NL
Ferm logo
Officiële handleiding

Ferm CRM1047S

36 pagina's·4.2 MB·Compressoren·PDF·ENITJA
Ferm CRM1047S
Inhoudsopgave 20 secties CRM1047S · DE · NL · FR · … TonenVerbergen
Page 1 of the Ferm CRM1047S user manual — www.ferm.com
Pagina 1 · klik om te vergroten
Pagina 1
Ferm CRM1047S — CRM1047S diagram (page 1)
Afb. 1
Ferm CRM1047S — CRM1047S diagram (page 1)
Afb. 2
Ferm CRM1047S — CRM1047S diagram (page 1)
Afb. 3

CRM1047S

DE

Übersetzung der Originalbetriebsanleitung 09

NL

Vertaling van de oorspronkelijke gebruiksaanwijzing 14

Traduction de la notice originale 19

FR

ES

Traducción del manual original 23

HU

Eredeti használati utasítás fordítása 28

www.ferm.com

Original instructions 05

Page 2 of the Ferm CRM1047S user manual — Fig. A
Pagina 2 · klik om te vergroten
Pagina 2
Ferm CRM1047S — Fig. A diagram (page 2)
Afb. 4 · Fig. A
Ferm CRM1047S — Fig. A diagram (page 2)
Afb. 5 · Fig. A

Fig. A

Page 3 of the Ferm CRM1047S user manual — Fig. F
Pagina 3 · klik om te vergroten
Pagina 3
Ferm CRM1047S — Fig. F diagram (page 3)
Afb. 6 · Fig. F

Fig. F

Page 4 of the Ferm CRM1047S user manual — Fig. F
Pagina 4 · klik om te vergroten
Pagina 4
Ferm CRM1047S — Fig. F diagram (page 4)
Afb. 7 · Fig. F
Page 5 of the Ferm CRM1047S user manual — 1. Machine details
Pagina 5 · klik om te vergroten
Pagina 5

Compressor 1.5HP - 1100W - 24L

13. Tank 14. Air filter 15. Overload switch 16. Quick coupler (tank outlet pressure)

The numbers in the following text correspond with the pictures at page 1 - 4.

Read the operating instructions carefully before using this device. Familiarise yourself with its functions and basic operation. Service the device as per the instructions to ensure that it always functions properly. The operating instructions and the accompanying documentation must be kept in the vicinity of the device.

2. Safety instructions

Denotes risk of personal injury, loss of life or damage to the tool in case of non- observance of the instructions in this manual.

Contents 1. Machine details 2. Safety instructions 3. Use 4. Maintenance

Risk of electric shock.

1. Machine details

Wear ear protection.

Voltage 230 V~ Frequency 50 Hz Capacity 1.5 hp (1100 W) Idling speed 2850/min IP Class IP 20 Tank contents 24litre Air intake 161 l/min Max. outlet pressure 8.0 Bar Weight 22.7 kg Sound power level 93.0 dB (A)

  • Special safety instructions
  • Warning! The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +0°C to +40°C).
  • Check that the tank is fully decompressed before connections with the tank are unscrewed.
  • It is prohibited to make holes in, or welds to, or purposely to distort the compressed air tank.
  • Do not perform any actions on the compressor without first having taken the power plug out of the plug socket.
  • Do not aim water jets or jets of flammable liquids at the compressor.
  • Do not place flammable objects near the compressor.
  • Switch the switch (3) to the “0” position (OFF) during dwell time (fig. 11).
  • Never aim the air jet at persons or animals (fig. 20).
  • Do not transport the compressor with the tank pressurised.
  • N.B.: some parts of the compressor such as

The value of the noise level may rise from 1 to 10 dB(A) as a function of the environment in which the compressor will be installed.

