This appliance can only be used and is only suitable for the country and the type of gas mentioned on the type identification tag. Please check that the local gas and pressure correspond with the specifications on the type identification tag.The type identification tag is a metal plate.
All regulations regarding gas installation, including any local regulations, must be observed at all times. The appliance is to be installed by a registered gasinstaller.
The appliance has been designed to be built snugly into a newly built chimney breast of incombustible and heat- resistant material, optionally with a decorative mantelpiece.The DRU range includes several suitable chimney breasts. For this appliance you will need to use a service flap. The service flap should be fitted within 1 metre left or right of the heater, to allow for the length of the wires. For the dimensions and installation instructions, see the section on the service flap. If you build the chimney breast of any material other than stone (e.g. Promatect), we advise you to use a fibreglass wallpaper and not plaster. If you do use plaster make sure the flanges are not plastered over as they could crack from the heat of the fire. Allow sufficient space for the depth of the appliance (400 mm).The appliance must not be mounted too closely against the back wall. The built-in height will depend on how high the adjustable feet are set. Now move the appliance into the required position. Allow a little room all round the appliance in the fireplace so that the heat can escape. To allow adequate heat removalthe chimney breast should be well vented. The total free vent area should be at least 200 cm2. We advise you to fit vents on both sides. The DRU range includes suitable design vents. Take the box of logs and the bag of accessories out of the combustion chamber by removing the glass pane.
We would like to thank you for buying this DRU product. Our products have been designed and produced to meet the highest possible quality, performance and safety requirements, allowing you to enjoy years of problem-free use.
The heater has an enclosed combustion chamber. Its natural draught draws in the combustion air from outside through a combined inlet-outlet system.The same natural draught expels the combustion gasses.
In this booklet you will find instructions for the installation and use of your new appliance. Please read these instructions and the manual carefully to familiarize yourself with the appliance. If you require any further support, please do not hesitate to contact your supplier.
Once the heater has been unpacked, all packaging should be disposed of in the regular manner.
This appliance should be connected by a registered gasinstaller.



The appliance has brackets for wall assembly.These must be used. Connect the appliance. NB: To ensure the ignition works properly, the ignition wire must come into as little contact as possible with the metal parts of the heater and should therefore not be wound round the gas or pilot-light pipes or the thermocouple. The pilot flame pipe should not make contact with the groeund and walls of the space in which the appliance will be built.
Place the receiver in the tray (3). Make sure the “LED” is pointing forwards. Fit the outer frame with flap (4) to the inner frame using the two self-tapping screws (5). The outer frame can be fitted with the flap turning to the left or the right, as required.

Brackets for wall assembly
Service flap (fig. 2C). Make a hole of 285 mm x 194 mm (h x w) for the service flap. Fit the inner frame (1). If you are building a brickwork chimney breast the frame can be built in at the same time. For a chimney breast of any other material, glue/cement the inner frame in place or fit it with four countersunk screws Ex-works, the gas control block is mounted under the appliance. The gas control block cannot stay under the appliance however, and should be removed. To do this: Undo the flexible gas pipe (spanner 17), the aluminium pilot light pipe (spanner 10) and the thermocouple (spanner 10) and carefully unwind the pipes, making sure there are no kinks. Now remove the gas control block. Lead the pipes to the required position, making sure that no dirt gets into them. Mount the gas control block on the brackets (2) on the inner frame. Connect the pipes to the back of the gas control block. Make sure that the flexible hose and the aluminium pipe connections are gastight. First screw the thermocouple on by hand, and then tighten one quarter turn with the spanner.
fig. 2c
Possible connections (fig. 4)
Allow 2 metres for a bend of 90° and 1 metre for a 45° bend.There is no need to allow for the length of the wall or roof duct. The maximum total length is the sum of the pipe lengths plus the equivalent length for the bends (see the 5 examples in fig. 4).
The roof duct set, the supply and flue pipes, the concentric pipe and bends are packed individually and supplied together with a clip binding with sealing ring.Tile flashing or adhesive flashing is also available for use with a duct through a slanting or flat roof respectively.
38c-1078

(H totaal= 5m) L=1+2+5+(2x1)=10
L=4+1+(2)=7
NB: This appliance may only be installed using the flue material ø150/ø100 supplied by DRU.This has been approved together with the appliance to comply with all requirements. DRU cannot guarantee that the appliance will work correctly and safely if alternative installation material is used.
Preparations for the installation of the combined inlet-outlet system
Roof duct with concentric pipes
Wall duct with concentric pipes

