Proper Use This flash unit is intended solely for taking pictures of motifs in the photographic field. It may be opera- ted only with the accessories described in this instruction manual or the accessories approved by Metz. The flash unit may not be used for any purpose other than that described above.

Take a look at the diagrams at the end of the manu- al.

Introduction Thank you for choosing a Metz product. We are delighted to welcome you as a customer. You will of course be impatient to start using the flash unit. However, it is worthwhile reading the operating instructions and learning how to use the unit cor- rectly. This flash unit is suited for: • Digital Pentax cameras with P-TTL - flash mete- ring. This flash unit is not suited for other brands of cameras.

1 Safety instructions The flash unit may in no event be activated in the vicinity of inflammable gases or liquids (petroleum, solvents etc.). RISK OF EXPLOSIONS! Do not flash directly into eyes from a close distance! Direct flashing into the eyes of per- sons or animals can cause damage to the reti- na and severe disruption of the vision – up to and including permanent blindness! Never use a flash unit to photograph car, bus, bicycle, motorbike or train drivers while they are driving. Blinding the driver can lead to an accident! If the housing has been damaged in such a way that internal components are exposed, the flash unit may no longer be used. Remove the batteries! Do not touch any internal compo- nents. HIGH VOLTAGE! After repeated flashing, do not touch the diffu- ser. Risk of burns! Do not dismantle the flash unit! HIGH VOLTAGE! Repairs should only be performed by authori- sed service personnel.

Declaration

Page 2 of the Metz mecablitz M400 - Pentax user manual
Pagina 2 · klik om te vergroten
Pagina 2
  • The flash unit is exclusively designed and authorised for use in photographic applications.
  • Only use the power sources designated and autho-rised in the operating manual!
  • Do not open the batteries or short them!
  • In no event the batteries be exposed to high temperatures like direct sunlight, fire or similar!
  • Never throw flat/dead batteries onto a fire!
  • Do not use any toxic batteries or rechargeable batteries!
  • Remove the used batteries immediately from the device! Chemicals can escape from used batteries (so-called “leaks”) resulting in damage to the device!
  • Batteries may not be recharged!
  • Do not expose the flash unit to water drops and splashes!
  • Protect your flash unit from heat and high air humidity! Do not keep it in the glove compartment of your car!
  • Rapid changes in temperature may lead to condensation. If this occurs, allow time for the unit to become acclimatized!
  • When you activate the flash, there should be no opaque material directly in front of or on the reflector cover (flash window). The intense energy emissions can otherwise lead to scorching or spotting of the material and/or the reflector cover.
  • After a series of flashes with full power and short intervals, a pause of at least 3 minutes must be observed after each series of 20 flashes!
  • When taking a series of flash shots at full light output and with rapid recycling times, and with zoom positions of 35 mm and less, the diffuser heats up, due to the high level of thermal energy.
  • This flash unit may be used in combination with a camera-integrated flash only if the flash can be folded out completely.
Page 3 of the Metz mecablitz M400 - Pentax user manual — +
Pagina 3 · klik om te vergroten
Pagina 3
  • 2 Dedicated flash functions Dedicated flash functions are flash functions that have been specially adapted to a given camera system. Depending on the type of camera, different flash functions are supported.
  • Flash-ready indication in camera viewfinder/camera display
  • Correct exposure indicator in camera viewfinder /camera display
  • Automatic flash sync speed control.
  • Flash bracketing „FB“
  • Automatic flash / triggering control
  • Contrast control
  • P-TTL flash mode
  • Automatic P-TTL-fill-in flash control
  • 1st or 2nd curtain synchronisation (2. CURTAIN)
  • High-speed synchronisation (high speed flash operation) P-TTL-HSS
  • Automatic motor zoom control
  • AF measuring beam control
  • Automatic flash range indication
  • Programmed auto flash mode
  • Preflash function for reducing the red-eye effect
  • Wireless remote flash operation as master
  • Wireless remote flash operation as controller
  • Wireless remote flash operation as slave flash unit
  • Servo mode
  • Wake-up function for the flash unit

+

Using lenses not equipped with a CPU (i.e., lenses without auto focus mode), results in certain functional limitations!

It is impossible to describe all camera types and their individual dedicated flash functions within the scope of these instructions. Therefore, please refer to the flash mode descripti- on in your camera’s operating instructions to find out which functions are supported and which ones have to be set manually on the camera.

Page 4 of the Metz mecablitz M400 - Pentax user manual — 3 Preparing the flash unit for use
Pagina 4 · klik om te vergroten
Pagina 4

+

+

If your flash unit is not going to be used for an extended period of time, remove the batteries.

Please only use the power sources given above. If other power sources are used, there is a risk of damaging the flash unit.

  • 3.1 Power supply Suitable batteries/rechargeable batteries The flash unit can be operated with any of the following batteries:
  • 4 nickel-metal-hydride batteries 1.2V, type IEC HR6 (size AA). They have a significantly higher capacity than NiCad batteries and are less harmful to the environment, since they have no cadmium.
  • 4 alkaline-manganese dry cell batteries 1.5V, type IEC LR6 (size AA). Maintenance-free power source for moderate power requirements.
  • 4 lithium batteries 1.5V, type IEC FR6 (size AA). Maintenance-free high-capacity power source with a low self-discharge rate.

3 Preparing the flash unit for use

+

Flat or dead batteries should not be disposed of with ordinary household waste. Help protect the environment, and dispose of flat/dead batteries at the appropriate collection points.

When inserting batteries, ensure that the polarity is correct and matches the symbols in the battery compartment. Inserting the batteries in the wrong direction can destroy the flash unit! Always replace all batteries simultaneously, and make sure that batteries are the same brand and have the same capacity.

  • Replacing batteries The disposable/rechargeable batteries are empty or used up if the recycling time (time from the triggering of a full-power flash, e.g. in the M mode, to the moment the flash-ready indicator lights up again) exceeds 60 seconds. In addition, the battery warning appears on the display.
  • Switch off the flash unit. To do this, press the button until all displays turn off.
  • Remove flash unit from the camera, push battery cover downwards and open.
  • Insert batteries lengthwise according to the battery symbol indicated.
  • Close battery cover and push upwards.
Page 5 of the Metz mecablitz M400 - Pentax user manual — 3.2 Mounting the flash unit Mounting the flash unit on the camera
Pagina 5 · klik om te vergroten
Pagina 5

+

+

  • Turn off the camera and flash before mounting or dismounting.
  • Turn the knurled nut towards the flash unit housing as far as it will go.
  • Remove the flash unit from the camera’s accessory shoe.
  • Turn off the camera and flash before mounting or removing.
  • Turn the knurled nut towards the flash unit housing as far as it will go. The locking pin in the adapter shoe is now fully retracted into the case.
  • Slide the flash unit foot completely into the camera accessory shoe.
  • Turn the knurled nut towards the camera housing as far as it will go, clamping the flash unit in place. If the camera does not have a locking hole, the spring-loaded locking pin retracts into the adapter case so as not to damage the surface. Removing the flash unit from the camera

3.2 Mounting the flash unit Mounting the flash unit on the camera

AUTO P-TTL P-TTL HSS

MODE

+

3.4 The selection menu (MODE) • Press the button and the drop-down menu will appear. The buttons can be used to select the opera- ting mode. AUTO, chap. 7.1 P-TTL, chap. 7.2 P-TTL HSS, chap. 7.5 M, chap. 7.4 LED, chap. 7.6 MASTER, chap. 10.1 CONTROL, chap. 10.2 SLAVE, chap. 10.3 SERVO, chap. 10.4 F1 / F2, chap. 7.7

If the flash unit will not be used for an extended period of time, we recommend that you switch off the flash unit with the button and remove the power source (disposable/rechargeable batteries).

