VISTUS AD | ENGLISH

Scope of delivery VISTUS AD-4030: 1x Outdoor station with three bell buttons 3x Indoor station 1x Power supply ST-1000 1x Assembly materials

INTRODUCTION

Thank you for choosing the VISTUS Video intercom system. You have purchased a high quality system.

The assembly should be carried out by a specialist.

Scope of delivery VISTUS AD-4001x Indoor station 1x Assembly materials

Care Information Wipe the plastic casing with a slightly damp cloth. Do not use aggressive cleaning materials.

PREPARING FOR INSTALLATION

Legend

The following lines are required:

Outdoor station A.2= Loudspeaker A.3= Nameplates /Bell button A.4= Microphone A.5= Casing screws A.6= Brightness sensor

Single-family house: 3 lines from the outdoor unit to the indoor unit and 2 lines from the outdoor unit to the door opener.

Two- and three-family house: Here 3 lines are required per bell button from the outdoor unit into each residential unit as well as 2 lines from the outdoor unit to the door opener.

Indoor station B. 3= Mute button B. 4= Key button B. 5= Microphone B. 6= Talk button B. 7= Internal button B.11= Melody B.12= Volume + B.13= Volume - B.14= Casing back B.15= Snap fastener C.1 = PCB screws

Up to four indoor units can be connected in parallel per residential unit. The connection can be laid as 1. Serial connections (from indoor station to indoor station) or as 2. Radial connections (parallel) from one central point (distribution box).

The wiring plan in the affix is base on a radial wiring system as this is preferable.

The lines should be laid in such a way that each is fed out of the wall directly behind the corresponding outdoor/indoor unit.

Scope of delivery VISTUS AD-4010: 1x Outdoor station with one bell button 1x Indoor station 1x Power supply ST-1000 1x Assembly materials

ASSEMBLY OF THE OUTDOOR STATION

The door intercom point is designed for surface mounting.

Scope of delivery VISTUS AD-4020: 1x Outdoor station with two bell buttons 2x Indoor station 1x Power supply ST-1000 1x Assembly materials

Preparation When removing the front cover ensure that the nameplate does not fall out and become damaged. Also take care of the cable in the loudspeaker, which is attached in the front part of the casing.

Page 2 of the ME AD 4020 user manual — ASSEMBLY OF THE INDOOR STATION
Pagina 2 · klik om te vergroten
Pagina 2

ENGLISH | VISTUS-AD

1. Remove the two screws in order to be able to open the casing on the outdoor station. The casing is also fitted with notches and projections that connect the upper and lower parts of the casing. Thus a certain amount of force is necessary in order to separate the casing parts. 2. Position the drilling template for the outdoor station in a level location at the intended assembly location (a spirit level is helpful for this) and attach it with sticky tape. 3. Use the drilling template to drill the attachment holes with a 6mm drill and insert a dowel into each hole. 4. Now remove the drilling template. 5. Feed the lines through the large hole in the outdoor station and secure them with 4 screws. 6. Connect the line in accordance with the wiring plan.

1. The casing on the indoor station is kept together with notches and projections. To separate the lower section from the front section, press a small slotted screwdriver against the snap fastener (B.15) on the bottom side. 2. Use the lower section of the casing as an aid to mark the drill holes. Make sure that you hold the lower section in a horizontal position for this step. NOTE: The lower casing section on the indoor station can also be

attached to a hollow wall box. The corresponding attachment holes are located around the line feed hole. If this does not provide enough hold then drill more holes and use them to also screw the indoor station in place. 3. Drill the attachment holes with a 6 mm drill and insert one dowel in each hole. 4. Feed the lines through the feed hole in the lower casing part designed for this purpose and screw this down. 5. Attach the lines in accordance with the wiring plan and replace the front casing section onto the lower casing section. Make sure that it clicks correctly into place.

Adjusting the nameplate The nameplate comprises two transparent plastic parts that are connected with 2 or 4 small screws.

7. Remove all screws from the nameplate and take the plate apart. The foil for the name can be found between the plastic parts. 8. Write on the foil with a smudge proof felt tip pen or print a nameplate* using a PC and printer. 9. Lay the complete nameplate (foil) between the two plastic parts and screw them back together.

CONNECTION

An exact description of where the individual connections and terminals are located can be found in the figures. The recommended wiring can be seen in the corresponding wiring plan in the affix.

* Size of the nameplate: VISTUS AD-4010: 71 mm x 50 mm VISTUS AD-4020: 71 mm x 25 mm VISTUS AD-4030: 71 mm x 15mm

Connect the lines to the audio, +15V and GND on the outdoor station. These terminals are also present on the indoor stations and need to be connected to one another 1:1.

10. Replace the nameplate in the front cover before re-attaching the front cover to the outdoor station. You can attach a strip of sticky tape over the nameplate and the casing to ensure that the nameplate does not fall out during assembly.

installation in order to prevent damage to the front cover!

