Control Panel D9412GV4/D7412GV4 v2.00 en UL Installation Instructions.
.
Table of contents 1 Introduction 4 1.1 About documentation 4 1.2 Determine Bosch Security Systems, Inc. Product Manufacturing Dates 4 2 Installation 5 2.1 Installation Preparation 5 2.2 Enclosure Options 5 2.3 Mounting Enclosure 5 2.4 Installing the Control Panel 6 2.
Introduction About documentation Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Installation Installation Preparation This section contains a general installation procedure and refers to other sections of the document for detailed instructions.
i Notice! Electromagnetic interference (EMI) can cause problems on long wire runs. Figure 2.1: Enclosure Mounting Callout - Description 1 - Point chart label 2 - Mounting skirt hooks (2) 3 - Module mo.
Connecting Earth Ground Terminal 10 To help prevent damage from electrostatic charges or other transient electrical surges, connect the system to earth ground at Terminal 10 before making other connections. Recommended earth ground references are a grounding rod or a cold water pipe.
Figure 2.2: Ground Fault Detect (S4) Callout - Description 1 - S4 Locked (Closed). Control panels detects ground faults. 2 - S4 Unlocked (Open). Control panel does not detect ground faults.
Figure 2.3: Reset Pin Callout - Description 1 - Reset pin locked (closed) 2 - Reset pin normal (open) Control Panel Installation | en 9 Bosch Security Systens, Inc.
Diagrams Faceplates Figure 3.1: Faceplates Callout - Description Callout - Description 1 - Charging status LED (yellow) 8 - Ring 2 - Low battery LED (red) 9 - Operation monitor LED (green) 3 - Color-c.
Power Supply Side Wiring Diagrams D9412GV4/D7412GV4 Power Supply Side System Wiring Diagram (Power and Phone) Figure 3.2: Side System Wiring Diagram Callout - Description Callout - Description 1 - If required by local AHJ, connect D113 Battery Lead Supervision Module.
i Notice! For UL Certified accounts, additional power can be obtained using only a UL Listed auxiliary 12.0 VDC regulated, power-limited power supply. i Notice! All terminals accept for Outputs A, B, and C (Terminals 6, 7 and 8) are supervised. D9412GV4/D7412GV4 Input Points and Peripheral Devices System Wiring Diagram Figure 3.
i Notice! For D129, use zero retard except for waterflow devices. All external connections except Terminal 5 (battery positive) are power limited. Control Panel Diagrams | en 13 Bosch Security Systens, Inc. UL Installation Instructions 2012.12 | 02 | F.
SDI Devices Wiring Diagrams D9412GV4 SDI and Zonex Devices System Wiring Diagram Figure 3.4: D9412GV4 System Wiring Diagram, SDI and Zonex Devices Callout ᅳ Description Callout ᅳ Description 1 ᅳ.
i Notice! Terminals 24 through 36 are power limited, supervised. Fire and Intrusion devices must be on separate circuits. Refer to ICP-SDI-9114 Installation Instructions (P/N: F01U030068) D7412GV4 SDI and Zonex Devices System Wiring Diagram Figure 3.
i Notice! Terminals 24 through 36 are power limited, supervised. Fire and Intrusion devices must be on separate circuits. Refer to ICP-SDI-9114 Installation In- structions (P/N: F01U030068).
Module D9412GV4 D7412GV4 4 BB810/B820 SDI2 Inovonics Interface Modules 1 1 B920 Two-line Alphanumeric Keypad 5 16 16 B930 ATM Style Alphanumeric Keypad (SDI2) 5 16 16 B520 Auxiliary Power Supply Module 8 8 1 For the D7412GV4, only 5 inputs are available on the Octo-input at address 7.
SDI2 Bus Wiring Recommendations Use the following SDI2 bus wiring recommendations for SDI2 installation. The SDI2 bus is used by the GV4 Control Panel and corresponding modules to communicate with one another. Modules can be connected via home run, daisy chain, or single level T-tapped anywhere on the SDI2 bus.
Cable capacitance Overall cable length Cable capacitance Overall cable length Cable capacitance Overall cable length Cable capacitance Overall cable length pF/ft ft pF/ft ft pF/ft ft pFf/ft ft < 17.
Power Supply and Power Outputs Power Supply - Primary Primary (AC) Power Circuit The primary source is a 16.5 VAC, 40 VA, internally-fused transformer (Bosch Security Systems, Inc. Model D1640). The control panel draws 225 mA when idle and 300 mA when in an alarm state.