Product information Fig. A 1 Cover 2. Handle 3. Switch button 4. Automatic stop switch 5. Pressure regulator 6. Quick coupler (outlet) 7. Quick coupler (outlet regulated pressure) 8. Pressure gauge (tank pressure) 9. Pressure gauge regulated pressure 10. Drain cock 11. Wheel 12. Rubber feet

Explanation of symbols · Technical specifications · Sound power level

Page 6 of the Ferm CRM1047S user manual — 3. USE
Pagina 6 · klik om te vergroten
Pagina 6
  • the head and the feed-through pipes may reach high temperatures. Do not touch these parts to avoid burns (fig. 12-13).
  • Transport the compressor by lifting it or by using the special grips or handles (fig. 5-6).
  • Children and animals should be kept far away from the area of operation of the machine.
  • If you use the compressor to spray paint: a) Do not work in enclosed spaces or near naked

Before replacing the plug of the feed, make sure that the earth cable is connected. If in doubt, please call in a qualified electrician and have the earthing checked.

Electrical connection Always check whether the input voltage of the motor corresponds to the mains voltage indicated on the specification plate. The compressors are supplied with an electrical cable and a two-pole plug + earth. It is important to connect the compressor with an earthed plug socket. (fig. 9)

flames. b) Make sure that the environment in which you

will be working has dedicated ventilation. c) Protect your nose and mouth with a dedicated

  • mask (fig. 21).
  • Do not use the compressor when the electrical cable or the plug is damaged, and instruct an authorised Support Service to replace them with an original part.
  • When the compressor is placed on a surface higher than the floor, it should be secured to prevent it from falling down during operation.
  • Do not put objects or your hands in the protective covers to avoid physical damage and damage to the compressor.
  • Do not use the compressor as a blunt instrument against persons, objects or animals in order to prevent serious damage.
  • If the compressor is no longer in use, always take the plug out of the plug socket.
  • Always make sure that compressed-air hoses are used for compressed air and which are characterised by a maximum pressure adjusted to that of the compressor. Do not try to repair the hose if it is damaged.

Never use the earth-wire instead of the neutral (0-wire). The earthing should take place in accordance with accident prevention regulations.

Power supply • The motor is fitted with an overload switch (15). If the compressor overloads, the overload switch switches the equipment off automatically to protect the compressor from overheating. If the overload switch triggers, switch off the compressor using the ON/OFF switch (8) and wait until the compressor cools down. Then press the overload switch (15) and restart the compressor.

3. USE

For homehold use only

NB: The information you will find in this manual has been written to assist the operator in the use and maintenance of the compressor. Some illustrations in this manual show details which may differ from those of your compressor.

Earthing regulations This compressor has to be earthed while in use in order to protect the operator against electrical shocks. The compressor is provided with a two- core cable plus an earth. The electrical connection has to be made by a qualified technician. We recommend never disassembling the compressor and neither making any other connections into the pressure regulator. Repairs should be carried out by authorised Support Services or by other qualified centres.

Installation After having taken the compressor out of its packaging (fig. 1) and having checked that it is in perfect condition, and having noted that no damage occurred during transport, the following acts should be performed. If not yet fitted, fit the rubber feet and the wheels on the tank according to the instructions represented in fig. 2. Place the compressor on a flat surface or at a maximum slope of 10° (fig.3), in a well ventilated area, protected against atmospheric factors and not in explosive surroundings. If the surface area is sloping and smooth, make sure that the

Never forget that the earthing core is the green or the yellow/green wire. Never connect this green wire to a terminal under load.

Electrical safety

Page 7 of the Ferm CRM1047S user manual — 4. Maintenance
Pagina 7 · klik om te vergroten
Pagina 7

compressor will not move when in operation. If the surface area is a board or a shelf of a bookcase, just make sure that they cannot fall down by securing them properly. For proper ventilation and effective cooling, it is important that the compressor is positioned at least 100 cm from the wall (fig. 4).

  • valve it is necessary to set the operating pressure properly. It is possible to set the operating pressure by using the turning knob on the reduction valve.
  • By turning clockwise, the pressure will be increased.
  • By turning anti-clockwise, the pressure will be reduced.

Make sure that the compressor is transported in the right way, do not turn it upside down and don’t lift it with hooks or ropes (fig. 5-6).

