Above all: always ensure there is adequate ventilation. The heater uses oxygen. If this is not supplied in sufficient measure, it will produce carbon monoxide. Inadequate ventilation can therefore cause carbon monoxide poisoning and this can lead to serious illness or death. Always ensure that the heater and the working area are supplied with continual fresh air from outdoors. Make sure there are two 2,800 cm² (so 70 x 40 cm) openings to the outside for every 100,000 Btu/hour: one low opening (close to the ground) and one high opening (near the ceiling). Fireball 22T: 0.7 x 2800 = 1960 cm² so: 2 openings of 40 x 50 cm. Fireball 37T: 1.26 x 2800 = 3528 cm² so: 2 openings of 40 x 90 cm. The first signs of carbon monoxide poisoning are flu–like symptoms: headaches, dizziness and nausea. If you are aware of these symptoms, your heater may not be working correctly or there is inadequate ventilation. You must ensure that fresh air is provided immediately! Have the heater checked and/or ensure that there is adequate ventilation. One person may be more sensitive to carbon monoxide than another. Pregnant women, people with heart or lung problems or anaemia, the elderly and people under the influence of alcohol are at an increased risk. Never use the heater in living-, work- or sleeping areas! Know you heater: ensure that you (and any other heater users) understand the instruction booklet and the labels on the heater. This will ensure you are aware of where it can be used, its limitations and any potential hazards.
Never use the heater in a dangerous environment: not outdoors, where it is exposed to all weather conditions, or in damp/wet/dusty locations. Do not use in places where flammable liquids, gases, substances or other flammable items can be found: this may pose an explosion risk! Always ensure there is sufficient safe space around the heater.
Keep children and inexperienced persons out of the vicinity of the workplace: all visitors must be kept at a safe distance from the heater.
Prevent unexpected starting: check that the switch is OFF before you insert the plug into the socket.
Stay alert: always be aware of what you are doing and use your common sense. Do not use or operate the heater if you are tired or under the influence of alcohol, drugs, or medicines that impact upon your response times.
Make sure that you remove the plug from the socket: always remove the plug when the heater is not being used, before you carry out maintenance or replenish fuel.
Store the heater safely when it is not in use: keep it in a dry, locked cupboard, out of the reach of children. Empty the fuel.
Use the heater for its intended purpose only. Do not make any changes or connect anything to it. If you are not sure of whether the heater can be used, contact your supplier or the importer.

Only have your heater repaired by a qualified person: the heater fulfils safety requirements. That is why repairs must only be carried out by a suitable, qualified individual, using original parts. Deviations from this regulation will invalidate the guarantee and the supplier and manufacturer will no longer be liable for any consequences.
And also: Every time you use it, check that the heater is in good condition and is working
properly. Have damaged parts repaired or replaced immediately. Never use a damaged heater. Only connect the heater to a socket which corresponds to the voltage and
frequency that is stated on the heater’s specification plate. Only use an earthed, 3-pin socket. If you have to use an extension cable, make sure it is 3-wire and of the appropriate thickness! Only use paraffin or diesel of a good quality in your heater, in accordance with the
instructions in this booklet. NEVER use fuel such as petrol, benzene, used oil, naphtha, alcohol, turpentine, thinner, paint thinners or other oil compounds or flammable liquids in the heater. This may lead to a risk of explosion. Always position the heater on a flat, stable and horizontal surface. Stellen Sie den
Heizer stets auf eine flache, stabile und ebene Unterlage. This heater is not suitable for use on a wooden or any other flammable surface. If necessary, place inflammable material which is at least 26 mm thick under the heater. This must extend one metre from the heater at the back and sides and at least 2.5 metres in front. Keep the front of the heater at least 2.5 metres from any flammable materials
such as wood, plastic, paper, tent cloth, etc and the back and upper sides at least 125 cm from this type of material. Stow tent cloth/plastic etc or ensure there is additional distance between this type of material and the heater (see distances indicated).. Do not use the heater in the vicinity of paint, flammable materials, liquids, gases
or pressurised gas pipes. Do not use the heater in an enclosed space, living area, ground floor, cellar or
space under ground level. Do not start the heater if the combustion chamber chamber is not hot. Do not start the heater if too much fuel has gathered in the combustion chamber. Do not allow untrained, inexperienced people to operate the heater and do not
allow it to be operated unless all covers, lids and so on have been correctly installed. People with respiratory problems must first consult a doctor before using the heater. Never leave a working heater unsupervised but switch it off when you leave the
workspace. Give it time to cool down before you remove the plug from the socket. Do not switch the heater off by removing the plug from the socket; always use the on/off switch. Always remove the plug from the socket if the heater is not in use. Make sure, after use, that the heater has been switched off properly and store it in
a safe and dry environment out of the reach of children. Verwijder de brandstof. Do not replenish the fuel when the heater is working or is still hot. Switch it off,
remove the plug from the socket and leave to cool. Replenish fuel outdoors and make sure that there are no naked flames nearby. Do not overfill the fuel tank

