Dometic FreshLight Explanation of symbols
11 Maintenance of the roof air conditioner 62
12 Troubleshooting 63
13 Warranty 64
14 Disposal 64
15 Technical data 66
!
required action is described step-by-step.
✓This symbol describes the result of an action.
fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.

Safety instructions Dometic FreshLight
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and excess
Alterations to the product without express permission from the
Use for purposes other than those described in the operating manual
In particular, the manufacturer will not be liable for any consequential dam- age, especially consequential damage caused by failure of the roof air con- ditioner.
Electrical devices are not toys.
Keep electrical appliances out of reach of children or infirm persons. Do not let them use the appliances without supervision.
Persons (including children) whose physical, sensory or mental
capabilities or whose lack of experience and knowledge prevent them from using the device safely should not use it without supervision or instruction by a responsible person.
Only use the device as intended.
Do not make any alterations or conversions to the device.
Installation, maintenance and repairs of the roof air conditioner
may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the service centre in your country (addresses on the back page).

Dometic FreshLight Safety instructions
Do not use the roof air conditioner near flammable fluids or in
closed rooms.
Make sure no combustible objects are stored or installed near
the air outlet. A distance of at least 50 cm must be kept.
Do not reach into air outlets or insert any foreign objects in the
roof air conditioner.
Do not undo the upper cover of the roof air conditioner in the
event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires. A
Never drive through automatic car washes when the roof air
conditioner is mounted.
Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height entered in your vehicle documents needs to be altered (increased height 210 mm).
If faults occur in the roof air conditioner's refrigerant circuit, the
roof air conditioner must be checked by a specialist company and properly repaired. The refrigerant must never be released into the air.
Always disconnect the power supply when working on the
Do not operate the roof air conditioner if the ambient
temperature is below 0 °C. There is a risk of damage from freezing condensation.
The roof air conditioner is not suitable for use in agricultural or
construction vehicles.
Operate the device only if you are certain that the housing and
the cables are undamaged.

Target group for this manual Dometic FreshLight
This operating manual is for the user of the roof air conditioner.
Dometic FreshLight 1600 roof air conditioner 9102900207
Dometic FreshLight 2200 roof air conditioner 9102900165
Available as an option (not included in scope of delivery):
WAECO DC extension kit DC-Kit-2 9100300001
WAECO DC extension kit DC-Kit-3 9100300002

Dometic FreshLight Intended use
The Dometic FreshLight roof air conditioner with integrated roof window can condition the interior of campers and caravans with cool or warm air.
The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work proper- ly if exposed to strong vibrations.
The operating mode of the roof air conditioner is guaranteed for temperature up to 52 °C.
Do not operate the roof air conditioner in the “Heating” air conditioning mode if the room temperature is above 30 °C.
Heating operation is recommended at ambient temperatures of +2 °C and above.
The roof air conditioner with integrated window supplies the interior with cool or warm dehumidified air without dust and dirt. Used air can be extracted from the interior with a blower.
Two dimmable LED lamps integrated in the air outlet unit provide pleasant lighting.
The roof window has two blinds: the blackout roller blind lets no light through, while the sun protection blind protects from direct sunlight.
NOTE The roof air conditioner can lower or raise the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your roof air conditioner. Below an outer temperature of 16 °C the roof air conditioner does not cool anymore. In this case only use the air conditioning mode “Circulating air”.
When the outside temperature drops, the heating capacity of the roof air con- ditioner sinks. Heating operation is recommended only at temperatures of +2 °C and above.