11. Screw the front cover on using both casing screws. Please ensure that the screws are not tilted as this can damage the thread in the lower section of the casing.

Connecting the door opener The door opener is connected directly to the outdoor station with two lines (Figure A ‚Door opener‘). No additional power supply is necessary in order to control the door opener. The door opener must be designed for 12 volt DC voltage and may not require more than 0.9A of power. In the event that the door opener needs to be correctly polarised then both connection terminals must be marked ‘lock +’ and ‘lock –‘.

ASSEMBLY OF THE INDOOR STATION

The installation height of the Indoor stations can be selected freely according to your circumstances.

Page 3 of the ME AD 4020 user manual — POSSIBLE SETTINGS ON THE INDOOR STATION
Pagina 3 · klik om te vergroten
Pagina 3

VISTUS-AD | ENGLISH

Alternatively, the VTX-Bell can also be attached directly to the plug, however the button for selecting the bell tone on the VTX-Bell will no longer be easily accessible.

POSSIBLE SETTINGS ON THE OUTDOOR STATION

The outdoor station has the following possibilities of adjusting the system to your personal circumstances:

Connecting the power supply The power supply can be connected to either the indoor or the outdoor station. Separate spring clips are present for this purpose.

Volume on the outdoor station The potentiometer (Figure A ‚Volume / Lautstärke‘) is used to set the speaking volume on the outdoor station. For full volume turn the potentiometer carefully in a clockwise connection until it stops and turn it back a little. Turning the potentiometer in an anti-clockwise direction reduces the volume.

It is also possible to connect the power supply directly to the signal line e.g. from the fuse box to the outdoor and indoor units. The power supply unit then needs to be connection with the ground (GND) and +15V. Open power supply unit can supply up to 8 units with power.

Connecting a floor button Any floor button that is present (normal closing contact) is connected in parallel to the terminals ‘audio’ and ‘GND’. On the 2- and 3-family versions please note that the correct audio line is used (Audio1 and GND for family 1, Audio2 and GND for family 2 and Audio3 and GND for family 3).

ID code If several outdoor stations are used in parallel (e.g. on the gate and on the house), the DIP switch is used to set the ID code (Figure A, ‚ID-CODE‘).

ID1 = Switch 1 ‘on’, Switch 2 ‘on’ ID2 = Switch 1 ‘on’, Switch 2 ‘off’ ID3 = Switch 1 ‘off’, Switch 2 ‘on’

Door opener time The DIP switch (Figure A, ‚Door opener time‘) is used to set how long the door opener should be activated for. The possible settings are 1 second or 5 seconds. 5 seconds is the factory setting and works for most standard door openers.

Connecting the wireless expansion model VTX-BELL The VTX-BELL can be used to send the bell signal wirelessly to the receiver in the BELL series (currently BELL 200 RX, BELL 210 USB and BELL 220 RX). The wireless module will be attached to the 3-pole plug inside the indoor station (Figures C). For more information please see the VTX-BELL instructions.

Switch ‘off’ corresponds to an opening time of 1 second. Switch ‘on’ corresponds to an opening time of 5 seconds.

The plug for the VTX-Bell transmitter is located on the front of the main PCB. To install the transmitter, unscrew the PCB from the housing. Remo- ve the eight screws which connect the PCB to the housing (Fig. C No. 1). Then remove the PCB and turn it over. A 3-pin plug is located at the top of the PCB. It is labelled with Signal, GND and VCC. Attach the transmitter connecting cable to the plug so that yellow is connected to Signal, black to GND and red to VCC. Turn the PCB over again and route the cable to the back of the PCB as shown in Fig. 2 B. Make sure that the cable is not squeezed at any point. Screw the PCB back on using the eight screws. Now connect the transmitter to the cable and fix it in place with a piece of adhesive tape.

POSSIBLE SETTINGS ON THE INDOOR STATION

The following settings are possible on the indoor station to adjust the system to your personal circumstances:

Ring tone volume The potentiometer (Figure C ‘Bell Volume‘’) is used to set the ring/ volume on the indoor station. For full volume turn the potentiometer carefully in a clockwise connection until it stops. Turning the potentio- meter in an anti-clockwise direction reduces the volume.

Page 4 of the ME AD 4020 user manual — SAFETY INSTRUCTION
Pagina 4 · klik om te vergroten
Pagina 4

ENGLISH | VISTUS-AD

Deactivate ring tone/melody (e.g. during the night) The ring tone/melody can be deactivated, e.g. in order to prevent disturbance during the night. Either press the mute button on the indoor unit once briefly. The LED below the mute button lights up red as a reminder that the melody is deactivated. To activate the melody again press the mute button again briefly. When the red LED goes out the melody has been re-activated. The optical signal (surround light on the talk and door opener button) remains active, even then the ring tone/melody is deactivated and still rings. The red LED flashes if the bell is rung while the mute is activated.

