Operating Instructions Air Conditioner 2-11
Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Nederlands Italiano Deutsch Español Français English
Model No. Indoor Unit INVERTER DELUXE XE series E series CS-XE7PKEW CS-XE9PKEW CS-XE12PKEW CS-XE15PKEW CS-XE18PKEW CS-XE21PKEW
Comment utiliser l’appareil Climatiseur 12-21
Nous vous remercions d’avoir porté votre choix sur un climatiseur Panasonic. Instructions d’installation jointes. Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Instrucciones de funcionamiento Climatizador de aire 22-31
Muchas gracias por elegir una unidad de aire acondicionado Panasonic. Incluye instrucciones de instalación. Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
Outdoor Unit Single Split Multi Split CU-E7PKE CU-E9PKE CU-E12PKE CU-E15PKE CU-E18PKE CU-E21PKE CU-E24PKE
Wir danken Ihnen für den Kauf Ihres Panasonic- Klimageräts. Die Montageanleitung liegt dem Gerät bei. Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
Istruzioni di funzionamento Condizionatore d’aria 42-51
Grazie per aver acquistato un climatizzatore Panasonic. Istruzioni d’installazione allegate. Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro.
Hartelijk dank voor de aanschaf van de Panasonicairconditioner. Installatie-instructies bijgevoegd. Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig en bewaar ze voor toekomstig gebruik.
Bedienungsanleitung Klimagerät 32-41 · Handleiding Airconditioner 52-61

ECONAVI and AUTO COMFORT Equipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, and keeps the room consistently comfortable with minimum energy consumption. Furthermore, the sunlight sensor detects the sunlight intensity and helps control heating/cooling temperatures to provide optimum comfort. See “To learn more...” for details.
nanoe-G Deactivates harmful micro-organisms such as viruses, bacteria, etc. to keep air clean. It also deactivates viruses and bacteria on the fi lter to keep inside of the unit clean.

Multi air conditioner system Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. • For complete product features, please refer catalogue.

Outdoor unit ( CU-2E15PBE, CU-2E18PBE, CU-3E18PBE,



To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
Indoor unit and outdoor unit
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
This sign warns of death or serious injury.
This sign warns of injury or damage to property.
Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
Confi rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
These symbols denote actions COMPULSORY.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
Air inlet Air inlet
Air outlet Air outlet
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
Air inlet Air inlet
Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
Air outlet Air outlet

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.
Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.
If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard.
Do not expose plants or pet directly to airfl ow to avoid injury, etc.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.
Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to avoid injury.
Do not step onto an unstable bench when cleaning the unit to avoid injury.
Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not open window or door for long time during COOL/DRY mode operation.
Prevent water leakage by ensuring drainage pipe is: - Connected properly, - Kept clear of gutters and containers, or - Not immersed in water
After a long period of use or use with any combustible equipment, aerate the room regularly.
This equipment must be earthed to prevent electrical shock or fi re.
After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.
Prevent electric shock by switching off the power supply and unplug: - Before cleaning or servicing, - When extended non-use, or - During abnormally strong lightning activity.
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.
Do not disconnect the plug by pulling the cord to prevent electric shock.
Safety precautions

Single Single split system
Multi Multi split system

(Green) (Green) (Blue) (Orange) (Orange) (Orange) (Green)



















To select operation mode
AUTO - For your convenience HEAT - To enjoy warm air COOL - To enjoy cool air DRY - To dehumidify the environment
Sunlight sensor and remote control receiver
COOLING To improve humidity and
AUTO
FAN SPEED
moisture level
HEAT COOL
AIR SWING
MILD
DRY
OFF/ON
OFF/ON
AUTO COMFORT
MODE
NANOE-G
Press and hold for approximately 10 seconds to show temperature setting in °C or °F.
COOLING
TEMP
TEMP
Multi • Function not applicable.
QUIET
AIR SWING FAN SPEED
POWERFUL/
QUIET To switch between powerful & quiet
Press to restore the remote control to default setting.
POWERFUL: To reach temperature quickly
AC RC
SET CHECK CLOCK RESET
CHECK CLOCK
POWERFUL
Not used in normal operations.
Single • This operation stops automatically after 20 minutes.
Multi • Press the button again or turn OFF the unit to stop this operation. QUIET: To enjoy quiet operation
To select fan speed
( Remote control display )
QUIET • This operation reduces airfl ow noise.

Use when remote control is misplaced or a malfunction occurs. Raise the front panel: 1. Press the button once to use in AUTO mode. 2. Press and hold the button until you hear 1 beep, then release to use in forced COOL mode. 3. Repeat step 2. Press and hold the button until you hear 2 beeps, then release to use in forced HEAT mode. • Press the button again to turn off.

See "To learn more..." for details.