Technical description Dometic FreshLight
The refrigerant circuit of the roof air conditioner consists of five main compo- nents (fig. 1, page 2):
Compressor (1)
The compressor draws in the R407c refrigerant used and compresses it. This raises the pressure and therefore the temperature of the refrigerant.
Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The refrigerant absorbs the heat and vaporises.
A blower distributes the cooled air within the vehicle through an air outlet unit.
Solenoid valve (5)
The solenoid valve allows the cooling cycle to be reversed and the air feeding in to be heated.
Overview of all parts: fig. b, page 7.
Blower (4)

Dometic FreshLight Technical description
The control panel (fig. 2, page 2) is at the air outlet unit of the roof air conditioner.
It contains the following control and display elements:
No. Explanation
No light: The roof air conditioner is switched off.
Orange light: The roof air conditioner is in stand-by mode.
Green light: The roof air conditioning is switched on.
“Heating” conditioning mode ( ) or is being defrosted.
Red light: Only if the system is connected to 12 Vg: the supply voltage of 230 Vw is not available.
Slowly flashing red light:
Malfunction in interior temperature sensor E1
Quickly flashing red light:
Malfunction in exterior temperature sensor E3
2 Button Switches the roof air conditioner on, off or to stand-by mode Pressing the button longer engages the automatic mode.
3 Button Switches the light on or off or dims it. Only active when the roof air conditioner is switched on or on stand-by.
4 Infrared receiver for the remote control
1 Status LED

Technical description Dometic FreshLight
All settings of the device (e. g. temperature settings, timer programming) are transmitted to the roof air conditioner by remote control.
The following control and display elements are available on the remote control (fig. 3, page 3):
No. Explanation
1 Digital display: displays the following: – Time – Selected room temperature (target value) in °C or °F – Actual room temperature – Air conditioning mode – Blower level – Symbols for active additional functions – Battery status
7 SLEEP button: Activates the sleep function. The sleep function automatically reduces the target value to provide a pleasant sleeping temperature.
8 SET button: Transmits current data to the roof air conditioner.
9 I FEEL button: Activates the “I feel” function. Every 10 minutes, the “I feel” function adjusts the target temperature to the temperature measured by the remote control. The remote control must be pointed at the IR receiver (fig. 2 4, page 2) on the control panel.
10 Reset button Resets all values to standard values

Dometic FreshLight Technical description
No. Explanation
Displays the current interior temperature (symbol is displayed). Displays the set temperature.
Press again:
12 LIGHT button: Switches the light of the roof air conditioner on or off. The LIGHT button remains functional even when the remote control is switched off.
16 Symbol (batteries empty) Is displayed when the batteries in the remote control are empty. If this happens, replace the batteries, see “Replacing the remote control batteries” on page 59.
17 Symbol (transmitting values) Is displayed briefly when the remote control is transmitting values to the roof air conditioner.

Technical description Dometic FreshLight
The roof air conditioner has the following air conditioning modes:
Automatic You specify the temperature, and the roof air conditioner brings the interior to this temperature by heating or cooling and by controlling the necessary blower output.
The button is deactivated in this mode.
Cooling You specify the temperature and blower settings, and the roof air conditioner cools the interior to this temperature.
Heating You specify the temperature and blower settings, and the roof air conditioner heats the interior to this temperature.
Circulating air You specify the blower level, and the roof air conditioner blows air into the interior.
Ventilation The roof air conditioner ventilates the interior by sucking the used air from the interior with the blower. The ventilation flap is opened for this purpose.
The button is deactivated in this mode.
Dehumidification You specify the temperature, and the roof air conditioner brings the interior to this temperature by heating or cooling the air, by controlling the necessary blower output and by dehumidifying the interior (Circulating air mode).
The button is deactivated in this mode.
Air conditioning mode · Display message Explanation

Dometic FreshLight Technical description
The roof air conditioner has the following additional functions:
Timer The roof air conditioner is switched on at the specified time.
08:00
20:00
The roof air conditioner is switched off at the specified time.
08:00 20:00
The roof air conditioner is switched on and off at the specified times.
Sleep The set temperature is reduced by 1 °C after one hour and by 2 °C after two hours to generate a pleasant temperature for sleeping.
I feel The remote control measures the room temperature and transmits this measurement to the roof air conditioner every 10 minutes. The roof air conditioner adapts the target value to this measurement. The remote control must be pointed at the IR receiver (fig. 2 4, page 2) on the control panel.
Additional function · Display message Explanation

