NL
Master logo
Officiële handleiding

master DH 752

106 pagina's·1.9 MB·Luchtbevochtiger/-ontvochtiger·PDF·ENJA
master DH 752
Inhoudsopgave 24 secties Fig. 4 Fig. 3 · Fig. 6 Fig. 5 · Fig. 8 Fig. 7 · Fig. 10 Fig. 9 · … TonenVerbergen
Page 1 of the master DH 752 user manual
Pagina 1 · klik om te vergroten
Pagina 1
master DH 752 diagram (page 1)
Afb. 1

MCS Russia LLC ul. Transportnaya 22 vl 2, 142802, Stupino, Moscow region, Russia [email protected]

MCS China LTD Unit A1, No. 1515, Jinshao Rd.,

Page 2 of the master DH 752 user manual
Pagina 2 · klik om te vergroten
Pagina 2
master DH 752 diagram (page 2)
Afb. 2

ТЕХНИЧЕСКИ ДАНИ - TECHNICKÉ ÚDAJE - TECHNISCHE DATEN - TEKNISK DATA -

TEHNILISED ANDMED - ESPECIFICACIONES TÉCNICAS - TEKNISET TIEDOT - DONNÉES TECHNIQUES - TECHNICAL DATA - TEHNIČKI PODACI - MŐSZAKI ADATOK - DATI TECNICI - TECHNINIAI DUOMENYS - TEHNISKIE DATI - TECHNISCHE GEGEVENS

- TEKNISKE DATA - DANE TECHNICZNE - DADOS TÉCNICOS - INFORMAłII TEHNICE -

ТЕХНИЧЕСКИЕ ДАННЫЕ - TEKNISKA DATA - TEHNIČNI PODATKI -

MODELDH 752 220V-240V~, 50Hz 230 V900W/ 4.2A (R T 30 ºC ) RH 80%46,7 l/24h 350 m3/h HFCR407c, 0,37 kg (GWP 1600) 5 ÷ 35 oC 20 ÷ 90% HO 25,7 l ≤52 dB(A) H L W495 x 375 x 825 mm 30 kg
Page 3 of the master DH 752 user manual — Fig. 10 Fig. 9
Pagina 3 · klik om te vergroten
Pagina 3
master DH 752 — Fig. 4 Fig. 3 diagram (page 3)
Afb. 3 · Fig. 4 Fig. 3
master DH 752 — Fig. 4 Fig. 3 diagram (page 3)
Afb. 4 · Fig. 4 Fig. 3

Fig. 4 Fig. 3

master DH 752 — Fig. 4 Fig. 3 diagram (page 3)
Afb. 5 · Fig. 4 Fig. 3
master DH 752 — Fig. 4 Fig. 3 diagram (page 3)
Afb. 6 · Fig. 4 Fig. 3

Fig. 6 Fig. 5

master DH 752 — Fig. 6 Fig. 5 diagram (page 3)
Afb. 7 · Fig. 6 Fig. 5
master DH 752 — Fig. 6 Fig. 5 diagram (page 3)
Afb. 8 · Fig. 6 Fig. 5

Fig. 8 Fig. 7

master DH 752 — Fig. 8 Fig. 7 diagram (page 3)
Afb. 9 · Fig. 8 Fig. 7
master DH 752 — Fig. 8 Fig. 7 diagram (page 3)
Afb. 10 · Fig. 8 Fig. 7

Fig. 10 Fig. 9

Page 4 of the master DH 752 user manual — Fig. 18 Fig. 17
Pagina 4 · klik om te vergroten
Pagina 4
master DH 752 — Fig. 12 Fig. 11 diagram (page 4)
Afb. 11 · Fig. 12 Fig. 11
master DH 752 — Fig. 12 Fig. 11 diagram (page 4)
Afb. 12 · Fig. 12 Fig. 11

Fig. 12 Fig. 11

master DH 752 — Fig. 12 Fig. 11 diagram (page 4)
Afb. 13 · Fig. 12 Fig. 11
master DH 752 — Fig. 12 Fig. 11 diagram (page 4)
Afb. 14 · Fig. 12 Fig. 11

Fig. 14 Fig. 13

master DH 752 — Fig. 14 Fig. 13 diagram (page 4)
Afb. 15 · Fig. 14 Fig. 13
master DH 752 — Fig. 14 Fig. 13 diagram (page 4)
Afb. 16 · Fig. 14 Fig. 13

Fig. 16 Fig. 15

master DH 752 — Fig. 16 Fig. 15 diagram (page 4)
Afb. 17 · Fig. 16 Fig. 15
master DH 752 — Fig. 16 Fig. 15 diagram (page 4)
Afb. 18 · Fig. 16 Fig. 15

