REFERENCE MANUAL SENC 50 Acu-Rite Companies Inc..
.
Page Introduction / Supplied items ............................................... 2 Key Points / Tolerances ......................................................... 3 Linear Encoder Dimensions .................................................. 4 Spar Dimensions .
The SENC 50 Precision Glass Scale Linear Encoder provides the accuracy and reliability of an Acu-Rite Companies Inc. measuring system in a very small cross-section with digital output (analog output available). Features and options include: • Resolutions of 0.
Use this information to plan your Linear Encoder installation. • Understand your mounting requirements. • Follow kit instructions when using an Acu-Rite Companies Inc. bracket kit. • Mount encoders close to ways to insure system accuracy. • Mount with lip seals down and away from the work area.
Acu-Rite Companies Inc. 4 Linear Encoder Dimensions SENC 50 Measuring length + 4.65 [118] Measuring length + 4.09 [103.9] .280 [7.11] Typ. End cap Scale assembly Scale case Mounting hole .335 [8.51] .140 [3.55] .463 [11.76] .175 [4.57] Typ. 1.85 [47.00] 2.
680803-13 13 17.650 3.825 3 5.000 680803-16 16 20.650 2.825 4 5.000 680803-18 18 22.650 1.325 3 10.000 680803-15 15 19.650 2.325 4 5.000 680803-14 14 18.650 1.825 4 5.000 SENC 50 Sp ar Dimensions 5 Acu-Rite Companies Inc. Backup spar Linear Encoder L A X No.
Mounting Requirement s SENC 50 Mounting options can be adapted to machine mounting surfaces using spacers, standoffs, and leveling screws. • Measuring length and mechanical configuration of your equipment determines your options. • Length related mounting options shown.
A variety of mounting conditions can be accommodated. • Mechanical configuration of the equipment determines brackets and adapters required to install the linear encoder. • Three typical conditions are shown for reference. • Flush or offset mounting surfaces using a spar.
Encoder Installation Procedure SENC 50 These steps apply to all mounting conditions. Although this may not pictorially represent your application, your installation procedure should follow these steps. • Acu-Rite Companies Inc. Acu-Rite Companies Inc.
• Slide shipping brackets from reading head and twist to remove from the scale case. • Save the shipping brackets with the Reference Manual. • Drill / tap the first end mounting hole / Attach the scale case. • Align to within .005” TIR. and drill / tap second end hole.
• Check function of the linear encoder. These steps will confirm proper operation of your installation. Counting tests check channel A and B output function and Reference Mark tests check Reference Mark operation. • Configure the readout for proper counting resolution.
11 Acu-Rite Companies Inc. SENC 50 Electrical Shielding Connect a ground wire from the terminal on the back of the readout to the machine or earth ground.
Acu-Rite Companies Inc. 12 T rouble Shooting SENC 50 If you experience difficulties with your installation, there are methods to analyze the difficulty.
13 Acu-Rite Companies Inc. SENC 50 Mechanical Specifications Mechanical Specifications Digital Analog Resolution 0.5µm 1µm 5µm Grating pitch 20µm Scale medium Light transmission reflective off of chrome coated glass Accuracy (@ 20° C) / 1000mm ± 3µm, ± 5µm Max.
Digital Differential Digital Differential Digital Differential Digital Differential Digital Differential Analog Differential Analog Differential Analog Differential Analog Differential Analog Differen.
15 Acu-Rite Companies Inc. SENC 50 Electrical Specifications Parameter Analog Output Signals Incremental signals Signal levels Reference Mark signals Signal level Power Supply Square-wave voltage signals.
Acu-Rite Companies Inc. 16 Acu-Rite Companies Inc. W arranty SENC 50 ACU-RITE Companies, Inc. is proud to offer the 3-Year Hassle-Free Warranty for all readout systems, and precision glass scales.
.
Acu-Rite Companies Inc. Acu-Rite Companies Inc. Acu-Rite Companies Inc. Acu-Rite Companies Inc. Acu-Rite Companies Inc. IS AN IS AN IS AN IS AN IS AN ISO 9001 ISO 9001 ISO 9001 ISO 9001 ISO 9001 CERTI.
Een belangrijk punt na aankoop van elk apparaat Acu-Rite 516353-21 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Acu-Rite 516353-21 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Acu-Rite 516353-21 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Acu-Rite 516353-21 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Acu-Rite 516353-21 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Acu-Rite 516353-21 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Acu-Rite 516353-21 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Acu-Rite 516353-21 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.