and remove any spilt fluid immediately en zorgvuldig. Gebruik geen externe brandstofvoorziening. Never move the heater and do not touch if it is in operation or is still hot. Unplug
and then leave to cool. The heater (and cap and blower opening) become extremely hot during use.
Never touch the heater during or shortly after operation but leave to cool and wear protective gloves. Particular attention has to be given where children and vulnerable people or anumals are present. do not let bare skin come into contact with hot surfaces. Never transport the heater with fuel in the tank! Do not damage the electrical cable. Do not tilt the heater using the cable and do
not pull on the cable to remove the plug from the socket. Keep the cable away from heat, oil and sharp edges. Do not use the heater if the cable is damaged but make sure it is replaced by your supplier or a recognised electrician in order to prevent risks. Never block the heater’s inlet and outlet openings! Never place any cooking
devices or similar on the heater. Do not use a pipe or similar on the front or back of the heater. Do not use the heater in rooms used by children. Do not allow children or animals
in the vicinity of the heater, particularly if it is on or still hot. Close supervision is necessary when the product is used near children,
incapacitated persons or pets. The device is not suitable for use by persons (including children) with a physical, sensual or mental limitation or a lack of experience and knowledge, irrespective of whether they are being supervised or have been issued with instructions in relation to the use of the device by a person who is responsible for their safety. Always ensure that children cannot play with the device. If using in locations with (too) little ventilation, too much moisture etc, special
measures must be taken in relation to the supply and removal of air, soot, extinguishing etc. Consult a qualified expert in this instance. WARNING! Never expose the heater to water, rain, drips or moisture of any
variety. This could lead to an electrical shock! Be aware that heaters that are equipped with a thermostat may turn on at any
moment. WARNING! The heater is equipped with a thermostat and can come on at any
moment. Never look directly into or stand in front of the hot air-outlet of the heater.





Fireball 20T Fireball 37T Pressure bar 0.25 0.43 Capacity BTU/h 70.000 126.000 kW 20 37 kCal/h 17.500 31.800 Connected power V/Hz/A 220-240 / 50 / 0,75 220-240 / 50 / 0,86 Fuse A 5 5 Max. heated area m² 625 1040 Fuel paraffin or diesel Capacity of fuel tank l 20 32 Fuel consumption l/u 1,85 3,6 Max. working pressure per tank
Air displacement m³/h 430 600 Motor capacity W 160 186 Dimensions mm 778x313x418 924x506x586 Weight kg 15 22,5

Place the handle on the upper cover, with the screw holes lined up, and secure the handle by turning the screws – see diagram.


OK-heaters work with paraffin or diesel; paraffin gives the cleanest combustion. Be aware that the more dust and dirt that is contained in the fuel, the more ventilation will be required! Use the cleanest fuel possible. Note: paraffin may only be stored in blue containers; red containers are associated with petrol! NEVER use other fuels such as petrol, alcohol, oil compounds or similar in this
heater; this could lead to fire or explosion! NEVER store paraffin in direct sunlight of near a source of heat. Do not store paraffin in living/work areas but in a well-ventilated area such as a
shed, storage area or similar. NEVER use paraffin from the previous season. Paraffin deteriorates in quality and
will not burn properly as a result. If you can, use 1-K paraffin in this heater. Other premium quality paraffin may also
be used.
Fuel system: The heater is fitted with an electric air pump that pushes air through the air pipes along the fuel inlet and forces the fuel from the tank into the fuel nozzle. This mixture of fuel and air is then sprayed into the combustion chamber as a fine mist.
Ignition mechanism: The electronic ignition creates a charge on a electrode/sparkplug. This uses a spark to ignite the mixture of fuel and air, as described above.
Air system: The heavy motor drives a ventilator that sends air into and around the combustion chamber. The air is then heated up and driven out of the front of the heater.
Safety devices:
Temperature limiter: This heater is fitted with a temperature limiter that switches the heater off if the internal temperature rises to an unsafe level. If this safety device is