The button flashes red in stand-by mode. To switch off the flash unit, press the button until all displays turn off.

3.3 Switching the flash unit on and off • Switch on the flash unit with the button. The start screen appears. The flash unit always switches on afterwards with the mode of operation that was used last.

Page 6 of the Metz mecablitz M400 - Pentax user manual — + +
Pagina 6 · klik om te vergroten
Pagina 6

A-ZOOM

INFO

AF OFF

OFF

3.6 INFO The current settings of the flash unit can be display- ed during operation. • Press and hold the ° button. The will appear. What is displayed will depend on the operating mode and the selected options.

4. only in SERVO mode. The displayed flash parameters are dependent on the selected flash mode.

3.5 The OPTIONS Menu • Press the button and the menu will appear. With the buttons, the options; can be chosen independently of the operating mode. ZOOM (reflector setting), chap. 9.1 STANDBY (autom., unit switch-off), chap. 3.7 AF BEAM (AF auxiliary light), chap. 11.3 DISPLAY (Brightness), chap. 14.1 UNIT (metres / Feet), chap. 14.2 RESET, chap. 15.3 CHANNEL2)3 (Channel), chap. 10.1.3, 10.2.2, 10.3.2 SYNC4), chap. 10.4.2

INFO

2. only in MASTER/CONTROLLER mode 3) only in SLAVE mode

+ +

The flash unit should always be turned off using the main switch if it is not going to be used for an extended period! The flash unit switches off completely about 1 hour after its last use.

In SLAVE/SERVO mode, the automatic cut-off is not activated.

  • 3.7 Auto OFF for the flash unit The flash unit is factory-set to automatically switch to standby mode (Auto OFF) 3 minutes after
  • being switched on,
  • a flash is fired,
  • the shutter release is actuated,
  • the camera’s exposure metering system is switched off. . . . . . switched to stand-by mode, (Auto-OFF) to save energy and to protect the power source from unintentional discharging. The active automatic unit switch-off is shown in the INFO display. The flash ready indicator and the indicators on the OLED display disappear. The button flashes red in stand-by mode. The most recently used operating setting is retained after automatic shutdown and is immediately restored when the camera is switched on. The flash unit can be turned on again by pressing the ° button, or by tapping on the shutter release (wake-up function).
Page 7 of the Metz mecablitz M400 - Pentax user manual — HSS P-TTL P-TTL
Pagina 7 · klik om te vergroten
Pagina 7

STANDBY

ZOOM STANDBY AF-BEAM

OFF ON

  • Press the ° button and confirm the selected setting. The button flashes red in stand-by mode.
  • Use the button to select the menu option .
  • Press the ° button and open the menu.
  • Setting the automatic unit switch-off
  • Switch on the flash unit with the button. The start screen appears. The flash unit always switches on afterwards with the mode of operation that was used last.
  • Press the button and the menu will appear.
  • Use the buttons to select the menu option .

STANDBY

ON

OK

4.2 Correct exposure indication With proper exposure, the OK symbol will light up on the display for about 3 seconds if the recording in flash modes and ; see 7.2) and automatic mode were properly exposed! If there is no exposure control indication after the shot, then the photograph was underexposed. In that case, you must: - set the next smaller f-stop (e.g. use f-stop 8 inste- ad of 11), or - reduce the distance to the subject or to the reflec- tion surface (e.g. for indirect flashes), or - set a higher ISO value on the camera. Note the maximum flash range indicated on the dis- play of the flash unit (see 5.2).

4.1 Flash readiness indication When the flash capacitor on the flash unit is char- ged, the button lights up in green, thus indi- cating that the flash unit is ready. This means that flash light can be used for the next shot. Flash readiness is also transmitted to the camera and indicated accordingly in the camera's viewfinder. If a photograph is taken before flash readiness appears, then the flash unit will not be triggered. If the camera has already switched to flash sync speed, the shot may have the wrong exposure (see 13.1).

4 OLED displays on the flash unit

HSS P-TTL P-TTL

AUTO

Page 8 of the Metz mecablitz M400 - Pentax user manual — HSS P-TTL P-TTL
Pagina 8 · klik om te vergroten
Pagina 8

EV

7,9 m

P-TTL

5.2 Range display When using cameras and a lens with CPU, the range is indicated in the display. For this a data exchange must have occurred bet- ween the camera and flash unit, for example by tap- ping the shutter release. The range can be displayed either in metres (m) or feet (ft) - see 14.2).

5.1 Display of the flash mode The current flash mode is shown in the display. Depending on the type of camera, different displays are available for the selected TTL flash mode (e.g. and ) and the manual flash mode (see 7.4).

5 Information in Display The cameras transmit the settings for ISO, lens focal length (mm) and aperture to the flash unit. It calculates the maximum flash range from the set- tings and their guide number. Flash mode and range are shown on the flash unit’s display. If the flash unit is operated without receiving data from the camera, then the values set on the flash unit will be shown.

HSS P-TTL P-TTL

M

+

- if the flash unit is working in REMOTE MASTER, REMOTE SLAVE, SERVO or AUTO mode. 5.2.1 Range display in P-TTL and P-TTL HSS flash modes In thP-TTL flash modes and ; see 7.2;7.5) the value for the the maximum range of the flash unit is displayed. The value indicated relates to subjects with a reflec- tion factor of 25%, which applies to most photogra- phic situations. Strong deviations from this reflection factor, as in the case of highly reflective or poorly reflective sub- jects, may affect the flash range of the flash unit. The subject should be in the range of 40% to 70% of the maximum range. This will give the electronics sufficient scope for compensation. To avoid overexposure, at least 10% of the maxi- mum range should be maintained as the minimum distance from the subject of the photo. Adjustment to the photographic situation at hand can be achieved by, for example, changing the aperture of the setting on the lens.

- when the reflector head is tilted out of its normal position (upwards or sideways).

he flash range is not displayed when . . .

HSS P-TTL P-TTL

Page 9 of the Metz mecablitz M400 - Pentax user manual — EV
Pagina 9 · klik om te vergroten
Pagina 9

5.2.2 Range display in manual flash mode In manual flash mode , the distance that must be maintained from the subject for correct flash expo- sure is indicated. Adjustment to the photographic situation at hand can be achieved by, for example, changing the aperture setting on the lens or selec- ting a manual partial light output level (see 7.4). 5.2.3 Exceeding the display range Flash ranges of up to 99 m or 99 ft can be shown in the display. This display range can be exceeded in the case of high ISO values and large aperture openings. An arrow after the distance value indicates that the display range has been exceeded.

  • 6 Displays in the camera viewfinder Examples for the camera viewfinder display: Flash symbol flashes Command to switch on or use the flash unit. Flash symbol is illuminated: The flash unit is ready for use (by some cameras). The viewfinder in some cameras features an incorrect exposure warning function: the viewfinderís display for aperture value, shutter speed (or both) flashes by over or underexposure. Incorrect exposure guidelines:
  • overexposure: do not use the flash!
  • underexposure: switch the flash on or use a tripod and a longer exposure time. Reasons for incorrect exposure can lay in the various exposure and automatic programmes. For information applicable to the displays in the viewfinder of your camera model, refer to the camera’s operating instructions.
Page 10 of the Metz mecablitz M400 - Pentax user manual — P-TTL
Pagina 10 · klik om te vergroten
Pagina 10

7.2 P-TTL-flash mode Before shooting, the flash unit fire one measuring preflashe. The camera evaluates the reflected preflash light. Depending on the result of the evalua-tion, the sub- sequent flash exposure is adapted by the camera to suit the given shot situation (see camera operating instructions for further details).