NANOE-G • nanoe-G starts automatically when the unit is turned on with
Multi • This operation cannot be performed or will be stopped if other indoor unit is activating HEAT mode.
until a short beep sound is heard. This will not disable the nanoe-G to purify the air. • To restore the nanoe-G in-fi lter deactivation, press and

CANCEL. • If timer is cancelled manually or due to power failure, you can restore the timer again by pressing
ON or OFF to select respective or then press


To learn more...
Single Single split system
Multi Multi split system
AUTO : During operation mode selection the POWER indicator blinks.
Single • Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
Multi • Unit selects operation mode every 3 hours according to setting temperature, outdoor temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY : Unit operates at low fan speed to give a gentle cooling operation.
Depending on the unit’s accumulated operation time, nanoe-G in-fi lter deactivation may activate only once a day after the unit turned off.
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This process only applicable when the unit is operated in COOL/DRY mode before turned off. Then, nanoe-G deactivates viruses/bacteria on the fi lter for 2 hours with fan stopped and louver closed.
Do not turn off the power supply during this operation. After power failure, this operation will not resume.
AIR SWING When manual AIR SWING is selected, the ECONAVI and AUTO COMFORT operations will be cancelled. The unit will start to initialise (for approximately 1 minute)
The human activity sensor and the sunlight sensor will start to detect.
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Low activity Normal activity Human Mode
+2 °C +1 °C
HEAT
-2 °C -2 °C
AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human
comfortable consistently.
HEAT
ECONAVI and AUTO COMFORT
Precise control of temperature during low activity to maximise energy saving.
Low activity Human Mode
ECONAVI and AUTO COMFORT take advantage of the human nature that human being takes time to feel the temperature rise during low activity level; the unit adjusts temperature to maximise energy saving without sacrificing the comfort.
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached. ** During human absence, maximum fan speed for COOL/DRY mode is medium fan.

The human activity sensor will also scan for area of heat source and movement in a room.
To learn more...
ECONAVI is activated, the unit maintains set temperature until a high sunlight intensity is detected. The sunlight sensor detects sunlight intensity during weather or day/night changes, and the unit adjusts temperature.
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
COOL/DRY
-1 °C -1 °C


To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorised dealer.
Aluminium fi n Front panel
Indoor unit Wipe the unit gently with a soft, dry cloth.
Human activity sensor Do not hit or violently press or poke it with a sharp object. This can lead to damage and malfunction.
Front panel Wash gently and dry.
Remove air fi lter Attach air fi lter
Close it securely
Insert at both sides 1
Insert into the unit
Press both ends of the front panel 3
For CS-XE18PKEW, CS-XE21PKEW, CS-E18PKEW, CS-E21PKEW, CS-E24PKEW: Press at center of the front panel.

The following symptoms do not indicate malfunction.
Cleaning instructions / Troubleshooting
Check the following before calling for servicing.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Mist emerges from indoor unit. | • Condensation effect due to cooling process. | p.11 | |
| Water fl owing sound during operation. | • Refrigerant fl ow inside the unit. | p.11 | |
| The room has a peculiar odour. | • This may be due to damp smell emitted by the wall, carpet, furniture or clothing. | p.11 | |
| Indoor fan stops occasionally during automatic fan speed setting. | • This helps to remove the surrounding odour. | p.11 | |
| Airfl ow continues even after operation has stopped. | • Extraction of remaining heat from the indoor unit (maximum 30 seconds). | p.11 | |
| Operation is delayed a few minutes after restarting. | • The delay is a protection to the unit’s compressor. | p.11 | |
| Outdoor unit emits water/steam. | • Condensation or evaporation occurs on pipes. | p.11 | |
| TIMER indicator is always on. | • The timer setting repeats daily once set. | p.11 | |
| POWER indicator blinks during HEAT mode with no warm air supply (and louver is closed). | • The unit is in defrost mode (and AIR SWING is set to AUTO). | p.11 | |
| Indoor fan stops occasionally during heating operation. | • To avoid unintended cooling effect. | p.11 | |
| POWER indicator blinks before the unit is switched on. | • This is a preliminary step in preparation for the operation when the ON timer has been set. | p.11 | |
| Cracking sound during operation. | • Changes of temperature caused the expansion/ contraction of the unit. | p.11 | |
| Operation in HEAT/COOL mode is not working effi ciently. | • Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. | p.11 | |
| Noisy during operation. | • Check if the unit has been installed at an incline. • Close the front panel properly. | p.11 | |
| Remote control does not work. (Display is dim or transmission signal is weak.) | • Insert the batte • Replace weak | p.11 | |
| The unit does not work. | • Check if the cir • Check if timers | p.11 | |
| The unit does not receive the signal from the remote control. | • Make sure the • Certain fl uores transmitter. Ple | p.11 | |
| NON SERVICEABLE CRITERIAS The unit stops and the TIMER indicator blinks. TURN OFF POWER SUPPLY AND Use remote control to retrieve error code. UNPLUG then please consult authorised 1 Press for TIMER 2 Press until you dealer under the following conditions: 5 seconds ON SET hear beep sound, • Abnormal noise during operation. 1 2 3 then write down • Water/foreign particles have entered the 3 Press for OFF CANCEL the error code remote control. 5 seconds AC RC 4 Turn the unit off • Water leaks from Indoor unit. to quit SET CHECK CLOCK RESET and reveal the • Circuit breaker switches off frequently. checking error code to • Power cord becomes unnaturally warm. authorised dealer | p.11 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.