D8004 Transformer Enclosure Required for Fire Systems Use the D8004 Transformer Enclosure for the D1640 Transformer in fire and combined fire and burglary applications. i Notice! Check with the Authority Having Jurisdiction (AHJ) about mounting transformers on specific circuits.
! Warning! High current arcs are possible. The positive (red) battery lead and Terminal 5 can create high current arcs if shorted to other terminals or the enclosure. Use caution when working with the positive lead and Terminal 5. Always disconnect the positive (red) lead from the battery before removing it from Terminal 5.
Figure 4.2: Non-PowerLimited Wiring Callout ᅳ Description 1 ᅳ Conduit required for use with external batteries. 2 ᅳ Battery wires 3 ᅳ 0.25 in (6.
– Terminal 8: Output C (Switched Auxiliary Power) PTC CB5 protects Terminal 24: Zonex Power. PTC CB1 protects Terminal 32: SDI Power +. PTC CB3 protects Terminal 36: SDI2 Power +. Required by UL: – All devices powered from a power output are to be supervised.
F01U265459) contains complete instructions for programming outputs. Refer to Terminals 6 and 7, page 25 , Fire System Power Formula, page 25 , and Terminal 8, page 26 for descriptions of the functions of each terminal. Refer to the Bell Parameters section of the program to set the Fire Bell, Alarm Bell, and Gas Bell output responses for outputs.
Terminal 8 Terminal 8 provides continuous positive (+) 12.0 VDC Nominal power. Output C interrupts the power at Terminal 8 when activated. Use Terminal 8 to power smoke detectors or other devices that are reset by interrupting power. One self-resetting circuit breaker protects Terminals 6, 7, and 8 against shorts.
Specifications Voltage Input (Power Supply) 1 Primary: Terminals 1 and 2 16.5 VAC 40 VA class 2 plug-in transformer (D1640) Secondary: Terminals 4 and 5 Sealed lead-acid rechargeable battery (12.0 VDC, 7 Ah or 12.0 VDC, 17.2 or 18 Ah). The control panel supports up to two 12.
SDI Bus B-: 9 VDC 15000 (4572 m) maximum SDI2 Bus SDI2 Bus A+; 12 VDC nominal 7500 ft (2286 m) maximum 3 SDI2 Bus B-: 12 VDC nominal (7500 ft) (2286 m) maximum 3 Telephone Connections Connection: RJ31X or RJ38X jack can connect the control panels. Two telco lines: Bosch Security Systems, Inc.
B520 Specifications Voltage Input (Power Supply) Primary: 18 VAC terminal 18.0 VAC, 50 VA class 2 plug-in transformer -TR1850 (18.0 VAC, 50 VA class 2 plug-in transformer – TR1850-CA for Canada) Sec.
Recharge Cycle AC ON – Load shed relay resets, battery charging begins, Battery Trouble and AC Restoral Reports sent. 12.6 VDC – Battery Restoral Report sent, Low Battery LED off.
Terminal No Terminal Description Requirements 16 POINT 4 Terminal accommodates 14 to 22 AWG, use appropriate wire size based on loop resistance less than 100 Ω. 17 POINT 5 Terminal accommodates 14 to 22 AWG, use appropriate wire size based on loop resistance less than 100 Ω.
Terminal No Terminal Description Requirements 36 SDI2 POWER Terminal accommodates 14 to 22 AWG, use appropriate wire size based on peripheral device current.
Model Title UL 864 UL 985 Intrusion cUL Intrusion D1218 12 V, 17.2 Ah Rechargeable Battery D1255/D1255B Keypads (General Purpose) X X X D1255W Text Keypad (white) X X X D1260/ D1260B 2 Keypads X X X D1640 16.
Model Title UL 864 UL 985 Intrusion cUL Intrusion 3 RFRP-A RADION repeater X X 3 RFPR-12-A RADION PIR X 3 RFPR-C12_A RADION PIR C X 3 RFUN RADION universal transmitter X 1 Where the fire alarm transmitter is sharing on-premise communications equipment, the shared equipment must be UL Listed (ITE or fire potective signaling).
.
Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com © Bosch Security Systems, Inc., 2012.
Een belangrijk punt na aankoop van elk apparaat Bosch Appliances D9412GV4 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bosch Appliances D9412GV4 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bosch Appliances D9412GV4 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bosch Appliances D9412GV4 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bosch Appliances D9412GV4 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bosch Appliances D9412GV4 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bosch Appliances D9412GV4 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bosch Appliances D9412GV4 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.