Inhoudsopgave 43 secties Instruction for the use - Installation advice English · Dear Customer, · IMPORTANT PRECAUTIONS AND RECOMMENDATIONS FOR USE OF ELECTRICAL APPLIANCES · IMPORTANT PRECAUTIONS AND RECOMMENDATIONS · … TonenVerbergen
Page 1 of the M-System MGK 602 user manual — IMPORTANT PRECAUTIONS AND RECOMMENDATIONS FOR USE OF ELECTRICAL APPLIANCES
Pagina 1 · klik om te vergroten
Pagina 1

Instruction for the use - Installation advice English

Dear Customer,

Thank you for having purchased and given your preference to our product.

The safety precautions and recommendations given below are for your own safety and that of others. They will also provide a means by which to make full use of the features offered by your appliance.

Please keep this booklet carefully. It may be useful in future, either to yourself or to others if doubts should arise relating to its operation.

This appliance must be used only for the task it has explicitly been designed for, that is for cooking foodstuffs. Any other form of usage is to be considered as inappropriate and therefore dangerous.

The manufacturer declines all responsibility in the event of damage caused by improper, incorrect or unreasonable use of the appliance.

IMPORTANT PRECAUTIONS AND RECOMMENDATIONS FOR USE OF ELECTRICAL APPLIANCES

Use of any electrical appliance implies the necessity to follow a series of fundamental rules. In particular: Never touch the appliance with wet hands or feet; do not operate the appliance barefooted; do not allow children or disabled people to use the appliance without your

supervision. The manufacturer cannot be held responsible for any damages caused by improper, incorrect or unreasonable use of the appliance.

Page 2 of the M-System MGK 602 user manual — TIPS FOR THE USER
Pagina 2 · klik om te vergroten
Pagina 2

IMPORTANT PRECAUTIONS AND RECOMMENDATIONS

After having unpacked the appliance, check to ensure that it is not damaged.

If you have any doubts, do not use it and consult your supplier or a professionally qualified technician. Packing elements (i.e. plastic bags, polystyrene foam, nails, packing straps,

etc.) should not be left around within easy reach of children, as these may cause serious injuries. The packaging material is recyclable and is marked with the recycling

symbol . Do not attempt to modify the technical characteristics of the appliance as

this may become dangerous to use. The manufacturer cannot be considered responsible for damage caused by

unreasonable, incorrect or rash use of the appliance. If you should decide not to use this appliance any longer (or decide to

substitute an older model), before disposing of it, it is recommended that it be made inoperative in an appropriate manner in accordance to health and environmental protection regulations, ensuring in particular that all potentially hazardous parts be made harmless, especially in relation to children who could play with old appliances. The appliance should be installed and all the gas/electrical connections made

by a qualified engineer in compliance with local regulations in force and following the manufacturer's instructions

TIPS FOR THE USER

During and after use of the cooktop, certain parts will become very hot. Do

not touch hot parts. Keep children away from the cooking hob when it is in use. After use, ensure that the knobs are in position G (off), and close the main

gas delivery valve or the gas cylinder valve. In case of difficulty in the gas taps operation, call Service. Before any cleaning or maintenance, switch off the electricity to the cooktop.

Risk of fire! Do not leave inflammable material on the cooktop. Make sure that the electrical cables of other appliances installed nearby

cannot come into contact with the cooktop.