7.1 AUTO Flash Mode With the AUTO flash mode, the flash unit can be used easily for flash photography. It is not necessa- ry to select particular settings on the flash unit. The AUTO flash mode is a simplified flash mode for digital cameras without settings choices and/or the camera mode “P mode" and the fully automatic mode.

  • 7 Flash modes Depending on the camera model, the following flash modes are available:
  • Automatic flash mode ( ), chap. 7.1
  • P-TTL flash mode ( ), chap. 7.2
  • Manual flash mode ( ), chap. 7.3
  • Automatic high-speed synchronisation (HSS), chap. 7.5
  • LED mode (video light), chap. 7.6
  • mode settings , chap . 10.1
  • mode, chap . 10.2.
  • flash mode, chap. 10.3
  • mode, chap . 10.4.

MASTER

SERVO

SLAVE

CONTR.

P-TTL

M

AUTO

P-TTL

EV

7,9 m

AUTO P-TTL P-TTL HSS

MODE

  • Set a suitable mode of operation on the camera, e.g. P, Tv, Av, M etc.
  • Tap the shutter release to transfer data between the flash unit and the camera.
  • Press the ° button and confirm the selected operating mode.
  • Setting the mode of operation
  • Switch on the flash unit with the button. The start screen appears. Thereafter, the flash unit always switches on with the mode of operation that was used last).
  • Press the button and the drop-down menu will appear.
  • Use the buttons to select the operating mode.

P-TTL

Page 11 of the Metz mecablitz M400 - Pentax user manual — M
Pagina 11 · klik om te vergroten
Pagina 11

+

7.4 Manual flash mode In the manual flash mode M, the flash unit emits the full uncontrolled amount of light if no partial light output has been selected. The specific photo- graphic situation can be taken into account by adju- sting the aperture setting or by selecting a suitable manual partial light setting. The setting area ranges from P 1/1 to P1/256 in mode. The display shows the distance at which the subject is correctly lit (see 5.2).

Ensure that the contre-jour light source does not shine directly into the lens, as this will interfere with the camera’s TTL metering system! There is no setting or display for automatic P TTL fill- in flash in the flash unit.

7.3 Automatic P-TTL Fill-in flash mode The automatic P-TTL fill-in flash mode is activated by most cameras when the automatic programme P is selected and by Vari or subject programmes during daylight (see camera operating manual). Fill-in flash mode overcomes troublesome shadows and produces a more balanced exposure between subject and background with contre-jour shots. The camera’s computer-controlled metering system sets the most suitable combination of shutter speed, aperture and flash output.

M

P 1/1 7.9 m

M

P-TTL HSS M LED

MODE

+

+

Various cameras support manual flash mode M only in the camera's M mode (manual). In other camera models, an error message appears in the display and the release is locked.

  • Press the ° button and confirm the selected operating mode.
  • Tap the shutter release to transfer data between the flash unit and the camera.
  • Setting the mode of operation
  • Switch on the flash unit with the button. The start screen appears. Thereafter, the flash unit always switches on with the mode of operation that was used last .
  • Press the button and the drop-down menu will appear.
  • Use the buttons to select the operating mode.

M

Page 12 of the Metz mecablitz M400 - Pentax user manual — P-TTL HSS
Pagina 12 · klik om te vergroten
Pagina 12

P 1/16 1.9 m

M

Manual partial light output levels Partial light output can be set in manual flash mode. Setting procedure • Use the buttons to set the desired partial light output (P). The distance information is adju- sted according to how the partial light output is set. The setting is immediately effective and automati- cally saved. The distance display is adjusted to the partial light output automatically (see 5.2).

7.5 Automatic high-speed synchronisation (HSS) Various cameras support automatic high-speed syn- chronisation (see the camera’s operating instructi- ons). This flash mode makes it possible to use a flash unit even with shutter speeds that are faster than the flash sync speed. Interesting results may by achieved in this mode when, for example, a wide open aperture (e.g., f/2.0) is used to limit the depth of field in portrait shots taken in very bright ambient light. The flash unit supports high-speed synchronisation in flash mode. For physical reasons, however, high-speed synchro- nisation significantly reduces the number and the maximum flash range. Be sure to note, therefore, the flash range on the display of the flash unit. High-speed synchronisati- on is activated automatically if a shutter speed faster than the flash sync speed is set on the came- ra, whether manually or automatically by the expo- sure program. Note that in the case of high speed synchronisation the guide number of the flash unit also depends on the shutter speed. The faster the shutter speed, the lower the guide number!

P-TTL HSS

Page 13 of the Metz mecablitz M400 - Pentax user manual — LED
Pagina 13 · klik om te vergroten
Pagina 13

EV +1 1/3

6.9 m

P-TTL HSS

P-TTL P-TTL HSS M

MODE

+

Second curtain synchronisation (2. Curtain) is auto- matically deactivated when the flash unit is set to high-speed synchronisation HSS!

The setting will take effect immediately.

  • Press the ° button and confirm the selected operating mode.
  • Use the buttons to select the operating mode.
  • Setting the mode of operation
  • Switch on the flash unit with the button. The start screen appears. Thereafter, the flash unit always switches on with the mode of operation that was used last.
  • Tap the shutter release to transfer data between the flash unit and the camera.
  • Press the button and the drop-down menu will appear.

P-TTL HSS

E

LED

M LED MASTER

MODE

  • Use the buttons to select the desired brightness. The setting will take effect immediately.
  • Press the ° button and confirm the selected operating mode.
  • Use the buttons to select the operating mode.
  • 7.6 LED Video Light With the LED and video light modes, you can examine recordings of moving pictures at close range. Setting the mode of operation
  • Switch on the flash unit with the button. The start screen appears. Thereafter, the flash unit always switches on with the mode of operation that was used last.
  • Press the button and the drop-down menu will appear.

LED

Page 14 of the Metz mecablitz M400 - Pentax user manual — LOAD
Pagina 14 · klik om te vergroten
Pagina 14

MODE

LOAD SAVE

SERVO F1 F2

F1

  • Press the ° button to confirm the selected storage location.
  • Use the buttons to select .
  • Press the ° button to confirm the selected storage location.
  • 7.7 Favorite programme In flash photography there are always recurring standard situations (e.g. birthday celebrations at home, etc.). The ecablitz permits the settings for such standard situations to be stored as a favorite programme so that the selected flash parameters can be instantly reset. The flash unit has 2 memory locations for saving the settings made on the flash unit. Procedure for saving a favourite programme
  • Set the flash unit parameters as desired. Set the desired operating mode. Set the options for the desired operating mode.
  • Press the button and the drop-down menu will appear.
  • Use the buttons to select the or the storage locations.

SAVE

F2 F1

OK

F1

LOAD SAVE

  • The o.k sign appears on the display.
  • Use the ° button to confirm loading of the favourite mode.
  • Use the buttons to select the or the storage locations.
  • Press the ° button to confirm the selected storage location.
  • Use the buttons to select .
  • Press the button and the drop-down menu will appear.

