I – ON (the fans are running, irrespective of the fire's temperature) Position O – OFF (the fans are off) Position II – AUTO (the fans will only run when the fire has reached the required temperature)
If the switch is in position II, the fans will be controlled by means of a temperature switch. The fans will become operational automatically, as soon as the fire reaches the correct temperature. This depends on your installation and your heating behaviour and may take an hour in some instances. After the appliance has cooled down, the fans will switch off automatically.
The speed of the fans is controlled by means of a slider on the adapter. In position 1 the fans will run at the lowest speed, in position 4 they will run at the highest speed.
4.6 Fire with central heating connection In the installation/user manual, which is supplied separately with the fire, the operation of the fire with the central heating connection is explained.

Below you will find tips and instructions that are important for a good operation of your fire.
5.1.1 Amount of wood You must observe the recommended volume of wood blocks (number AND dimensions) provided in Appendix 1, Table 2. When a larger volume is used, the heat delivery will increase. In that case, the fire could get overloaded, as a result of which parts could get damaged and/or the walls of the fire will discolour. The glass pane could also blacken sooner. If the fire is burning too hard, you should use coarser/harder wood. Always heat the appliance to capacity. Gross, 1 kg of dry burning wood will supply approx. 4 kWh (kilowatt hour) of energy. For example: for an appliance with a capacity of 4-8 kWh, you must add 1-2 kg of firewood every 45 minutes. The capacity of your fire can be seen in the installation manual in appendix 2 and on the data plate.
!Caution Coniferous or pine wood. This wood should only be used in a well burning fire, because otherwise you will get deposits in the flue duct. It is not really suitable for open fires, because of the sparks. Pine is often used as kindling wood.

!Caution Always be sure to comply with the applicable national and local building regulations related to flue ducts.
Sufficient chimney draught is a pre-condition for a good and safe operation of the fire. The flue duct must comply with the applicable national and local building regulations. When igniting the fire, the flue duct is still cold. This means that there will be little draught. In order to promote draught, more combustion air is supplied at the beginning. This additional air can be achieved by further opening the air supply (see section 5.2). It is also possible to slightly open the door. However, the latter only applies in case of appliances that retrieve air from the room where they are installed. If there is sufficient draught and the fire is burning well, the primary air supply and the door must be closed again. In case of excess draught (> 30-40 Pascal), the flue gases are discharged too quickly, which means that there is too little time to deliver heat. This will affect the efficiency. In order to solve such a problem, it will be better to contact your supplier. If possible, we recommend placing a flue valve to control the draught. These are available at your supplier. By means of this valve, placed in the fire's pipe, you are able to control the draught. When filling the fire, the valve must be placed in the open position in order to prevent smoke blowback.
!Caution Do not burn during misty and/or windless weather. Flue gases could drop down which could cause (smoke) nuisance.
5.4 Ash When burning wood, ash is generated. After many hours of burning, a lot of ash has been created. The ash will provide an insulating layer in your fire. As a result, the combustion temperature will increase and the combustion process will improve. Moreover, an ash layer will protect the fire bottom. This means that you will have to leave the ash layer where it is. Only when the ash layer reaches the top of the ash threshold, you can scoop half the ash (at maximum) out of the fire.
!Tip Make sure there is always at least 2 cm of ash on the fire bottom. This will improve the combustion and protect the fire bottom.

Use the supplied ash scoop (see Appendix 2, Fig. 1).
!Caution Always scoop the ash out of the fire using a sideways motion (from right to left). Never throw the ash directly into the normal waste bin, but put in a steel bucket and place it on an incombustible floor. Even after a few days, the ash can still be glowing. Ash from pure (untreated) and clean wood is a natural product. You can use it as a soil improver. In all other cases, dispose of the ash in the correct way.
!CAUTION Never use a vacuum cleaner to remove the ash from the fire. The dust bag is highly combustible and the ash may
damage the motor.

