NL
Dik Geurts logo
Officiële handleiding

Dik Geurts Folke

64 pagina's·1.9 MB·Kachel·PDF·ENITJA
Dik Geurts Folke
Inhoudsopgave 24 secties Contents · 1. Introduction · 2. SAFETY · 2.1 General · … TonenVerbergen
Page 2 of the Dik Geurts Folke user manual — 1. Introduction
Pagina 2 · klik om te vergroten
Pagina 2

1. Introduction

Congratulations on your purchase of this Dik Geurts fire. DRU Verwarming, a fire manufacturer, develops and produces products that comply with the highest quality, performance and safety requirements. This will enable you to enjoy using this product for many years to come. This fire is provided with a CE mark. Wood burning fires that comply with the essential requirements for safety, environment and energy consumption, etc. of the European Construction Products Directive, are entitled to carry the CE mark. The Dik Geurts wood burning fire has an ingenious burning system which ensures effective and clean combustion combined with optimum efficiency. The combustion air is regulated by means of the air supply slide. In this user manual you can read how it works. This appliance is supplied with two manuals: the installation manual and the user manual. The user manual will give you the information you need to operate the appliance in a proper, safe and environmentally friendly way. Carefully read this user manual, before you take this fire into operation. The figures can be found in the appendix at the back of this booklet. Keep the user manual AND the installation manual in a safe place. As a user you are only entitled to perform the work described in the user manual. All other work should be performed by a recognized installer. In case of questions or doubts, please contact your supplier. The following symbols are used in the manual to indicate important information: Ø Work to be performed

!Tip Suggestions and recommendations

!Caution These instructions are necessary in order to prevent possible problems during use

!CAUTION You need these instructions to prevent fire, personal injury or other serious damages

Page 3 of the Dik Geurts Folke user manual — 2.1 General
Pagina 3 · klik om te vergroten
Pagina 3

2. SAFETY

2.1 General

  • !CAUTION
  • Carefully read this chapter on safety.
  • Observe the measures / instructions in this manual.

2.2 Precautions / safety instructions Carefully observe the following measures/regulations:

!CAUTION Your fire must be installed by a skilled, recognized installer of wood burning appliances.

!CAUTION Have the fire installed in accordance with the applicable national, local and constructional (installation) regulations.

!Caution The flue duct must be assessed in advance concerning its suitability for the appliance, and should be inspected and/or cleaned by a recognized specialist. Due to the utilisation of new, innovative techniques, the combustion temperature is higher than it was in the past. Have the flue duct inspected and cleaned by a specialist, at least once or twice per year. Only with a good duct, your fire will perform in a safe and faultless way.

!Caution In case of a combustible floor, you must place a fireproof floor plate under the appliance, which will be available at your supplier as an accessory.

!Caution Do not make any changes to the fire yourself.

!Caution Only replace parts by original parts.

!CAUTION Do not perform any work when the fire is still hot, wait at least 24 hours after use.

!Caution Only burn the fire with the recommended fuel (see section 5.1).

!Caution Do not use the fire as a waste incinerator.

!CAUTION The minimum distance between the fireplace/chimney pipes and combustible objects/materials stated on the data

plate should be taken into account.

!CAUTION Do not place combustible materials under the appliance.

!CAUTION Do not allow clothes, towels etc. to dry on and/or near the appliance, in order to prevent fire.

!CAUTION Avoid contact with a burning fire in order to prevent burns and/or clothes catching fire.

!CAUTION During use, the outside of the fire will become very hot. Therefore, you should use the supplied oven glove when

operating the fire.

!CAUTION Never leave children and persons who are unable to judge the consequences of their actions by themselves near a

burning fire.

!CAUTION Avoid working with solvents, glue, PUR foam, etc. in the room during use of the fire.

!Caution The fire is intended as atmospheric heating and is not developed for continuous use as main heating.

!Caution The fire is not suitable for use as a barbecue.

!Caution Make sure that there is an adequate supply of fresh air; if possible, this air may be supplied via an EA/RS connection.

!CAUTION In case of a fire in the chimney, close the air supply, extinguish the wood fire with sand and call the fire brigade.

!Caution Carefully read chapter 3 ‘Taking into operation’, before you start to burn.

Page 4 of the Dik Geurts Folke user manual — 2.3 The Clean Air Act 1993 and Smoke Control Areas
Pagina 4 · klik om te vergroten
Pagina 4

2.3 The Clean Air Act 1993 and Smoke Control Areas

2.3.1 Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area).

In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the Environment respectively.

Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/smoke-control-area-rules

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements.