Fitting the fire to an existing chimney
Use the adjustment jig provided (fig. 5) to adjust the baffle to the right size. Once it has been adjusted, fix the damper in place with the socket-head screw. See the table for adjustment specifications. In some cases the air inlet baffle should be removed (tabel). To do this: (fig. 7). Take strip (1) and the vermiculite trays (2+3) out of the appliance. Remove the air inlet baffles and screw the self-tapping screws back in place. Replace the vermiculite trays (2+3) and the strip (1) in the appliance.
The fire can be fitted into an existing chimney providing that the chimney / flue dimensions are 150 mm or more. A special flue kit is required, which can be obtained from Drugasar or a Drugasar agent. Do not use any other type of flue system for this.
BS 5871 – 1 : 2001 Any chimney previously used for an appliance burning a fuel other than gas shall be swept thoroughly before installing any gas appliance. Appliances shall be connected only to the types and sizes of flue system as specified.
NB: the maximum length of horizontal pipe must not be exceeded.
For any other information about this flue system please contact Drugasar or Drugasar approved agent.
Fig. 4 illustrates how to calculate the total lengths of pipe.
To ensure that the appliance works satisfactorily, it will need to be adjusted according to the customer-specific pipe system.
Adjusting the baffle. The baffle plate is supplied separately and should be fitted into the heater as indicated in fig. 6.
Air inlet Damper Distance baffle damper
8 - 12 metres vertical + roof duct YES YES 30 mm 5 - 7 metres vertical + roof duct YES YES 35 mm 1 - 4 metres vertical + roof duct YES YES 40 mm 1m vertical + 1 - 3 mtr horizontal + NO NO OPEN wall duct 1 m vertical + wall duct YES YES 75 mm 0,5 m vertical + 2 m horizontal + NO NO OPEN wall duct 0,5 m vertical + wall duct YES NO OPEN
Baffle · Baffle · 38c-1122

Connecting the Gas Supply
covered with vermiculite to avoid shortening the operational life of the burner.
Place log A as indicated in figure 11. Place log B under log A, in such a way that the recess at the bottom is placed over the rear of the burner. See figure 12
Place log C on the ridge on the left corner of the burner, as indicated in figure 13. The bevelled corners of log D are placed in the left rear corner of the combustion chamber, and log D is placed on block A in an inclined position. See figure 14.
Placing the wood set
Log E should be placed at the front on the burner’s combs and to the right against the front of log A. Figure 15. Now place log F (with the scorch mark to the front) on log A, as indicated in figure 16. Fill the tray surrounding the burners with chips; spread the chips evenly. Make sure the chips do not fall into the tray below.At the front, the chips may only be placed on the combs in an inclined upward position, as indicated in figure 16.
Wood set The wood set consists of vermiculite (figure 8), chips (figure 9), resistance wire and 6 logs.
Spread the resistance wire over the first burner to the left and right of log B. Make sure the resistance wire does not get too close to the pilot burner.
Cover the burners with the vermiculite; spread the vermiculite evenly, see figure 10. Caution - You can influence the flame image by moving the vermiculite, however; the burner floor must remain
38c-1084 · Luchtinlaat geleider · Air inlet baffle





After placing the wood/pebble set you can plac e the glass window, as described below. NB: Avoid damages when removing/placing the glass window.
Placing the glass window The glass window is fi tted by using the above procedure, in reverse order. NB: Avoid/remove fi ngerprints on the pane, since
otherwise they will burn into the surface; - The self-tapping screws must not be over-tightened,
since otherwise they could break or strip the thread: tight=tight; - Replace the fastening strip if the sealing cord has
Glass window

For safety reasons a guard should be placed in front of the fire at all times.



fig. 18 fig. 19


fig. 20 fig. 21


fig. 22 fig. 23



!Caution - Do not place the antenna too close to the
ignition cable and/or metal parts: make sure the antenna is pointing upwards (for the correct position, see fig. 29); - Make sure the ignition cable is not running
The appliance is supplied with a remote control. Ignition, controlling the flame height and switching off are performed by the remote control that operates a receiver in the control box. The receiver and remote control are battery powered.The receiver requires 4 penlite (AA type) batteries, the remote control requires a 9V block battery.At normal use, the batteries will have an average life of one year. You can also use an optional adapter.Ask your installer for information. In that case you will need a 230 V connection near your appliance.
over/alongside metal parts: this will weaken the spark; - Do not lay the ignition cable over the receiver:
this could damage the receiver.
The appliance’s standard functions such as ignition, controlling the flame height, standby (pilot burner) position and switching off are performed in the MAN position, the manual control of the remote control (see fig. 30).

