© Novar Electrical Devices and Systems Limited (a Honeywell Company) 2013 50083202-001 The Arnold Center, Paycocke Road, Basildon, Essex, SS14 3EA (UK) Rev. A

The FGGA0401WWE / FGGA04* Series solar siren is suitable for use with Friedland wireless alarm systems operating at 868 MHz only. The siren uses a high-capacity, rechargeable main battery (NiMH). The solar panel on top of the housing charges the battery during daylight hours. During darkness, only a small amount of energy is required to operate the siren. The siren is supplied with an initial power-up battery (alkaline) to boost the initial power to the siren when the system is first activated until the solar panel charges the rechargeable main battery. The tamper switch will immediately trigger an alarm if any unauthorised attempt is made to interfere with and remove the siren cover. An anti-jamming detection system will generate an alarm if any attempt is made to continuously jam the radio channel used for the system.
2.1 Product
Keep all safety warnings and instructions for future reference. Obey the local regulations applicable to the installation of the product. Do not attempt to open the devices.
Wear safety gloves when drilling into walls. Wear safety glasses when drilling into walls. Make sure that there are no electrical wires and water pipes when drilling into walls. Position ladders onto a level and stable surface and at a safe angle.
3.1 Package contents





5.1 Configuring the siren



Make sure that the solar panel receives sufficient light to maintain the battery charge.
If you set up the siren without separate control panel (single zone) for the first time, you must link the siren to a remote keypad or a remote control before adding other devices. The ID code of the remote control or the remote keypad must be learned by the siren. The siren can learn up to 6 remote controls or remote keypads. During setup, the siren will power up in service mode, ready to learn a new remote control or remote keypad. If the siren is in operating mode, refer to the section “Service mode / Operating mode” to switch to service mode.


In order to communicate with the siren, the ID code of the security detector must be learned by the siren. The siren can learn up to 12 security detectors (door/window contact detectors or PIR movement detectors). During setup, the siren will automatically power up in service mode, ready to learn a new security detector. If the siren is in operating mode, refer to the section “Service mode / Operating mode” to switch to service mode.
If you install the siren for the first time, it will automatically power up in service mode. Before testing or operating the siren, it must be switched into operating mode. If you use the siren with a control panel, refer to the Installation and Operation Manual for the alarm system. If you use the siren without a control panel, use the remote control or the remote keypad:

This section only describes the operation of the siren when operating without control panel (single zone).
When leaving the premises, the system must be armed. Make sure that the siren is in operating mode. Before arming the system, make sure that all doors and windows are closed and that the available PIR movement detectors are not obstructed. Make sure that animals are restricted to areas not protected by PIR movement detectors.
6.1.1 Instant-arm mode
The instant-arm mode will immediately arm the system. If the system is armed, activating any security detector will immediately trigger an alarm. When entering the premises, disarm the system before opening any door or window protected by a door/window contact detector or entering an area protected by a PIR movement detector. In the instant-arm mode, arm and disarm the system from outside the premises using the remote control or the remote keypad.
6.1.2 Delay-arm mode
The delay-arm mode will arm the system with a 15-second entry/exit delay. The siren will emit one beep and another beep after the 15-second delay has expired to allow time to leave the premises before the system is fully armed. When entering the premises by opening any door or window protected by a door/window contact detector or entering an area protected by a PIR movement detector, the system will be triggered and the siren will emit one long beep. However, the alarm will not sound until the 15-second delay has expired. Disarm the system using the remote control or the remote keypad during the 15-second delay. If an alarm occurs, the siren will sound continuously until the set alarm duration time expires. The alarm will stop and the system will re-arm. The alarm lockout feature will prevent the system from re-arming after repeating the process three times.


The user can trigger an alarm at any time in the event of threat or danger by activating the personal attack facility.

If the battery cover of any device (except remote controls) is removed or if the siren or the remote keypad is removed from the wall, an alarm will occur immediately even if the system is disarmed (unless the siren is in service mode). The alarm will sound until the set alarm time expires or the system is disarmed from the remote control or the remote keypad.

If you press the button on the remote control or the remote keypad when the siren is at low-battery condition, the siren will emit three short beeps. If a low-battery indicator is activated, the device will continue to operate for up to 2 weeks. Replace the battery as soon as possible. Before replacing the battery, switch the system into service mode. After replacing the battery, switch the system back into operating mode.
The alarm system requires little maintenance. If you must power down the system completely, switch the system into service mode before removing the siren cover and disconnecting the rechargeable main battery and the initial power-up battery. Make sure that the solar panel is covered with a lightproof material to prevent the solar panel from powering the siren.
The product is classified by the Waste Electrical or Electronic Equipment (WEEE) directive. The product and the batteries of the monitor should not be disposed of with other household or other commercial waste. At the end of its useful life, the packaging and the product should be disposed of via a suitable recycling centre. For information on available facilities, please contact your local authority or retailer from where the product was purchased.
Novar ED&S hereby declares that the product is in compliance with the essential requirements and other relevant provisions of the Radio and Telecommunications Terminal Equipment (R&TTE) directive (1995/5/EC).
Novar ED&S undertakes to replace or repair at its discretion goods, should they become defective within 2 year solely as a result of faulty materials and workmanship. Understandably, if the product has not been installed, operated or maintained in accordance with the instructions, if the product has not been used appropriately or if any attempt has been made to rectify, dismantle or alter the product in any way, the guarantee will be invalidated. The guarantee states Novar ED&S entire liability. The guarantee does not extend to cover consequential loss or damage or installation costs arising from the defective product. The guarantee does not in any way affect the statutory or other rights of a consumer and applies to products installed within the EU only. If an item develops a fault, the product must be returned to the point of sale with:

For further product information and full installation manuals where applicable go to www.friedlandproducts.com
The phone calls are charged
Service Helpline UK & Northern Ireland 0844 736 9149 Monday to Friday 9:00 am - 5:00 pm
at the national rate of the
service providers.

1 Bestimmungsgemäßer Gebrauch 13 2 Sicherheit 13
2.1 Produkt 13 2.2 Installation 13
3 Beschreibung 13
3.1 Verpackungsinhalt 13 3.2 Erforderliche Werkzeuge 14
4 Übersicht 14 5 Installation 15
5.1 Konfiguration der Sirene 15 5.2 Hochfahren der Sirene 15 5.3 Hinzufügen einer neuen Fernbedienung oder eines neuen Funk-Bedien-/Tastenfeldes zur Sirene 16 5.4 Befestigung der Sirene an der Wand 17 5.5 Hinzufügen eines neuen Melders zur Sirene 18 5.6 Löschen aller Geräte aus der Sirene 18 5.7 Servicemodus / Betriebsmodus 18
6 Bedienung 19
6.1 Scharfstellen der Anlage 19
6.1.1 Sofort-Scharfstell-Modus 19 6.1.2 Scharfstellverzögerungsmodus 19
6.2 Anlage unscharf stellen 20 6.3 Einrichtung für Panik-Funktion 20 6.4 Sabotagekontakt 20 6.5 Schwache Batterie 20
7 Wartung 20 8 Entsorgung und Wiederverwertung 21 9 EG-Konformitätserklärung 21 10 Garantie 21 11 Kundenbetreuung 21
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.