The Dik Geurts Instyle 400, 500, 550, 600, 650 and 700, Dik Geurts Instyle Corner Slim 660/495, Dik Geurts Prostyle 500, 550, 600, 650 and 700, Dik Geurts Keld 5 LowEA and Keld 5 HighEA, Dik Geurts Ivar 5 LowEA and Ivar 5 HighEA, Dik Geurts Jannik Medium LowEA, Dik Geurts Aste 5 LowEA/RS, Dik Geurts Odin FrontEA, Dik Geurts Ivar 5 storeEA, Dik Geurts Ivar 8 StoreEA, Dik Geurts Ivar 8 LowEA wood burning stove , Dik Geurts Modivar 5 EA/RS and OlafEA wood burning stove have been recommended as suitable for use in smoke control areas when burning wood logs.

The Ivar 8 StoreEA and Ivar 8 LowEA wood burning stove must be fitted with a permanent stop to prevent closure of the primary air control beyond the 6.0cm open position. OlafEA wood burning stove must be fitted with a permanent stop to prevent closure of the primary air control beyond the 5.3cm open position.

Exemption details can be found at: https://smokecontrol.defra.gov.uk/appliances.php Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/smoke-control-area-rules

2.3.2 Exempt appliances Exempt appliances are appliances (ovens, wood burners and stoves) which have been exempted by Statutory Instruments (Orders) under the Clean Air Act 1993 or Clean Air (Northern Ireland) Order 1981. These have passed tests to confirm that they are capable of burning an unauthorised or inherently smoky solid fuel without emitting smoke.

Appliances which are authorized for use in Smoke Control Areas: http://smokecontrol.defra.gov.uk/appliances.php

Page 5 of the Dik Geurts Folke user manual — 2.4 HETAS
Pagina 5 · klik om te vergroten
Pagina 5

2.4 HETAS

  • 2.4.1 Warning note on fume emission Properly installed, operated and maintained this appliance will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, the following immediate actions should be taken:
  • Open doors and windows to ventilate room.
  • Let the fire out or eject and safely dispose of fuel from the appliance.
  • Check for flue or chimney blockage, and clean if required. Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek expert advice.

2.4.2 Extractor fan There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room.

2.4.3 Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air. This air vent should not under any circumstances be shut off or sealed.

2.4.4 Chimney cleaning The chimney should be swept at least twice a year. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period. If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove.

2.4.5 Periods of prolonged non-use If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open.

2.4.6 Use of fireguard When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 8423:2002 (Replaces BS 6539).

2.4.7 Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use.

2.4.8 Aerosol sprays Do not use an aerosol spray on or near the stove when it is alight.

2.4.9 CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions given under “Warning Note” above.

Page 6 of the Dik Geurts Folke user manual — 3. Taking into operation
Pagina 6 · klik om te vergroten
Pagina 6

3. Taking into operation

  • 3.1 For the first time Prior to taking the fire into operation for the first time, please observe the following:
  • The outside of the fire must be clean. If necessary, clean it first with a duster. Contaminations on the fire such as (building) dust, grit, residues of packaging material and stickers can result in odour and singing hazards or burns in the paint of the glass pane. Remove fingerprints from the glass pane with a window cleaning agent.
  • The paint of the fire has not yet hardened. Hardening will take place when burning the fire for the first time. The paint will first become soft before it starts to harden. Until that moment the paint is easily damaged. Hardening takes place with an unpleasant odour and the generation of white smoke, resulting from the evaporation of volatile components. Burn the fire (see chapter 5) properly for a few hours so that the paint really hardens.
  • The fire will only start to burn really well after it has been burning a few times. The first few times the glass pane will steam up a little bit more due to the evaporation of various materials and the lower combustion temperature. This lower temperature is caused by the fact that insufficient ash has been created.

!Tip Touch up any damages to the paint before taking the fire into operation for the first time. This will prevent colour variations.

!Tip Do not touch the fire during hardening in order to prevent damaging the paint.

!Caution Vent the room properly because of the evaporation of heat resistant paint.

!CAUTION Remove pets from the room because of the released vapours when hardening the paint.

3.2 Fastening the cold (door) handle If your appliance is provided with a stainless steel, detachable (door) handle (see Appendix 2, Fig. 2), you will also be able to fasten it.

To do this proceed as follows: Ø Open the door. Ø Place the stainless steel handle in the correct position in the door (see Appendix 2, Fig. 2). Ø Rotate the (door) handle in such a way, that the head of the adjusting screw points in your direction. Ø Use an Allen key to fasten the adjusting screw (be careful, overtightening will cause breakage). Now the (door) handle is locked to the door.

If you want to disassemble the (door) handle you should perform the above-mentioned steps in opposite order.

3.3 Protection In order to prevent unsafe situations, you must carefully observe the following measures/instructions.

  • !CAUTION
  • The minimum distance between the fireplace/chimney pipes and combustible objects/materials stated on the data plate should be taken into account;
  • Do not place combustible materials under the appliance;
  • Do not dry clothes, towels, etc. on or near the fire in order to prevent fire;
  • Avoid contact with a burning fire in order to prevent burns and/or clothes catching fire;
  • When operating the fire, always wear the supplied glove;
  • Do not leave children and persons who are unable to judge the consequences of their actions by themselves near a burning fire;
  • Avoid working with solvents, glue, PUR foam, etc. in the room where the burning fire is installed.