Page 3 of the M-System MGK 602 user manual — FEATURES 1
Pagina 3 · klik om te vergroten
Pagina 3

FEATURES 1

M-System MGK 602 — FEATURES 1 diagram (page 3)
Afb. 1
M-System MGK 602 — FEATURES 1 diagram (page 3)
Afb. 2
M-System MGK 602 — FEATURES 1 diagram (page 3)
Afb. 3
1. Rapid burner (R1) - 3,00 kW 2. Semirapid burner (SR) - 1,75 kW 3. Semirapid burner (SR) - 1,75 kW 4. Auxiliary burner (A) - 1,00 kW 5. Triple-ring burner (TR) - 3,30 kW

CONTROL PANEL DESCRIPTION 5. Front left rapid burner 1 (R1) control knob 6. Rear left semirapid burner 2 (SR) control knob 7. Rear right semirapid burner 3 (SR) control knob 8. Front right auxiliary burner 4 (A) control knob 9. Triple-ring burner 5 (TR) control knob

M-System MGK 602 — FEATURES 1 diagram (page 3)
Afb. 4
Page 4 of the M-System MGK 602 user manual — GAS BURNERS 2
Pagina 4 · klik om te vergroten
Pagina 4

GAS BURNERS 2

To light one of the gas burners, hold

GAS BURNERS Gas flow to the burners is adjusted by turning the knobs illustrated in fig. 2.1 which control the safety valves. Turning the knob so that the indicator line points to the symbols printed on the panel achieves the following functions:

a flame (e.g. a match) close to the top part of the burner, push in and turn the relative knob in an anti-clockwise direction, pointing the knob indicator towards the large flame symbol (i.e. max. gas flow).

To reduce the gas flow to minimum,

– full circle G = closed valve

rotate the knob further anti-clockwise to point the indicator towards the small flame symbol.

– symbol = maximum

The maximum aperture position

permits rapid boiling of liquids, whereas the minimum aperture position allows slower warming of food or maintaining boiling conditions of liquids.

– symbol = minimum

Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positions, and never between the maximum aperture and closed positions.

Fig. 2.1 Fig. 2.2

aperture or flow · aperture or flow

Page 5 of the M-System MGK 602 user manual — GRILL FOR SMALL COOKWARE (fig. 2.3)
Pagina 5 · klik om te vergroten
Pagina 5

Lighting the burners WITH ELECTRIC IGNITION

CHOICE OF BURNER

On the control panel, near every knob, there is a diagram that indicates which burner is controlled by that knob. The suitable burner must be chosen according to the diameter and the capac- ity used. As an indication, the burners and the pots must be used in the following way:

To light one of the burners, press and turn the corresponding knob to the maximum flow position (large flame ) and keep the knob pressed down until the gas is lit (fig. 2.2). Turn the gas tap to the position required. Whenever special conditions of the gas supplied locally make it difficult to light the burner with the knob in the maximum flow position, repeat the operation with the knob in the minimum flow position.

DIAMETERS OF PANS WHICH MAY BE USED

ON THE HOBS

BURNERS MINIMUM MAX.

Auxiliary 6 cm 14 cm

Semirapid 16 cm 20 cm

Rapid 20 cm 24 cm

Triple-ring 24 cm 28 cm

Maximum diameter for woks: 36 cm.

do not use pans with concave or convex bases

It is important that the diameter of the pots or pans suitably match the heating potential of the burners in order not to jeopardise the efficiency of the burners, bringing about a waste of gas fuel. A small diameter pot or pan placed on a large burner does not necessarily mean that boiling conditions are reached quicker. Only used flat bottomed pans.

GRILL FOR SMALL COOKWARE (fig. 2.3)

Put it on the auxiliary burner (the small- est) grid when small cookware is being used to prevent the cookware from tip- ping over.

Page 6 of the M-System MGK 602 user manual — STAINLESS STEEL ELEMENTS
Pagina 6 · klik om te vergroten
Pagina 6

CLEANING AND MAINTENANCE 3

GENERAL ADVICE

COOKING HOB WITH GLASS LID (optional)

Before you begin cleaning you must

Do not close the glass lid when the

ensure that the hob is switched off. It is advisable to clean when the appliance is cold and especially when cleaning the enamelled parts. All enamelled surfaces have to be

gas burner or electrical plates are still hot and when the oven, installed below the cooking hob, is on or still hot.

washed with soapy water or some other non-abrasive product with a sponge and are to be dried preferably with a soft cloth. Avoid leaving alkaline or acid

Do not rest hot pans or heavy

objects on the cooker lid.

