




82 A
Instruction manual / Manual de instrucciones /
En Fr Pt Es

Español.............................. p. 12-19
Français............................. p. 20-27
Português brasileiro........ p. 28-35
![Page 3 of the Nikon PROSTAFF 5 - 82A user manual — [60/82]](/cdn/reader/af/af6b0504a1249f5b7797b7fb3f23d070b6eba813d0850b233c581fccca0f7a0f/images/page-3.webp?w=400)
![Nikon PROSTAFF 5 - 82A — [60A/82 A] diagram (page 3)](/cdn/reader/af/af6b0504a1249f5b7797b7fb3f23d070b6eba813d0850b233c581fccca0f7a0f/images/rimg-5.webp)
![Nikon PROSTAFF 5 - 82A — [60A/82 A] diagram (page 3)](/cdn/reader/af/af6b0504a1249f5b7797b7fb3f23d070b6eba813d0850b233c581fccca0f7a0f/images/rimg-6.webp)
![Nikon PROSTAFF 5 - 82A — [60A/82 A] diagram (page 3)](/cdn/reader/af/af6b0504a1249f5b7797b7fb3f23d070b6eba813d0850b233c581fccca0f7a0f/images/rimg-7.webp)

!p


To keep your Fieldscope in excellent condition, Nikon Vision recommends regular servicing by an authorized dealer.

1 Mounting on a tripod (regular type for camera)
Please refer to the numbered images on page 3.
screw of the tripod with the tripod mount of the Fieldscope, and firmly tighten the screw. Choose a solid tripod of medium size or larger, that can stand the weight of the Fieldscope wind pressure, as well as being vibration-free.
1 Objective lens 2 Lens hood 3 Aiming line 4 Body 5 Focusing knob 6 Eyepiece (optional accessory) 7 Mount cap 8 Lens mount (bayonet) 9 Tripod mount !p Objective lens cap
tube. • When not in use, snap the cap onto the objective tube.
Items supplied ・Main body x 1 ・Objective lens cap x 1 ・Mount cap x 1 ・Stay-on case x 1 ・Case strap (removable) x 1

Fig. 1 Inward Outward
(Fig. 1)

conditions, prevent water droplets on the objective lens and to protect it, slide the lens hood outward until it stops. • To retract the lens hood, slide the lens hood in
toward the body until it stops. After the lens hood has been fully retracted, re-attach the objective lens cap to the objective tube.

SEP-20-60 eyepiece.

mount. • To attach the eyepiece, align the index marks on
the eyepiece and the main body. Next, insert the eyepiece into the mount and turn counterclockwise until you hear it “click.” (Fig. 2) • To remove the eyepiece lens, turn the eyepiece
clockwise while pushing the release button on the main body. (Fig. 3) *Spotting Scope RAIII eyepieces (Bayonet type) can be used with the PROSTAFF 5 Fieldscope.
1 Push 2 Turn counterclockwise 3 Push release button 4 Turn clockwise
Lens hood · Release button · Index mark

5 Eyepiece cup
Fig. 4 1
(Fig. 4)

are all equipped with a turn-slide type rubber eyecup. Eyeglass wearers should always turn the rubber eyecup clockwise to use in the fully retracted position. For those who do not wear eyeglasses, turn the rubber eyecup counterclockwise to use in the fully extended position.
For eyeglass wearers For those who do not wear eyeglasses
1 Turn-slide eyepiece cup 2 Screwed in 3 Screwed out
eyepiece with one eye. • When targeting the subject, the aiming line on the hood is useful to take an approximate sight.
(Fig. 5)

Fieldscope body. Viewing distant subjects: Rotate the focusing knob clockwise. Viewing near subjects: Rotate the focusing knob counterclockwise.
1 Distant 2 Near 3 Focusing knob

Eyepieces
SEP-25 SEP-38W SEP-20-60
*When attaching the digital camera bracket for digiscoping, make sure the eyepiece is fully retracted, otherwise the eyepiece or camera may be damaged due to incorrect connection or may become loose and fall, resulting in possible injury. If the orange line is visible, it is NOT retracted enough.
(fully retracted) (NOT retracted enough)
Orange line

PROSTAFF 5 Fieldscope Specifications

* The number calculated by the formula [tan ω' = Γ x tanω ]: Apparent field of view: 2ω', Magnification:Γ, Real field of view: 2ω ** At lowest magnification. Water-resistant models (Eyepiece lens with main body.): In normal use, there will be no water penetration (As tested by water equivalent to more than 1mm per minute, falling from a height of more than 200mm for a duration of 10 minutes).
Drops of water and other types of moisture will not damage the Fieldscope, but be sure to observe the following during use: 1. The unit is neither waterproof nor airtight, so it should not be held under running water or used in rainy conditions. 2. Movable parts (focusing knob, eyepiece, etc.) of the Fieldscope should not be adjusted in wet conditions. If you notice moisture has accumulated on the product’s surface, gently wipe it off immediately.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.