3.4 Discolouration of walls and ceilings A brown discolouration is annoying and it is a problem that is difficult to solve. Brown discolouration can be caused by the combustion of dust as a result of the materials used, too little ventilation, smoking, the burning of candles, oil lights, etc. Smoke from cigarettes and cigars contains tar substances that can be deposited on colder and/or moist walls.

  • !Tip
  • These problems can be (partly) prevented by installing a good ventilation in the room where the fire is installed.
  • Use as little candles and oil lights as possible and keep the taper as short as possible. Burning candles, oil lights, cigarettes, cigars, etc. creates a considerable amount of contaminating soot and tar particles in your house.
Page 7 of the Dik Geurts Folke user manual — 4. Lighting and burning
Pagina 7 · klik om te vergroten
Pagina 7

4. Lighting and burning

4.1 Instructions Observe the following instructions for a good and safe operation of your fire:

!CAUTION Have your flue duct checked by a recognized specialist for blockage and contamination if you have not burned the

fire for some time.

  • !CAUTION
  • Have the flue duct inspected and cleaned by a specialist at least once or twice per year. The flue duct must be clean and function properly for your fire to be used safely and without any problems.
  • use the right fuel only (see section 5.1);
  • observe the maximum amount of wood blocks as stated in Appendix 1, Tabel 2;
  • make sure that sufficient fresh air is supplied (see section 5.2);
  • in case of a fire in the chimney, close the air supply, extinguish the wood fire with sand and call the fire brigade;
  • never extinguish the wood fire with water;
  • do not clean the fire with a vacuum cleaner (see section 5.4).
  • !Caution
  • preferably, do not burn the fire during misty and/or windless weather in order to prevent (smoke) nuisance;
  • burn a fire with the door closed. It is only opened to fill additional wood;
  • a properly heated flue duct is necessary for the draught in the duct;
  • a high combustion temperature will keep the flue duct clean.

4.2 Lighting Observe the following steps for lighting and burning your fire: Ø If necessary, remove a part of the ash with the supplied ash scoop (see section 5.4). Ø If necessary, clean the glass pane (see section 6.6). Ø If applicable, open the flue valve. Ø Fully open the air supply using the air supply slide (with indication closed/open, see Appendix 2, Fig. 3a and 3b); Ø Place 2 small wood blocks in the combustion chamber, lengthwise (see Appendix 2, Fig. 4); Ø Stack kindlings crosswise on the 2 wood blocks and place a firelighter on top of it (see Appendix 2, Fig. 5). Ø Make sure that sufficient air is able to flow through the stack of wood, so that the wood will easily ignite. Ø Light the firelighter and, if applicable, a ball of paper. Ø Close the fire door, it may be left open a little bit, if necessary, until the kindlings have caught fire. Ø Allow the fire to burn through properly in order to heat up the flue duct. In this way, a good draught is created. Ø To keep the glass pane clean, allow the fire to burn hot until it burns out.

  • !Caution
  • do not place a wood block diagonal in front of the air supply;
  • do not start with large wood blocks, build up the fire calmly;

4.3 Burning Ø Allow the fire to continue burning on small wood blocks until a properly burning fire is created with a glowing ember bed. Ø In case of a wide fire: now distribute the glowing fire bed over the fire's width and place a few more small wood blocks on top of it. Ø Control the output with the air supply slide only after approx. 15-20 minutes when there is a properly burning fire with ember bed. Simply allow the appliance to continue burning using the air supply slide. Ø Then fill the fire with larger wood blocks (see table 2 in Appendix 1 for the amount) after the small wood blocks have been burnt for a large part. If necessary, further open the air supply slide for a moment, to allow the fire to burn properly again.

!CAUTION Make sure that wood blocks do not fall/lie against the glass pane.

!CAUTION For good combustion and optimal ease of use, always heat the appliance to capacity.

  • !Tip
  • Carefully pace the wood blocks in the fire in order to prevent the inner lining from getting damaged. Be particularly cautious in case of wood stems with side branches;
  • Place the wood blocks loosely on top of each other and make sure they can be reached by sufficient air;
  • If the fire is not burning properly, you can temporarily open the air supply slide further;
  • Do not only use soft wood, but mix it with hard wood in particular.
Page 8 of the Dik Geurts Folke user manual — 4. Lighting and burning
Pagina 8 · klik om te vergroten
Pagina 8

!Tip A steadily burning fire stimulates combustion.

Ø Refill the fire before the flames have gone out of the fire. This will be approximately every 30 to 45 minutes. Ø Close the door and open the air supply slide all the way until the new wood blocks are burning well. See Table 2 for the recommended quantities of wood. Ø Using the air supply slide, adjust the draught until a steady flame pattern is achieved. Ø Always allow the fire to burn empty when you stop burning. Smoke Light coloured (white or colourless) smoke indicates that suitable wood is used and that there is a good combustion. Grey, blue or even black smoke is created in case of incomplete combustion, e.g. as a result of moist or excess wood.