Remove any spillages from the

surface of the lid before opening.

substances (lemon juice, vinegar etc.) on the surfaces.

ENAMELLED PARTS

CONTROL KNOB

All the enamelled parts must be

The control knobs may be removed for

cleaned with a sponge and soapy water only or other non-abrasive products. Dry preferably with a chamois leather.

cleaning but care should be taken not to damage the seal.

If acid substances such as lemon juice, tomato conserve, vinegar etc. are left on the enamel for a long time they will etch it, making it opaque.

GAS TAPS

Periodic lubrication of the gas taps

must be carried out by specialist personnel only. In the event of operating faults in the

gas taps, call the Service Department.

STAINLESS STEEL ELEMENTS

Stainless steel parts must be rinsed

with water and dried with a soft and clean cloth or with a chamois leather. For persistent dirt, use specific non-

abrasive products available commer- cially or a little hot vinegar. Note: regular use could cause dis-

colouring around the burners, because of the high flame tempera- ture.

Page 7 of the M-System MGK 602 user manual — CLEANING AND MAINTENANCE 3
Pagina 7 · klik om te vergroten
Pagina 7
M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 7)
Afb. 5
M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 7)
Afb. 6

flame spreaders must be well dried and correctly replaced.

It is very important to check that the

burner flame spreader and the cap have been correctly positioned. Failure to do so can cause serious problems.

keep the electrode clean so that the sparks always strike.

tric ignition do not use it when the burners are not in place.

It is very important to check that the burner flame spreader F and the cap C have been correctly positioned (see figs. 3.1 and 3.5 ). Failure to do so can cause serious problems. Check that the electrode “S” (fig. 3.1) is always clean to ensure trouble-free sparking. Both the probe and ignition plug must be very carefully cleaned.

M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 7)
Afb. 7
M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 7)
Afb. 8
Page 8 of the M-System MGK 602 user manual — CLEANING AND MAINTENANCE 3
Pagina 8 · klik om te vergroten
Pagina 8
M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 8)
Afb. 9

The triple ring burner must be correctly positioned (see fig. 3.2); the burner rib must be fitted in their housing as shown by the arrow.

Then position the cap A and the ring B (fig. 3.3 - 3.4). The burner correctly positioned must not rotate (fig. 3.3).

M-System MGK 602 — CLEANING AND MAINTENANCE 3 diagram (page 8)
Afb. 10
Page 9 of the M-System MGK 602 user manual — IMPORTANT
Pagina 9 · klik om te vergroten
Pagina 9

Installation advice

INSTALLATION 4

IMPORTANT

The appliance should be installed, regulated and adapted to function with other

types of gas by a QUALIFIED INSTALLATION TECHNICIAN.

The appliance must be installed in compliance with regulations in force in your

country and in observation of the manufacturer's instructions.

Always unplug the appliance before carrying out any maintenance operations or

repairs.

The appliance must be housed in heat-resistant units.

These tops are designed to be embedded into kitchen fixtures measuring 600

mm in depth.

The walls of the units must not be higher than work top and must be

capable of resisting temperatures of 75 °C above room temperature.

Do not instal the appliance near inflammable materials (eg. curtains).

Page 10 of the M-System MGK 602 user manual — Installation advice
Pagina 10 · klik om te vergroten
Pagina 10

In order to install the cooker top into the kitchen fixture, a hole with the dimen- sions shown in fig. 4.1 has to be made, bearing in mind the following:

M-System MGK 602 — Installation advice diagram (page 10)
Afb. 11 · Installation advice

side of the cooker top and the upper surface of any other appliance or internal shelf there must be a clearance of at least 30 mm;

the cooker top must be kept no less

than 100 mm away from any side wall (fig. 4.1).

the hob must be installed at least 35

there must be a distance of at least

650 mm between the hob and any wall cupboard or extractor hood positioned immediately above (see fig. 4.2)

a separator between the base of the hob and the drawer unit.