  • The compressor has two pressure gauges and two points to connect an air hose:
  • Pressure gauge on the left (9): pressure on left outlet (7). The pressure of left this outlet can be regulated with help of the reduction valve (5).
  • Pressure gauge on the right (8): tank pressure + pressure on right outlet (6)

Installing the air filter. Remove the transport lids and replace them with the supplied air filter before using the compressor

  • Starting up
  • Check whether the mains voltage corresponds to that indicated on the electrical specification plate (fig. 10), the permitted tolerance range should be within 5%.
  • Press the switch (3) situated on the upper part into the “0” position according to the pressure regulator type fitted on the device (fig. 11).
  • Put the plug in the plug socket (fig. 9) and start the compressor up by putting the switch of the pressure regulator in the “I” position. The operation of the compressor is fully automatic. The pressure regulator will stop the compressor when the maximum value has been reached and start it up when the pressure drops below the minimum value. Normally the difference in pressure is approx. 2 Bar/29 psi between the maximum and the minimum value. For instance - The compressor will stop when it reaches 8 Bar (116 psi) (this is the maximum operating pressure) and will start up automatically when the pressure within the tank has dropped to 6 Bar (87 psi).
  • Hints for accurate adjustment of the pressure regulation:
  • Turn the turning knob (5) anti-clockwise till pressure is fully released
  • -Connect the air tool you want to use to the left quick coupler (6)
  • Activate the air too shortly, so the pressure gauge (7) will show the right pressure level
  • Turn the turning knob (5) clockwise, till the pressure gauge (7) shows the pressure level you need
  • Your air tool is now ready to use.

4. Maintenance

Make sure that the power plug is removed from the mains when carrying out maintenance work on the motor.

The head/cylinder/transmission pipe assembly may reach high temperatures, so take care when working close to these parts and do not touch them to avoid burns (fig. 12 - 13).

  • The machine has been designed to operate over a long period of time with a minimum of maintenance. Continuous satisfactory operation depends upon proper machine care and regular cleaning. Before interfering in any way whatsoever with the compressor, please make sure that:
  • The switch button (3) is in the “0” position and the power plug is removed from the power socket
  • The air tank is fully decompressed (both pressure gauges must be pointed at 0 Bar)

Adjusting the operating pressure Fig. 14 It is not necessary continuously to use the maximum operating pressure, the compressed-air tools often require less pressure. With regard to compressors supplied with a pressure reduction

Page 8 of the Ferm CRM1047S user manual — 4. Maintenance
Pagina 8 · klik om te vergroten
Pagina 8
  • tank corrosion (fig 16):
  • First reduce the pressure in the tank till aprroxially 2 bar by connecting and activating an air tool .
  • Then slowly turn the drain valve (11) on the lower side of the tank open.
  • The water in the tank will now leak out of the tank Take care when compressed air is in the tank because the water can come out with some force. Recommended pressure max. 1-2 Bar.

Malfunction Should the machine fail to function correctly, a number of possible causes and the appropriate solutions are given below:

  • Air loss
  • May be caused by a poor seal of a connection.
  • Check all air connections by wetting them with a soapy water solution ( Never use the solution nearby electric connections )
  • When the tank is empty and being filled. The user might hear a sisseling sound by the pressure switch. This is normal and will stop before the compressor reach a pressure of 1.5 bar
  • Check if the drain valve (11) is closed well

Clean the air filter It is recommended to disassemble the suction filter every 50 operating hours and to clean the filter element by blowing it with compressed air (fig. 15). It is recommended that the filter element is replaced at least once a year if the compressor is working in a clean environment; more often if the environment in which the compressor is situated is dusty.

  • The compressor will not start
  • If the compressor is difficult to start, check:
  • whether the voltage of the mains corresponds to that on the specification plate (fig. 10)
  • whether electrical extension cables are being used with a faulty core or length.
  • whether the operating environment is too cold (below 0°C).
  • whether there is electricity supply (plug properly connected, magneto-thermal fuses not broken).