4.4 Fire with oven (if applicable) If your fire is provided with an oven, you can use it to heat or cook dishes.

You can close the oven, using the valve (see Appendix 2, Fig. 6 (K)). You will usually suspend it at the side of the fire, because air for glass pane aeration is supplied by the oven. Use the oven glove for this. When used, you must always place aluminium foil in the oven in order to avoid fat from getting on the oven surface and burning into it. Only use the oven after the fire's paint has hardened (see section 4.1).

4.5 Fire with fan(s) Appliances that are made with fans will heat a room more quickly and increase comfort. As soon as the fan is switched on you will be able to feel a pleasant warm air flow.

4.5.1 How the fan(s) work The fans are operated by means of the switch on the appliance.

We distinguish three positions (see Appendix 2, Fig. 8): Position I – ON (the fans are running, irrespective of the fire's temperature) Position O – OFF (the fans are off) Position II – AUTO (the fans will only run when the fire has reached the required temperature)

If the switch is in position II, the fans will be controlled by means of a temperature switch. The fans will become operational automatically, as soon as the fire reaches the correct temperature. This depends on your installation and your heating behaviour and may take an hour in some instances. After the appliance has cooled down, the fans will switch off automatically.

The speed of the fans is controlled by means of a slider on the adapter. In position 1 the fans will run at the lowest speed, in position 4 they will run at the highest speed.

4.6 Fire with central heating connection In the installation/user manual, which is supplied separately with the fire, the operation of the fire with the central heating connection is explained.

Page 9 of the Dik Geurts Folke user manual — 5. Burning instructions and tips
Pagina 9 · klik om te vergroten
Pagina 9

5. Burning instructions and tips

Below you will find tips and instructions that are important for a good operation of your fire.

  • 5.1 Fuel Good fuel is the ‘engine’ of your fire. You will benefit the most from your fire, if you burn it with high quality, well dried wood or wood briquettes. In this way you will prevent unwanted additional effects like excess smoke formation as a result of poor combustion, insufficient heat yield and poor efficiency. The fire is only suitable to be filled with clean wood or wood briquettes. Wood is usually purchased in cubic metres. However, there are many types of ‘cubes’ available on the market:
  • A genuine cube (neatly stacked sawn and split wood): 1.0 m 3 (approx. 700 kg).
  • A bulk cube (wood loaded in 1 m3 trays): 0.6 m 3 (approx. 400 kg).
  • A stere (neatly stacked one metre sections): 1.3 m 3 (approx. 900 kg). Dry wood Wood must be properly dry. Freshly felled wood is not suitable, as it contains too much moist (approx. 60%). Oven-dried wood, on the other hand, is suitable. Therefore, you should allow the wood to dry for at least one year, and preferably for two to three years. The wood will dry if you store it outside under a lean-to (i.e. not in the garage), preferably in a sunny location. This will allow the wind (but not the rain) to get to it. Short, split stems will dry the quickest. After drying, they only contain 15 to 20% moist and will provide the highest output.
  • !Tip Dry wood will generate a bright sound when you hit two blocks together. At the front side there will be shrinkage cracks and the bark will come loose easily. We recommend using a moisture gauge to measure the moist percentage of the burning wood. It will be available at your supplier. In order to determine the moist percentage correctly, please pay attention to the following:
  • First allow the burning wood to reach room temperature.
  • Always measure in the core of the wood block.
  • This is why you should always cleave a wood block through the middle first.
  • Press the moisture gauge's measuring pinsdiagonally on the grain,uprightandfirmly in the middle of the freshly cleaved surface. There is no point in measuring at the cross-cut of the wood or parallel to the grain.
  • The measurement provides an indication. In order to get a more accurate picture, the measurement should be repeated on several places (and perhaps on various wood blocks).
  • The burning wood may have a maximum moist percentage of 20%. If the wood is too dry, i.e. below a moist percentage of 10%, it will quickly gasify and overloading could occur, particularly in the case of lighter wood types.

5.1.1 Amount of wood You must observe the recommended volume of wood blocks (number AND dimensions) provided in Appendix 1, Table 2. When a larger volume is used, the heat delivery will increase. In that case, the fire could get overloaded, as a result of which parts could get damaged and/or the walls of the fire will discolour. The glass pane could also blacken sooner. If the fire is burning too hard, you should use coarser/harder wood. Always heat the appliance to capacity. Gross, 1 kg of dry burning wood will supply approx. 4 kWh (kilowatt hour) of energy. For example: for an appliance with a capacity of 4-8 kWh, you must add 1-2 kg of firewood every 45 minutes. The capacity of your fire can be seen in the installation manual in appendix 2 and on the data plate.