M-System MGK 602 — Installation advice diagram (page 10)
Afb. 12 · Installation advice
Page 11 of the M-System MGK 602 user manual — CHOOSING SUITABLE SURROUNDINGS
Pagina 11 · klik om te vergroten
Pagina 11

CHOOSING SUITABLE SURROUNDINGS

M-System MGK 602 — CHOOSING SUITABLE SURROUNDINGS diagram (page 11)
Afb. 13

In the room chosen to accommodate the gas appliance, there must be an ade- quate natural draft to allow combustion of the gas. The flow of air must come directly from one or more openings made in the out- side walls with a free area of at least 200 cm2.

Extractor hoods connected directly to the outside must be provided, to allow the products of combustion of the gas appliance to be discharged (fig. 4.3). If this is not possible, an electric fan may be used, attached to the external wall or the window; the fan should have a capacity to circulate air at an hourly rate of 3-5 times the total volume of the kitchen (fig. 4.4). The fan can only be installed if the room has suitable vents to allow air to enter, as described under the heading “Choosing suitable surroundings”.

The vents must be positioned close to the floor, preferably on the opposite side to the combustion discharge outlet and must be designed in such a way that they cannot be obstructed either from the inside or the outside. When it is not possible to provide the necessary vents, the draft may be sup- plied from an adjacent room, ventilated in the required manner, provided it is not a bedroom or an area at risk. In this event, the door of the kitchen must be opened to allow the draft to enter the room.

M-System MGK 602 — CHOOSING SUITABLE SURROUNDINGS diagram (page 11)
Afb. 14
Page 12 of the M-System MGK 602 user manual — B
Pagina 12 · klik om te vergroten
Pagina 12

À

À

À

À

INSTALLATION IN KITCHEN CABINET WITH DOOR (fig. 4.5)

À

À

À

À

À

À

À

À

À

The fixture has to be made according to specific requirements in order to prevent the gas burners from going out, even when the flame is turned down to minimum, due to pressure changes while opening or closing the cupboard doors. It is recommended that a 30 mm clearance be left between the cooker top and the fixture surface (fig. 4.5).

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

À

FASTENING THE INSTALLATION BRACKETS (fig. 4.6)

Each cooker top is provided with an installation kit including brackets and screws for fastening the top to fixture panels from 2 to 4 cm thick.

Turn the cooker top upside down and fasten the brackets “A” to the appropriate socket holes, without tightening the screws “B” for the moment. Make sure that the brackets are fastened as shown in figure 4.6.

40 mm max.

20 mm min.

B

A

FASTENING THE COOKER TOP (fig. 4.6)

– Spread the sealing material “C” out

along the fixture hole, making sure that the junctions overlap at the corners.

– Insert the cooker top into the hole and

position it correctly.

– Adjust the position of the brackets “A”

and tighten screws “B” to block the cooker top firmly in position.

– With a sharp cutter or trimmer knife

trim the excess sealing material around the edge of the cooker top.

Show 102 more labels / short text on this page
· @ · € · @ · € · · @ · € · · @ · € · @ · € · · · @ · € · · @ · € · · @ · € · · @ · € · · · @ · € · @ · € · @ · € · · · · @ · € · · · @ · € · · @ · € · · @ · € · · @ · € · · · @ · € · @ · € · @ · € · · · · · 30 mm · Clearance · @ · € · · · @ · € · · @ · € · · @ · € · · @ · € · · · @ · € · @ · € · @ · € · · Door · Space for connections · @ · € · · · · @ · € · @ · € ·
Page 13 of the M-System MGK 602 user manual — F
Pagina 13 · klik om te vergroten
Pagina 13

GAS SECTION 5

NL

Cat: II 2L 3B/P

F C A

ES

Cat: II 2H3+

GAS CONNECTION

The cooktop is set up and calibrated to work with the gas indicated on the rating plate affixed to the appliance and on this instruction booklet.