Before initial use Dometic FreshLight
Inspection before starting up
Before you switch on the roof air conditioner, observe the following:
➤Check whether the supply voltage and frequency correspond to the
values specified in the technical data, see page 66.
➤Ensure both the air intake opening and the air nozzles are free. All
ventilation grilles must always be kept free to ensure that the roof air conditioner is able to operate at maximum capacity. !
Check remote control and insert batteries
➤Insert the provided batteries in the remote control battery compartment,
see “Replacing the remote control batteries” on page 59.
➤Check that the four Dip switches (fig. 4, page 3) are in the correct
position.
➤If you changed the position of the Dip switches: Acknowledge the new
setting using the Reset button (fig. 3 10, page 3).
➤Set the current time: see “Setting the time” on page 60.
Setting the time

Dometic FreshLight Operating the roof air conditioner
The roof air conditioner has three operating modes:
Off The roof air conditioner is switched off. The remote control is inactive.
Stand-by The roof air conditioning is ready for operation and can be switched on with the remote control.
On The roof air conditioner is conditioning the air in the interior.
You can use the control panel to
switch the roof air conditioner on, off or to stand-by mode
switch the light on and off or dim it
You can use the remote control to
switch the roof air conditioner to and from stand-by mode.
switch the light on and off
make the settings
select additional functions
There are two ways to control the roof air conditioner with the remote control:
You can transmit the values directly to the roof air conditioner when you
You can first specify all values on the remote control and then transmit
them collectively to the roof air conditioner
Transmitting values directly when they are set
The remote control must be pointed at the IR receiver (fig. 2 4, page 2) on the control panel during operation.
When a button is pressed, the value is transmitted directly to the roof air con- ditioner. The roof air conditioner confirms the receipt of data with a high note.
Operating mode Features · set them

Operating the roof air conditioner Dometic FreshLight
Specifying values and transmitting them collectively to the roof air conditioner
The remote control may not be pointed at the IR receiver (fig. 2 4, page 2) on the control panel during operation.
Specify the required values on the remote control. Once you have made all your settings, point the remote control to the IR receiver on the control panel and press the SET button. This transmits the data to the roof air conditioner. The roof air conditioner confirms the receipt of data with a high note.
Switching only the remote control to or from stand-by
In stand-by mode, the remote control display shows only the time.
If the remote control is not pointing to the IR receiver (fig. 2 4, page 2) on the control panel, you can activate the remote control or switch it to stand-by independently from the roof air conditioner:
➤Press the button.
The following hints will optimise the performance of your roof air conditioner:
Improve the heat insulation of your vehicle by sealing gaps and hanging
reflective blinds or curtains on your windows.
If the vehicle has been subjected to direct sunlight for a long time: Operate
the roof air conditioner in the “Circulated air” ( ) or “Ventilation” ( ) mode with the windows open for a while before switching on the “Cooling” ( ) air conditioning mode.
Avoid opening doors and windows as far as possible in the “Cooling” ( ) and “Heating” ( ) modes.
Select an appropriate temperature and blower speed.
Align the air nozzles sensibly.
Make sure the air nozzles and intake grille are not covered by cloths,
paper or other objects.

Dometic FreshLight Operating the roof air conditioner
With the control panel
The figure shows how to use the control panel to switch the roof air conditioner on, off or to stand-by. Press the button as shown in the illustration:
Roof air conditioner switched off
Roof air conditioner switched on
Example: The roof air conditioner is in stand-by mode. You want to switch it off.
➤Briefly press the button.
✓The roof air conditioner is switched off.
The roof air conditioner can only be operated by the remote
control when it is switched on or in stand-by mode.
You can use the remote control to switch the roof air conditioner
to and from stand-by mode. Press the button.

Operating the roof air conditioner Dometic FreshLight
Before selecting the “Ventilation” ( ) air conditioning mode, you have to open both blinds completely.
In the “Ventilation” ( ) mode, the blower only starts once the ventilation flap (fig. 5 1, page 4) is open. This can take a few minutes.
When the roof air conditioner is switched to the “Heating” ( ) mode, it takes approx. 30 seconds before heating begins. During this time, the status LED on the control panel flashes and the cooling cycle is reversed.
➤Select the air conditioning mode of your choice using the MODE key, see
“Air conditioning modes” on page 48.
✓The roof air conditioner confirms the receipt of the values with a high note.
✓The roof air conditioner is switched to the selected air conditioning mode.