OPERATION (as internal house intercom)

All indoor units that are connected to the same bell button can also be used as an internal intercom. 1. Press the internal button (B. 7) on the indoor station from which you wish to reach another indoor station. All the connected indoor station will ring. No image will be shown. 2. To accept the conversation on one of the other connected indoor stations you need to briefly press the talk button there (B. 6). 3. The talk button needs to be pressed briefly on one of the two indoor stations in order to end the conversation.

Technical data:

Outdoor station Operating voltage: 15V DC Standby power:

Speaking volume The two side buttons (B. 12 and 13) can be used to set the speaking volume in several steps. Button 12 is used to increase the volume and button 13 to reduce it.

Melody selection The next melody is played every time you press the button (B/C.11). The last melody to be played is automatically stored.

Indoor station Operating voltage15V DC Standby power: <0.5W

NOTES

OPERATION (as door intercom system)

The functionality of the unit can be affected by the influence of strong static, electrical or high frequency fields (discharging, mobile phones, radios, microwaves).

1. Press the bell button. 2. The stored ring tone will play on the corresponding indoor station(s) 3. Accept the conversation on the indoor unit by pressing briefly on the talk button ( ). 4. If a door opener is connection then you can activate it by briefly pressing the door opener button ( ). The bell button will light green for the duration of the door opener as confirmation. 5. Press the talk button ( ) briefly in order to switch the system back to standby operation.

Cleaning and maintenance Always disconnect mains powered units from the mains supply before cleaning (disconnect the plug). The unit housing can be cleaned using a soapy soft cloth. Do not use any abrasive materials or chemicals. Remove dust build-up from ventilation slits using a brush and clean up using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly against the unit.

SAFETY INSTRUCTION

In the event of damage to the housing, connectors, power cables or isolation shielding, switch off the device immediately and disconnect

Page 5 of the ME AD 4020 user manual — WARRANTY
Pagina 5 · klik om te vergroten
Pagina 5

VISTUS-AD | ENGLISH

from the mains power. ELECTRIC SHOCK – DANGER OF LOSS OF LIFE. (Unplug the mains connector from the socket!). Damage should be repaired immediately by a specialist!

GB These operating instruction are published by m-e GmbH modern-electronics, An den Kolonaten 37, 26160 Bad Zwischenahn/Germany

Do not take the product apart! There is a danger of lethal electric shock!

The operating instructions reflect the current technical specifications at time of print. We reserve the right to change the technical or physical specifications.

Never carry out repairs yourself!

For reasons of safety and licensing (CE), unauthorised conversion and / or modification of the product is prohibited.

The design of the product complies with protection class 1. Only a standard mains socket (230V~/50Hz) of the public mains supply may be used to power the device. Devices powered by mains voltage must be kept away from children. Please therefore be particularly careful in the presence of children.

Do not leave packaging material lying about since plastic foils and pockets and polystyrene parts etc. could be lethal toys for children. The interior unit is suitable only for dry interior rooms (not bathrooms and other moist places). Do not allow the devices to get moist or wet. There is a danger of lethal electric shock!

In industrial institutions, the accident prevention regulations of the Asso- ciation of Commercial Professional Associations for electrical installations and equipment must be observed. Please consult a specialist should you have doubts regarding the method of operation, the safety, or the connections of the device.

Handle the product with care – it is sensitive to bumps, knocks or falls even from low heights.

WARRANTY

2 years warranty from date of purchasing, on base of correct using.

The producer is not responsible for consequential damages which are effected directly or indirectly from this item.

The warranty will be null and void in case of damages arising from viola- tions of these operating instructions. We are not liable for consequential damages!

We accept no liability for material damages or injuries arising from inappropriate use or violation of the safety instructions. In such cases all warranty claims are null and void!

Page 6 of the ME AD 4020 user manual — FR
Pagina 6 · klik om te vergroten
Pagina 6
ME AD 4020 — FR diagram (page 6)
Afb. 1

FR

Abb. B DIAGRAM B ILLUSTRATION B AFBEELDING B B

  • INNENSTATION
  • INDOOR STATION
  • BOÎTIER INTÉRIEUR
  • BINNENSTATION
Page 7 of the ME AD 4020 user manual — FR
Pagina 7 · klik om te vergroten
Pagina 7

VISTUS-AD | FRANÇAIS

ME AD 4020 — VISTUS-AD | FRANÇAIS diagram (page 7)
Afb. 2
  • INNENSTATION
  • INDOOR STATION
  • BOÎTIER INTÉRIEUR
  • BINNENSTATION

Abb. C DIAGRAM C ILLUSTRATION C AFBEELDING C C

FR

Vraag stellen over de ME AD 4020

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de ME AD 4020

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

ME AD 4020 handleiding-pdf

36 pagina's·2.3 MB·Intercom·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…