  • 5.1.2 Suitable types of wood The following types of wood are recommended for burning your fire:
  • Hard types of wood such as oak, beech, hornbeam, ash and fruit tree wood. These types of wood generate a short flame and will burn longer.
  • Light types of wood such as birch, poplar, willow and alder. These types generate a long flame but burn up rather quickly.
  • Wood briquettes (compressed wood chips) are not to be burnt in a smoke control area.

!Caution Coniferous or pine wood. This wood should only be used in a well burning fire, because otherwise you will get deposits in the flue duct. It is not really suitable for open fires, because of the sparks. Pine is often used as kindling wood.

Page 10 of the Dik Geurts Folke user manual — 5.3 Flue duct
Pagina 10 · klik om te vergroten
Pagina 10
  • 5.1.3 Unsuitable fuel The materials stated below are not suitable for your fire. Therefore, you should never use:
  • Wet or fresh wood,as it contains moist (at least 20%). It will be very hard to ignite your fire with this wood and it provides little heat.
  • Painted, stained or impregnated wood. The chemicals are bad for the environment and will affect the glass pane and inner lining as well.
  • Plywood and chipboard.
  • Types of coal such a anthracite, cokes or ovoids. These are only suitable for burning a coal fire.
  • Printed (coloured) paper from magazines and newspapers. You can use a ball of paper to ignite the fire.
  • Combustible fluids. These may also not be used to ignite the fire.
  • Plastic, textile and other waste materials. A ‘multi-burner’ for any material does not exist!

5.2 Ventilation

  • !Caution
  • Observe the applicable national, local and constructional regulations in relation to ventilation and air supply.
  • Make sure there is sufficient combustion air. Combustion requires air. A wood fire will use approximately 35-50 m 3 of air per hour, an open fire 150-200 m 3 . There are appliances that retrieve the combustion air from the room where the appliance is installed, as well as appliances that are able to have an outdoor air connection. This is stated in the technical data of the Installation Manual. The lack of fresh air in houses with a mechanical air extraction system and/or when a cooker hood is used in an open kitchen, may create underpressure in your room. As a cooker hood is able to extract 600 to 1000 m 3 of air per hour. In those cases, there is a risk that harmful flue gases from the fire flow into the room (smoke blowback). Moreover, the fire will not work well, if the combustion air has to come from the room where the fire is installed. In this situation, we recommend placing a fire with outdoor air connection. The combustion air is supplied from outside, by means of a tube. In case of an appliance that retrieves its combustion air from the room where it is installed, the supply of fresh air is very important. You can supply fresh air by opening a skylight or leaving a window/door slightly open.

5.3 Flue duct

!Caution Always be sure to comply with the applicable national and local building regulations related to flue ducts.

Sufficient chimney draught is a pre-condition for a good and safe operation of the fire. The flue duct must comply with the applicable national and local building regulations. When igniting the fire, the flue duct is still cold. This means that there will be little draught. In order to promote draught, more combustion air is supplied at the beginning. This additional air can be achieved by further opening the air supply (see section 5.2). It is also possible to slightly open the door. However, the latter only applies in case of appliances that retrieve air from the room where they are installed. If there is sufficient draught and the fire is burning well, the primary air supply and the door must be closed again. In case of excess draught (> 30-40 Pascal), the flue gases are discharged too quickly, which means that there is too little time to deliver heat. This will affect the efficiency. In order to solve such a problem, it will be better to contact your supplier. If possible, we recommend placing a flue valve to control the draught. These are available at your supplier. By means of this valve, placed in the fire's pipe, you are able to control the draught. When filling the fire, the valve must be placed in the open position in order to prevent smoke blowback.

!Caution Do not burn during misty and/or windless weather. Flue gases could drop down which could cause (smoke) nuisance.

5.4 Ash When burning wood, ash is generated. After many hours of burning, a lot of ash has been created. The ash will provide an insulating layer in your fire. As a result, the combustion temperature will increase and the combustion process will improve. Moreover, an ash layer will protect the fire bottom. This means that you will have to leave the ash layer where it is. Only when the ash layer reaches the top of the ash threshold, you can scoop half the ash (at maximum) out of the fire.

!Tip Make sure there is always at least 2 cm of ash on the fire bottom. This will improve the combustion and protect the fire bottom.

Page 11 of the Dik Geurts Folke user manual — 5.2 Ventilation
Pagina 11 · klik om te vergroten
Pagina 11

Use the supplied ash scoop (see Appendix 2, Fig. 1).

!Caution Always scoop the ash out of the fire using a sideways motion (from right to left). Never throw the ash directly into the normal waste bin, but put in a steel bucket and place it on an incombustible floor. Even after a few days, the ash can still be glowing. Ash from pure (untreated) and clean wood is a natural product. You can use it as a soil improver. In all other cases, dispose of the ash in the correct way.

!CAUTION Never use a vacuum cleaner to remove the ash from the fire. The dust bag is highly combustible and the ash may

damage the motor.