Procedure for loading a favourite programme

LOAD

F2 F1

Page 15 of the Metz mecablitz M400 - Pentax user manual — EV +1 1/3
Pagina 15 · klik om te vergroten
Pagina 15

+

Light subject against dark background: negative correction factor. Exposure correction by means of alteration of the lens aperture setting is impossible, since the came- ra’s automatic exposure program regards the alte- red aperture setting as the normal working aperture setting. When setting the correction factor, the distance shown in the display can change and be adjusted to the correction factor (depending on the camera model)!

Dark subject against light background: positive correction factor.

8 Manual flash exposure correction The auto flash exposure mode of most cameras is adjusted to a reflection factor of 25% (the average reflection factor of flash subjects). A dark background that absorbs much of the light or a highly reflective bright background (backlit shots, for example) may result in, respectively, underexpo- sure or overexposure of the subject. To offset these effects, the flash exposure can be adjusted manually for the shot with a correction value. The extent of the correction depends on the contrast between the subject and background! In TTL flash modes, manual flash exposure correcti- on factors of from -3 EV (f-stops) to +3 EV (f-stops) can be adjusted on the flash unit in one-third increments. Tip:

EV +1 1/3

6.9 m

P-TTL HSS

+ +

Strongly reflecting objects in the motif can have a negative impact on the camera’s automatic exposu- re. The photograph will be underexposed. Remove reflecting objects or set a positive correction value.

After the shot, remember to cancel the manual flash exposure correction in the camera!

Setting procedure • Press the buttons repeatedly and set an exposure value (EV). The setting will take effect immediately. Manual flash exposure correction is only possible in TTL flash mode if the camera supports this function (consult the camera’s operating instructions)! If the camera does not support this function, the adjusted correction will have no effect. For some camera models, the manual flash exposu- re corrections must be adjusted on the camera. If this is the case, no correction value will appear on the flash unit display.

Page 16 of the Metz mecablitz M400 - Pentax user manual — ZOOM
Pagina 16 · klik om te vergroten
Pagina 16

9.1 Motor zoom reflector The motor zoom reflector of the flash unit can illu- minate lens angles from 24 mm (35 mm format). Thanks to the use of the integrated wide-angle dif- fuser , the illumination widens to 12 mm. 9.1.1 Auto zoom The zoom position of the reflector is automatically adjusted to the lens focal length when the flash unit is used with a camera that transmits the data rela- ted to the lens focal length. Automatic adjustment occurs for lens focal lengths from 24 mm. The automatic adjustment will not be activated if the reflector is swivelled, if the wide-angle diffuser is pulled out, or a Mecabounce (accessory) is mounted. If so desired, the position of the reflector can be manually adjusted in order to achieve particular lighting effects (such as spot effect etc.).

9 Special functions Depending on the camera model or camera group, various special functions are available. For this purpose, data exchange must first occur between the flash unit and camera to access and set the special functions, for example by tapping the shutter release. The setting must occur immediately after accessing the special functions since otherwise the flash unit automatically switches back to normal flash opera- tion after a few seconds!

ZOOM STANDBY

ZOOM

+

  • Press the ° button and confirm the selected setting. The setting will take effect immediately.
  • Use the buttons to select a zoom level.
  • Press the ° button and open the menu.
  • Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

In this case auto-zoom mode is not possible!

9.1.2 Manual zoom mode The zoom position of the reflector must be adjusted manually to the lens focal length when used with a camera that doesnít transmit the data related to the lens focal length.

ZOOM

28mm 35mm 50mm

Page 17 of the Metz mecablitz M400 - Pentax user manual — ZOOM
Pagina 17 · klik om te vergroten
Pagina 17

The following zoom positions are possible for the reflector: 24 - 28 - 35 - 50 - 70 - 85 - 105 mm (35 mm format). Tip: If you do not necessarily need the full guide number and maximum flash range of the flash unit, you can leave the zoom reflector at the position for the shor- test focal length of the zoom lens. This will provide full light coverage of the picture and eliminate the need to continually adjust it to the focal length of the lens. Example: You use a zoom lens with a focal length range of 35 mm to 105 mm. In this case, you set the position of the reflector of the flash unit to 35 mm.

ZOOM AF-BEAM

ZOOM

  • Press the ° button and confirm the selected setting.
  • Use the buttons to select .
  • Press the ° button and open the menu.
  • Press the button and the menu will appear.
  • Use the buttons to select .

Resetting to auto-zoom • Touch the shutter release to begin a data transfer between the flash unit and the camera.

ZOOM

A-ZOOM 24mm · A-Zoom

Page 18 of the Metz mecablitz M400 - Pentax user manual — +
Pagina 18 · klik om te vergroten
Pagina 18

+

The automatic adjustment of the motor-zoom reflector is not activated if the mecabounce is in use. The simultaneous use of the wide-angle diffuser and the mecabounce is not possible.

9.3 mecabounce Diffuser MBM-04 If the mecabounce (optional accessories, see 18) is fitted to the reflector of the flash unit, the reflector is automatically guided to the position required. The distance data and zoom factor are corrected to 12 mm.

9.2 Wide-angle diffuser With the wide angle diffuser , focal lengths of 12mm or more can be illuminated (35 mm format). Pull the wide-angle diffuser out from the reflector as far as it will go, and then release it. The wide-angle diffuser automatically folds downwards. The reflector automatically moves to the required position. The automatic adjustment of the motor-zoom reflec- tor is not activated if the wide-angle diffuser is in use. To insert the wide-angle diffuser , turn it upwards 90° and push it all the way in.

Page 19 of the Metz mecablitz M400 - Pentax user manual — MASTER
Pagina 19 · klik om te vergroten
Pagina 19

10.1 Master mode In remote master mode the master flash unit on the camera controls all slave flash units and also contri- butes to exposure of the shot itself.

10 Cordless flash mode Wireless remote operation is compatible with the Pentax P-TTL remote system. The remote system consists of a master/controller flash unit on the camera and one or more slave flash units. The slave flash unit(s) are controlled via wireless technology by the reflector of the master/controller flash unit. There are four independent remote channels to use so that multiple remote systems in the same room do not interfere with one another. Master/controller and Slave flash units belonging to the same remote system must be set to the same remote channel. The slave flash units must be able to receive the light from the master/controller flash unit with the integrated Sensor for cordless remote control . In remote flash mode, the maximum flash range is not indicated on the flash unit's display panel.

EV

MASTER

LED MASTER SLAVE

MODE

Remote master mode is set.

  • Press the ° button and confirm the selected operating mode.
  • Use the buttons to select the operating mode.
  • 10.1.1 Master mode settings
  • Switch on the flash unit with the button. The start screen appears.
  • Press the button and the drop-down menu will appear.

MASTER

Page 20 of the Metz mecablitz M400 - Pentax user manual — CHANNEL
Pagina 20 · klik om te vergroten
Pagina 20

CHANNEL EV +1 1/3

MASTER

The setting is adopted immediately.

10.1.2 Setting the exposure correction (EV) in P-TTL mode on the master flash unit • Press the buttons repeatedly and set an exposure value (EV).

CHANNEL

ZOOM CHANNEL RESET

  • Press the ° button and confirm the selected setting. The setting will take effect immediately. The channel setting, CH. 3 in the example, can be checked by pressing button ° .
  • Use the buttons to set the desired channel.
  • Press the ° button and open the menu.
  • 10.1.3 Master channel settings There are four independent remote channels to use so that multiple remote systems in the same room do not interfere with one another. Master and Slave flash units belonging to the same remote system must be set to the same remote channel.
  • Press the button and the menu will appear.
  • Use the buttons to select .
Page 21 of the Metz mecablitz M400 - Pentax user manual — CHANNEL
Pagina 21 · klik om te vergroten
Pagina 21

EV

CH. 1

CONTR.

