© Novar Electrical Devices and Systems Limited (a Honeywell Company) 2013 50083202-001 The Arnold Center, Paycocke Road, Basildon, Essex, SS14 3EA (UK) Rev. A

Page 2 of the Friedland FGGA0401WWE user manual — Table of contents
Pagina 2 · klik om te vergroten
Pagina 2

Table of contents

Page 3 of the Friedland FGGA0401WWE user manual — 3 Description
Pagina 3 · klik om te vergroten
Pagina 3

1 Intended use

The FGGA0401WWE / FGGA04* Series solar siren is suitable for use with Friedland wireless alarm systems operating at 868 MHz only. The siren uses a high-capacity, rechargeable main battery (NiMH). The solar panel on top of the housing charges the battery during daylight hours. During darkness, only a small amount of energy is required to operate the siren. The siren is supplied with an initial power-up battery (alkaline) to boost the initial power to the siren when the system is first activated until the solar panel charges the rechargeable main battery. The tamper switch will immediately trigger an alarm if any unauthorised attempt is made to interfere with and remove the siren cover. An anti-jamming detection system will generate an alarm if any attempt is made to continuously jam the radio channel used for the system.

2 Safety

2.1 Product

Keep all safety warnings and instructions for future reference. Obey the local regulations applicable to the installation of the product. Do not attempt to open the devices.

2.2 Installation

Wear safety gloves when drilling into walls. Wear safety glasses when drilling into walls. Make sure that there are no electrical wires and water pipes when drilling into walls. Position ladders onto a level and stable surface and at a safe angle.

3 Description

3.1 Package contents

PartDescriptionPartDescriptionPartDescription Solar sirenFastenersRechargeable main battery (6V, NiMH) Mounting templateInitial power-up battery (9V, alkaline) (6LR61 (PP3))Quick installation guide
Friedland FGGA0401WWE — 3 Description diagram (page 3)
Afb. 3 · 3 Description
Page 4 of the Friedland FGGA0401WWE user manual — 4 Overview
Pagina 4 · klik om te vergroten
Pagina 4

3.2 Required tools

ToolDescriptionToolDescription Ear defendersBradawl Safety glovesPhillips screwdriver (#0 / #1 / #2) Electric drillSpirit level Masonry drill bit (5 mm / 6 mm)Pencil
Friedland FGGA0401WWE — 3.2 Required tools diagram (page 4)
Afb. 4 · 3.2 Required tools

4 Overview

Friedland FGGA0401WWE — 4 Overview diagram (page 4)
Afb. 5 · 4 Overview
1. Siren 2. Tamper switch 3. Learn button 4. Learn indicator 5. DIP switches 6. Initial power-up battery (9V, alkaline) 7. Rechargeable main battery (6V, NiMH) 8. Power adaptor connection (12V) 9. Battery cover 10. Mounting plate 11. Mounting holes
1. Alarm time 2. Anti-jamming detection 3. Alarm sound 4. Beep sound 5. Siren / Control panel
Page 5 of the Friedland FGGA0401WWE user manual — 5.2 Powering up the siren
Pagina 5 · klik om te vergroten
Pagina 5

5 Installation

5.1 Configuring the siren

1. Remove the screws. 2. Remove the battery cover. 3. Set switch 5 to the required position. Without control panel ON (siren) (single zone) With separate control panel OFF (control panel) 4. Set switch 1 to limit the maximum period for which the external siren will sound. Without control panel ON (3 min) / OFF (1 min) (single zone) With separate control panel ON (10 min) / OFF (3 min) 5. Set switch 2 to enable or disable the anti-jamming detection when using the siren without control panel. ON enabled OFF disabled 6. Set switch 3 to enable or disable the siren during an alarm. ON enabled OFF disabled 7. Set switch 4 to enable or disable the beeps when the siren receives signals from the remote control or the remote keypad. ON enabled OFF disabled
Friedland FGGA0401WWE — 5 Installation diagram (page 5)
Afb. 6 · 5 Installation
Without control panel (single zone)ON (siren) With separate control panelOFF (control panel)
Without control panel (single zone)ON (3 min) / OFF (1 min) With separate control panelON (10 min) / OFF (3 min)
ONenabled OFFdisabled
ONenabled OFFdisabled
ONenabled OFFdisabled

5.2 Powering up the siren

Friedland FGGA0401WWE — 5.2 Powering up the siren diagram (page 5)
Afb. 7 · 5.2 Powering up the siren
1. Connect the initial power-up battery to the connection terminal. 2. Connect the rechargeable main battery to the connection terminal.
Page 6 of the Friedland FGGA0401WWE user manual — 5.3 Adding a new remote control or remote keypad to the siren
Pagina 6 · klik om te vergroten
Pagina 6
3. Press the tamper switch. The indicators in the front lens flash several times and then continue to flash alternately every 5 seconds to indicate that the siren is operational.
4. Remove the protective film from the solar panel.