The receiver is located in the control box (see fig. 29).

If the receiver’s batteries are almost empty, you will hear 3 short beep sounds, provided the little motor for controlling the main burner is running.
In addition, the remote control can also be used to set a number of additional functions: - temperature display in degrees Celsius or Fahrenheit; - time; - thermostat function; - timer for thermostat function.
that your appliance’s ignition process can be started unintentionally through other remote controls.This could be the remote control of your neighbours' gas heater, but also car keys and garage door openers. The result will be that your appliance will burn when you do not want it to.
!Caution - Avoid a short circuit between the batteries and
metal objects/parts; - Observe the “+” and “-” poles of the batteries
and the holder; - Use alkaline batteries; - Batteries are regarded as “small chemical
waste” and may therefore not be disposed with the household rubbish.
Unintended ignition of your appliance could be solved/prevented by: - setting a new communication code between remote

- when left unattended for a longer period, set button A
- The appliance will automatically enter the
on the gas control to the position MAN (see section; - close the gas tap near your appliance.This is the safest
standby position, if there is no transmission for 6 hours.
precaution, if the appliance will not be used for a longer period; - Observe stated precautions / safety instructions - even if
the appliance is not in use.
Setting the communication code
to operate control button B on the gas control manually (see fig. 32); - Always wait 5 minutes after the pilot burner has
Prior to putting the application into operation, a communication code must be set between the remote control and the receiver.The code is chosen randomly from the 65000 available codes.As a result, the chance that other remote controls near you are using the same code and affect the operation of your appliance is very small.
gone out, before you re-ignite the appliance; - When using propane you must be extra careful.
The pilot burner may extinguish due to air in the pipe, e.g. as a result of replacing a propane cylinder:Always strictly observe a 5 min. waiting time before restarting the ignition process; - Close the gas tap in case of malfunctions and/or
poor operation and warn the installer.
!Tip For propane appliances, please use a system of two cylinders provided with an automatic switch to the back-up cylinder, if separate gas cylinders are used.


!Caution When installing a new remote control or
receiver, you must set a new communication code.
By briefly pressing the SET button, you will go through the following functions: MAN → ✹TEMP → TEMP →(P*)TIMER →MAN where, depending on the timer setting: (P*) is displayed as P1✹, P1 , P2 ✹, P2 .
process is active; - a short sound signal will indicate that the ignition process
!Tip You can also go back to the MAN position by pressing the button (large flame) or (small flame).
has finished; - the appliance will automatically switch through to the
highest position of the main burner, which will start to burn in a few seconds.
!Caution - When pressing the buttons (with the
exception of the SET button), the transmission symbol ( ) will appear to indicate that transmission is taking place between the remote control and the receiver; - The receiver acknowledges the transmission
attempts, you must close the gas tap and call the installer; - When igniting the pilot burner, you will hear
with a sound signal;
sound signals.After the last short sound signal,
Ignition · MAN position

the main burner should be largely ignited within about 10 seconds. If this is not the case, you must close the gas tap and warn your installer;
Using the thermostat function you can set two temperatures, which can be controlled thermostatically. These temperatures are referred to as day temperature and night temperature. The ✹TEMP and TEMP symbols on the display refer to day and night temperature respectively. The room temperature is compared to the set day/night temperature and then the flame height is automatically controlled in order to reach the set temperature. To be able to use the day/night temperature function, the appliance must be in the standby position.
- If the appliance ignites with a pop sound, you must close the gas tap and contact your installer.
!Tip A little motor will start to run when the main burner operates, you will be able to hear it.
Flame height / standby
!Caution - Always leave the remote control at the same
place, so that the thermostat is able to ‘feel’ the room temperature; - Make sure this place is free from influences such
as draught, heat from radiators and direct sunlight.
Example By using the ✹TEMP function you can keep the day temperature at 20 ºC; while you use the TEMP function at night to maintain a temperature of 15 ºC.
By using the SET button, you will go through the following functions: MAN → ✹TEMP → TEMP →(P*)TIMER →MAN
must close the gas tap and contact your installer.
Switch the appliance off by pressing the OFF button. The pilot burner will also go out.
The room temperature can be indicated on the display in degrees Celsius (ºC) using a 24 hour clock or degrees Fahrenheit (ºF) using a 12 hour clock. • Simultaneously press OFF and (small flame), until the correct display appears.
!Caution - The minimum temperature you can set is 5 ºC /
40 ºF; - Control of the night temperature is switched off
by lowering the temperature until two stripes (“--”) appear on the display.
Activating the thermostat function