triggered, it may mean that your heater needs to be serviced. If the temperature has dropped to under the reset-temperature, the heater can be used again. Electrical system safeguard: The heater’s electrical system is protected by a safety fuse. The fuse safeguards the electrical components against damage. If the heater does not work, first check the fuse and replace it with a similar fuse if necessary.
Flame control: The heater uses a photoelectric cell to keep an eye on the combustion chamber when the heater is operating. It will switch the heater off if the flame goes out.


Read all instructions and warnings on the warning stickers and in the instruction booklet
and check the heater for defects! Fueling
Place the heater on a stable, flat and horizontal surface. Remove the tank cap. Fill the tank with clean paraffin or diesel till the fuel gauge points “F”. Replace the cap on the tank.
Before use, check the device and the electrical cable, plug and socket for any
damage or wear and tear and do not use if you discover any problems. This heater is fitted with a standard 250V - 16A plug. Choose an impact-resistant type if it ever needs replacing. The electricity network to which the heater is connected must be equipped with an earth leakage circuit breaker (30 mA) and the socket

must be earthed. Repairs to the electrical system must always be carried out by a qualified electrician! Before use, always check that the socket is of the correct voltage, is earthed, has
an adequate fuse (5A) and forms part of a mains network with an earth leakage circuit breaker. If you have to use an extension cable, make sure that the cable is of a suitable
width which is appropriate for the voltage and amperage. Make sure the ON/OFF-switch is on

‘OFF’-position. Now insert the plug into an appropriate
and earthed socket. Set the thermostat to the desired
setting (Min. 5ºC – max. 45ºC). Press the ON/OFF switch to ON. The
light and the display will come on and the heater will start.
If the heater won’t start, the thermostat regulator may be set too low. Turn the thermostat button up and try again. If it still doesn’t start, set the switch to OFF and then switch back to ON.
Stopping the heater:
Press the ON/OFF switch to OFF and remove the plug from the socket.
Restarting the heater:
Wait at least 10 seconds after you have switched the heater off. Repeat the steps set out under: ‘Starting the heater’.
At least 2 x 2,800 cm² per 100,000 BTU/hr
Fireball 22T: 0.7 x 2800 = 1960 cm² so: 2 openings of 40 x 50 cm. Fireball 37T: 1.26 x 2800 = 3528 cm² so: 2 openings of 40 x 90 cm.

Fireball 20T: Undo the tank cap on the tank. Use a siphon or similar pump that is suitable for fuel to suck all of the fuel out of the tank. Pour a little clean diesel or paraffin into the tank and rinse out. Empty the tank completely. Never mix water through the fuel as this will rust the tank! Fireball 37T: Place the heater on a work bench or similar and place a fuel container under the fuel tank. Undo the drain nut and let the fuel and any water or dirt drain out. Pour a little clean diesel or paraffin into the tank and rinse out. Empty the tank completely. Once the tank is completely empty, tighten the nut and clean up any spilt dirt or fuel from the heater. Never leave fuel sitting in the tank if the heater is to be out of use for a while; old
fuel can damage the heater! Store the heater in a safe, dry and well-ventilated location, outside the reach of
children. Make sure that the storage area is not dusty and does not contain any corrosive
vapours Store the heater in the original packing Store the instruction booklet in an accessible place
Warning! Air pollution that is sucked into the heater can impact upon the heat if gives off, damage the heater and lead to health problems. For example: plaster dust or paint chips can damage the engine bearings or block the filters and contaminate the combustion chamber; this will lead to an irregular flame and could pose a risk to health. This type of damage is not covered by the guarantee and any costs for cleaning the heater will have to be paid in full.
The degree of maintenance work that has to be carried out is largely dependent on the level of contamination in the area in which the heater is used. The frequency indicated is calculated on the basis of a clean room; if the heater is used in a dusty environment, maintenance should be carried out more frequently in order to extend the lifetime of the heater. If parts have to be replaced, always ensure that original parts are used! The use of alternate or third part components can cause unsafe operating conditions, and will void your warranty.