Dometic FreshLight Operating the roof air conditioner
The blower controls the strength of the air supply. In the “Cooling” ( ), “Heating” ( ) and “Circulated air”( ) modes, the blower levels can be selected manually. In the other air conditioning modes, the roof air conditioner controls the blower level automatically.

Automatic mode, only available in the “Cooling” ( ) and
➤Use the button to select the desired blower level.
✓The roof air conditioner confirms the receipt of the values with a high note.
✓The new blower level has been set.
In the “Automatic” ( ), “Cooling” ( ), “Heating” ( ) and “Dehumidifying” ( ) modes, you can specify a temperature between 16 °C and 31 °C via the remote control.
➤Use the + or – button to select the desired temperature.
✓The roof air conditioner confirms the receipt of the values with a high note.
✓The temperature is set on the roof air conditioner.

Operating the roof air conditioner Dometic FreshLight
The air supply within the vehicle can be regulated by setting the air nozzles.
The air nozzles can be regulated with a slide button (fig. 6 2, page 4) so that air is directed to the front, the back or in both directions:
➤Turn the knob on the slider anti-clockwise.
➤Move the slider so that the air is directed in the required direction.
➤Tighten the knob again in clockwise direction.
The slats (fig. 6 1, page 4) in the front air nozzle can be moved. This directs the air in the required direction.
The timer function allows you to set a specific time period for air conditioning. You can specify the switch-on time, the switch-off time or both values. The time can be set in 10 minute increments. I
➤Before programming the timer, select the air conditioning mode and all
required values (e.g. temperature).
Setting the switch-on time
➤Press the TIMER button once.
✓The ON symbol ( ) flashes on the display of the remote control.
08:00
➤Use the + or – button to set the time when the roof air conditioner is to
switch on.
➤Press the SET button to transmit the value to the roof air conditioner.
✓The switch-on time is set on the roof air conditioner.
The roof air conditioner is switched on with the selected air conditioning mode at the specified time.
➤Switch the roof air conditioner to stand-by.

Dometic FreshLight Operating the roof air conditioner
Setting the switch-off time
➤Press the TIMER button twice.
✓The OFF symbol ( ) flashes on the display of the remote control.
20:00
➤Use the + or – button to set the time when the roof air conditioner is to
switch off.
➤Press the SET button to transmit the value to the roof air conditioner.
✓The switch-off time is set on the roof air conditioner.
The roof air conditioner runs in the selected air conditioning mode until the specified time.
Setting the switch-on and switch-off times
➤Press the TIMER button three times.
✓The ON symbol ( ) flashes on the display of the remote control. The OFF symbol ( ) is displayed.
08:00
20:00
➤Use the + or – button to set the time when the roof air conditioner is to
switch on.
➤Press the TIMER button again.
✓The OFF symbol ( ) flashes on the display of the remote control.
20:00
➤Use the + or – button to set the time when the roof air conditioner is to
switch off.
➤Press the SET button to transmit the value to the roof air conditioner.
✓The switch-on and switch-off times are set on the roof air conditioner.
The roof air conditioner starts in the selected air conditioning mode at the specified time and runs until the second specified time.
➤Switch the roof air conditioner to stand-by.
If you have set the timer, you can cancel these settings as follows:
➤Press the TIMER button five times.
✓The timer symbol disappears. The setting has been cancelled.
Cancelling timer settings

Operating the roof air conditioner Dometic FreshLight
When the sleep function is active, the set temperature is reduced by 1 °C after one hour and by 2 °C after two hours to generate a pleasant tempera- ture for sleeping.
➤Set the required temperature (see “Setting the temperature” on page 55).
➤Press the SLEEP button.
✓The symbol appears in the display. The sleep function is activated.
When this function is active, the remote control measures the room temperature and transmits this measurement to the roof air conditioner every 10 minutes. The roof air conditioner adapts the target value to this measure- ment.
➤Press the I FEEL button.
➤Position the remote control so that it points at the IR receiver (fig. 2 4,
page 2) on the control panel. Otherwise, the values cannot be transmitted to the roof air conditioner. I