Page 12 of the Dik Geurts Folke user manual — 6.2 Paint
Pagina 12 · klik om te vergroten
Pagina 12

6. Maintenance

Dik Geurts fires are made of steel plate. A lot of attention is given to a sound manufacture and careful finish, as a result of which your fire requires little maintenance. The following maintenance tips/instructions contribute to a proper operation of your fire and therefore your comfort of use.

  • !CAUTION
  • perform maintenance after the fire has been out of operation for at least 24 hours;
  • do not make any changes to the fire yourself;
  • as a user you are only allowed to perform the maintenance stated in this chapter, for any other work you will have to consult an installer who has experience in the field of wood fire heating;
  • only replace parts by original parts. These are available via your supplier/installer.

!Tip Slightly open the fire door when you are not burning. This will prevent condensation and possible corrosion.

6.1 Cleaning You can clean your fire whenever you want. Ø Clean the outside of the fire with a soft duster.

  • !Caution
  • do not use corrosive or abrasive cleaning agents when cleaning your fire and/or glass pane, in order to prevent damage;
  • do not use water when cleaning, as the heat-resistant paint is not water repellent. Water may cause rust spots;
  • do not put glasses, cups, etc. on the fire. Rings may cause rust spots. Ø Remove any deposits on the glass pane using the supplied glass pane cleaning agent. For this, observe the user manual on the packaging (see section 6.6).

!Tip The glass pane cleaning agent is available via your supplier/installer.

6.2 Paint

!Caution Damages to the paint, resulting from objects that have fallen/been placed against the casing of the fire, are not covered by the warranty.

!Caution Paint is not anti-corrosive; be careful with moisture in and around the fire. The formation of rust or discolouration is not covered by the warranty.

Small damages to the paint you can repair yourself, using the supplied spray can. It will be available via your supplier/installer. If, nevertheless, a rust spot appears on your fire, you can remedy this as follows: Ø Carefully sand the rust spot with steel wool. Ø Then treat this area with the supplied paint. Prior to this, you should check whether the colour indicated on the spray can corresponds with the fire. In case of doubts, please contact your dealer. Ø Make sure the direct vicinity of the fire is covered, because of possible excess spraying.

!Tip In case of damage to the paint, retouch an entire area and not only the damaged spot. This prevents discolourations and spots.

6.3 Baffle plates At the top of the fireplace you will find the so-called flame baffle plates (see Appendix 2, Fig. 9). These plates increase the temperature in the fire and therefore the efficiency.

The flame baffle plates are easily replaced. In case of some fires, the bottom and side wall lining must be removed first. For assembly and disassembly, please see the appliance specific section in the installation manual.

  • !CAUTION
  • in case of collisions, the plate might break. When chimney sweeping, check the baffle plates for crack(s);
  • when chimney sweeping, remove the baffle plates. Mark them so they can be returned at the same location.
  • when placing them back, check whether the baffle plates still fit properly in their intended profiles;
  • in case of excess condensation in the chimney, the flame baffle plate can become saturated with moisture and therefore easily break. Consult your dealer/installer for a solution, if this problem occurs.
Page 13 of the Dik Geurts Folke user manual — 6. Maintenance
Pagina 13 · klik om te vergroten
Pagina 13

Ø Do not burn the fire with no flame baffle plate. Ø If necessary, replace a broken or poorly fitting plate. It can be ordered via your supplier. Keep the old plate for the dimensions.

!CAUTION The risk of a chimney fire is greater if you burn your fire without a flame baffle plate.

6.4 Doorseal fire The door is sealed with a ceramic strip or a springy stainless steel profile. In case of air leakage, more soot deposits are created on the glass pane. If you establish leakage and your fire is sealed with a ceramic strip, please consult your dealer or expert. In case of a sealing with springy stainless steel, see the description below.

!Caution Check the door sealing at least once a year for leakage. In case of a door with a springy stainless steel profile, space can be created between the profile and the door in due time. You can easily solve this problem yourself. Repair takes place as follows: Ø Open the door. Ø Put the palm of your hand against the edge of the door and press your fingertips against the bottom side of the profile (see Appendix 2, Fig. 11). Ø Press your fingertips towards the palm of your hand in order to make the profile bulge again. Ø Adjust the profile in such a way that the door properly seals again.

!Tip For the maintenance of the other seals, please refer to the installation manual provided.

6.5 Inner lining At the bottom and on the side walls of the fire, heat-resistant plates are placed. These plates reflect the heat, have an insulating effect and protect the steel plate walls of the fire. If cracks are created, for instance due to extreme heat in the fire, this is not a problem. If lining plates are falling away from each other, they should be replaced. For assembly and disassembly, please see the appliance specific installation manual.

!Caution Check the lining plates at least once per year for crack(s).

!Tip Keep the old plate/plates as a reference for the dimensions of the new plate/plates. Ø Remove the broken plate/plates, keep an eye on their order. Ø Place the new plate/plates in reverse order.