Fuel and fuel tank Rinse the tank after every 200 hours of operation or more frequently if necessary. Do not use water to clean the tank; only use top quality, fresh paraffin. Filters Air intake filter: After a maximum of 500 operational hours, wash in a mild, soapy solution and dry thoroughly or replace. Do so more often if used in dusty environments! Air intake filter/lint filter: Replace after a maximum of 500 operational hours or once a year if used in a dusty environment. NB: when using diesel, extra maintenance may be required Fan blades Clean at least once a season or whenever necessary. Clean the fan with a soft cloth, slightly moistened with a gentle soapy solution. Be careful not to move the blades out of position and check that they are rotating correctly after restarting the heater. Nozzle Clean the nozzle as often as required, but at least once per season. Contaminated fuel may mean the nozzle will have to be cleaned immediately. In order to remove dirt, use a compressor to blow air from the front of the nozzle. Soak in clean paraffin in order to remove any stubborn dirt.




Spark plug Clean the sparkplug with a wire brush and adjust it, or replace it, after a maximum of 600 operational hours; the opening must be 3.5 mm. Photo-electric cell Clean the photoelectric cell as often as required but at least once a year. Clean the lens with a cotton swab, possibly dampened with a little water or alcohol. See the diagram for the correct photo cell position. Fuel filter Clean or replace at least twice a season and more frequently if necessary. You may clean the fuel filter with clean fuel but you are advised to replace the old filter with a new one. Open the clips with tongs and remove the old filter. Slide the hoses over the new filter and close the clips. The use of diesel or dirty fuel can lead to the filter having to be cleaned more frequently or immediately. One extra filter is supplied with the standard package. Adjusting pressure on compressor pump In order to alter the pressure on the compressor pump (on a working heater), use a screwdriver to adjust the pressure regulator (see diagram). Clockwise = higher pressure; anti- clockwise = lower pressure. The correct pump pressure is: Fireball 20T: 3.5Psi (0.25bar) Fireball 37T: 6.0Psi (0.43bar) (Tolerance: ± 10%). To achieve the best result, measure with a full tank. The pressure is best if the cone (flame deflector) is cherry red and no flames are directed outwards.




The heater burns but switches off after a short period The light blinks, display shows E1 Incorrect pump pressure Dirty air filter Dirty fuel filter Nozzle dirty Photoelectric cell lens dirty Photoelectric cell not installed correctly Photoelectric cell defective Bad electrical connection between
Check pump pressure and adjust if
necessary Clean/replace air filter Clean/replace fuel filter Clean/replace nozzle Clean the lens Install correctly Check and replace photoelectric cell
if necessary Check electrical connection and repair where necessary The heater is not working or the motor runs for a short time only. The light blinks, display shows E2 No fuel in the tank Incorrect pump pressure Spark plug dirty or plug opening
photo cell and PCB
Add fuel Adjust pump pressure Clean spark plug, adjust or replace
incorrect Dirty fuel filter Nozzle dirty Dirt in fuel or tank
Clean/replace fuel filter Clean/replace nozzle Replace fuel and clean tank with
Bad electrical connection between
paraffin Check all connections, see wiring
transformer and operating panel Ignition wire not connected to spark
diagram Connect the ignition cable to the
spark plug Replace the ignition The fan does not work but the heater comes on. The light blinks or stays on and the display shows E1 or E2 Thermostat settings too low Electrical connection between the
Set thermostat higher Check all electrical connections
operating panel and motor is broken
Bad combustion or excess formation of soot Dirty inlet, outlet or lint filter Dirty fuel filter Bad fuel quality Pressure is too high or low
Clean or replace filters Clean or replace filter Do not use dirty or old fuel Set the right setting
plug Broken ignition

The heater does not work and the light does not come on The sensor has detected overheating No electricity Fuse is broken Bad electrical connection between
Switch off heater and leave to cool for
10 minutes. Switch it off and on again. Check the electricity supply and
connections to electric and extension cable. Replace the fuse Check all connections, see wiring
temperature sensors and operating panel
diagram.