Dometic FreshLight Operating the roof air conditioner
The lights on the roof air conditioner can be dimmed. When switched on, they revert to the most recently specified brightness.
Switching the light on/off with the control panel
➤Briefly press the button to switch the lamps on or off.
Dimming the light with the control panel
➤Press and hold the button until the lights have been dimmed to the required brightness.
➤In order to dim the lights in the other direction: Briefly release the
button and then press and hold it again.
Switching the light on/off with the remote control
➤Press the LIGHT button to switch the lamps on or off.
Replace the batteries if you see the symbol on the display.
The battery compartment is on the back of the remote control.
➤Gently push down the lid of the battery compartment and slide it open in
the direction of the arrow.
➤Insert the new batteries (2 x type AAA) in the remote control as indicated
in the battery compartment.
Protect the environment! Do not dispose of batteries with general household waste. Return any used batteries to your retailer or take them to a collection point.

Operating the roof air conditioner Dometic FreshLight
The remote control needs the current time in order to program the timer. The time is indicated on the display of the remote control. Perform the following steps to set the time: I
➤Press and hold the CLOCK button to go to the mode used to set the time.
✓The time flashes on the display of the remote control.
➤Use the + or – button to set the current time.
➤Press the SET button to confirm the time.
The two blinds can be used to control the sun and light penetrating the vehicle.
➤Move the blinds manually (fig. 7, page 5).

Dometic FreshLight Cleaning the roof air conditioner
Do not clean the roof air conditioner with a high-pressure
cleaner. Exposure to water can damage the air conditioner.
Do not use sharp or hard objects or cleaning agents for cleaning
as these may damage the roof air conditioner and the window.
To clean the roof air conditioner, use water with a gentle
cleaning agent. Never use petrol, diesel or solvents.
When cleaning the roof window, use only cleaning agents that
are approved by the manufacturer. – Acrylic glass polish (item no. 9104100242), – Special polishing cloth (item no. 9104100243) and – Acrylic glass cleaning agent (item no. 9104100244) I
➤Clean the housing of the roof air conditioner and the air outlet unit
occasionally with a damp cloth.
➤Regularly remove leaves and other dirt from the ventilation grilles
(fig. 8 1, page 5) of the roof air conditioner. Make sure you do not damage the grilles in the process.
➤Clean the remote control with a slightly damp cloth from time to time. We
recommend using a cleaning cloth for glasses to clean the display.
➤Clean the roller blind with mild soap and plenty of water.

Maintenance of the roof air conditioner Dometic FreshLight
Regularly Check the condensation water drainage:
➤Check whether the condensation water drainage channels
(fig. 9 1, page 5) at the sides of the roof air conditioner are clear and the condensation water is able to escape.
Regularly Clean the filters on both sides of the air discharge unit (fig. 0, page 6):
➤Manually take off the filter cover (1).
➤Remove the filter (2).
➤Clean the filter (2) with a detergent solution and let it dry.
➤Put the dry filter (2) back in.
➤Put the cover (1) back on.
Once per year Check the profile seals:
➤Check the seal between the roof air conditioner and the roof of
the vehicle for cracks and other damage.
Once per year Have the heat exchanger serviced:
➤Have the heat exchanger of the roof air conditioner serviced
by specialist workshop.
Once per year Replace the carbon filter (fig. a, page 6):
➤Manually take off the filter cover (1).
➤Remove the filter (2).
➤Remove the carbon filter (3).
➤Clean the filter (2) with a detergent solution and let it dry.
➤Put a new carbon filter in.
➤Put the dry filter (2) back in.
➤Put the cover (1) back on.
Interval Inspection/maintenance