Make sure that the solar panel receives sufficient light to maintain the battery charge.

5. a) If switch 5 is set to ON (siren), the siren will operate without control panel (single zone). b) If switch 5 is set to OFF (control panel), the siren will operate with control panel. For linking the siren to the control panel, refer to the Installation and Operation Manual for the alarm system and to the Quick Installation Guide for the siren.

5.3 Adding a new remote control or remote keypad to the siren

If you set up the siren without separate control panel (single zone) for the first time, you must link the siren to a remote keypad or a remote control before adding other devices. The ID code of the remote control or the remote keypad must be learned by the siren. The siren can learn up to 6 remote controls or remote keypads. During setup, the siren will power up in service mode, ready to learn a new remote control or remote keypad. If the siren is in operating mode, refer to the section “Service mode / Operating mode” to switch to service mode.

Remote controlRemote keypad 1Press and hold the learn button on the siren for 5 seconds to enter learn mode. The siren emits one short beep. The indicators in the front lens and the learn indicator flash slowly. 2Program the ID code: Press the button.Enter the 4-digit ID code. Press the button. The siren emits two short beeps. The indicators in the front lens and the learn indicator flash quickly. Note:If the remote control or the remote keypad has already been linked or if the maximum number of 6 remote controls or remote keypads are linked, the siren will emit one short beep and exit learn mode. The indicators in the front lens and the learn indicator will go off. 3Confirm the ID code: Press the button within 15 seconds.Enter the 4-digit ID code and press the button within 15 seconds. The siren emits three short beeps. The indicators in the front lens and the learn indicator come on for 3 seconds and go off. The siren returns to service mode. Note:If the confirmation signal is not received within 15 seconds, the siren will emit one short beep and exit learn mode. The indicators in the front lens and the learn indicator will go off.
1. Install the battery cover. 2. Install the screws.
Page 7 of the Friedland FGGA0401WWE user manual — 5.4 Mounting the siren to the wall
Pagina 7 · klik om te vergroten
Pagina 7

5.4 Mounting the siren to the wall

1. Hold the mounting template in position and mark the positions of the mounting holes. If necessary, use a spirit level. 2. Drill mounting holes (6 mm) into the wall according to the marked positions. 3. Insert a supplied wall plug into each mounting hole. 4. Install the screws (30 mm) into the top mounting holes, leaving approximately 9 mm of the screw protruding. 5. Install the mounting plate. Make sure that the holes in the mounting plate align with the bottom mounting holes. 6. Install the screws (25 mm). 7. Mount the siren to the wall. CAUTION: Make sure that the tamper switch is closed when you mount the siren to the wall. If the tamper switch does not close, the siren will not operate correctly. If necessary, remove the siren again and insert a spacer between the tamper switch plunger and the wall to make sure that the switch closes when you mount the siren to the wall. CAUTION: Before testing or operating the siren, leave it in position for at least 24 hours in order to fully charge the battery.
Page 8 of the Friedland FGGA0401WWE user manual — 5.7 Service mode / Operating mode
Pagina 8 · klik om te vergroten
Pagina 8

5.5 Adding a new security detector to the siren

In order to communicate with the siren, the ID code of the security detector must be learned by the siren. The siren can learn up to 12 security detectors (door/window contact detectors or PIR movement detectors). During setup, the siren will automatically power up in service mode, ready to learn a new security detector. If the siren is in operating mode, refer to the section “Service mode / Operating mode” to switch to service mode.

Remote controlRemote keypad 1Press and hold the button for 5 seconds.Enter the 4-digit ID code. Press and hold the button for 5 seconds. The siren emits one short beep. The indicators in the front lens and the learn indicator flash slowly. The siren remains in learn mode for 30 seconds. 2Program the ID code: Press the tamper switch on the security detector. The siren emits two short beeps. The indicators in the front lens and the learn indicator flash quickly. Note:If the confirmation signal is not received within 30 seconds, the siren will exit learn mode. The siren will remain in service mode. Note:If the security detector has already been linked or if the maximum number of 12 security detectors are linked, the siren will emit one short beep and exit learn mode. The indicators in the front lens and the learn indicator will go off. 3Confirm the ID code: Press the tamper switch on the security detector again within 15 seconds to confirm the ID code. The siren emits three short beeps. The indicators in the front lens and the learn indicator come on for 3 seconds and go off. The siren returns to service mode. Note:If the confirmation signal is not received within 15 seconds, the siren will emit one short beep and exit learn mode. The indicators in the front lens and the learn indicator will go off.