Fig. 18 Fig. 17

Page 5 of the master DH 752 user manual — START ON:
Pagina 5 · klik om te vergroten
Pagina 5
en CONTENTS 1... BEFORE USE 2...CONSTRUCTION 3...OPERATION 4...MAINTENANCE AND SAFETY 5...NOTICES ABOUT UNIT OPERATION 6...ELIMINATION DE DÉTÉRIORATIONS
master DH 752 — ►► ► 1. BEFORE USE diagram (page 5)
Afb. 19

►► ► 1. BEFORE USE

4. Water tank 5. Water tank panel 6. Filter grill 7. Hour counter

► ►please do not cut off the power by pulling the wire

► ►please do not plug or unplug to startup or shut off the unit

► ►Control panel FIG. 2 1. humidity display 2. operate indicator 3. defrost indicator 4. memory indicator 5. tank full indicator 6. memory 7. humidity up 8. humidity down 9. on/off button

► ►please be careful when moving the unit, do not mangle the wire

► ►please do not put fingers or sticks into the grid

► ►please prohibit child to climb, stand or sit on the unit

► ►please unplug the unit before cleaning or maintenance

►► ► 3. OPERATION INSTRUCTION OF KEYS:

► ►please make sure the unit is grounded

► ►please do not use unit in airproof conditions

► ►please follow the instructions thoroughly

► ►ON/OFF: Press ON/OFF, the unit runs in a circulation “ON-OFF-ON”.

PRODUCT INTRODUCTION Dehumidifiers can reduce air humidity in room and thus make people live comfortably and goods stored properly. Due to their neat appear- ance, compact configuration, high quality and easy operation, our dehumidifiers are widely used in research institutions, industry, transpor- tation, medical centers, measuring institutions, stores, underground constructions, computer rooms, archives, warehouses, bathrooms, etc. Keeping apparatus, meters, computers, com- munication equipments, drugs and files away from moisture, eroding, and mildew.

► ►Humidity up and down: Press “humidity up and down” for once, the set humidity will in- crease or decrease by 1%. Press the key for 1.5 seconds and the set value will increase or decrease by 1%. Press continuously with the speed 5 points per second.

► ►Memory Key: Press the memory key and the memory indicator will light on to start the func- tion of memory when the power cuts off. Press the memory key again; the memory indicator dies to shut off the function of memory when the power is cut off.

START ON:

►► ► 2. CONSTRUCTION

► ►Plug on the unit gives off “di”.

► ►Press “ON/OFF”, the running indicator lights on, and the humidity display window lights on to display the previously set humidity. The initial humidity setting is 60% and 3 seconds later the humidity display window lights on to display cur-

► ►Dehumidifier FIG. 1 1. Handle 2. Control panel 3. Wheel

Page 6 of the master DH 752 user manual — ►► ► 4. MAINTENANCE AND SAFETY
Pagina 6 · klik om te vergroten
Pagina 6

rent humidity.

Otherwise, it might result in fire, radiation, or an electric shock.

► ►Press humidity up or down key to adjust the humidity needed. If the set humidity is 3% less than current humidity, the unit runs; if the set hu- midity is 3% more than current humidity, the unit stops running.

► ►FIG. 4 Do not put the unit nearby stove or heater. Oth- erwise parts of unit might melt down or even catch fire.

► ►When set humidity is less than 30%, the unit dehumidifies continuously, and the humidity dis- play window reads “CO”.

► ►FIG. 5 Do not use the unit in the direct sunshine, wind or rain. (only for indoor usage)

SHUT OFF:

► ►Press “ON/OFF” when the unit is running, the unit stops running and all indicators die.

► ►FIG. 6 In case of any other problems (for example smell of scorch ), please shut off the unit and unplug it. Otherwise, it might result in fire, electric shock or other malfunctions.

NOTICES:

► ►When the set humidity is higher than current humidity, the unit will not run.

► ►When the tank is full, the tank full indicator lights on, meanwhile, the compressor and the fan motor shut off automatically, and the buzzer gives off “DD” sound. Unless the tank is emp- tied, the buzzer gives the “DD” sound every 5 minutes. Only after emptying the tank the unit will start running again.

► ►FIG. 7 Do not use the unit in places easily affected by chemicals. Strong chemicals might damage the unit and cause the leakage.

► ►FIG. 8 Please unplug the unit when not used for a long time.

► ►When dehumidifying, the fan motor and com- pressor must be running at least for 3 minutes, once the compressor starts on. It is strongly for- bidden to restart the compressor again within 3 minutes after the shut off.

► ►FIG. 9 When cleaning, shut off and unplug the unit. Otherwise, it might result in an electric shock.

► ►When operating in low temperature, the unit judges the system temperature automatically to defrost. When defrosting, the defrosting indica- tor lights on, the compressor runs but fan motor shuts off automatically.

► ►FIG. 10 When draining continuously, put the drainer for smooth drainage. If the ambient temperature is as low as freezing, do not drain continuously.