MASTER CONTR. SLAVE

MODE

  • Press the ° button and confirm the selected operating mode. Remote control mode is set.
  • Use the buttons to select the operating mode.
  • 10.2 Controller mode settings In remote control mode the flash of the controller flash unit only assumes the control function and does not contribute to exposure of the shot! 10.2.1 Controller mode settings
  • Switch on the flash unit with the button. The start screen appears.
  • Press the button and the drop-down menu will appear.

CONTR.

CHANNEL

ZOOM CHANNEL RESET

  • Press the ° button and confirm the selected setting. The setting will take effect immediately. The channel setting, CH. 3 in the example, can be checked by pressing button ° .
  • Use the buttons to set the desired channel.
  • Press the ° button and open the menu.
  • 10.2.2 Controller channel settings There are four independent remote channels to use so that multiple remote systems in the same room do not interfere with one another. Control and Slave flash units belonging to the same remote system must be set to the same remote channel.
  • Press the button and the menu will appear.
  • Use the buttons to select .

CHANNEL

Page 22 of the Metz mecablitz M400 - Pentax user manual — SLAVE
Pagina 22 · klik om te vergroten
Pagina 22

+

In slave mode, there is no indication of reach and no automatic adjustment of the zoom position.

10.3 Slave flash mode The flash unit supports Pentax wireless P-TTL Remote System in slave flash mode. At the same time, one or more slave flash units can be remotely controlled from one master/controller flash unit on the camera (e.g. meca-blitz M400 P). So that multiple remote systems in the same room do not interfere with one another, there are four independent remote channels available (CH 1, 2, 3 or 4). Master/controller and slave flash units belonging to the same remote system must be set to the same remote channel. The slave flash units must be able to receive the light from the master flash unit with the integrated sensors for the remote mode . Depending on the camera model, the camera’s internal flash unit can also function as master flash unit.

EV

CH. 1

MODE

SLAVE

CONTR. SLAVE SERVO

In addition, the selected emote channel (e.g. CH. 1) are displayed.

  • Press the ° button and confirm the selected operating mode. Remote slave mode is set.
  • Use the buttons to select the operating mode.
  • 10.3.1 Slave flash mode settings
  • Switch on the flash unit with the button. The start screen appears.
  • Press the button and the drop-down menu will appear..

SLAVE

Page 23 of the Metz mecablitz M400 - Pentax user manual — CHANNEL
Pagina 23 · klik om te vergroten
Pagina 23

CHANNEL

CHANNEL ZOOM

The setting is adopted immediately. OPT.

  • Press the ° button and confirm the selected setting. The setting will take effect immediately. “CH. 3” appears on the display.
  • Use the buttons to set the desired channel.
  • Press the ° button and open the menu.
  • 10.3.2 Setting the slave channel
  • Press the button and the menu will appear.
  • Use the buttons to select .

CHANNEL

EV +1 1/3

CH. 3

SLAVE

10.3.3 Setting the exposure correction (EV) in Slave mode • Press the buttons repeatedly and set an exposure value (EV).

Page 24 of the Metz mecablitz M400 - Pentax user manual — SERVO
Pagina 24 · klik om te vergroten
Pagina 24

+

+

Use a different AF mode of the camera or switch to manual focusing.

When the flash of the camera AF illuminator emits the auto focus servo operation is not possible. Disable the AF measuring beam on the camera

10.4 SERVO mode SERVO mode is a simple slave mode without or with complete pre-flash suppression in which the slave flash unit always triggers a flash as soon as the camera flash unit receives a light pulse. In SERVO mode, only manual flash mode is possi- ble. Manual flash mode is automatically activated after switching to SERVO mode.

P 1/1

MODE

SERVO

SLAVE SERVO F1

If desired, partial light output can be set, see 10.4.3.

  • Press the ° button and confirm the selected operating mode. The mode of operation is adopted.
  • 10.4.1 Setting SERVO flash mode
  • Press the button and the drop-down menu will appear.
  • Use the buttons to select the operating mode.

SERVO

Page 25 of the Metz mecablitz M400 - Pentax user manual — SYNC
Pagina 25 · klik om te vergroten
Pagina 25

P 1/1

SERVO

LEARN

SYNC

SYNC ZOOM

  • Press the ° button and confirm the selected setting. The mode of operation is adopted. If the synchronisation set here does not work properly, then proceed as described in 10.4.4.
  • Use the buttons to select the desired synchronisation mode. Synchronisation without pre-flash
  • Press the ° button and open the menu.
  • 10.4.2 Pre-flash suppression or synchronisation settings
  • Press the button and the menu will appear.
  • Use the buttons to select .

SYNC

P 1/1

+

SERVO

Slave groups and remote channels cannot be set in SERVO mode. The camera flash unit may not work in the remote mode.

Once the slave flash units have achieved flash-rea- diness, the AF measurement flash flashes.

10.4.3 Servo mode partial light output settings • Use the buttons to set the desired partial light output (P). The partial light output is adopted.

Synchronisation with pre-flash

Page 26 of the Metz mecablitz M400 - Pentax user manual — LEARN
Pagina 26 · klik om te vergroten
Pagina 26

+

+

If possible, use another camera mode or change to manual focussing.

If the camera’s own flash device provides for auto- matic focussing AF measuring flashes, then due to the system characteristics no learn operation is possible.

10.4.4 Learn function The “Learn function” enables individual automatic adjustment of the servo flash unit to the flash tech- nology of the camera’s flash unit. In the process, one or more pre-flashes, e.g. to reduce the “red-eye effect” of the camera flash unit can be taken into account. The slave flash unit is then fired to coincide with the main flash that illuminates the actual picture.

LEARN

LEARN

SYNC ZOOM

SYNC

  • Press the release button on the camera so that the camera’s own flash unit is activated. If the SERVO flash unit has received a light pulse, then "OK" appears in the display as confirmation. The macablitz has learned the flash of the camera flash unit.
  • Press the ° button and confirm the selected setting.
  • "Learn Mode" is ready to learn.
  • Use the buttons to select .
  • Press the ° button and open the menu.
  • Setting procedure for the learn function The AF pre-flash function of the camera must be switched off.
  • Press the button and the menu will appear.
  • Use the buttons to select .

LEARN

SYNC

Page 27 of the Metz mecablitz M400 - Pentax user manual — ZOOM
Pagina 27 · klik om te vergroten
Pagina 27

ZOOM STANDBY

ZOOM

  • Press the ° button and confirm the selected setting. The setting is adopted immediately.
  • Use the buttons to set the desired zoom level, e.g. .
  • Press the ° button and open the menu.
  • 11.2 Manual Zoom Operation With manual A-zoom operation, the zoom-head position of the reflector must be manually adjusted to the focal length of the camera. Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

11.1 Automatic Zoom Operation (A-ZOOM) With A-zoom operation, the zoom-head position of the reflector is adjusted to the focal length of the camera.

11 OPTION menu

ZOOM

11.3 AF auxiliary light (AF-BEAM) If the AF metering system of a digital AF reflex came- ra is unable to focus due to insufficient ambient lighting, the camera activates the AF auxiliary light built into the flash unit. With the "AF-BEAM" function, the AF auxiliary light can be switched on or off. Parallax error between the lens and AF auxiliary light limits the close-up range with the AF auxi- liary light to approximately 0.7 m to 1 m. If the automatic AF auxiliary light is to be activated by the camera, the "Single-AF (S-AF)" autofocus mode must be set on the camera and the flash unit must indicate flash readiness. Some camera models support only the camera's internal AF auxiliary light. In this case, the automa- tic AF auxiliary light of the flash unit is not activated (as in the case of compact cameras; see the came- ra's operating instructions). Low-speed zoom lenses can significantly curtail the range of the AF auxiliary light! Some cameras support the AF auxiliary light in the flash unit only with the camera's central AF sensor.