  • !Tip
  • Mark the heat-resistant plates so that they can be replaced correctly (in the same location and orientation).
  • Always heat the appliance to capacity using suitable, dry wood. Always leave a minimum layer of ash on the floor of the appliance. This lengthens the service life of the appliance's inner lining.

!Caution To guarantee the operation of the fire, check whether the holes in the heat-resistant plates correspond.

6.6 Glass pane The fire has glass panes made of heat-resistant ceramic material.

!Caution Very small irregularities in the glass panes cannot be avoided and are within the specified quality standards. The glass pane is attached to the door by means of profiles or lips. After the fire has been burning a few times, a little bit of play may occur at a glass pane. Tighten the nuts or press the clips tight when you notice the glass pane getting a little bit of play. Do not overtighten the nuts, as overtightening will cause breakage. When a glass pane is torn or broken, you must have it replaced. Although the fire has a pane aeration system, there may still be deposits on the pane. Regularly remove any deposits on the glass pane, using the glass pane cleaning agent supplied, as these deposits may burn into the glass and will be difficult to remove.

  • !Caution
  • Regularly check the glass pane for cracks/tears.
  • Do not use corrosive and/or abrasive cleaning agents to clean the glass pane.
Page 14 of the Dik Geurts Folke user manual — 6. Maintenance
Pagina 14 · klik om te vergroten
Pagina 14
  • !Tip
  • Do not overtighten the nuts that are used to fix the glass pane, as overtightening will cause breakage;
  • A broken ceramic pane must be disposed of with the regular domestic waste (see section 8.3).
  • To clean the glass pane, you may also use ceramic hob cleaner or copper cleaner.

The glass pane should absolutely not be placed in the glass container, as the ceramic material has a much higher melting temperature than ordinary glass.

6.7 Chimney sweeping The flue duct must be inspected and cleaned by a recognized specialist.

  • !Caution
  • in case of normal use (1 to 2 times per week) you must have the flue duct inspected and cleaned once per year;
  • in case of (more) frequent use, you should have your flue duct inspected/cleaned more often (2 to 3 times per year);
  • have the flue duct checked for blockage if you have not burned your fire for a long time.

!Tip Keep the invoice, your insurance may ask for it.

6.8 Maintenance of the fan(s) Dust and dirt in the room where the appliance is installed can have a negative effect on the operation of the fans. We therefore recommend cleaning the fans periodically.

  • To do this proceed as follows:
  • Disconnect the adapter from the wall socket.
  • Open the door.
  • Remove the upper screws that are used to mount the grates (see appendix 2, fig. 8)
  • Remove grates.
  • Carefully clean the fan blades using a vacuum cleaner and a dry cloth/brush. Consult your supplier if the fan is not working as desired.

!Tip Only perform maintenance after the fire has cooled down completely.

Page 15 of the Dik Geurts Folke user manual — 9. Warranty
Pagina 15 · klik om te vergroten
Pagina 15

7. Environment

7.1 General Packaging materials must be disposed of in accordance with local regulations.

7.2 Fire At the end of its life span, the fire must be processed in a responsible manner, so that the fire or its parts can be recycled. Ø Do not place the fire with unsorted waste, but submit it at a recognized collection point. Ø Contact your municipality for information on available delivery and collection systems.

7.3 Glass pane Ø A glass pane for a fire is made of heat-resistant ceramic material. A broken ceramic pane must be disposed of as residual waste. The glass pane should absolutely not be placed in the glass container, as the ceramic material has a much higher melting temperature than ordinary glass. When recycled, this will lead to great problems in glass production.

!Caution A fire pane should NOT be placed in the glass container and should be considered as residual waste.

8. Malfunctions

In Table 1 you will find an overview of the malfunctions that might occur, as well as their possible causes and remedies.

!CAUTION Consult your supplier if the table does not supply you with a solution.

9. Warranty

For your warranty, you must contact your supplier. The warranty on your Dik Geurts fire is provided via your supplier. In case of complaints, you should always contact him. Your supplier will involve Dik Geurts Haardkachels, if he thinks this is necessary. The factory warranty expires two years after the date of purchase. Consumption materials such as glass pane, seal strip, inner lining plates and the flame baffle plate are not included.

Page 16 of the Dik Geurts Folke user manual — Table 1: Diagnosis of malfunctions
Pagina 16 · klik om te vergroten
Pagina 16

Table 1: Diagnosis of malfunctions

A. Smoky air / smoke

1. Smoke / smoky air coming from
1. Open a skylight or slightly open a window to

the fire due to underpressure in

supply fresh air; if possible, switch off the

the room where it is installed

cooker hood.