► ►When you press the memory key, the control- ler will record current humidity even if the power is off. The unit will run under previous mode af- ter power supplied again.

► ►FIG. 11 Do not repair or disconnect the unit yourself. Otherwise it might result in fire or an electric shock.

► ►The humidity display window shows humidity from 30% to 90%.

► ►Keep the unit unplugged if not used for a long time.

► ►FIG. 12 Put the unit stably. If the unit turns over, the wa- ter will flow out from the tank and damage the objects nearby. Moreover, because of the dam- age, it might result in fire or an electric shock

CONTINUOUS DRAINAGE:

► ►Take out the tank, open drainage gate at the bottom of tank, connect pipeline, fix the tank back, and pull the pipeline out from the bottom of the machine.

► ►FIG. 13 Make the filter more endurable. When off for a long time, seal the filter in a plastic bag.

►► ► 4. MAINTENANCE AND SAFETY

► ►FIG. 3 Do not use any relay, prolonged wire or adaptor.

Page 7 of the master DH 752 user manual — STRANGE NOISE
Pagina 7 · klik om te vergroten
Pagina 7

► ►FIG. 14 Do not use the unit near water. The unit might be damaged when soaked in water, so as to re- sult in fire or electric shock.

►► ► 6. TROUBLE-SHOOTING

UNIT DOES NOT WORK

► ►Analysis 1.Power cut 2.Switch off 3.Unplugged 4.Fuse melted 5.Tank full

► ►FIG. 15 Use the standard electric source of 220-240V/~50Hz. Otherwise it might result in fire or electric shock.

► ►FIG. 16 Do not damage the wire. Do not put anything heavy on the wire or heat or pull the wire. Oth- erwise it might result in fire of an electric shock.

► ►Solution 1.Power on 2.Switch on 3.Plug on 4.Exchange fuse 5.Empty the tank and replace it

► ►FIG. 17 Clean the dirt on the plug and fix it tightly. If the plug is not fixed tightly, it might cause an electric shock.

DEHUMIDIFIES IN INADEQUATELY

► ►Analysis 1.Filter choked by dirt 2.Some barrier in air inlet or outlet 3.Door or windows open 4.Refrigerant leakage

► ►FIG. 18 Do not regard the plug as a switch. Otherwise it might result in fire or an electric shock.

►► ► 5. NOTICES ABOUT UNIT OPERATION

► ►Solution 1.Clean the filter 2.Remove the barrier 3.Close the door and windows and seclude from the sunshine 4.Contact the manufacturer or seller

► ►When moving the unit, do not tilt over 45°to avoid any damaging of the compressor.

► ►The unit should be operated between 5°~32°.

► ►When dehumidifying, because of the heat re- sulted from the running compressor, the indoor temperature will rise by 1°~3°. Such a reaction should be considered as normal.

WATER LEAKAGE

► ►Analysis 1.The unit is inclined 2.Drainer choked

► ►When indoor temperature is below 10°, and the ambient absolute humidity is quite low, it is unnecessary to use the machine.

► ►Air inlet and air outlet should be at least 10cm away from the wall.

► ►Solution 1.Adjust the unit to be stable 2.Pull out the panel and remove the barrier

► ►Try to keep the room closed to enhance the dehumidification effect.

► ►Too much dirt on the filter affects dehumidi- fication, may even result in malfunctioning of it, thus it should be cleaned at least once a month. If there is a great amount of powder in the air, the filter must be cleaned once a week, or even every day. Pull the front panel out and clean the filter. If necessary, you may slightly knock all over the filter, use a vacuum cleaner to remove bigger pieces of dirt or even wash the filter in warm clean water (≤40% with some neutral de- tergents) and then dry it.

STRANGE NOISE

► ►Analysis 1. Until instable 2. Filter choked

► ►Solution 1.Place the unit stably 2.Clean the filter

► ►When above malfunctions occur and they could not be removed, please contact the sup-

Page 8 of the master DH 752 user manual — MALFUNCTION DISPLAY E2
Pagina 8 · klik om te vergroten
Pagina 8

plier or seller, do not disassemble the machine yourself.

► ►When the unit starts or stops running, it makes certain noises of refrigerating circulation, which should not be considered as a malfunction.

► ►Hot air coming from the air outlet is normal.

INSTRUCTION ON MALFUNCTION CODES: The unit analyzes malfunction automatically and displays the code on the humidity window.

MALFUNCTION DISPLAY E1

► ►Sensor of humidity

MALFUNCTION DISPLAY E2

► ►Sensor of refrigeration pipeline

Vraag stellen over de master DH 752

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de master DH 752

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

master DH 752 handleiding-pdf

106 pagina's·1.9 MB·Luchtbevochtiger/-ontvochtiger·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…