Dik Geurts fires are made of steel plate. A lot of attention is given to a sound manufacture and careful finish, as a result of which your fire requires little maintenance. The following maintenance tips/instructions contribute to a proper operation of your fire and therefore your comfort of use.
!Tip Slightly open the fire door when you are not burning. This will prevent condensation and possible corrosion.
6.1 Cleaning You can clean your fire whenever you want. Ø Clean the outside of the fire with a soft duster.
!Tip The glass pane cleaning agent is available via your supplier/installer.
!Caution Damages to the paint, resulting from objects that have fallen/been placed against the casing of the fire, are not covered by the warranty.
!Caution Paint is not anti-corrosive; be careful with moisture in and around the fire. The formation of rust or discolouration is not covered by the warranty.
Small damages to the paint you can repair yourself, using the supplied spray can. It will be available via your supplier/installer. If, nevertheless, a rust spot appears on your fire, you can remedy this as follows: Ø Carefully sand the rust spot with steel wool. Ø Then treat this area with the supplied paint. Prior to this, you should check whether the colour indicated on the spray can corresponds with the fire. In case of doubts, please contact your dealer. Ø Make sure the direct vicinity of the fire is covered, because of possible excess spraying.
!Tip In case of damage to the paint, retouch an entire area and not only the damaged spot. This prevents discolourations and spots.
6.3 Baffle plates At the top of the fireplace you will find the so-called flame baffle plates (see Appendix 2, Fig. 9). These plates increase the temperature in the fire and therefore the efficiency.
The flame baffle plates are easily replaced. In case of some fires, the bottom and side wall lining must be removed first. For assembly and disassembly, please see the appliance specific section in the installation manual.

Ø Do not burn the fire with no flame baffle plate. Ø If necessary, replace a broken or poorly fitting plate. It can be ordered via your supplier. Keep the old plate for the dimensions.
!CAUTION The risk of a chimney fire is greater if you burn your fire without a flame baffle plate.
6.4 Doorseal fire The door is sealed with a ceramic strip or a springy stainless steel profile. In case of air leakage, more soot deposits are created on the glass pane. If you establish leakage and your fire is sealed with a ceramic strip, please consult your dealer or expert. In case of a sealing with springy stainless steel, see the description below.
!Caution Check the door sealing at least once a year for leakage. In case of a door with a springy stainless steel profile, space can be created between the profile and the door in due time. You can easily solve this problem yourself. Repair takes place as follows: Ø Open the door. Ø Put the palm of your hand against the edge of the door and press your fingertips against the bottom side of the profile (see Appendix 2, Fig. 11). Ø Press your fingertips towards the palm of your hand in order to make the profile bulge again. Ø Adjust the profile in such a way that the door properly seals again.
!Tip For the maintenance of the other seals, please refer to the installation manual provided.
6.5 Inner lining At the bottom and on the side walls of the fire, heat-resistant plates are placed. These plates reflect the heat, have an insulating effect and protect the steel plate walls of the fire. If cracks are created, for instance due to extreme heat in the fire, this is not a problem. If lining plates are falling away from each other, they should be replaced. For assembly and disassembly, please see the appliance specific installation manual.
!Caution Check the lining plates at least once per year for crack(s).
!Tip Keep the old plate/plates as a reference for the dimensions of the new plate/plates. Ø Remove the broken plate/plates, keep an eye on their order. Ø Place the new plate/plates in reverse order.
!Caution To guarantee the operation of the fire, check whether the holes in the heat-resistant plates correspond.
6.6 Glass pane The fire has glass panes made of heat-resistant ceramic material.
!Caution Very small irregularities in the glass panes cannot be avoided and are within the specified quality standards. The glass pane is attached to the door by means of profiles or lips. After the fire has been burning a few times, a little bit of play may occur at a glass pane. Tighten the nuts or press the clips tight when you notice the glass pane getting a little bit of play. Do not overtighten the nuts, as overtightening will cause breakage. When a glass pane is torn or broken, you must have it replaced. Although the fire has a pane aeration system, there may still be deposits on the pane. Regularly remove any deposits on the glass pane, using the glass pane cleaning agent supplied, as these deposits may burn into the glass and will be difficult to remove.