5.6 Deleting a l l devices from the siren

1. Switch the siren into service mode using the remote control or the remote keypad. 2. Remove the siren from the wall. 3. Press and hold the learn button for 10 seconds until the siren emits two long beeps and the learn indicator flashes 5 times. The ID codes of all linked devices are erased from memory. The siren remains in service mode.

5.7 Service mode / Operating mode

If you install the siren for the first time, it will automatically power up in service mode. Before testing or operating the siren, it must be switched into operating mode. If you use the siren with a control panel, refer to the Installation and Operation Manual for the alarm system. If you use the siren without a control panel, use the remote control or the remote keypad:

Remote controlRemote keypad 1Press and hold the button for 5 seconds.Enter the 4-digit ID code. Press and hold the button for 5 seconds. To switch from operating mode into service mode: If you press the button (remote control) or the button (remote keypad), the device will transmit the disarm signal and the siren will emit two normal beeps. The system is disarmed. If you press and hold the button (remote control) or the button (remote keypad) for 5 seconds, the siren will emit two short beeps followed by one long beep. The indicators in the front lens and the learn indicator will flash together with the beeps. The system will return to service mode. Switching from service mode into operating mode: If you press the button (remote control) or the button (remote keypad), the device will transmit the disarm signal. The siren will not respond to the disarm signal, as it is still in service mode. If you press and hold press the button (remote control) or the button (remote keypad) for 5 seconds, the siren will emit one long beep followed by two short beeps. The indicators in the front lens and the learn indicator will flash together with the beeps. The siren will return to operating mode in a disarmed condition.
Page 9 of the Friedland FGGA0401WWE user manual — 6.4 Device tamper
Pagina 9 · klik om te vergroten
Pagina 9

6 Operation

This section only describes the operation of the siren when operating without control panel (single zone).

6.1 Arming the system

When leaving the premises, the system must be armed. Make sure that the siren is in operating mode. Before arming the system, make sure that all doors and windows are closed and that the available PIR movement detectors are not obstructed. Make sure that animals are restricted to areas not protected by PIR movement detectors.

6.1.1 Instant-arm mode

The instant-arm mode will immediately arm the system. If the system is armed, activating any security detector will immediately trigger an alarm. When entering the premises, disarm the system before opening any door or window protected by a door/window contact detector or entering an area protected by a PIR movement detector. In the instant-arm mode, arm and disarm the system from outside the premises using the remote control or the remote keypad.

Remote controlRemote keypad 1Press the button.Enter the 4-digit ID code. Press the button. The siren emits one beep. The indicators in the front lens and the learn indicator flash once.

6.1.2 Delay-arm mode

The delay-arm mode will arm the system with a 15-second entry/exit delay. The siren will emit one beep and another beep after the 15-second delay has expired to allow time to leave the premises before the system is fully armed. When entering the premises by opening any door or window protected by a door/window contact detector or entering an area protected by a PIR movement detector, the system will be triggered and the siren will emit one long beep. However, the alarm will not sound until the 15-second delay has expired. Disarm the system using the remote control or the remote keypad during the 15-second delay. If an alarm occurs, the siren will sound continuously until the set alarm duration time expires. The alarm will stop and the system will re-arm. The alarm lockout feature will prevent the system from re-arming after repeating the process three times.

Remote controlRemote keypad 1Press the button.Enter the 4-digit ID code. Press the button or the button. After the 15-second delay has expired, the siren emits one beep. The indicators in the front lens and the learn indicator flash once to indicate the system is fully armed.
Friedland FGGA0401WWE — 6.1 Arming the system diagram (page 9)
Afb. 8 · 6.1 Arming the system

6.2 Disarming the system

Remote controlRemote keypad 1Press the button.Enter the 4-digit ID code. Press the button. The siren emits two beeps. Note:If the system is disarmed and the siren emits ten quick beeps, an alarm has been triggered while the system was armed.
Friedland FGGA0401WWE — 6.2 Disarming the system diagram (page 9)
Afb. 9 · 6.2 Disarming the system

6.3 Personal attack facility

The user can trigger an alarm at any time in the event of threat or danger by activating the personal attack facility.

Remote controlRemote keypad 1Press and hold the button for 3 seconds. Note: On earlier remote control models, slide the personal attach switch.Press and hold the button or the button for 3 seconds. The alarm is triggered. The siren will sound.
Friedland FGGA0401WWE — 6.3 Personal attack facility diagram (page 9)
Afb. 10 · 6.3 Personal attack facility

6.4 Device tamper

If the battery cover of any device (except remote controls) is removed or if the siren or the remote keypad is removed from the wall, an alarm will occur immediately even if the system is disarmed (unless the siren is in service mode). The alarm will sound until the set alarm time expires or the system is disarmed from the remote control or the remote keypad.

