The Dino® 3 mobility base for seating shells is designed solely for use with seating systems for people who are unable to walk or who have a walking impediment. It can be moved either by the patient or by another person. The Otto Bock Warranty applies only when the product is used according to the specified conditions and for the intended purposes, following all manufacturer’s recommendations.
This product meets the requirements of the 93/42/EWG guidelines for medical products. This product has been classified as a class I product according to the classification criteria outlined in appendix IX of the guidelines. The declaration of conformity was therefore created by Otto Bock with sole responsibility according to appendix VII of the guidelines.
Thank you very much for your decision to use an Otto Bock HealthCare product. In order to ensure that you will be completely satisfied when using this product, please read the following instructions. The design, as described in these Instructions for Use, is subject to technical alterations without notice. If there are any questions, do not hesitate to ask your rehabilitation technology supplier. The “Accessories” section (page 21) presents additional parts for the Dino® 3, which may extend the range of appli- cation and increase comfort. The “Adjustability / Assembly Instructions” section (page 23) describes the possibilities of adjusting the mobility base to your individual requirements.
To avoid potentially dangerous situations such as tipping, you should become familiar with your new mobility base with seating shell on level ground first.
Do not use the footrests as a stepstool when getting into or out of your mobility base with seating shell.
Get to know how the mobility base reacts when the center of gravity shifts; for example on slopes or inclines or when clearing obstacles, like steps and curbs. This should be done only with assistance from another person. Using the anti-tipper is strongly recommended for untrained wheelchair users.
Park the mobility base with seating shell only on level surfaces. If you have to park it on an incline, make sure that you bring the seat to an upright position because there is a risk that it can tip over backwards when in a reclined position.
Please note, that the seat may only be tilted with the anti-tipper in operational position.
When reaching for objects in front, side or behind the wheelchair, be sure the patient does not lean out of the seating shell too far since the shift in the center of gravity might cause the chair to tilt or tip over.
Use your mobility base with seating shell properly. For instance, do not jump it down from higher surfaces and do not drive against obstacles (including steps, curbs) without braking.
The anti-tipper is a component that has been designed to prevent the wheelchair from tipping over backwards. The anti-tipper should never be used to support the back of the wheelchair with the rear wheels removed.

Stairs should be ascended/descended only with assistance from attendants. If devices such as ramps or elevators are available, they should be used. If such devices are missing, two helpers must carry the wheelchair over the obstacle. If only one helper is available, this person should adjust the anti-tipper (if mounted) in such a way that the anti-tipper does not contact the steps during transport. This will help avoid a potential fall. Afterwards, the anti-tipper should be correctly readjusted. When using lift- ing platforms with mounted anti-tipper, be certain that the anti-tipper is inside the standing area of the lifting platform.
Be certain that your mobility base with seating shell is lifted by the attendants only at firmly attached components (for example not at the footrest).
Make sure that the clamping levers of the height adjustable push handles (Fig. 8, item 3) are firmly tightened.
Engage your locks when standing on uneven ground or when transferring (e.g. to a car).
Models with push rings can be additionally equipped with wheel locks.
The effectiveness of the wheel locks and the general driving ease are dependent on adequate air pres- sure. Correctly inflated rear wheels and equal air pressure on both wheels of one axle considerably improve maneuverability of your mobility base with seating shell.
Therefore, before starting a journey in your wheelchair, check the pneumatic tires for proper inflation lev- els. The correct air pressure is printed on the side wall of the tire (or see air pressure table on page 26). Efficiency of the wheel locks can only be ensured if sufficient air pressure and correct adjustment (10 mm distance at the maximum, subject to technical alterations) have been provided.
All brakes acting on the tires do not serve as service brake but are only designed as parking brake (wheel lock).
Make sure the tires have sufficient tread depth.
We would like to point out that persons seated in seating shells must at all time be secured with suitable safety systems (straps/belts).
With some combinations or adjustment versions it might happen that the casters collide with the footrest. Please note that if this is the case the steering range of your casters is limited and change the settings if need be.
Please note that when using your wheelchair in public traffic, you are subjected to observe the traffic regulations according to the vehicle regulations for your area.
Be sure you are visible in the dark. If possible, wear light clothes. We recommend attaching other lights as well.
For transfemoral amputee users, the rear wheels must be placed to the posterior. Use of an anti-tipper is required.