Roof air conditioner constantly switches itself off.
Icing sensor has tripped. Outer temperature is too low or all air nozzles are closed.
The roof air conditioner is not set to cooling.
➤ Set the roof air conditioner to cooling.
The ambient temperature is above 52 °C. The roof air conditioner is only designed for ambient temperatures of up to 52 °C.
The temperature set is higher than the room temperature.
➤ Select a lower temperature.
The ambient temperature is below 16 °C. The roof air conditioner is only designed for ambient temperatures above 16 °C.
One of the temperature sensors is defective.
➤ Contact an authorised work- shop.
The vaporiser fan is damaged.
The condenser fan is damaged.
The ambient temperature is above 30 °C. ➤ Only use the heating function of the roof air conditioner at temperatures below 30 °C.
The ambient temperature is below 2 °C. The heating function of the roof air conditioner is only designed for ambient temperatures of up to 2 °C.
The temperature set is above 30 °C. ➤ Select a lower temperature.
The roof air conditioner is not set to heating.
➤ Set the roof air conditioning to heating.
One of the temperature sensors is defective.
➤ Contact an authorised workshop.
Low air output The air intake section is clogged up. ➤ Remove any leaves and other dirt from the ventilation grilles of the roof air conditioner.
The blower is defective. ➤ Contact an authorised workshop.
Water enters the vehicle
The condensation water drainage openings are clogged up.
➤ Clean the drainage openings for condensation water.
The seals are damaged. ➤ Contact an authorised workshop.

Roof air conditioner does not switch on.
No supply voltage (230 Vw) connected.
➤ Check the power supply.
The voltage is too low (under 200 V). The voltage converter is defective.
➤ Contact an authorised workshop.
One of the temperature sensors is defective.
The electrical fuse of the power supply is too low.
➤ Check the electrical fuse of the power supply.
Roof air conditioner does not switch off.
One of the temperature sensors is defective.
➤ Contact an authorised workshop.
The electrical fuse of the power supply is too low.
➤ Check the electrical fuse of the power supply.
The statutory warranty period applies. If the product is defective, please contact the service partner in your country (addresses on the back on the instruction manual).
Our experts will be happy to help you and will discuss the warranty process with you in more detail.
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the influence that their activities (manufacturing, products, services, etc.) have on the environment.
The procedures to be followed to identify significant environmental impact must take the following factors into account:
use of raw materials and natural resources
discharge of liquids
waste management and recycling
contamination of the soil
Warranty Dometic FreshLight · Problem Cause Remedy · atmospheric emissions

In order to minimise environmental impact, the manufacturer provides a series of indications here below that should be taken into account by all those who, for whatever reason, interact with the appliance during its working life.
All packing components must be disposed of (preferably recycled) in
compliance with statutory legislation in the country in which disposal takes place.
All product components must be disposed of (preferably recycled) in
compliance with statutory legislation in the country in which disposal takes place.
For correct disposal, the appliance must be consigned to an authorised
waste disposal company to ensure that all recyclable components are reused and the remaining materials are processed properly.
During installation ensure the room has adequate ventilation to prevent
the build-up of stale air that might be harmful to the health of the operators.
During operation and maintenance ensure that any waste pollutant
products (oil, grease, etc.) are disposed of correctly.
Keep noise levels down to reduce noise pollution.
For more information on correct dismantling of our products please refer to the recycling handbooks at www.dometic.com
➤Place the packaging material in the appropriate recycling waste bins
wherever possible.
➤When in operation or undergoing repairs and maintenance work, make
sure that the refrigerant circuit is not damaged and refrigerant cannot escape. It acts as a greenhouse gas and should not be allowed into the environment. M
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
➤Dispose of the product at an official waste disposal facility in accordance
Protect the environment! Do not dispose of any batteries with general household waste. Return defective or used batteries to your retailer or dispose of them at collection points.
Dometic FreshLight Disposal

Technical data Dometic FreshLight

Max. volume of space in the vehicle (with insulated walls):
Dimensions L x W x H (mm): 1105 x 758 x 210 (height above vehicle roof)

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.