28mm 35mm 50mm · 35mm

Page 28 of the Metz mecablitz M400 - Pentax user manual — OFF
Pagina 28 · klik om te vergroten
Pagina 28

AF-BEAM

STANDBY AF-BEAM DISPLAY

OFF ON

  • Press the ° button and confirm the selected setting. The setting is adopted immediately.
  • Use the buttons to select or .
  • Press the ° button and open the menu.
  • Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

OFF

AF-BEAM

ON

+

Use a tripod to avoid blurred images!

11.4 Second curtain synchronisation (2. CURTAIN) Some cameras offer the option of second-curtain synchronisation (2. CURTAIN), in which the flash unit is not triggered until the end of the exposure time. This is particularly advantageous when used with lower shutter speeds (slower than 1/30 sec.) and moving subjects that have their own source of light. With second-curtain synchronisation, a moving light source will trail a light streak instead of buil- ding one up ahead itself, as it does when the flash is synchronised with the first shutter curtain. In this way a „more natural“ image of the photographic situation is produced! Depending on its operating mode, the camera sets shutter speeds slower than its sync speed. On some cameras the 2. CURTAIN function is not possible in certain operating modes (e.g., certain vari- or subject programs, or with red eye reducti- on). In these cases, the 2. CURTAIN mode cannot be selected and/or is automatically cancelled or igno- red (see camera’s operating instructions).

Page 29 of the Metz mecablitz M400 - Pentax user manual — P-TTL
Pagina 29 · klik om te vergroten
Pagina 29

EV

7,9 m

2.CURTAIN

P-TTL

1.CURTAIN 2.CURTAIN

SYNC

SYNC ZOOM

The setting is adopted immediately.

  • Press the ° button and confirm the selected setting.
  • Use the buttons to select .
  • Press the ° button and open the menu.
  • Press the button and the menu will appear.
  • Use the buttons to select .

Setting procedure • Set the flash mode , see 7.2.

P-TTL

2.CURTAIN

SYNC

Page 30 of the Metz mecablitz M400 - Pentax user manual — 12 Flash techniques
Pagina 30 · klik om te vergroten
Pagina 30

+

When the reflector head is given, there is no indica- tion of reach and no automatic adjustment of the reflector position.

12.1 Bounce flash Bounce flash illuminates the subject more softly and reduces dense shadows. It also reduces the drop in light from foreground to background that occurs for physical reasons. The reflector of the flash unit can be swivelled hori- zontally and tilted vertically for bounce flash. To avoid colour cast in your shots, the reflective sur- face should be colour-neutral or white. When tilting the reflector vertically, make sure that it is turned through an angle that is wide enough to prevent direct light from falling on the subject. For this reason the reflector should be tilted at least as far as the 60° lock-in position. When the reflector head is tilted, the reflector is moved to a position of 70 mm in order to prevent the subject from being additionally illuminated by dispersed light .

12 Flash techniques

  • 12.2 Bounce flash with a reflector card The use of bounce flash with the integrated reflector card can bring out highlights in the eyes of human subjects:
  • Tilt the reflector head upwards by 90°.
  • Pull the reflector card together with the wideangle diffuser from above out of the reflector head and forwards.
  • Hold the reflector card and push the wideangle diffuser back into the reflector head.
Page 31 of the Metz mecablitz M400 - Pentax user manual — 13 Flash synchronisation
Pagina 31 · klik om te vergroten
Pagina 31

+

13.1 Automatic flash sync speed control Depending on the camera model and camera mode, the shutter speed is switched to flash sync speed when flash readiness is reached (see the camera’s operating instructions). Shutter speeds cannot be set faster than the flash sync speed, or they are switched automatically to the flash sync speed. Various cameras have a sync speed range, for example from 1/60 sec to 1/250 sec (see the camera’s operating instructions). The sync speed set by the camera depends on the camera mode, the ambient light, and the focal length of the lens used. Shutter speeds slower than the flash sync speed can be set according to the camera mode and the selected flash synchronisation. If a camera with a between-the-lens shutter and high-speed synchronisation (see 7.5) is used, flash sync speed is not controlled automatically. As a result, the flash can be used at all shutter speeds.

13 Flash synchronisation

13.3 Slow synchronisation (SLOW) A slow exposure (SLOW) gives added prominence to the image background at lower ambient light levels. This is achieved by adjusting the shutter speed to the ambient light. Accordingly, shutter speeds that are slower than the flash sync speed (e.g., shutter speeds up to 30 sec.) are automatically adjusted by the camera. Slow synchronisation is activated auto- matically on some camera models in connection with certain camera programs (e.g., a night shot program, etc.), or it can be set on the camera (see the camera’s operating instructions). No settings are necessary on the flash unit, nor is there any dis- play for this mode. Slow synchronisation SLOW is set on the camera (see camera’s operating instructions)! Use a tripod when shooting with slow shutter speeds to avoid blurred images!

13.2 Normal synchronisation In normal synchronisation the flash unit is triggered at the beginning of the shutter time (first curtain synchronisation). Normal synchronisation is the standard mode on all cameras. It is suitable for most flash shots. The camera, depending on the mode being used, is switched to the flash sync speed. Speeds between 1/30 sec. and 1/125 sec. are customary (see the camera’s operating instructi- ons). No settings are necessary on the flash unit, nor is there any display for this mode.

Page 32 of the Metz mecablitz M400 - Pentax user manual — UNIT
Pagina 32 · klik om te vergroten
Pagina 32

DISPLAY

AF-BEAM DISPLAY UNIT

LOW HIGH

  • Press the ° button and confirm the selected setting. The setting is adopted immediately.
  • Use the buttons to select the or the settings.
  • Press the ° button and open the menu.
  • 14.1 Brightness The screen brightness can be changed in 2 levels. Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

14 Display settings

HIGH

DISPLAY

LOW

DISPLAY UNIT RESET

UNIT

  • Press the ° button and confirm the selected setting. The setting is adopted immediately.
  • Use the buttons to select the or the settings.
  • Press the ° button and open the menu.
  • 14.2 Range display in m or ft (UNIT) The range indication in the display can either be shown in metres (m) or feet (ft). Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

UNIT

m ft · ft · m

Page 33 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 33 · klik om te vergroten
Pagina 33

15.2 Conditioning the flash capacitor The flash capacitor built into the flash unit undergo- es a physical change when the device has not been used for a long time. For this reason it is necessary to switch the device every three months for approx. 10 mins. The power supplies must deliver enough power so that flash standby lights up no later than 1 min after swit- ching on.

15.1 Firmware updates The firmware version (V.10 in the example) of the flash unit is shown in the start screen after swit- ching on. The flash unit’s firmware can be updated through the Micro USB port and adjusted to the technical requirements of future cameras (Firmware Update). For more information, visit the Metz homepage at www.metz-mecatech.de.

  • 15 Care and maintenance
  • The screen surface should only be cleaned with a soft, dry cleaning cloth (e.g. microfibre cloth).
  • If significant soiling nevertheless occurs, the screen surface can be cleaned with a slightly moist soft cloth. Never spray cleaning fluid on the surface of the screen! If cleaning fluid penetrates into the frame of the screen, the components there will be damaged beyond repair.