2. Poorly functioning flue duct
2. Have the flue duct inspected/cleaned

B. Soot deposits on glass

1. Moist wood.
1. Use properly dried wood (3.1)
2. Burning with too low efficiency,
2. Allow the fire to burn through better:

because:

2.1 use smaller kindlings

2.1 kindlings are too big;

2.2 leave the air supply slide fully open for

2.2 primary air supply is closed too

2.3 leave at least 2 cm of ash (3.4)

2.3 there is too little ash on the fire

3. See Tabel 2 for using the recommended

amount of wood.

3. load is too large

C. Soot deposits on the

1. Incomplete combustion
1. Allow the fire to burn through better by

inside of the fireplace

temporarily opening the primary air supply.

D. Dark smoke

1. Moist wood.
1. Use properly dried wood (3.1)
2. Poorly draughting flue duct

2.1 have the duct inspected.

3. Too little air supply

2.2 allow the fire to burn through better by

opening the primary air supply.

3. open a skylight or slightly open a window to

supply fresh air; if possible, switch off the

cooker hood.

E. Discolouration on

1. Overload by exceeding max.
1. See Tabel 2 for using the recommended

amount of wood.

F. Tears in the inner lining

1. No ash on fire bottom
1. Leave at least 2 cm of ash (3.4)
2. Overload fire
2. See Table 2 for using the recommended
3. Inaccurate filling
3. Fill with sufficient care

G. Corrosion on the fire

1. Leakage/condensation chimney
1. Check chimney
2. Wet cloth used during
2. Lightly sand and spray (see section 6.2)

H. handle or hinge is

1. Too little lubrication
1. Grease rotating parts with teflon dry-film

lubrication.

Show 13 more labels / short text on this page
Possible cause · Problem · Remedy · blowback · pane · longer · quickly · bottom · outside of fire · amount of wood · amount of wood · maintenance · running stiffly
Page 17 of the Dik Geurts Folke user manual — Bijlage / Appendix / Anlage / Annexe
Pagina 17 · klik om te vergroten
Pagina 17

Bijlage / Appendix / Anlage / Annexe

Dik Geurts Folke — Bijlage / Appendix / Anlage / Annexe diagram (page 17)
Afb. 1 · Bijlage / Appendix / Anlage / Annexe

cm 12

28 22 32 28 28 30 25 28 25 25 30 25 30 25 30 30 30 25 30 28 33 33 28 28 30 28 28 28 20 24 26 28 32 25 33 30 22 25

1 3 1 2 2 1 3 2 1 2 2 2 1 2 1 2 1 1 2 2 2 1 1 2 1 2 3 3

1,0 2,0 1,6 2,2 2,2 1,5 2,6 2,2 1,2 1,1 1,2 1,4 2,0 2,0 2,5 1,2 2,0 2,0 2,5 2,2 1,0 1,0 1,0 1,7 1,7 1,0 1,0 1,4 1,7 1,0 1,0 1,0 1,4 2,6 1,0 1,4 1,7 1,8 2,1 2,0 2,6

Lars 800 Lars 900 Lars 1100 Modivar 5 EA/RS

Dik Geurts Folke — Bijlage / Appendix / Anlage / Annexe diagram (page 17)
Afb. 2 · Bijlage / Appendix / Anlage / Annexe

Tabel / Table / Tabelle / Tableau 3 Tabel / Table / Tabelle / Tableau 3

Page 18 of the Dik Geurts Folke user manual — Bijlage / Appendix / Anlage / Annexe / Allegato 2
Pagina 18 · klik om te vergroten
Pagina 18

Bijlage / Appendix / Anlage / Annexe / Allegato 2

180°

Show 6 more labels / short text on this page
1a 1b · 52c-0207 · 52c-0206 · 52c-0121 · 3a 3b · 52c-0208 52c-0209
Page 19 of the Dik Geurts Folke user manual — DG-P-12005
Pagina 19 · klik om te vergroten
Pagina 19
Dik Geurts Folke — DG-P-12001 diagram (page 19)
Afb. 3

DG-P-12001

Dik Geurts Folke — DG-P-12001 diagram (page 19)
Afb. 4

DG-P-12003

Dik Geurts Folke — DG-P-12003 diagram (page 19)
Afb. 5

K

DG-P-12005

52c-0079

Page 20 of the Dik Geurts Folke user manual — DG-P-12009
Pagina 20 · klik om te vergroten
Pagina 20
Dik Geurts Folke — DG-P-12009 diagram (page 20)
Afb. 6

DG-P-12009

52c-0077 · 52c-0210

Page 21 of the Dik Geurts Folke user manual — DG-P-12009
Pagina 21 · klik om te vergroten
Pagina 21

DRU Verwarming B.V. Ratio 8, 6921 RW Duiven Postbus 1021, 6920 BA Duiven Nederland

DRU Belgium Kontichsesteenweg 69/1 Unit A-6 2630 Aartselaar Belgium

Drugasar Ltd. Deans Road, Swinton Manchester M27 0JH United Kingdom

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Dik Geurts Folke

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Dik Geurts Folke

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Dik Geurts Folke handleiding-pdf

64 pagina's·1.9 MB·Kachel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…