Page 10 of the Friedland FGGA0401WWE user manual — 10 Guarantee
Pagina 10 · klik om te vergroten
Pagina 10

6.5 Low-battery condition

If you press the button on the remote control or the remote keypad when the siren is at low-battery condition, the siren will emit three short beeps. If a low-battery indicator is activated, the device will continue to operate for up to 2 weeks. Replace the battery as soon as possible. Before replacing the battery, switch the system into service mode. After replacing the battery, switch the system back into operating mode.

7 Maintenance

The alarm system requires little maintenance. If you must power down the system completely, switch the system into service mode before removing the siren cover and disconnecting the rechargeable main battery and the initial power-up battery. Make sure that the solar panel is covered with a lightproof material to prevent the solar panel from powering the siren.

1. Clean the solar panel using a soft, damp cloth every 6 months, preferably in spring and autumn. Do not use abrasive, solvent-based or aerosol cleaners. Do not clean the inside of the siren or allow water to enter the siren to make sure that the solar panel keeps receiving all the available light.
2. Do not leave the siren for long periods with the batteries connected, unless the siren is able to receive sufficient light to maintain the battery charge. If the battery charge is not maintained, the rechargeable main battery will run unacceptably low and the siren must be recharged from a 12Vdc/1000mA power supply. Install a new initial power-up battery (9V alkaline, PP3) to make sure that the siren receives sufficient power until the solar panel can recharge the main battery.
3. Do not leave the rechargeable main battery in a discharged state for long periods. The rechargeable main battery has a typical life of 3-4 years and does not require any maintenance.

8 Disposal and recycling

The product is classified by the Waste Electrical or Electronic Equipment (WEEE) directive. The product and the batteries of the monitor should not be disposed of with other household or other commercial waste. At the end of its useful life, the packaging and the product should be disposed of via a suitable recycling centre. For information on available facilities, please contact your local authority or retailer from where the product was purchased.

9 EC declaration of conformity

Novar ED&S hereby declares that the product is in compliance with the essential requirements and other relevant provisions of the Radio and Telecommunications Terminal Equipment (R&TTE) directive (1995/5/EC).

10 Guarantee

Novar ED&S undertakes to replace or repair at its discretion goods, should they become defective within 2 year solely as a result of faulty materials and workmanship. Understandably, if the product has not been installed, operated or maintained in accordance with the instructions, if the product has not been used appropriately or if any attempt has been made to rectify, dismantle or alter the product in any way, the guarantee will be invalidated. The guarantee states Novar ED&S entire liability. The guarantee does not extend to cover consequential loss or damage or installation costs arising from the defective product. The guarantee does not in any way affect the statutory or other rights of a consumer and applies to products installed within the EU only. If an item develops a fault, the product must be returned to the point of sale with:

1. Proof of purchase. 2. Full description of the fault. 3. All relevant batteries (disconnected).
Page 11 of the Friedland FGGA0401WWE user manual — 11 Customer support
Pagina 11 · klik om te vergroten
Pagina 11

11 Customer support

For further product information and full installation manuals where applicable go to www.friedlandproducts.com

The phone calls are charged

Service Helpline UK & Northern Ireland 0844 736 9149 Monday to Friday 9:00 am - 5:00 pm

at the national rate of the

service providers.

Page 12 of the Friedland FGGA0401WWE user manual — Inhaltsverzeichnis
Pagina 12 · klik om te vergroten
Pagina 12

Inhaltsverzeichnis

1 Bestimmungsgemäßer Gebrauch 13 2 Sicherheit 13

2.1 Produkt 13 2.2 Installation 13

3 Beschreibung 13

3.1 Verpackungsinhalt 13 3.2 Erforderliche Werkzeuge 14

4 Übersicht 14 5 Installation 15

5.1 Konfiguration der Sirene 15 5.2 Hochfahren der Sirene 15 5.3 Hinzufügen einer neuen Fernbedienung oder eines neuen Funk-Bedien-/Tastenfeldes zur Sirene 16 5.4 Befestigung der Sirene an der Wand 17 5.5 Hinzufügen eines neuen Melders zur Sirene 18 5.6 Löschen aller Geräte aus der Sirene 18 5.7 Servicemodus / Betriebsmodus 18

6 Bedienung 19

6.1 Scharfstellen der Anlage 19

6.1.1 Sofort-Scharfstell-Modus 19 6.1.2 Scharfstellverzögerungsmodus 19

6.2 Anlage unscharf stellen 20 6.3 Einrichtung für Panik-Funktion 20 6.4 Sabotagekontakt 20 6.5 Schwache Batterie 20

7 Wartung 20 8 Entsorgung und Wiederverwertung 21 9 EG-Konformitätserklärung 21 10 Garantie 21 11 Kundenbetreuung 21

Vraag stellen over de Friedland FGGA0401WWE

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Friedland FGGA0401WWE