RESET

UNIT RESET MANUAL

NO YES

This will not affect the firmware updates for the flash unit!

  • Press the ° button and confirm the selected setting. All settings are adopted immediately and the flash unit is reset to its factory settings.
  • Use the buttons to select .
  • Press the ° button and open the menu.
  • 15.3 Reset The flash unit can be reset to the factory settings when delivered. Setting procedure
  • Press the button and the menu will appear.
  • Use the buttons to select .

RESET

YES

Page 34 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 34 · klik om te vergroten
Pagina 34
  • 16 Troubleshooting Should the flash unit fail to function properly or meaningless content appear on the flash unit display panel, switch the flash unit off with the main switch for approximately 10 seconds. Check the camera settings and make sure the foot of the flash unit is mounted correctly in the camera’s accessory shoe. Replace the batteries with new or freshly charged batteries. The flash unit should function normally again once it is switched back on. If this is not the case, contact your local dealer. Below is a list of some of the problems that may occur when the flash unit is used. For each item, possible causes and remedies for the problem are listed. No maximum flash range indication appears on the display panel.
  • There has been no exchange of data between the flash unit and the camera. Tap the camera’s shutter release.
  • The reflector is not in normal position.
  • The flash unit has been set to remote operation.
  • The flash unit operates in AUTO flash mode. The AF measuring beam of the flash unit is not activated.
  • The flash unit is not ready for firing.
  • The camera is not in „Single-AF (S-AF)“ mode.
  • The camera supports only its own internal AF measuring beam.
  • The "AF BEAM" is switched off. Switch on "AF BEAM", see 11.3
  • The reflector position is not automatically adjusted to the current zoom position of the lens.
  • The camera does not transfer data to the flash unit
  • There is no exchange of data between the flash unit and the camera . Tap the camera’s shutter release.
  • The camera is equipped with a lens without CPU.
  • The reflector is swivelled out of its locked normal position.
  • The wide-angle diffuser folds out from the reflector.
  • A Mecabounce is mounted in front of the reflector.
  • The flash unit has been set to remote operation. The setting for manual P-TTL flash exposure correction has no effect.
  • The camera does not support manual P-TTL flash exposure correction on the flash unit.
  • The minimum distance (10% of maximum range) has not been reached. Automatic switching to the flash sync speed fails to occur.
  • The camera has a between-the-lens shutter (as do most compact cameras), Switching to sync speed is therefore unnecessary.
  • The camera operates with high-speed synchronisation HSS (camera settings). Switching to sync speed does not occur in the process.
  • The camera operates with shutter speeds that are slower than the flash sync speed. Depending on the camera mode, there is no switch to flash sync speed (see the camera’s operating instructions).
Page 35 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 35 · klik om te vergroten
Pagina 35
  • The shots are too dark.
  • The subject is beyond the range of the flash unit. Note: Using bounce flash reduces the range of the flash unit.
  • The subject contains very bright or highly reflective areas. The metering system of the camera or flash unit is deceived as a result. Set a positive manual flash exposure correction, e.g., +1 EV. The shots are too bright.
  • In close-up shots, overexposure (shots that are too bright) may result if the shutter speed is faster than the flash sync speed.
  • The minimum distance (10% of maximum range) has not been reached.
  • The subject contains very dark or low reflectance areas of the image. Through this circumstance, the measurement system of the camera or flash unit is deceived. Set a negative manual flash exposure, for example, -1 EV.
Page 36 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 36 · klik om te vergroten
Pagina 36

Light coverage: Reflector from 24 mm (35 mm format) Reflector with wide-angle diffuser from 12 mm (35 mm format) Swivelling ranges and locking positions of the reflector: upwards: 45° 60° 75° 90° counter-clockwise: 60° 90° 120° 150° 180° clockwise: 60° 90° 120° 150° 180°

Recycling timesee table 4, page (Page 258)
Synchronisationlow-voltage ignition Number of flashes: see table 4, page (Page 258)
Sensitivity to lightISO 6 to ISO 51200
Colour temperatureCa. 5600 K

17 Technical data Max. guide numbers at ISO 100/21°, zoom 105 mm: In the metric system: 40 In the imperial system: 131 Flash modes: AUTO, P-TTL, manual M, high-speed synchronisation HSS, LED video light, Master flash mode, Control flash mode, Slave flash mode, Servo mode. Manual partial light output levels: P1/1 . . . P1/ 256 in one-third increments. Flash durations: see table 2, page (Page 257)

Video light: - Illumination: 100 lx at a distance of 1M - Dimming range: 1/1, 1/2, 1/4, 1/8, 1/16, 1/32 - Colour temperature: min. 5000 K - Illumination: 54° corresponds to 35 mm focal length with regard to 35mm format 24 x 36 - Illumination duration: Around 4 hours with NiMH rechargeable (2100 mAh) batteries and full light output. Dimensions, approx., in mm (W x H x D): Ca. 65 x 92,2 x 86,8 Weight : Flash unit without batteries approx. 220 g Included: Flash unit with integrated wide-angle diffuser, Flash unit mounting foot, Belt pouch, Quick Guide.

Page 37 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 37 · klik om te vergroten
Pagina 37

Including front and background diffusers, carrying case and Bowens- compatible adapter to connect to a Metz TL or BL studio flash device

Dimensions40 × 40 cm

(Order No. 009014047)

  • Easy Softbox ESB 40-40

Including front and background diffusers, carrying case and Bowens- compatible adapter to connect to a Metz TL or BL studio flash device

Dimensions60 × 60 cm

(Order No. 009016076)

  • 18 Optional accessories We accept no liability for malfunctions of or damage to the flash unit caused by the use of accessories of other manufacturers!
  • mecabounce Diffuser MBM-04 (Order No. 00000490A) With this diffuser, soft lighting can be achieved in a very simple manner. It gives your pictures a marvellous soft appearance. Skin tones are captured more faithfully. The maximum working range is reduced by about half in conformity with the loss of light.
  • Flash unit mounting foot S60 (Order No. 000000607) Flash unit mounting foot for slave mode.
  • Easy Softbox ESB 60-60

Connects to Metz lighting tripods LS-247 and LS-200

Adjustable flash foot height

Adapter for compact flash devices and Easy Softboxes

(Order No. 009094065)

  • Flash device holder FGH 40-60

Errors excepted. Subject to changes !

Page 38 of the Metz mecablitz M400 - Pentax user manual — RESET
Pagina 38 · klik om te vergroten
Pagina 38

Disposal of batteries Do not dispose of spent batteries with domestic rubbish. Please return spent batteries to collecting points should they exist in your country! Please return only fully discharged batteries. Normally, batteries are fully discharged if: - the device they powered switches itself off and indicates "Spent Batteries". - they no longer function properly after prolonged use. To ensure short-circuit safety please cover the battery poles with adhesive tape.