Lubrication It is recommended to disassemble the suction filter every 50 operating hours and to clean the filter element by blowing it with compressed air (fig. 15). It is recommended that the filter element is replaced at least once a year if the compressor is working in a clean environment; more often if the environment in which the compressor is situated is dusty. The compressor makes condensed water which collects in the tank. It is necessary to remove the condensed water in the tank at least once a week by opening the drain cock (fig. 16) under the tank. Take care when compressed air is in the bottle because the water can come out with some force. Recommended pressure max. 1-2 Bar.

The compressor does not shut off If the compressor does not shut off when the maximum pressure has been reached, the safety valve of the tank will be activated. It is necessary to contact the nearest authorised Support Service for the repair.

Repairs and servicing should only be carried out by a qualified technician or service firm.

Faults Should a fault occur, e.g. after wear of a part, please contact the service address on the warranty card. In the back of this manual you find an exploded view showing the parts that can be ordered.

Cleaning Regularly clean the machine housing with a soft cloth, preferably after each use. Keep the ventilation slots free from dust and dirt. If the dirt does not come off use a soft cloth moistened with soapy water. Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may damage the plastic parts.

Environment To prevent damage during transport, the appliance is delivered in a solid packaging which consists largely of reusable material. Therefore please make use of options for recycling the packaging.

Drain the tank Compressing air will cause water in the tank. Regularly drain the water from the tank to prevent

Page 9 of the Ferm CRM1047S user manual — Spare parts list
Pagina 9 · klik om te vergroten
Pagina 9

Spare parts list

CRM1047S Compressor

No. Description Position 502081 Valve and gasket set 5,6,7 502082 Piston and cylinder 8,10-13 806005 Bearing 6005 zz 19 806204 Bearing 6204 zz 24 806202 Bearing 6202 zz 27 502083 Capacitor 35uF 40 502084 Air filter 46 502085 Cover 47 502086 Wheel ( 1 wheel p. set) 72+57-60 502087 Non return valve 61 502088 Drain valve 62 502089 Rubber foot 63 502090 Quick coupler 66 502091 Reduce valve and connector 67 502092 Pressure gauge 68 502093 Safety valve 69 502094 Automatic pressure switch 70 ATA1025 Air accessory set ATA1026 5m air hose coiled + couplings ATA1027 10m air hose + couplings ATA1033 Compressor hose reel ATM1036 FAT-850 Air tool set, 5 pcs ATM1037 FBG-500 Blow gun ATM1038 FBG-510 Blow gun, long nozzle ATM1039 FSG-500 Paint spray gun, ATM1040 FSG-510 Paint spray gun, ATM1041 FTI-450 Tyre inflator ATM1042 FPT-200 Tacker, pneumatic ATM1044 FAN-100K 50mm Air Nailer Kit

Page 10 of the Ferm CRM1047S user manual — Exploded view
Pagina 10 · klik om te vergroten
Pagina 10

Exploded view

Page 11 of the Ferm CRM1047S user manual — EN1012-1, EN60204-1, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3
Pagina 11 · klik om te vergroten
Pagina 11

DECLARATION OF CONFORMITY

CRM1047S compressor

(EN) We declare under our sole responsibility that this product is in conformity with

(CZ) Na naši vlastní zodpovědnost prohlašujeme, že je tento výrobek v souladu s

directive 2011/65/EU of the European parliament and of the council of 9 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations: (DE) Der Hersteller erklärt eigenverantwortlich, dass dieses Produkt der Direktive

následujícími standardy a normami: Je v súlade s normou 2011/65/EÚ Európskeho parlamentu a Rady z 8. júna 2011 týkajúcej sa obmedzenia používania určitých nebezpečných látok v elektrickom a elektronickom vybavení. (SK) Vyhlasujeme na našu výhradnú zodpovednosť, že tento výrobok je v zhode a súlade

s nasledujúcimi normami a predpismi: Je v súlade s normou 2011/65/EÚ Európskeho parlamentu a Rady z 8. júna 2011 týkajúcej sa obmedzenia používania určitých nebezpečných látok v elektrickom a elektronickom vybavení. (SL) S polno odgovornostjo izjavljamo, da je ta izdelek v skladu in da odgovarja