NL

The gas supply system must conform to the local regulations in force.

Fig. 5.1a

To conned the cooktop to the gas mains or cylinder use a flexible stainless steel hose with continuous wall conforming to local regulations. Use gasket F for the cylindrical elbow connection.

F C A

The flexible metal tubes must be at most 2 m long.

1/2” G - cylindrical

F

ES

Fig. 5.1b

The cooktop connection is made up as follows: 1 nut “A” union elbow “C”:

- cylindrical - for Spain - conical - for Holland gaskets “F”

1/2” G conical

Page 14 of the M-System MGK 602 user manual — IMPORTANT
Pagina 14 · klik om te vergroten
Pagina 14

IMPORTANT

Never attempt to turn the fitting C

without having first slackened off the relative lock nut (fig. 5.2).

The seal F (fig. 5.1) is the element

that guarantees the seal in the pipe- ramp connector. It is recommended that it be replaced whenever it shows even the slightest deformation or imper- fection.

After connecting to the mains,

check that the couplings are cor- rectly sealed, using soapy solution, but never a naked flame.

Page 15 of the M-System MGK 602 user manual — J
Pagina 15 · klik om te vergroten
Pagina 15

GAS MAINTENANCE

ADAPTING THE APPLIANCE TO FUNCTION WITH DIFFERENT TYPES OF GAS

OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS

If a different gas from that one indicated on the label is used, you need to adapt the cooktop to this new situation. If the injectors are not supplied they can be obtained from the “Service Centre”. Select the injectors to be replaced according to the table on next page. The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

Remove the pan-supports, the burner

covers and the knobs;

Using a wrench substitute the injec-

tors “J” (Fig. 5.3 - 5.4) with those ones suitable for the type of gas for which it is to be used.

The burners are conceived in such a way so as not to require the adjust- ment of the primary air.

J

J

Page 16 of the M-System MGK 602 user manual — A IR VENT NECESSARY FOR GAS COMBUSTION = (2 m 3 /hxkW)
Pagina 16 · klik om te vergroten
Pagina 16

TABLE FOR THE CHOICE OF THE INJECTORS - Cat: II 2L 3B/P NL

G30/G31 G 25 BURNERS 28-30/30 mbar 25 mbar

[kW] By-pass [1/100 mm]

Ø injector [1/100 mm] Ø injector [1/100 mm]

Auxiliary (A) 1,00 0,30 27 50 72

Semirapid (SR) 1,75 0,45 34 65 94

Rapid (R) 3,00 0,75 44 85 121

Triple-ring (TR) 3,30 1,50 65 91 130

TABLE FOR THE CHOICE OF THE INJECTORS - Cat: II 2H 3+ ES

G30/G31 G 20 BURNERS 28-30/37 mbar 20 mbar

[kW] By-pass [1/100 mm]

Ø injector [1/100 mm]

Ø injector [1/100 mm] By-pass [1/100 mm]

Auxiliary (A) 1,00 0,30 27 50 Adjustable 72

Semirapid (SR) 1,75 0,45 34 65 Adjustable 97

Rapid (R) 3,00 0,75 44 85 Adjustable 115

Triple-ring (TR) 3,30 1,50 65 91 Adjustable 124

A IR VENT NECESSARY FOR GAS COMBUSTION = (2 m 3 /hxkW)

BURNERS Air vent necessary [m3/hr]

Show 16 more labels / short text on this page
Nominal · Reduced · power · power · [kW] · By-pass [1/100 mm] · Adjustable · Nominal · Reduced · power · power · [kW] · Auxiliary (A) 2,00 · Semirapid (SR) 3,50 · Rapid (R) 6,00 · Triple-ring (TR) 6,60
Page 17 of the M-System MGK 602 user manual — A
Pagina 17 · klik om te vergroten
Pagina 17

REGULATING THE BURNER MINIMUM SETTING

LUBRICATING THE GAS TAPS

When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maxi- mum to minimum flame. To regulate the flame follow the instruc- tions below: – Light the burner – Set the cock valve to minimum

If one of the gas taps becomes hard to turn, dismantle it, thoroughly clean with petrol and apply special high-tempera- ture grease.