Page 39 of the Metz mecablitz M400 - Pentax user manual —
Pagina 39 · klik om te vergroten
Pagina 39
Metz mecablitz M400 - Pentax — RESET diagram (page 39)
Afb. 1

Metz mecablitz M400 - Pentax —  diagram (page 39)
Afb. 2
Metz mecablitz M400 - Pentax —  diagram (page 39)
Afb. 3
Page 40 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 40 · klik om te vergroten
Pagina 40

Integrated sensors for the remote mode

Cursor keys:

ON / OFF button

USB socket (micro)

Battery compartment (4x AA – see safety information)

AF auxiliary light

LED video light

Wide angle diffuser disk (recessed)

Reflector card (recessed)

lights red in standby

lights up green when reaching the flash readiness

Selection of menu items and value adjustment

Show 5 more labels / short text on this page
Knurled nut · OLED display · Confirmation/info key · Options menu · Flash modes
Page 41 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 41 · klik om te vergroten
Pagina 41
Page 41 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Page 42 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 42 · klik om te vergroten
Pagina 42
Page 42 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Page 43 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 43 · klik om te vergroten
Pagina 43

Tabelle 4: Blitzfolgezeiten und Blitzanzahl bei den versch. Batterietypen Tableau 4: Temps de recyclage et autonomie pour différents types de piles Tabel 4: Flitsvolgtijden en aantallen flitsen bij de verschillende voedingstypes Table 4: Recycling times and number of flashes with different battery types Tabella 4: Tempi di ricarica e numero lampi con i diversi tipi di batterie Tabla 4: Tiempos de secuencias de dest. y núm. de dest. con los dist. tipos de pilas

Lithium Batterie 3,2 s 0,1 . . . 3,2 s 600

NiMh-Akku 1,5 s 0,1 . . . 1,5 s 320 1,2 V, 1900 mAh0

Alcal. al mangan. ad alta capacità

High-power 2,4 s 0,1 . . . 2,4 s 340 alkaline-manganese

Alcaline au Mg hautes perf.

Batterietyp Blitzfolgezeiten Blitzanzahl Type de pile/accu Temps de recyclage Nombre díéclairs Type voeding Flitsvolgtijden Aantal flitsen Battery type Recycling times Number of flashes Tipo batterie Tempi di ricarica Numero ampi Tipo de pila Tiempo de secuencia de dest. Número de destellos M TTL min. /max.

Alcalino-Manganesas High power · High Power alkalimangaan · High Power Alkali-Mangan

Page 44 of the Metz mecablitz M400 - Pentax user manual — ö
Pagina 44 · klik om te vergroten
Pagina 44

ö

j

Il vostro prodotto Metz è stato progettato e realizzato con mate- riali e componenti pregiati che possono essere riciclati e riutiliz- zati. Questo simbolo significa che gli apparecchi elettrici ed elettro- nici devono essere smaltiti separatamente dai rifiuti domestici alla fine del loro utilizzo. Vi preghiamo di smaltire questo apparecchio negli appositi pun- ti di raccolta locali o nei centri preposti al riciclaggio. Contribuite anche voi a tutelare l’ambiente nel quale viviamo.

Votre produit Metz a été conçu et fabriqué avec des maté- riaux et composants de haute qualité, susceptibles d'être recyclés et réutilisés. Ce symbole signifie que les appareils électriques et élec- troniques, lorsqu'ils sont arrivés en fin de vie, doivent être éliminés séparément des ordures ménagères. Veuillez rapporter cet appareil à la déchetterie communa- le ou à un centre de recyclage. Vous contribuez ainsi à la préservation de l'environne- ment.

Ihr Metz-Produkt wurde mit hochwertigen Materialien und Komponenten entworfen und hergestellt, die recycelbar sind und wieder verwendet werden können. Dieses Symbol bedeutet, dass elektrische und elektroni- sche Geräte am Ende ihrer Nutzungsdauer vom Hausmüll getrennt entsorgt werden müssen. Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen kom- munalen Sammelstelle oder im Recycling Centre. Bitte helfen Sie mit die Umwelt, in der wir leben, zu erhal- ten.

Su producto Metz ha sido concebido y fabricado con materia- les y componentes de alta calidad, que pueden ser reciclados y reutilizados. Este símbolo significa que los aparatos eléctricos y electróni- cos, al final de su vida útil, deberán ser separados de los resi- duos domésticos y reciclados. Rogamos llevar este aparato al punto de recogida de su muni- cipio o a un centro de reciclaje. Por favor, contribuya Vd. también en la conservación del ambiente en que vivimos.

Your Metz product was developed and manufactured with high-quality materials and components which can be recycled and/or re-used. This symbol indicates that electrical and electronic equip- ment must be disposed of separately from normal garbage at the end of its operational lifetime. Please dispose of this product by bringing it to your local col- lection point or recycling centre for such equipment. This will help to protect the environment in which we all live.

Uw Metz-product is ontworpen voor en gebouwd uit hoog- waardige materialen en componenten die gerecycled kunnen worden en dus geschikt zijn voor hergebruik. Dit symbool betekent, dat elektrische en elektronische appa- ratuur aan het einde van zijn levensduur gescheiden van het huisvuil apart moet worden ingeleverd. Breng dit apparaat naar een van de plaatselijke verzamelpun- ten of naar een kringloopwinkel. Help s.v.p. mee, het milieu waarin we leven te beschermen.

Page 45 of the Metz mecablitz M400 - Pentax user manual — ö
Pagina 45 · klik om te vergroten
Pagina 45

Within the framework of the CE approval symbol, correct exposure was evaluated in the course of the electromagnetic compatibility test. Do not touch the SCA contacts ! In exceptional cases the unit can be damaged if these contacts are touched.

Im Rahmen des CE-Zeichens wurde bei der EMV-Prüfung die korrekte Belichtung ausgewertet. SCA-Kontakte nicht berühren ! In Ausnahmefällen kann eine Berührung zur Beschädigung des Gerätes führen.

j Remarque:

Nell’ambito delle prove EMV per il segno CE è stata valutata la corretta esposizio- ne. Non toccate mai i contatti SCA ! In casi eccezionali il toccare può causare danni all’apparecchio.

L’exposition correcte a été évaluée lors des essais de CEM dans le cadre de la certification CE. Ne pas toucher les contacts du SCA! Il paut arriver que le contact avec les doigts provoque la dégradation de l’appareil.

ö

El símbolo CE significa una valora ción da exposición correcta con la prueba EMV (prueba de tolerancia electroma- gnética). No tocar los contactos SCA ! En algunos casos un contacto puede producir daños en el aparato.

In het kader de CE-markering werd bij de EMV-test de correcte belichting bepaald. SCA Contacten niet aanraken ! In uitzonderlijke gevallen kan aanraken leiden.

Atención:

Page 46 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 46 · klik om te vergroten
Pagina 46
Page 46 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Page 47 of the Metz mecablitz M400 - Pentax user manual —  Cursor keys:
Pagina 47 · klik om te vergroten
Pagina 47

716 47 0141.A1 j l x k ö c Metz - always first class.

Metz mecablitz M400 - Pentax —  Cursor keys: diagram (page 47)
Afb. 4 · Cursor keys:
Metz mecablitz M400 - Pentax —  Cursor keys: diagram (page 47)
Afb. 5 · Cursor keys:
  • Metz mecatech GmbH
  • Ohmstraße 55
  • 90513 Zirndorf / GERMANY
  • <a href="http://www.metz-mecatech.de" rel="nofollow noopener" target="_blank">www.metz-mecatech.de</a>
  • [email protected]
Metz mecablitz M400 - Pentax —  Cursor keys: diagram (page 47)
Afb. 6 · Cursor keys:
Metz mecablitz M400 - Pentax —  Cursor keys: diagram (page 47)
Afb. 7 · Cursor keys:

mecablitz mecalight · mecastudio

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Metz mecablitz M400 - Pentax

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Metz mecablitz M400 - Pentax

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Metz mecablitz M400 - Pentax handleiding-pdf

262 pagina's·2.7 MB·Flitsers·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…