To avoid hand injuries, do not grip between rear wheel and wheel lock while maneuvering your mobility base with seating shell.
Be careful with your fingers when using the mobility base with seating shell or during adjustment and assembly works (risk of injuries).
Be sure to re-tighten the screws after all adjustments.
Maximum load including seating shell is 120 kg.
Your hands may become warm due to slowing down from high speed or on longer slopes. This is es- pecially true if the push rings are aluminum.
When using your mobility base with seating shell outdoors, wear leather gloves. Gloves provide you with a better grip and protect your fingers from dirt and hot metal.
Using your Otto Bock Product as a Seat in Motor Vehicles
We recommend that, wherever and whenever possible, users transfer to the seats installed in the mo- tor vehicle and use the corresponding vehicle restraint systems, because this is the only way to ensure optimum protection of the passengers in case of an accident.
It is, however, possible to use your Otto Bock product Dino® 3 as a seat in a motor vehicle, provided that the Otto Bock safety elements and appropriate restraint systems are used. For more information, please refer to our instructions for use: “Using your wheelchair/ mobility base with seating shell or buggy as a seat in motor vehicles”, article number: 646D158.
When using seating systems of other manufacturers, please observe the corresponding manufacturer’s instructions for use. Otto Bock will assume no liability for combinations of interface adapters which are not mentioned above.
Removing and mounting seating systems being equipped with the “Parallel” seating shell interface (Fig. 2) The seat can be easily removed from the mobility base to lessen the weight of the chair during transport. This also allows for easy transfer between indoor and outdoor mobility bases. Position yourself on the right side (when in the forward direction) of the seating unit. Hold the head area of the back part of the seat with one hand. Now reach beneath the seat and pull the angled disengaging lever towards the footrest assembly to release the seat attachment. Tilt the seat back to over 45° and remove it by lifting upwards. To remount the seat onto the mobility base, hold the seat as described above and first put the locking unit at an angle of approx. 45° on the posterior tube of the seat adapter. Press the anterior seat edge onto the mobility base until the seat audibly snaps in place. Make sure it’s secure by giving the seat a few short tugs.
Removing and mounting seating systems that have a Trapez seating shell interface (Fig. 4) For transport in a car or to distribute the weight into two, more manageable loads, the seat can be easily removed from the mobility base. This also allows for easy transfer of the seat between indoor and outdoor mobility bases.

To remove the seat, stand next to the seating unit and hold the seat with one hand at its back part. Then reach beneath the seat and turn the release switch (Fig. 4, Pos. b) downward.
The locking bolt will then unlock and release the adapter. At the same time, push the seating shell forward. You can then remove the seating shell unit.
To remount the seat onto the mobility base, place the back part of the seating shell interface onto the adapter carrier and slide the seating shell backwards until the locking bolt audibly clicks back into locking position. Make sure the seating shell is secure by giving the seat a few short tugs.
Checking Static Stability before Using the Mobility Base with Seating Shell After mounting a seating system, the stability of the entire product must be checked.
First prepare an area with an inclination of 10°. Place the mobility base with mounted seating system and the patient sitting in the seating system on this incline. The wheels should be in driving position (see illustration). Test the tilting behavior in the most unfavorable positions: to the front - extended footrest assembly (if possible), upright backrest (pos. a); to the rear - angled footrest assembly, tilted 30° to the rear, back angle 120° (pos. b).


Inclined and upright position (Fig. 4 and Fig. 12) You can tilt the seat by approx. 30° to the rear by pressing the release lever (Fig. 12, item 1). When the desired incli- nation is reached, release the finger pressure from the release lever.
Height adjustable pushbar (Fig. 5) Can be adjusted vertically to a more comfortable height for the attendant. Height adjustable push handles (Fig. 6) Can be adjusted vertically to a more comfortable height for the attendant. Angle adjustable back frame (Fig. 7) The angle between back frame and seat frame can be adjusted with the threaded rod (Fig. 7, item 1). The inclination range is 80° to 120°. This position is firmly set then. It has to be adjusted in accordance with the seating system you use.
Drum brake for attendant (Fig. 5 and 8) Allows braking of the wheelchair independent of tire pressure. • Tighten the clamping levers (Fig. 8, item 1) to bring the drum brakes in functional state. Release the lock by loosen- ing the ratchet pieces (fig. 8, item. 2).
a) b)

The mobility base for seating shells is designed as a modular assembly system, which means that certain accessories may be adapted to your it. The following options and accessories may make it easier to use your mobility base with seating shell.
Tip-assist (Fig. 16) For clearing obstacles like curbs etc. it may be necessary to tip the mobility base at the front. The tip-assist is used to make tipping easier. Step onto the tip-assist with your foot and pull the push handles / pushbar to the rear. Anti-tipper, swing-away (Fig. 17) Prevents the mobility base with seating shell from tipping too far backward. With slight downward pressure on the anti-tipper (item 1) it can be disengaged and swung to the inside (item 2) (for mounting instructions, refer to page 24). It is absolutely necessary that the anti-tipper be in functional position when tilting the seating unit to the rear or when adjusting the angle between seat and back to more than 90°!