On gas valves provided with adjust- ment screw in the centre of the shaft (fig. 5.5): – Using a screwdriver with max. diame-

ter 3 mm, turn the screw inside the tap until the correct setting is obtained.

On gas valves provided with adjust- ment screw on the valve body (fig. 5.6): – Turn the screw “A” to the correct set-

ting with a screwdriver.

For G 30/G 31 gas, tighten the adjust- ment screw completely.

A

Fig. 5.5 Fig. 5.6

Page 18 of the M-System MGK 602 user manual — DETAILS
Pagina 18 · klik om te vergroten
Pagina 18

ELECTRICAL SECTION 6

After having installed the appliance,

the power switch or power plug must always be in a accessible position.

N.B. For connections to the mains power supply, never use adapters, reductions or multiple power points as these may overheat and catch fire.

In the event that installation should require modifications to the mains sup- ply wiring system or if the power plug is not suitable for the type of power point available, it is recommended that a qual- ified technician be called to carry out substitution. The technician will also have to verify that the cross-section of the electric cables on the power point match the appliance’s power rating.

DETAILS

Connection to the electric power sup-

ply must be carried out by a qualified technician and following the appropri- ate safety regulations; Before carrying out the connection to

the power supply, the voltage rating of the appliance (stamped on the appli- ance identification plate) must be checked for correspondence to the available mains supply voltage, and the mains electric wiring should be capable of handling the hob’s power rating (also indicated on the identifica- tion plate); The power point must be connected to

Before carrying out any work on the electrical section of the appli- ance, it must be disconnected from the mains.

a suitable earth wiring, in conformity to current safety regulations. The hob is supplied without a power

supply plug and therefore if you are not connecting directly to the mains, a standardized plug suitable for the load must be fitted. It is possible to connect the appliance

If the power supply cable is dam- aged it must be substituted by a suitable cable available in the after sales service.

directly to the mains supply by means of a heavy duty switch with 3 mm mini- mum distance between the contacts. The power supply cord must not touch

Connection to a good earth wiring system is absolutely essential. The manufacturer accepts no responsibility for any inconve- nience caused by failure to comply with this rule.

against any hot surfaces and must be placed so that its temperature does not exceed 75°C at any point along its length.

Page 19 of the M-System MGK 602 user manual — L1 N(L 2 ) PE
Pagina 19 · klik om te vergroten
Pagina 19

REPLACING THE POWER SUPPLY CABLE

FEEDER SPECIAL CABLE SECTION Type “HO5V2V2-F” resistance to temperatures of 90°C

Use the same type of power supply cable. This cable must be connected to the ter- minal block following the diagram in fig. 6.1.

230 VAC 50 Hz 3 x 0,75 mm2

L1 N(L 2 ) PE

Descriptions and illustrations in this booklet are given as simply indicative. The manufacturer reserves the right, considering the characteristics of the models described here, at any time and without notice, to make eventual necessary modifications for their construction or for commercial needs.

Page 20 of the M-System MGK 602 user manual — REPLACING THE POWER SUPPLY CABLE
Pagina 20 · klik om te vergroten
Pagina 20
Page 20 of the M-System MGK 602 user manual — REPLACING THE POWER SUPPLY CABLE
Page 21 of the M-System MGK 602 user manual — REPLACING THE POWER SUPPLY CABLE
Pagina 21 · klik om te vergroten
Pagina 21

1102135 ß1

Vraag stellen over de M-System MGK 602

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de M-System MGK 602

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

M-System MGK 602 handleiding-pdf

80 pagina's·3.9 MB·Fornuis·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…