Timer for thermostat function
Using the timer enables you to set two times per 24 hours for switching on the day temperature and two times per 24 hours for switching on the night temperature. In order to control the night temperature, it should be set to at least 5 ºC / 40 oF. If the night temperature is set to the “- - ” position, the appliance will remain in the standby position.The appliance will only switch on at the next switch-on time of the day temperature. The appliance must be in standby position in order to be controlled by the timer
If the battery is almost empty, the display will show “BATT”.
!Caution - Observe the “+” and “-” poles of the batteries
and the connector; - Use alkaline batteries; - Batteries are regarded as “small chemical waste”
and may therefore not be disposed with the household rubbish.
Example of switch times
You have set a day temperature and night temperature of, for example, 20 ºC and 15 ºC. P1 ✹TIMER = 7 hours; the temperature will go to 20 ºC at
7 am. P1 TIMER = 9 hours; the temperature will go to 15 ºC at
9 am. P2 ✹TIMER = 17 hours; the temperature will go to 20 ºC
at 5 pm. P2 TIMER = 22 hours; the temperature returns to 15 ºC
at 10 pm.
Setting times for the timer
Activating the timer function
Replacing the battery

GENERAL NOTES
reconstructions / renovations done, you are advised to wait at least 6 weeks before lighting your fire, to allow the walls, floor and ceiling to dry out completely.
Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that all gas appliances are installed by competent persons in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution.
Lighting the heater for the first time
There can be an unpleasant smell when you light the heater for the first time.This is caused by the varnish evaporating and will disappear after a few hours.We therefore advise you, on initial use, to heat the appliance at the highest setting while ventilating the room it is installed in well.
NB:The Council of Registered Gas Installers, whose members are identified by the emblem shown here, are all required to work to the recognised standards.
This heater meets the normal safety standards regarding surface temperatures, but physical contact with heated surfaces should be avoided where possible.An additional guard is recommended to protect young children and elderly, infirmed or handicapped people. For safety reasons a guard should be placed in front of the fire at all times.
The appliance should be inspected once a year by a qualified company, and cleaned and/or repaired as necessary.The inspection and maintenance must at least ensure that the appliance is working correctly and safely. This can be done by your own gasinstaller or a specialised maintenance company. It is advisable to remove any dust from the appliance several times before and during the heating season.After a while a deposit will form on the inside of the glass pane.This can be removed with a damp cloth or with a non-abrasive cleaning agent (e.g. brass polish). Do this as soon as any deposit appears, to prevent it from burning and becoming impossible to clean. Do not use corrosive or abrasive substances to clean the casing. Any damage to the coating, caused by things put on or
When replacing or otherwise removing the appliance, it should be disposed of in compliance with current regulations.
Shut off the connecting tap with coupling before commencing disassembly. Undo the coupling between the connecting tap and the appliance.The whole appliance can now be disassembled and removed.
against the casing for example, is not covered by the guarantee.
The warranty for your DRU appliance will be provided by your supplier. In case of malfunctions, you should always contact him.You supplier will contact DRU if he feels this is necessary.The factory warranty for your appliance is valid for 2 years after date of purchase.
NB: When replacing the thermocouple, the coupling nut in the gas control block should first be tightened by hand and then tightened a quarter-turn with an open-ended spanner.
Discoloration of walls and ceiling
Brown discoloration is an annoying problem, which is difficult to solve. It can be caused by dust burning as a result of poor ventilation, for example, or by cigarette smoke or candles.
These problems can be avoided by ensuring that the room the heater is in is properly ventilated.A good guideline for ventilation is: New buildings : 3.24 m3 / hour per m2 floor
surface of the room. Existing buildings : 25.20 m3 / hour for a room.
Use candles and oil lamps as little as possible, keeping the wick as short as possible.While they Enhance the atmosphere, candles and oil lamps also cause the formation of large quantities of unhealthy soot particles in your home. Cigarette and cigar smoke contains tar, which upon heating will precipitate on cold or damp walls. If you have a newly cemented chimney or have had any other

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.