4-6 Fuel line Fitting 15-004-0106 4-7 Air line Fitting 15-004-0107 4-8 Spark Plug Kit 15-004-0108 5 Ignitor Wire 15-005-0100 6 Fan Assembly 15-006-0100 7 Motor and Pump
7-1 Motor 15-007-0101 7-2 Pump Body 15-007-0102 7-3 Conncetor 15-007-0103 7-4 Rotor Kit 15-007-0104 7-5 Blade 15-007-0105 7-6 End Pump Cover 15-007-0106 7-7 Lint Filter 15-007-0107 7-8 Rubber Mat 15-007-0108 7-9 Output Filter 15-007-0109 7-10 End Filter Cover 15-007-0110 7-11 Air Pressure Gauge 15-007-0111 7-12 Intake Filter 15-007-0112 7-13 Adjusting Screw 15-007-0113 7-4 Spring 15-007-0114 7-15 Ball 15-007-0115 8 Fan Guard 15-008-0100 9 Motor Bracket 15-009-0100 10 Ignitor 15-010-0100 11 Left Side Cover 15-011-0100 12 Capacitor 15-012-0100 13 Grounding plate 15-013-0100 14 Fixation Part 15-014-0100 15 Fuel Cap 15-015-0100 16 Fuel Gauge 15-016-0100 17 Fuel Tank 15-017-0100 18 Power Cord 15-018-0100 19 Cord Bushing 15-019-0100 20 Supporting Bracket 15-020-0100 21 PCB Bracket 15-021-0100 22 Room Sensor 15-022-0100 23 Fuse 15-023-0100 24 Main PCB Assembly 15-024-0100 25 Thermostat Control Knob 15-025-0100 26 Power Switch 15-026-0100 27 Right Side Cover 15-027-0100 28 Window Display 15-028-0100 29 Fuel Filter Assembly 15-029-0100 30 Lower Shell 15-030-0100 31 Thermostat Limit Control 15-031-0100 32 Thermostat Bracket 15-032-0100 33 Clip Nut 15-033-0100 34 Fuel line Hose 15-034-0100 35 Air line Hose 15-035-0100 36 Photocell Assembly 15-036-0100 37 Photocell Bracket 15-037-0100
15-007-0100 · Assembly



2 Upper Shell 30-002-0100 3 Burner Head Assembly 30-003-0100 3-1 Nozzle Kit 30-004-0101 3-2 Nozzle Seal Spring 15-004-0102 3-3 Nozzle Seal Washer 15-004-0103 3-4 Nozzle Sleeve 15-004-0104 3-5 Burner Head 30-004-0102 3-6 Fuel line Fitting 15-004-0107 3-7 Air line Fitting 15-004-0107 3-8 Spark Plug Kit 15-004-0108 4 Igniter Wire 15-005-0100

5 Fan Assembly 30-005-0200 6 Motor and Pump
6-1 Motor 15-007-0101 6-2 Pump Body 15-007-0102 6-3 Connector 15-007-0103 6-4 Rotor Kit 30-006-0201 6-5 Blade 15-007-0105 6-6 End Pump Cover 15-007-0106 6-7 Lint Filter 15-007-0107 6-8 Rubber Mat 15-007-0108 6-9 Output Filter 15-007-0109 6-10 End Filter Cover 15-007-0110 6-11 Air Pressure Gauge 15-007-0111 6-12 Intake Filter 15-007-0112 6-13 Adjusting Screw 15-007-0113 6-14 Spring 30-006-0102 6-15 Ball 15-007-0115 7 Fan Guard 15-008-0100 8 Motor Bracket 30-007-0100 9 Igniter 15-010-0100 10 Left Side Cover 30-008-0100 11 Capacitor 15-012-0100 12 Grounding plate 15-013-0100 13 Fixation Part 15-014-0100 14 Fuel Tank 30-009-0100 15 Power Cord 15-018-0100 16 Cord Bushing 15-019-0100 17 Supporting Bracket 30-010-0100 18 PCB Bracket 15-021-0100 19 Room Sensor 15-022-0100 20 Fuse 15-023-0100 21 Main PCB Assembly 15-024-0100 22 Thermostat Control Knob 15-025-0100 23 Power Switch 15-026-0100 24 Right Side Cover 30-011-0100 25 Window Display 15-028-0100 26 Fuel Cap 15-015-0100 27 Fuel Gauge 30-012-0100 28 Fuel Filter Assembly 30-013-0100 29 Lower Shell 30-014-0100 30 Thermostat Limit Control 15-031-0100 31 Thermostat Bracket 15-032-0100 32 Clip Nut 15-033-0100 33 Fuel line Hose 30-015-0100 34 Air line Hose 30-016-0100 35 Photocell Assembly 15-036-0100 36 Photocell Bracket 15-037-0100
30-006-0100 · Assembly
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.