Angle adjustment of the footplate (Fig. 26) The footplate of the Dino® 3 mobility base is angle adjustable. To adjust, slide a 5 mm Allen wrench through the side holes in the footrest bar until the wrench locks into the Allen screw in the footplate. Loosen the screw with several turns. A blow on the end of the Allen wrench will disengage the clamp connection. Adjust the footplate to the desired position and firmly re-tighten the screw. Single-panel footrest for short lower leg length (Fig. 27, 28) The footplate height can be adjusted using the lateral holes in the footrest bars (Fig. 28, item 1). To do this loosen the screws using an Allen head wrench and an open-jawed wrench. Position the footplate at the desired height and re-tighten the screw connection. You can also use this screw connection to pivot the footplate around the screw connection point (Fig. 28, item 2) to create a favorable position in relation to the seating shell you use. It will probably be necessary to readjust the foot- plate angle afterwards. The footplate can be flipped up towards one footrest bar making transfers of the patient easier in case the legs are ca- pable to bear weight. For angle adjustment please read section “Single-panel footrest, angle adjustable” on page 22. Individual footrests, angle adjustable (Fig. 29) With the individual footrests, angle adjustable, the right and left footplate can be flipped up to make transfers of the patient easier. For angle and height adjustments please read section “Single-panel footrest, angle adjustable” on page 22.

Individual footrests, elevating, angle adjustable (Fig. 30) The footrests can be adjusted within the range from 15° to 90°. Pull the footrests upward until they have reached the desired position. The footrests automatically lock in place. To reposition the footrests relieve the load on the footrests and press the release lever (item 1) downward to lower the footrests. Bring the footrests to the desired position. Make sure to always secure the footrests with your hand against uncontrolled falling downward when lowering it. Swinging away the individual footrests, elevating, angle adjustable (Fig. 30) Slightly lift the footrests and swing them to the inside or outside. For height and angle adjustments please read section “Single-panel footrest, angle adjustable” on page 22. Footrest assembly for seating shell interface (Fig. 31) Is mounted to the seating shell interface. The knee angle can be adjusted using the clamping lever (Fig. 31, item 1). The Allen head screws (Fig. 31, item 2) allow adaptation to the lower leg length. The single-panel footrest is angle adjustable. • Make sure that the footplate does not contact the caster. Preparation for Scala-Mobil The standard model of the Dino® 3 mobility base can be equipped with a preparation for the Scala-Mobil climbing assist for stairs. Your rehabilitation technology supplier will instruct you in adapting and using this climbing assist.

We recommend that, wherever and whenever possible, users transfer to the seats installed in the motor vehicle and use the corresponding vehicle restraint systems, because this is the only way to ensure optimum protection of the passengers in case of an accident.
It is, however, possible to use your Otto Bock product Dino® 3 as a seat in a motor vehicle, provided that the Otto Bock safety elements and appropriate restraint systems are used. For more information, please refer to our instructions for use: “Using your wheelchair/ mobility base with seating shell or buggy as a seat in motor vehicles”, article number: 646D158.
Please read the 646D158 Instructions for Use before using your Otto Bock product as a seat in motor vehicles!

The manufacturer’s warranty applies only if the product has been used under the conditions and for the purposes described. The manufacturer recommends that the product be used and maintained according to the instructions for use. The manufacturer is not responsible for damages caused by components and spare parts not approved by the ma- nufacturer. Repairs must be carried out exclusively by authorized dealers or by the manufacturer.

Dimensions of the Dino® 3 (in cm) 1. Overall length Rear wheel 12.5" Rear wheel 22" Rear wheel 24" Max. wheelbase 77 93 95.5 Min. wheelbase 77 80 82.5 Length with 88.9 106 108.5 single-panel footrest
Seat tube depth (front edge of back tube to front edge of seat tube) 35.5 cm