The glass pane should absolutely not be placed in the glass container, as the ceramic material has a much higher melting temperature than ordinary glass.
6.7 Chimney sweeping The flue duct must be inspected and cleaned by a recognized specialist.
!Tip Keep the invoice, your insurance may ask for it.
6.8 Maintenance of the fan(s) Dust and dirt in the room where the appliance is installed can have a negative effect on the operation of the fans. We therefore recommend cleaning the fans periodically.
!Tip Only perform maintenance after the fire has cooled down completely.

7.1 General Packaging materials must be disposed of in accordance with local regulations.
7.2 Fire At the end of its life span, the fire must be processed in a responsible manner, so that the fire or its parts can be recycled. Ø Do not place the fire with unsorted waste, but submit it at a recognized collection point. Ø Contact your municipality for information on available delivery and collection systems.
7.3 Glass pane Ø A glass pane for a fire is made of heat-resistant ceramic material. A broken ceramic pane must be disposed of as residual waste. The glass pane should absolutely not be placed in the glass container, as the ceramic material has a much higher melting temperature than ordinary glass. When recycled, this will lead to great problems in glass production.
!Caution A fire pane should NOT be placed in the glass container and should be considered as residual waste.
In Table 1 you will find an overview of the malfunctions that might occur, as well as their possible causes and remedies.
!CAUTION Consult your supplier if the table does not supply you with a solution.
For your warranty, you must contact your supplier. The warranty on your Dik Geurts fire is provided via your supplier. In case of complaints, you should always contact him. Your supplier will involve Dik Geurts Haardkachels, if he thinks this is necessary. The factory warranty expires two years after the date of purchase. Consumption materials such as glass pane, seal strip, inner lining plates and the flame baffle plate are not included.

A. Smoky air / smoke
the fire due to underpressure in
supply fresh air; if possible, switch off the
the room where it is installed
cooker hood.
B. Soot deposits on glass
because:
2.1 use smaller kindlings
2.1 kindlings are too big;
2.2 leave the air supply slide fully open for
2.2 primary air supply is closed too
2.3 leave at least 2 cm of ash (3.4)
2.3 there is too little ash on the fire
amount of wood.
C. Soot deposits on the
inside of the fireplace
temporarily opening the primary air supply.
D. Dark smoke
2.1 have the duct inspected.
2.2 allow the fire to burn through better by
opening the primary air supply.
supply fresh air; if possible, switch off the
cooker hood.
E. Discolouration on
amount of wood.
F. Tears in the inner lining
G. Corrosion on the fire
H. handle or hinge is
lubrication.


cm 12
28 22 32 28 28 30 25 28 25 25 30 25 30 25 30 30 30 25 30 28 33 33 28 28 30 28 28 28 20 24 26 28 32 25 33 30 22 25
1 3 1 2 2 1 3 2 1 2 2 2 1 2 1 2 1 1 2 2 2 1 1 2 1 2 3 3
1,0 2,0 1,6 2,2 2,2 1,5 2,6 2,2 1,2 1,1 1,2 1,4 2,0 2,0 2,5 1,2 2,0 2,0 2,5 2,2 1,0 1,0 1,0 1,7 1,7 1,0 1,0 1,4 1,7 1,0 1,0 1,0 1,4 2,6 1,0 1,4 1,7 1,8 2,1 2,0 2,6
Lars 800 Lars 900 Lars 1100 Modivar 5 EA/RS

Tabel / Table / Tabelle / Tableau 3 Tabel / Table / Tabelle / Tableau 3

180°




52c-0079


52c-0077 · 52c-0210

DRU Verwarming B.V. Ratio 8, 6921 RW Duiven Postbus 1021, 6920 BA Duiven Nederland
DRU Belgium Kontichsesteenweg 69/1 Unit A-6 2630 Aartselaar Belgium
Drugasar Ltd. Deans Road, Swinton Manchester M27 0JH United Kingdom
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.