2011/65/EU des Europäischen Parlaments und des Rats vom 8. Juni 2011 über die Einschränkung der Anwendung von bestimmten gefährlichen Stoffen in elektrischen und elektronischen Geräten entspricht. den folgenden Standards und Vorschriften entspricht: (NL) Wij verklaren onder onze volledige verantwoordelijkheid dat dit product voldoet aan

naslednjim standardom terpredpisom: je v skladu z direktivo 2011/65/EU Evropskega parlamenta in Sveta z dne 8. junij 2011 o omejevanju uporabe določenih nevarnih snovi v električni in elektronski opremi. (PL) Deklarujemy na własną odpowiedzialność, że ten produkt spełnia wymogi zawarte w

de conform Richtlijn 2011/65/EU van het Europees Parlement en de Raad van 8 juni 2011 betreffende beperking van het gebruik van bepaalde gevaarlijke stoffen in elektrische en elektronische apparatuur en in overeenstemming is met de volgende standaarden en reguleringen: (FR) Nous déclarons sous notre seule responsabilité que ce produit est conforme aux

następujących normach i przepisach: jest zgodny z Dyrektywą 2001/65/UE Parlamentu Europejskiego i Rady z dnia 8 czerwca 2011 r. w sprawie ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym. (LT) Prisiimdami visą atsakomybę deklaruojame, kad šis gaminys atitinka žemiau

standards et directives suivants: est conforme à la Directive 2011/65/EU du Parlement Européen et du Conseil du 8 juin 2011 concernant la limitation d’usage de certaines substances dangereuses dans l’équipement électrique et électronique. (ES) Declaramos bajo nuestra exclusiva responsabilidad que este producto cumple con

paminėtus standartus arba nuostatus: atitinka 2011 m. birželio 8 d. Europos Parlamento ir Tarybos direktyvą 2011/65/EB dėl tam tikrų pavojingų medžiagų naudojimo elektros ir elektroninėje įrangoje apribojimo. (LV) Ir atbilstoša Eiropas Parlamenta un Padomes 2011. gada 8. jūnija Direktīvai

las siguientes normas y estándares de funcionamiento: se encuentra conforme con la Directiva 2011/65/UE del Parlamento Europeo y del Consejo de 8 de junio de 2011 sobre la restricción del uso de determinadas sustancias peligrosas en los equipos eléctricos y electrónicos. (PT) Declaramos por nossa total responsabilida-de que este produto está em

2011/65/ES par dažu bīstamu vielu izmantošanas ierobežošanu elektriskās un elektroniskās iekārtās. (ET) Apgalvojam ar visu atbildību, ka šis produkts ir saskaņā un atbilst sekojošiem

conformidade e cumpre as normas e regulamentações que se seguem: está em conformidade com a Directiva 2011/65/EU do Parlamento Europeu e com o Conselho de 8 de Junho de 2011 no que respeita à restrição de utilização de determinadas substâncias perigosas existentes em equipamento eléctrico e electrónico. (IT) Dichiariamo, sotto la nostra responsabilità, che questo prodotto è conforme alle

standartiem un nolikumiem: ir atbilstoša Eiropas Parlamenta un Padomes 2011. gada 8. jūnija Direktīvai 2011/65/ES par dažu bīstamu vielu izmantošanas ierobežošanu elektriskās un elektroniskās iekārtās. (RO) Declarăm prin aceasta cu răspunderea deplină că produsul acesta este în

conformitate cu următoarele standarde sau directive: este în conformitate cu Directiva 2011/65/UE a Parlamentului European şi a Consiliului din 8 iunie 2011 cu privire la interzicerea utilizării anumitor substanţe periculoase la echipamentele electrice şi electronice. (HR) Izjavljujemo pod vlastitom odgovornoĻśu da je strojem ukladan sa slijedeśim

normative e ai regolamenti seguenti: è conforme alla Direttiva 2011/65/UE del Parlamento Europeo e del Consiglio dell’8 giugno 2011 sulla limitazione dell’uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche. (SV) Vi garanterar på eget ansvar att denna produkt uppfyller och följer följande

standardima ili standardiziranim dokumentima i u skladu sa odredbama: usklađeno s Direktivom 2011/65/EU europskog parlamenta i vijeća izdanom 8. lipnja 2011. o ograničenju korištenja određenih opasnih tvari u električnoj i elektroničkoj opremi. (SRL)Pod punom odgovornošću izjavljujemo da je usaglašen sa sledećim standardima ili

standarder och bestämmelser: uppfyller direktiv 2011/65/EU från Europeiska parlamentet och EG-rådet från den 8 juni 2011 om begränsningen av användning av farliga substanser i elektrisk och elektronisk utrustning. (FI) Vakuutamme yksinomaan omalla vastuullamme, että tämä tuote täyttää seuraavat

normama: usaglašen sa direktivom 2011/65/EU Evropskog parlamenta i Saveta od 8.juna.2011. godine za restrikciju upotrebe određenih opasnih materija u električnoj i elektronskoj opremi. (RU) Под свою ответственность заявляем, что данное изделие соответствует

standardit ja säädökset: täyttää Euroopan parlamentin ja neuvoston 8. kesäkuuta 2011 päivätyn direktiivin 2011/65/EU vaatimukset koskien vaarallisten aineiden käytön rajoitusta sähkö- ja elektronisissa laitteissa. (NO) Vi erklærer under vårt eget ansvar at dette produktet er i samsvar med følgende

следующим стандартам и нормам: соответствует требованиям Директивы 2011/65/EU Европейского парламента и совета от 8 июня 2011 г. по ограничению использования определенных опасных веществ в электрическом и электронном оборудовании (UK) На свою власну відповідальність заявляємо, що дане обладнання відповідає

standarder og regler: er i samsvar med EU-direktivet 2011/65/EU fra Europa-parlamentet og Europa-rådet, pr. 8 juni 2011, om begrensning i bruken av visse farlige stoffer i elektrisk og elektronisk utstyr. (DA) Vi erklærer under eget ansvar, at dette produkt er i overensstemmelse med følgende

standarder og bestemmelser: er i overensstemmelse med direktiv 2011/65/EU fra Europa-Parlamentet og Rådet af 8. juni 2011 om begrænsning af anvendelsen af visse farlige stoffer i elektrisk og elektronisk udstyr. (HU) Felelősségünk teljes tudatában kijelentjük, hogy ez a termék teljes mértékben

наступним стандартам і нормативам: задовольняє вимоги Директиви 2011/65/ ЄС Європейського Парламенту та Ради від 8 червня 2011 року на обмеження використання деяких небезпечних речовин в електричному та електронному обладнанні.

megfelel az alábbi szabványoknak és előírásoknak: je v souladu se směrnicí 2011/65/EU Evropského parlamentu a Rady EU ze dne 8. června 2011, která se týká omezení použití určitých nebezpečných látek v elektrických a elektronických zařízeních.

EN1012-1, EN60204-1, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3

2011/65/EU, 2012/19/EU, 2006/42/EC, 2004/108/EC, 87/404/eec, 2000/14/ec

Zwolle, 01-04-2015 H.G.F. Rosberg CEO Ferm B.V.

  • Ferm BV
  • Lingenstraat 6
  • 8028 PM
  • Zwolle The Netherlands
Page 12 of the Ferm CRM1047S user manual — DECLARATION OF CONFORMITY
Pagina 12 · klik om te vergroten
Pagina 12

www.ferm.com ©2015 FERm B.V.

1504-10

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Ferm CRM1047S

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Ferm CRM1047S

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Ferm CRM1047S handleiding-pdf

36 pagina's·4.2 MB·Compressoren·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…